SBSteven W. Brown

Steven W. Brown

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Steven W. Brown has a total of 91 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Consideration of Correlations in Radiometric Measurements of the Environment

    by Steven W. Brown, Maritoni A. Litorja, Julia K. Marrs, David W. Allen

    Vicarious calibration is a technique that makes use of radiometrically stable targets such as dry lakebeds, desert sites, and open grasslands for the post-launch calibration of a satellite sensor. Top-of-the-atmosphere radiances or reflectances are provided from those sites for the calibration of a sensor. The reflectance of a remote sensing vicarious calibration site is measured by ratioing the signal from a ground target to the signal from a reference target, often a white panel made of PTFE whose reflectance is known. When physically mapping a vicarious calibration site prior to a satellite sensor overflight, there can be elapsed times between the two measurements as great as 10 min. The solar illumination can vary on time scales relevant to the time between measurements of a ground target and a reference panel, impacting the variance in the measured reflectance. In this work, we explore the impact of a temporal delay between two measurements taken outdoors on the Type A uncertainties in their ratios. A factor of 3 reduction in the Coefficient of Variation of the ratio taken simultaneously versus sequentially with delays on the order of 10 min was realized. Implications for protocols employed to measure the surface reflectance at sites used for the vicarious calibration of aircraft and satellite sensors are discussed.

  • Open Access

    Consideration of Correlations in Radiometric Measurements of the Environment

    by Steven W. Brown, Maritoni A. Litorja, Julia K. Marrs, David W. Allen

    Vicarious calibration is a technique that makes use of radiometrically stable targets such as high-altitude dry lakebeds and north African desert sites for the post-launch calibration of a satellite sensor. Top-of-the-atmosphere radiances or reflectances are provided for the calibration of the sensor. The reflectance of a remote sensing vicarious calibration site is measured by ratioing the signal from a ground target to the signal from a reference artifact whose reflectance is known. There can be elapsed times between measurements of a reference artifact on the order of 10 min. For environmental measurements, the solar illumination can vary on time scales relevant to the delay between measurements of a target and a reference artifact, impacting the variance in the measured reflectance. In this work, we explore the impact of a temporal delay between two measurements taken outdoors on the Type A uncertainties in their ratios. A factor of 3 reduction in the Coefficient of Variation of the ratio taken simultaneously versus sequentially with delays on the order of 10 min was realized. Implications for protocols employed to measure the surface reflectance at sites used for the vicarious calibration of aircraft and satellite sensors are discussed.

  • Development of an Uncertainty Budget for a Disseminated Lunar Irradiance Scale Over the Visible to Near-Infrared Spectral Region

    by Steven W. Brown, Truman Wilson, Xiaoxiong Xiong, John T. Woodward, Amit Angal, Junqiang Sun

    This work develops a framework for the development of an SI-traceable model of lunar irradiance over the visible to near-infrared spectral region and provides an estimate of the uncertainties in the disseminated scale. The lunar model, called the Common Lunar Model-ROLO (CLM-R), is based on revisions to the Robotic Lunar Observatory (ROLO) model of lunar reflectance developed by the United States Geological Survey. Inputs from several different instruments are included in its development: SI-traceable lunar measurements by the airborne-LUnar Spectral Irradiance (air-LUSI) instrument are used to establish the absolute scale and give an estimate of the phase correction to ROLO and residual corrections to the ROLO model for lunar libration angles are developed using long-term lunar data sets from Moderate Resolution Imaging Spectrometers (MODIS) on NASA’s Terra and Aqua satellites. Based on lunar measurements by MODIS and Visible Infrared Imaging Radiometers (VIIRS) on NOAA’s Suomi National Polar-orbiting Partnership and NOAA-20 satellites, a combined standard uncertainty less than 1 % for lunar calibrations of satellite sensors may be achievable.


