Kyoyeong Koo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kyoyeong Koo has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Heeryeol Jeong
School of Computer Science and Engineering , Soongsil University , Seoul, Korea
2 shared publications - Jeongjin Lee
School of Computer Science and Engineering, Soongsil University, Seoul, Republic of Korea
2 shared publications - Juneseuk Shin
Department of Systems Management Engineering, Sungkyunkwan University, 2066, Seobu-ro, Jangan-gu, Suwon-si, Gyeong gi-do 440-746, Republic of Korea
2 shared publications - Seungwoo Khang
School of Computer Science and Engineering, Soongsil University, Seoul, Republic of Korea
2 shared publications - Taeyong Park
Medical Artificial Intelligence Center, Doheon Institute for Digital Innovation in Medicine, Hallym Univesity Medical Center, Anyang-si 14068, Republic of Korea
2 shared publications - Hochul Kang
Department of Digital Media Engineering, The Catholic University of Korea, Bucheon-si 14662, Republic of Korea
1 shared publication
Latest Publications
- 12 December 2022
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 13 (1) , 65-72
Non-rigid registration based on hierarchical deformation of coronary arteries in CCTA images
In this paper, we propose an accurate and rapid non-rigid registration method between blood vessels in temporal 3D cardiac computed tomography angiography images of the same patient. This method provides auxiliary information that can be utilized in the diagnosis and treatment of coronary artery diseases. The proposed method consists of the following four steps. First, global registration is conducted through rigid registration between the 3D vessel centerlines obtained from temporal 3D cardiac CT angiography images. Second, point matching between the 3D vessel centerlines in the rigid registration results is performed, and the corresponding points are defined. Third, the outliers in the matched corresponding points are removed by using various information such as thickness and gradient of the vessels. Finally, non-rigid registration is conducted for hierarchical local transformation using an energy function. The experiment results show that the average registration error of the proposed method is 0.987 mm, and the average execution time is 2.137 s, indicating that the registration is accurate and rapid. The proposed method that enables rapid and accurate registration by using the information on blood vessel characteristics in temporal CTA images of the same patient.
- 12 December 2022
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 13 (1) , 65-72
Non-rigid registration based on hierarchical deformation of coronary arteries in CCTA images
In this paper, we propose an accurate and rapid non-rigid registration method between blood vessels in temporal 3D cardiac computed tomography angiography images of the same patient. This method provides auxiliary information that can be utilized in the diagnosis and treatment of coronary artery diseases. The proposed method consists of the following four steps. First, global registration is conducted through rigid registration between the 3D vessel centerlines obtained from temporal 3D cardiac CT angiography images. Second, point matching between the 3D vessel centerlines in the rigid registration results is performed, and the corresponding points are defined. Third, the outliers in the matched corresponding points are removed by using various information such as thickness and gradient of the vessels. Finally, non-rigid registration is conducted for hierarchical local transformation using an energy function. The experiment results show that the average registration error of the proposed method is 0.987 mm, and the average execution time is 2.137 s, indicating that the registration is accurate and rapid. The proposed method that enables rapid and accurate registration by using the information on blood vessel characteristics in temporal CTA images of the same patient.
- Open Access
- 22 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (4) , 778
Deep Learning Segmentation in 2D X-ray Images and Non-Rigid Registration in Multi-Modality Images of Coronary Arteries
X-ray angiography is commonly used in the diagnosis and treatment of coronary artery disease with the advantage of visualization of the inside of blood vessels in real-time. However, it has several disadvantages that occur in the acquisition process, which causes inconvenience and difficulty. Here, we propose a novel segmentation and nonrigid registration method to provide useful real-time assistive images and information. A convolutional neural network is used for the segmentation of coronary arteries in 2D X-ray angiography acquired from various angles in real-time. To compensate for errors that occur during the 2D X-ray angiography acquisition process, 3D CT angiography is used to analyze the topological structure. A novel energy function-based 3D deformation and optimization is utilized to implement real-time registration. We evaluated the proposed method for 50 series from 38 patients by comparing the ground truth. The proposed segmentation method showed that Precision, Recall, and F1 score were 0.7563, 0.6922, and 0.7176 for all vessels, 0.8542, 0.6003, and 0.7035 for markers, and 0.8897, 0.6389, and 0.7386 for bifurcation points, respectively. In the nonrigid registration method, the average distance of 0.8705, 1.06, and 1. 5706 mm for all vessels, markers, and bifurcation points was achieved. The overall process execution time was 0.179 s.
- 22 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (4) , 778
Open AccessDeep Learning Segmentation in 2D X-ray Images and Non-Rigid Registration in Multi-Modality Images of Coronary Arteries
X-ray angiography is commonly used in the diagnosis and treatment of coronary artery disease with the advantage of visualization of the inside of blood vessels in real-time. However, it has several disadvantages that occur in the acquisition process, which causes inconvenience and difficulty. Here, we propose a novel segmentation and nonrigid registration method to provide useful real-time assistive images and information. A convolutional neural network is used for the segmentation of coronary arteries in 2D X-ray angiography acquired from various angles in real-time. To compensate for errors that occur during the 2D X-ray angiography acquisition process, 3D CT angiography is used to analyze the topological structure. A novel energy function-based 3D deformation and optimization is utilized to implement real-time registration. We evaluated the proposed method for 50 series from 38 patients by comparing the ground truth. The proposed segmentation method showed that Precision, Recall, and F1 score were 0.7563, 0.6922, and 0.7176 for all vessels, 0.8542, 0.6003, and 0.7035 for markers, and 0.8897, 0.6389, and 0.7386 for bifurcation points, respectively. In the nonrigid registration method, the average distance of 0.8705, 1.06, and 1. 5706 mm for all vessels, markers, and bifurcation points was achieved. The overall process execution time was 0.179 s.