Antonietta Melenzane
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Antonietta Melenzane has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Mazzucco
Eye Clinic, Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, 80131 Naples, Italy
1 shared publication - Ciro Caruso
Clinica Oculistica, Pellegrini Hospital, ASL Napoli 1, Italy
1 shared publication - Ciro Costagliola
Eye Clinic, Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples Federico II, 80131 Naples, Italy
1 shared publication - Daniela Montorio
Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples “Federico II”, Naples, Italy
1 shared publication - Domenico Solari
Università degli Studi di Napoli Federico II
1 shared publication Fausto Tranfa
Eye Clinic Department of Neurosciences, Reproductive Sciences and Dentistry University of Naples "Federico II" Naples Italy
1 shared publication
Latest Publications
- Open Access
- 24 March 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (7) , 1785
Topographic Outcomes in Keratoconus Surgery: Epi-on versus Epi-off Iontophoresis Corneal Collagen Cross-Linking
Background: Corneal collagen cross-linking (CXL) has become the gold standard for mild and moderate stages to stop the progression of keratoconus. We analyzed some corneal topography indices to compare iontophoresis epi-on and iontophoresis epi-off techniques throughout a two-year follow-up. Methods: A total of 64 eyes of 49 patients who underwent CXL were recruited. In 30 eyes the epi-off technique was performed, whereas the remaining 34 eyes were treated with the epi-on technique. All patients underwent a complete ophthalmologic examination that included CDVA, central and thinnest corneal thickness, Schirmer test I, TBUT test, and the Ocular Surface Disease Index. Results: In both groups, a significant improvement in visual function was recorded. No statistically significant differences between Kmax, Mean K, Flat K, Steep K values were found. Statistically significant differences (p < 0.05) between the epi-on and epi-off groups’ pachymetry before and after 24 months follow-up as well as between the epi-on and epi-off groups’ topographically thinnest point in the immediate post-surgery and 24 months after surgery were recorded. Conclusion: Our study highlighted that both techniques are valid in mid-term corneal stabilization. The advantage of the new iontophoresis epi-off cross-linking technique could be found in a faster imbibing time of the cornea, therefore reducing surgical times, with a lower risk of complications.
- 24 March 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (7) , 1785
Open AccessTopographic Outcomes in Keratoconus Surgery: Epi-on versus Epi-off Iontophoresis Corneal Collagen Cross-Linking
Background: Corneal collagen cross-linking (CXL) has become the gold standard for mild and moderate stages to stop the progression of keratoconus. We analyzed some corneal topography indices to compare iontophoresis epi-on and iontophoresis epi-off techniques throughout a two-year follow-up. Methods: A total of 64 eyes of 49 patients who underwent CXL were recruited. In 30 eyes the epi-off technique was performed, whereas the remaining 34 eyes were treated with the epi-on technique. All patients underwent a complete ophthalmologic examination that included CDVA, central and thinnest corneal thickness, Schirmer test I, TBUT test, and the Ocular Surface Disease Index. Results: In both groups, a significant improvement in visual function was recorded. No statistically significant differences between Kmax, Mean K, Flat K, Steep K values were found. Statistically significant differences (p < 0.05) between the epi-on and epi-off groups’ pachymetry before and after 24 months follow-up as well as between the epi-on and epi-off groups’ topographically thinnest point in the immediate post-surgery and 24 months after surgery were recorded. Conclusion: Our study highlighted that both techniques are valid in mid-term corneal stabilization. The advantage of the new iontophoresis epi-off cross-linking technique could be found in a faster imbibing time of the cornea, therefore reducing surgical times, with a lower risk of complications.
- Open Access
- 29 October 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (10) , e0241295
Early vascular modifications after endoscopic endonasal pituitary surgery: The role of OCT-angiography
The aim of the present study is to analyze the changes in retinal vessel density (VD), using Optical Coherence Tomography Angiography (OCT-A), in patients that received endoscopic endonasal approach for the removal of an intra-suprasellar pituitary adenoma compressing optic chiasm. We evaluated the VD in Superficial Capillary Plexus (SCP), Deep Capillary Plexus (DCP), Radial Peripapillary Capillary (RPC) and the Foveal Avascular Zone (FAZ) area in a series of fourteen patients (7 males, 7 females, mean age 56 ± 13 years), as compared to healthy controls. We also detected the structural Spectral Domain (SD)-OCT parameters: Ganglion Cell Complex (GCC), Retinal Nerve Fiber Layer (RNFL), visual field parameters (Mean Deviation, Pattern Standard Deviation) and Best Corrected Visual Acuity (BCVA). These measurements were performed prior than surgery and 48 hours after. The patients showed a significant decrease in VD of the macular and papillary regions, a significant increase in FAZ area, a significant impairment in SD-OCT, VF parameters and BCVA respect to 14 eyes of 14 healthy controls (p<0.05), at pre-op evaluation. In patients group the VD in SCP, DCP and RPC increased after surgery respect to baseline but the difference turned to be out statistically significant only in RPC (p = 0.003). Also the BCVA (p = 0.040) and the Mean Deviation at visual field (p = 0.015) significantly improved after surgery. While there was a reduction in structural OCT parameters but it was statistically significant only in GCC (p = 0.039). A positive correlation was found between the preoperative VD of the RPC, Mean Deviation, BCVA and the postoperative Mean Deviation (r = 0.426 p = 0.027; r = 0.624 p = 0.001; r = 0.515 p = 0.006). OCT-A allows to detect the early changes occurring within 48 hours after surgery showing that the improvement in retinal vessel density could occur before the recovery of the structural OCT parameters and can be a positive predictive factor for the functional recovery.
- 29 October 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (10) , e0241295
Open AccessEarly vascular modifications after endoscopic endonasal pituitary surgery: The role of OCT-angiography
The aim of the present study is to analyze the changes in retinal vessel density (VD), using Optical Coherence Tomography Angiography (OCT-A), in patients that received endoscopic endonasal approach for the removal of an intra-suprasellar pituitary adenoma compressing optic chiasm. We evaluated the VD in Superficial Capillary Plexus (SCP), Deep Capillary Plexus (DCP), Radial Peripapillary Capillary (RPC) and the Foveal Avascular Zone (FAZ) area in a series of fourteen patients (7 males, 7 females, mean age 56 ± 13 years), as compared to healthy controls. We also detected the structural Spectral Domain (SD)-OCT parameters: Ganglion Cell Complex (GCC), Retinal Nerve Fiber Layer (RNFL), visual field parameters (Mean Deviation, Pattern Standard Deviation) and Best Corrected Visual Acuity (BCVA). These measurements were performed prior than surgery and 48 hours after. The patients showed a significant decrease in VD of the macular and papillary regions, a significant increase in FAZ area, a significant impairment in SD-OCT, VF parameters and BCVA respect to 14 eyes of 14 healthy controls (p<0.05), at pre-op evaluation. In patients group the VD in SCP, DCP and RPC increased after surgery respect to baseline but the difference turned to be out statistically significant only in RPC (p = 0.003). Also the BCVA (p = 0.040) and the Mean Deviation at visual field (p = 0.015) significantly improved after surgery. While there was a reduction in structural OCT parameters but it was statistically significant only in GCC (p = 0.039). A positive correlation was found between the preoperative VD of the RPC, Mean Deviation, BCVA and the postoperative Mean Deviation (r = 0.426 p = 0.027; r = 0.624 p = 0.001; r = 0.515 p = 0.006). OCT-A allows to detect the early changes occurring within 48 hours after surgery showing that the improvement in retinal vessel density could occur before the recovery of the structural OCT parameters and can be a positive predictive factor for the functional recovery.