  • Open Access

    Development of an uncertainty budget for a disseminated lunar irradiance scale over the visible to near-infrared spectral region

    by Steven Brown, John T. Woodward, Truman Wilson, Xiaxiong Xiong, Amit Angal, Junqiang Sun

    This work develops a framework for the development of an SI-traceable model of lunar irradiance over the visible to near-infrared spectral region. Based on revisions to the Robotic Lunar Observatory (ROLO) model of lunar reflectance developed by the United States Geological Survey, it is called the Common Lunar Model-ROLO (CLM-R). Inputs from several different instruments are included in its development: SI-traceable lunar measurements by the airborne-LUnar Spectral Irradiance (air-LUSI) instrument are used for an estimate of the phase correction to ROLO while residual corrections to the ROLO model for lunar phase and libration angles are developed using long-term lunar data sets from Moderate Resolution Imaging Spectrometers (MODIS) on NASAâ\euro™s Terra and Aqua satellites and Visible Infrared Imaging Radiometers (VIIRS) on NOAAâ\euro™s Suomi National Polar-orbiting Partnership and NOAA-20 satellites. Additionally, this work examines the potential use of the Moon as an absolute, SI-traceable, celestial calibration target by providing an estimate of the uncertainty in a sensor calibration using the Moon. Based on lunar measurements by MODIS and VIIRS, a combined standard uncertainty less than 1 % is achievable for the calibrations of satellite sensors using the Moon.Â

  • Open Access

    The irradiance instrument subsystem (IRIS) on the airborne-lunar spectral irradiance (air-LUSI) instrument

    by Steven E Grantham, Kevin R Turpie, Thomas C Stone, S Andrew Gadsden, Thomas C Larason, Clarence J Zarobila, Stephen E Maxwell, John T Woodward, Steven W Brown

    The objective of the airborne lunar spectral irradiance (air-LUSI) project is to make low uncertainty, SI-traceable measurements of the LUSI in the visible to near-infrared region from an aircraft above most of the optically absorbing components of the atmosphere. The measurements are made from a NASA ER-2 aircraft, which can fly at altitudes of approximately 20 km above sea level. Air-LUSI measurements, corrected for residual atmospheric attenuation, are designed to provide a matrix of low uncertainty top-of-the-atmosphere lunar irradiances at known lunar phase and libration angles to be compared and combined with other lunar irradiance data sets to constrain the uncertainties in models of lunar irradiance and reflectance. The measurements are also expected to provide insight into the differences between models and satellite sensor measurements of lunar irradiance. This paper describes the development and characterization of the air-LUSI subsystem for acquiring lunar measurements, called the irradiance instrument subsystem, prior to flight.


  • Comparison of two methodologies for calibrating satellite instruments in the visible and near-infrared

    by Robert A. Barnes, Steven W. Brown, Keith R. Lykke, Bruce Guenther, James J. Butler, Thomas Schwarting, Kevin Turpie, David Moyer, Frank DeLuccia, Christopher Moeller

    Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance responsivity in a two-step method. In the first step, the relative spectral response (RSR) of the instrument is determined using a nearly monochromatic light source such as a lamp-illuminated monochromator. These sources do not typically fill the field of view of the instrument nor act as calibrated sources of light. Consequently, they only provide a relative (not absolute) spectral response for the instrument. In the second step, the instrument views a calibrated source of broadband light, such as a lamp-illuminated integrating sphere. The RSR and the sphere’s absolute spectral radiance are combined to determine the absolute spectral radiance responsivity (ASR) of the instrument. More recently, a full-aperture absolute calibration approach using widely tunable monochromatic lasers has been developed. Using these sources, the ASR of an instrument can be determined in a single step on a wavelength-by-wavelength basis. From these monochromatic ASRs, the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as lamp-illuminated integrating spheres. In this work, the traditional broadband source–based calibration of the Suomi National Preparatory Project Visible Infrared Imaging Radiometer Suite sensor is compared with the laser-based calibration of the sensor. Finally, the impact of the new full-aperture laser-based calibration approach on the on-orbit performance of the sensor is considered.


  • Open Access

    A new method for spectral irradiance and radiance responsivity calibrations using kilohertz pulsed tunable optical parametric oscillators

    by Yuqin Zong, Steven W Brown, George P Eppeldauer, Keith R Lykke, Yoshi Ohno


  • Results from solar reflective band end-to-end testing for VIIRS F1 sensor using T-SIRCUS

    by Jeff McIntire, David Moyer, James K. McCarthy, Steven W. Brown, Keith R. Lykke, Frank De Luccia, Xiaoxiong Xiong, James J. Butler, Bruce Guenther

