Francisco Montero de Espinosa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Francisco Montero de Espinosa has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Luis Elvira
Centro de Acústica Aplicada y Evaluación no destructiva, UPM-CSIC Serrano 144, Madrid 28006, Spain
5 shared publications - Silvia Ronda Penacoba
ITEFI-CSIC, Institute of Physics and Communication Technologies, 28006 Madrid, Spain
4 shared publications - Gerardo Portilla
ITEFI-CSIC Spanish High Research Council, Serrano 144, 28006 Madrid, Spain
2 shared publications J Rodríguez-López
Spanish Natl Res Council, Ctr Appl Phys & Non Destruct Evaluat CAEND CSIC, Madrid 28006, Spain
2 shared publications- José Luis Aragón
Affiliation Universidad Nacional Autónoma de México, Centro de Física Aplicada y Tecnología Avanzada, Querétaro, Mexico
2 shared publications - Juan de Vicente
F2N2Lab, Magnetic Soft Matter Group, Department of Applied Physics, Faculty of Sciences, University of Granada, C/Fuentenueva s/n, Granada 18071, Spain
2 shared publications
Latest Publications
- Open Access
- 14 June 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (9) , 1415-1425
Ultrasound Therapy With High-Pressure Pulses Is Effective to Reduce the Effects of Collagenase-Induced Tendinopathy in Rat's Achilles Tendon
- 14 June 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (9) , 1415-1425
Open AccessUltrasound Therapy With High-Pressure Pulses Is Effective to Reduce the Effects of Collagenase-Induced Tendinopathy in Rat's Achilles Tendon
- Open Access
Device for Dual Ultrasound and Dry Needling Trigger Points Treatment
Ultrasound is a well-known tool to produce thermal and non-thermal effects on cells and tissues. These effects require an appropriate application of ultrasound in terms of localization and acoustic energy delivered. This article describes a new device that combines ultrasound and dry needling treatments. The non-thermal effects of ultrasound should locally amplify the needle’s effects. The ultrasound transducer can mechanically rotate in 3D space to align itself in the direction of the needle. The transducer electronically focuses the acoustic pressure automatically on the needle tip and its surroundings. A computer, using graphical interface software, controls the angulation of the array and the focus position.
Open AccessDevice for Dual Ultrasound and Dry Needling Trigger Points Treatment
Ultrasound is a well-known tool to produce thermal and non-thermal effects on cells and tissues. These effects require an appropriate application of ultrasound in terms of localization and acoustic energy delivered. This article describes a new device that combines ultrasound and dry needling treatments. The non-thermal effects of ultrasound should locally amplify the needle’s effects. The ultrasound transducer can mechanically rotate in 3D space to align itself in the direction of the needle. The transducer electronically focuses the acoustic pressure automatically on the needle tip and its surroundings. A computer, using graphical interface software, controls the angulation of the array and the focus position.
- Open Access
- 23 November 2022
- Published by MDPI AG in Preprints.org
Device for Dual Ultrasound & Dry Needling Trigger Points Treatment
Ultrasound is a well-known tool to produce thermal and non-thermal effects on cells and tissues. These effects require a correct application of ultrasound in terms of localization and acoustic energy delivered. This article describes a new device that combines ultrasound and Dry Needling treatments. The ultrasound transducer can rotate in 3D space mechanically to align itself in the direction of the needle. The transducer electronically focuses the acoustic pressure automatically on the needle tip and its surroundings. A computer, using graphical interface software, controls the angulation of the array and the focus position.
- 23 November 2022
- Published by MDPI AG in Preprints.org
Open AccessDevice for Dual Ultrasound & Dry Needling Trigger Points Treatment
Ultrasound is a well-known tool to produce thermal and non-thermal effects on cells and tissues. These effects require a correct application of ultrasound in terms of localization and acoustic energy delivered. This article describes a new device that combines ultrasound and Dry Needling treatments. The ultrasound transducer can rotate in 3D space mechanically to align itself in the direction of the needle. The transducer electronically focuses the acoustic pressure automatically on the needle tip and its surroundings. A computer, using graphical interface software, controls the angulation of the array and the focus position.
