Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Saleh T. Alanezi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Differential Diagnosis of Prostate Cancer Grade to Augment Clinical Diagnosis Based on Classifier Models with Tuned Hyperparameters

    by Saleh T. Alanezi, Marcin Jan Kraśny, Christoph Kleefeld, Niall Colgan

    We developed a novel machine-learning algorithm to augment the clinical diagnosis of prostate cancer utilizing first and second-order texture analysis metrics in a novel application of machine-learning radiomics analysis. We successfully discriminated between significant prostate cancers versus non-tumor regions and provided accurate prediction between Gleason score cohorts with statistical sensitivity of 0.82, 0.81 and 0.91 in three separate pathology classifications. Tumor heterogeneity and prediction of the Gleason score were quantified using two feature selection approaches and two separate classifiers with tuned hyperparameters. There was a total of 71 patients analyzed in this study. Multiparametric MRI, incorporating T2WI and ADC maps, were used to derive radiomics features. Recursive feature elimination (RFE), the least absolute shrinkage and selection operator (LASSO), and two classification approaches, incorporating a support vector machine (SVM) (with randomized search) and random forest (RF) (with grid search), were utilized to differentiate between non-tumor regions and significant cancer while also predicting the Gleason score. In T2WI images, the RFE feature selection approach combined with RF and SVM classifiers outperformed LASSO with SVM and RF classifiers. The best performance was achieved by combining LASSO and SVM into a model that used both T2WI and ADC images. This model had an area under the curve (AUC) of 0.91. Radiomic features computed from ADC and T2WI images were used to predict three groups of Gleason score using two kinds of feature selection methods (RFE and LASSO), RF and SVM classifier models with tuned hyperparameters. Using combined sequences (T2WI and ADC map images) and combined radiomics (1st and GLCM features), LASSO, with a feature selection method with RF, was able to predict G3 with the highest sensitivity at a level AUC of 0.92. To predict G3 for single sequence (T2WI images) using GLCM features, LASSO with SVM achieved the highest sensitivity with an AUC of 0.92.


  • Whole-brain traumatic controlled cortical impact to the left frontal lobe: Magnetic resonance image-based texture analysis

    by Saleh T Alanezi, Waleed M Almutairi, Michelle Cronin, Oliviero Gobbo, Shane M O’mAra, Declan Sheppard, William T O’cOnnor, Michael D Gilchrist, Christoph Kleefeld, Niall Colgan

    This research assesses the capability of texture analysis (TA) derived from high-resolution (HR) T2-weighted magnetic resonance imaging to identify primary sequelae following 1–5 hours of controlled cortical impact mild or severe traumatic brain injury (TBI) to the left frontal cortex (focal impact) and secondary (diffuse) sequelae in the right frontal cortex, bilateral corpus callosum, and hippocampus in rats. The TA technique comprised first-order (histogram-based) and second-order statistics (including gray-level co-occurrence matrix, gray-level run length matrix, and neighborhood gray-level difference matrix). Edema in the left frontal impact region developed within 1 hour and continued throughout the 5-hour assessments. The TA features from HR images confirmed the focal injury. There was no significant difference among radiomics features between the left and right corpus callosum or hippocampus from 1 to 5 hours following a mild or severe impact. The adjacent corpus callosum region and the distal hippocampus region (s), showed no diffuse injury 1–5 hours after mild or severe TBI. These results suggest that combining HR images with TA may enhance detection of early primary and secondary sequelae following TBI.


  • Open Access

    Differential Diagnosis of Prostate Cancer Grade to Augment Clinical Diagnosis Based on Classifier Models With Tuned Hyperparameters

    by S. T. Alanezi, Marcin Jan Kraśny, Christoph Kleefeld, Niall Colgan

    We developed a novel machine learning algorithm to augment clinical diagnosis of prostate cancer utilizing first and second-order texture analysis metrics and novel application of machine learning radiomics analysis. We successfully discriminated between significant prostate cancers versus non-tumor regions and provided accurate prediction between Gleason score cohorts with statistical sensitivity of greater than 0.91 sensitivity across three separate cohorts. Tumor heterogeneity and prediction between GS cohorts were quantified using two feature selection approaches and two classifiers with tuned hyperparameters (including grid search and randomized search). There was a total of 71 patients analyzed in this study. Multiparametric MRI, incorporating T2WI and the ADC maps, were used to derive radiomics features. Recursive feature elimination (RFE), the least absolute shrinkage and selection operator (LASSO), and two classification approaches, including a support vector machine (SVM) (with grid search) and random forest (RF) (with randomized search), were utilized to differentiate between non-tumor regions versus significant cancer and prediction among Gleason score groups. In T2WI images, the RFE feature selection approach combined with RF and SVM classifiers outperformed LASSO with SVM and RF classifiers regarding performance. The detection precision of the radiomics framework depending on multiple imaging modalities was lower than the diagnostic accuracy of single imaging modality model with every machine learning approach assessed. The best performance was achieved by combining LASSO and SVM into a model that used both T2WI and ADC. This model had an area under the curve (AUC) of 0.91. Radiomic features computed from ADC and T2WI images were used to predict three groups of Gleason score using two kinds of feature selection methods (RFE and LASSO), RF and SVM classifier models with tuned hyperparameters. Using combined sequences (T2WI and ADC map images) and combined radiomics (1st and GLCM features), LASSO, with a feature selection method with RF, was able to predict G3 with the highest sensitivity at a level AUC of 0.92. To predict G3 for single sequence (T2WI images) using GLCM features, LASSO with SVM achieved the highest sensitivity with an AUC of 0.92.


  • Open Access

    Quantifying Tumor Heterogeneity from Multiparametric Magnetic Resonance Imaging of Prostate Using Texture Analysis

    by Saleh T. Alanezi, Frank Sullivan, Christoph Kleefeld, John F. Greally, Marcin J. Kraśny, Peter Woulfe, Declan Sheppard, Niall Colgan

    (1) Background: Multiparametric MRI (mp-MRI) is used to manage patients with PCa. Tumor identification via irregular sampling or biopsy is problematic and does not allow the comprehensive detection of the phenotypic and genetic alterations in a tumor. A non-invasive technique to clinically assess tumor heterogeneity is also in demand. We aimed to identify tumor heterogeneity from multiparametric magnetic resonance images using texture analysis (TA). (2) Methods: Eighteen patients with prostate cancer underwent mp-MRI scans before prostatectomy. A single radiologist matched the histopathology report to single axial slices that best depicted tumor and non-tumor regions to generate regions of interest (ROIs). First-order statistics based on the histogram analysis, including skewness, kurtosis, and entropy, were used to quantify tumor heterogeneity. We compared non-tumor regions with significant tumors, employing the two-tailed Mann–Whitney U test. Analysis of the area under the receiver operating characteristic curve (ROC-AUC) was used to determine diagnostic accuracy. (3) Results: ADC skewness for a 6 × 6 px filter was significantly lower with an ROC-AUC of 0.82 (p = 0.001). The skewness of the ADC for a 9 × 9 px filter had the second-highest result, with an ROC-AUC of 0.66; however, this was not statistically significant (p = 0.08). Furthermore, there were no substantial distinctions between pixel filter size groups from the histogram analysis, including entropy and kurtosis. (4) Conclusions: For all filter sizes, there was poor performance in terms of entropy and kurtosis histogram analyses for cancer diagnosis. Significant prostate cancer may be distinguished using a textural feature derived from ADC skewness with a 6 × 6 px filter size.