Louis Cheng
Research Subjects
Louis Cheng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Gregorij Kurillo
University of California at Berkeley
2 shared publications - Evan Hemingway
Applied BioMechanics, Alameda, CA 94501, USA
1 shared publication - Jay J. Han
Department of Physical Medicine and Rehabilitation, University of California at Irvine School of Medicine, Irvine, CA 92868, USA
1 shared publication - Jeffrey C. Lotz
Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, USA
1 shared publication - Mu-Lin Cheng
Bioniks, Alameda, CA 94501, USA
1 shared publication - Robert Peter Matthew
Department of Physical Therapy and Rehabilitation Science, University of California, San Francisco, San Francisco, CA, United States
1 shared publication
Latest Publications
- Open Access
Evaluating the Accuracy of the Azure Kinect and Kinect v2
The Azure Kinect represents the latest generation of Microsoft Kinect depth cameras. Of interest in this article is the depth and spatial accuracy of the Azure Kinect and how it compares to its predecessor, the Kinect v2. In one experiment, the two sensors are used to capture a planar whiteboard at 15 locations in a grid pattern with laser scanner data serving as ground truth. A set of histograms reveals the temporal-based random depth error inherent in each Kinect. Additionally, a two-dimensional cone of accuracy illustrates the systematic spatial error. At distances greater than 2.5 m, we find the Azure Kinect to have improved accuracy in both spatial and temporal domains as compared to the Kinect v2, while for distances less than 2.5 m, the spatial and temporal accuracies were found to be comparable. In another experiment, we compare the distribution of random depth error between each Kinect sensor by capturing a flat wall across the field of view in horizontal and vertical directions. We find the Azure Kinect to have improved temporal accuracy over the Kinect v2 in the range of 2.5 to 3.5 m for measurements close to the optical axis. The results indicate that the Azure Kinect is a suitable substitute for Kinect v2 in 3D scanning applications.
Open AccessEvaluating the Accuracy of the Azure Kinect and Kinect v2
The Azure Kinect represents the latest generation of Microsoft Kinect depth cameras. Of interest in this article is the depth and spatial accuracy of the Azure Kinect and how it compares to its predecessor, the Kinect v2. In one experiment, the two sensors are used to capture a planar whiteboard at 15 locations in a grid pattern with laser scanner data serving as ground truth. A set of histograms reveals the temporal-based random depth error inherent in each Kinect. Additionally, a two-dimensional cone of accuracy illustrates the systematic spatial error. At distances greater than 2.5 m, we find the Azure Kinect to have improved accuracy in both spatial and temporal domains as compared to the Kinect v2, while for distances less than 2.5 m, the spatial and temporal accuracies were found to be comparable. In another experiment, we compare the distribution of random depth error between each Kinect sensor by capturing a flat wall across the field of view in horizontal and vertical directions. We find the Azure Kinect to have improved temporal accuracy over the Kinect v2 in the range of 2.5 to 3.5 m for measurements close to the optical axis. The results indicate that the Azure Kinect is a suitable substitute for Kinect v2 in 3D scanning applications.
- Open Access
- 23 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (11) , 3285-3294
Reachable Workspace and Proximal Function Measures for Quantifying Upper Limb Motion
There are a lack of quantitative measures for clinically assessing upper limb function. Conventional biomechanical performance measures are restricted to specialist labs due to hardware cost and complexity, while the resulting measurements require specialists for analysis. Depth cameras are low cost and portable systems that can track surrogate joint positions. However, these motions may not be biologically consistent, which can result in noisy, inaccurate movements. This paper introduces a rigid body modelling method to enforce biological feasibility of the recovered motions. This method is evaluated on an existing depth camera assessment: the reachable workspace (RW) measure for assessing gross shoulder function. As a rigid body model is used, position estimates of new proximal targets can be added, resulting in a proximal function (PF) measure for assessing a subject's ability to touch specific body landmarks. The accuracy, and repeatability of these measures is assessed on ten asymptomatic subjects, with and without rigid body constraints. This analysis is performed both on a low-cost depth camera system and a gold-standard active motion capture system. The addition of rigid body constraints was found to improve accuracy and concordance of the depth camera system, particularly in lateral reaching movements. Both RW and PF measures were found to be feasible candidates for clinical assessment, with future analysis needed to determine their ability to detect changes within specific patient populations.
- 23 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (11) , 3285-3294
Open AccessReachable Workspace and Proximal Function Measures for Quantifying Upper Limb Motion
There are a lack of quantitative measures for clinically assessing upper limb function. Conventional biomechanical performance measures are restricted to specialist labs due to hardware cost and complexity, while the resulting measurements require specialists for analysis. Depth cameras are low cost and portable systems that can track surrogate joint positions. However, these motions may not be biologically consistent, which can result in noisy, inaccurate movements. This paper introduces a rigid body modelling method to enforce biological feasibility of the recovered motions. This method is evaluated on an existing depth camera assessment: the reachable workspace (RW) measure for assessing gross shoulder function. As a rigid body model is used, position estimates of new proximal targets can be added, resulting in a proximal function (PF) measure for assessing a subject's ability to touch specific body landmarks. The accuracy, and repeatability of these measures is assessed on ten asymptomatic subjects, with and without rigid body constraints. This analysis is performed both on a low-cost depth camera system and a gold-standard active motion capture system. The addition of rigid body constraints was found to improve accuracy and concordance of the depth camera system, particularly in lateral reaching movements. Both RW and PF measures were found to be feasible candidates for clinical assessment, with future analysis needed to determine their ability to detect changes within specific patient populations.