- Open Access
- 1 March 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (3) , 035043
Optoacoustic imaging with an air-coupled transducer using coaxially aligned focused illumination
Optoacoustic (OA) methods have become powerful tools in biomedical research capable of retrieving functional information from biological tissues in vivo. Acquisition of OA signals generally relies on direct physical contact of a transducer or an acoustic coupling medium with the tissue surface, which prevents applicability, e.g., in open surgeries or wounded tissues. Non-contact OA imaging has been achieved with air-coupled piezoelectric transducers, which provide a straightforward approach for remote sensing of ultrasound vibrations. However, sensitivity was hampered by a suboptimal alignment between the illumination and detection fields. Herein, we devised an air-coupled transducer featuring a central aperture for light delivery with coaxially aligned optical and acoustic foci, thus providing optimal sensitivity for OA signal detection. Imaging of phantoms and a mouse ear in vivo is showcased by raster-scanning the transducer with light being delivered through a multimode optical fiber.
- 1 March 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (3) , 035043
Open AccessOptoacoustic imaging with an air-coupled transducer using coaxially aligned focused illumination
Optoacoustic (OA) methods have become powerful tools in biomedical research capable of retrieving functional information from biological tissues in vivo. Acquisition of OA signals generally relies on direct physical contact of a transducer or an acoustic coupling medium with the tissue surface, which prevents applicability, e.g., in open surgeries or wounded tissues. Non-contact OA imaging has been achieved with air-coupled piezoelectric transducers, which provide a straightforward approach for remote sensing of ultrasound vibrations. However, sensitivity was hampered by a suboptimal alignment between the illumination and detection fields. Herein, we devised an air-coupled transducer featuring a central aperture for light delivery with coaxially aligned optical and acoustic foci, thus providing optimal sensitivity for OA signal detection. Imaging of phantoms and a mouse ear in vivo is showcased by raster-scanning the transducer with light being delivered through a multimode optical fiber.
- Open Access
- 25 January 2022
- Published by Elsevier in Ultrasonics
- Vol. 121, 106693
System and method for applying physiotherapeutic focused ultrasound
- 25 January 2022
- Published by Elsevier in Ultrasonics
- Vol. 121, 106693
Open AccessSystem and method for applying physiotherapeutic focused ultrasound
- Open Access
Effects of Non-thermal Ultrasound on a Fibroblast Monolayer Culture: Influence of Pulse Number and Pulse Repetition Frequency
Despite the use of therapeutic ultrasound in the treatment of soft tissue pathologies, there remains some controversy regarding its efficacy. In order to develop new treatment protocols, it is a common practice to carry out in vitro studies in cell cultures before conducting animal tests. The lack of reproducibility of the experimental results observed in the literature concerning in vitro experiments motivated us to establish a methodology for characterizing the acoustic field in culture plate wells. In this work, such acoustic fields are fully characterized in a real experimental configuration, with the transducer being placed in contact with the surface of a standard 12-well culture plate. To study the non-thermal effects of ultrasound on fibroblasts, two different treatment protocols are proposed: long pulse (200 cycles) signals, which give rise to a standing wave in the well with the presence of cavitation (ISPTP max = 19.25 W/cm2), and a short pulse (five cycles) of high acoustic pressure, which produces a number of echoes in the cavity (ISPTP = 33.1 W/cm2, with Pmax = 1.01 MPa). The influence of the acoustic intensity, the number of pulses, and the pulse repetition frequency was studied. We further analyzed the correlation of these acoustic parameters with cell viability, population, occupied surface, and cell morphology. Lytic effects when cavitation was present, as well as mechanotransduction reactions, were observed.