    Verification of the Visible Infrared Imager Radiometer Suite (VIIRS) End-to-End (E2E) sensor calibration is highly recommended before launch, to identify any anomalies and to improve our understanding of the sensor onorbit calibration performance. E2E testing of the Reflective Solar Bands (RSB) calibration cycle was performed pre-launch for the VIIRS Flight 1 (F1) sensor at the Ball Aerospace facility in Boulder CO in March 2010. VIIRS reflective band calibration cycle is very similar to heritage sensor MODIS in that solar illumination, via a diffuser, is used to correct for temporal variations in the instrument responsivity. Monochromatic light from the NIST T-SIRCUS (Traveling Spectral Irradiance and Radiance Responsivity Calibrations using Uniform Sources) was used to illuminate both the Earth View (EV), via an integrating sphere, and the Solar Diffuser (SD) view, through a collimator. The collimator illumination was cycled through a series of angles intended to simulate the range of possible angles for which solar radiation will be incident on the solar attenuation screen on-orbit. Ideally, the measured instrument responsivity (defined here as the ratio of the detector response to the at-sensor radiance) should be the same whether the EV or SD view is illuminated. The ratio of the measured responsivities was determined at each collimator angle and wavelength. In addition, the Solar Diffuser Stability Monitor (SDSM), a ratioing radiometer designed to track the temporal variation in the SD Bidirectional Reflectance Factor (BRF) by direct comparison to solar radiation, was illuminated by the collimator. The measured SDSM ratio was compared to the predicted ratio. An uncertainty analysis was also performed on both the SD and SDSM calibrations.


  • Space-based photometric precision from ground-based telescopes

    by Peter C. Zimmer, John T. Mcgraw, Mark R. Ackermann, Dean C. Hines, Anthony B. Hull, Lisa Rossmann, Daniel C. Zirzow, Steven W. Brown, Claire E. Cramer, Gerald T. Fraser, et al.

    Ground-based telescopes supported by lidar and spectrophotometric auxiliary instrumentation can attain space-based precision for all-sky photometry, with uncertainties dominated by fundamental photon counting statistics. Earth's atmosphere is a wavelength-, directionally- and time-dependent turbid refractive element for every ground-based telescope, and is the primary factor limiting photometric measurement precision. To correct accurately for the transmission of the atmosphere requires direct measurements of the wavelength-dependent transmission in the direction and at the time that the supported photometric telescope is acquiring its data. While considerable resources have been devoted to correcting the effects of the atmosphere on angular resolution, the effects on precision photometry have largely been ignored. We describe the facility-class lidar that observes the stable stratosphere, and a spectrophotometer that observes NIST absolutely calibrated standard stars, the combination of which enables fundamentally statistically limited photometric precision. This inexpensive and replicable instrument suite provides the lidar-determined monochromatic absolute transmission of Earth's atmosphere at visible and near-infrared wavelengths to 0.25% per airmass and the wavelengthdependent transparency to less than 1% uncertainty per minute. The atmospheric data are merged to create a metadata stream that allows throughput corrections from data acquired at the time of the scientific observations to be applied to broadband and spectrophotometric scientific data. This new technique replaces the classical use of nightly mean atmospheric extinction coefficients, which invoke a stationary and plane-parallel atmosphere. We demonstrate application of this instrument suite to stellar photometry, and discuss the enhanced value of routinely provably precise photometry obtained with existing and future ground-based telescopes.


  • Dynamically programmable digital tissue phantoms

    by Steven W Brown, Joseph Paul Rice, David W Allen, Karel J Zuzak, Edward H Livingston, Maritoni Litorja

    As optical imaging modalities gain acceptance for medical diagnostics and become common in clinical applications, standardized protocols to quantitatively assess optical sensor performance are required to ensure commonality in measurements and to validate system performance. The current emphasis is on the development of 3-dimensional, tissue-simulating artifacts with optical scattering and absorption properties designed to closely mimic biological systems. These artifacts, commonly known as tissue phantoms, can be fairly complex and are tailored for each specific application. In this work, we describe a conceptually simpler, 2-dimensional digital analog to the 3-dimensional tissue phantoms that we call Digital Tissue Phantoms. The Digital Tissue Phantoms are complex, realistic, calibrated, optical projections of medically relevant images with known spectral and spatial content. By generating a defined set of Digital Tissue Phantoms, the radiometric performance of the optical imaging sensor can be quantified, based on the accuracy of measurements of the projected images. The system is dynamically programmable, which means that the same system can be used with different sets of Digital Tissue Phantoms for sensor performance metrics covering a wide range of optical medical diagnostics, from cancer and tumor detection to burn quantification.