Open AccessEffects of Non-thermal Ultrasound on a Fibroblast Monolayer Culture: Influence of Pulse Number and Pulse Repetition Frequency
Despite the use of therapeutic ultrasound in the treatment of soft tissue pathologies, there remains some controversy regarding its efficacy. In order to develop new treatment protocols, it is a common practice to carry out in vitro studies in cell cultures before conducting animal tests. The lack of reproducibility of the experimental results observed in the literature concerning in vitro experiments motivated us to establish a methodology for characterizing the acoustic field in culture plate wells. In this work, such acoustic fields are fully characterized in a real experimental configuration, with the transducer being placed in contact with the surface of a standard 12-well culture plate. To study the non-thermal effects of ultrasound on fibroblasts, two different treatment protocols are proposed: long pulse (200 cycles) signals, which give rise to a standing wave in the well with the presence of cavitation (ISPTP max = 19.25 W/cm2), and a short pulse (five cycles) of high acoustic pressure, which produces a number of echoes in the cavity (ISPTP = 33.1 W/cm2, with Pmax = 1.01 MPa). The influence of the acoustic intensity, the number of pulses, and the pulse repetition frequency was studied. We further analyzed the correlation of these acoustic parameters with cell viability, population, occupied surface, and cell morphology. Lytic effects when cavitation was present, as well as mechanotransduction reactions, were observed.
- 2 November 2017
- Published by SAGE Publications in Advances in Applied Ceramics: Structural, Functional and Bioceramics
- Vol. 117 (3) , 177-181
Design of piezoelectric piston-like piezoelectric transducers based on a phononic crystal
Many clinical surveys have evaluated the use of ultrasound in physiotherapy treatments, the question of its effectiveness still being under discussion possibly because of the randomized energy density applied, which depends on the acoustic pressure beam of the transducers. In this work, a phononic crystal made of holes in solid materials is the basis for the design of a transducer with a piston-like vibration pattern where the radial modes are stopped, thus favoring the thickness vibration and resulting in a better mechanical vibration amplitude and acoustic efficiency. Finite element simulations have been made of the standard transducer and the proposed design; then demonstrator devices have been manufactured and tested so experimental results could be compared to the calculated ones. The transducers with this phononic structure show an efficient piston-like emission. The electrical impedance, the emitting surface vibration pattern and the acoustic diffraction field have been calculated and experimentally measured.
- 2 November 2017
- Published by SAGE Publications in Advances in Applied Ceramics: Structural, Functional and Bioceramics
- Vol. 117 (3) , 177-181
Design of piezoelectric piston-like piezoelectric transducers based on a phononic crystal
Many clinical surveys have evaluated the use of ultrasound in physiotherapy treatments, the question of its effectiveness still being under discussion possibly because of the randomized energy density applied, which depends on the acoustic pressure beam of the transducers. In this work, a phononic crystal made of holes in solid materials is the basis for the design of a transducer with a piston-like vibration pattern where the radial modes are stopped, thus favoring the thickness vibration and resulting in a better mechanical vibration amplitude and acoustic efficiency. Finite element simulations have been made of the standard transducer and the proposed design; then demonstrator devices have been manufactured and tested so experimental results could be compared to the calculated ones. The transducers with this phononic structure show an efficient piston-like emission. The electrical impedance, the emitting surface vibration pattern and the acoustic diffraction field have been calculated and experimentally measured.
- Open Access
Study of the Relation between the Resonance Behavior of Thickness Shear Mode (TSM) Sensors and the Mechanical Characteristics of Biofilms
This work analyzes some key aspects of the behavior of sensors based on piezoelectric Thickness Shear Mode (TSM) resonators to study and monitor microbial biofilms. The operation of these sensors is based on the analysis of their resonance properties (both resonance frequency and dissipation factor) that vary in contact with the analyzed sample. This work shows that different variations during the microorganism growth can be detected by the sensors and highlights which of these changes are indicative of biofilm formation. TSM sensors have been used to monitor in real time the development of Staphylococcus epidermidis and Escherichia coli biofilms, formed on the gold electrode of the quartz crystal resonators, without any coating. Strains with different ability to produce biofilm have been tested. It was shown that, once a first homogeneous adhesion of bacteria was produced on the substrate, the biofilm can be considered as a semi-infinite layer and the quartz sensor reflects only the viscoelastic properties of the region immediately adjacent to the resonator, not being sensitive to upper layers of the biofilm. The experiments allow the microrheological evaluation of the complex shear modulus (G* = G′ + jG″) of the biofilm at 5 MHz and at 15 MHz, showing that the characteristic parameter that indicates the adhesion of a biofilm for the case of S. epidermidis and E. coli, is an increase in the resonance frequency shift of the quartz crystal sensor, which is connected with an increase of the real shear modulus, related to the elasticity or stiffness of the layer. In addition both the real and the imaginary shear modulus are frequency dependent at these high frequencies in biofilms.
Open AccessStudy of the Relation between the Resonance Behavior of Thickness Shear Mode (TSM) Sensors and the Mechanical Characteristics of Biofilms
This work analyzes some key aspects of the behavior of sensors based on piezoelectric Thickness Shear Mode (TSM) resonators to study and monitor microbial biofilms. The operation of these sensors is based on the analysis of their resonance properties (both resonance frequency and dissipation factor) that vary in contact with the analyzed sample. This work shows that different variations during the microorganism growth can be detected by the sensors and highlights which of these changes are indicative of biofilm formation. TSM sensors have been used to monitor in real time the development of Staphylococcus epidermidis and Escherichia coli biofilms, formed on the gold electrode of the quartz crystal resonators, without any coating. Strains with different ability to produce biofilm have been tested. It was shown that, once a first homogeneous adhesion of bacteria was produced on the substrate, the biofilm can be considered as a semi-infinite layer and the quartz sensor reflects only the viscoelastic properties of the region immediately adjacent to the resonator, not being sensitive to upper layers of the biofilm. The experiments allow the microrheological evaluation of the complex shear modulus (G* = G′ + jG″) of the biofilm at 5 MHz and at 15 MHz, showing that the characteristic parameter that indicates the adhesion of a biofilm for the case of S. epidermidis and E. coli, is an increase in the resonance frequency shift of the quartz crystal sensor, which is connected with an increase of the real shear modulus, related to the elasticity or stiffness of the layer. In addition both the real and the imaginary shear modulus are frequency dependent at these high frequencies in biofilms.
- Open Access
The Use of Phononic Crystals to Design Piezoelectric Power Transducers
It was recently proposed that the lateral resonances around the working resonance band of ultrasonic piezoelectric sandwich transducers can be stopped by a periodic array of circular holes drilled along the main propagation direction (a phononic crystal). In this work, the performance of different transducer designs made with this procedure is tested using laser vibrometry, electric impedance tests and finite element models (FEM). It is shown that in terms of mechanical vibration amplitude and acoustic efficiency, the best design for physiotherapy applications is when both, the piezoceramic and an aluminum capsule are phononic structures. The procedure described here can be applied to the design of power ultrasonic devices, physiotherapy transducers and other external medical power ultrasound applications where piston-like vibration in a narrow band is required.
Open AccessThe Use of Phononic Crystals to Design Piezoelectric Power Transducers
It was recently proposed that the lateral resonances around the working resonance band of ultrasonic piezoelectric sandwich transducers can be stopped by a periodic array of circular holes drilled along the main propagation direction (a phononic crystal). In this work, the performance of different transducer designs made with this procedure is tested using laser vibrometry, electric impedance tests and finite element models (FEM). It is shown that in terms of mechanical vibration amplitude and acoustic efficiency, the best design for physiotherapy applications is when both, the piezoceramic and an aluminum capsule are phononic structures. The procedure described here can be applied to the design of power ultrasonic devices, physiotherapy transducers and other external medical power ultrasound applications where piston-like vibration in a narrow band is required.
- 1 September 2016
- Published by Elsevier in Ultrasonics
- Vol. 71, 177-182
Planar modes free piezoelectric resonators using a phononic crystal with holes
- 1 September 2016
- Published by Elsevier in Ultrasonics
- Vol. 71, 177-182
Planar modes free piezoelectric resonators using a phononic crystal with holes