JZJinquan Zhao

Jinquan Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinquan Zhao has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental and Numerical Investigations of Seismic Performance of Prefabricated SRC Frame in Multi-Floored Grain Warehouse

    by Qiang Li, Yonggang Ding, Guoqi Ren, Jinquan Zhao, Qikeng Xu, Zhenhua Xu

    As an innovative structural system aligned with construction industrialization, prefabricated Steel-Reinforced Concrete (SRC) structures are characterized by high load-bearing capacity, efficient material utilization, and rapid construction. In this study, the mechanical behavior, failure mechanisms, and ductility characteristics of a prefabricated SRC multi-floored grain warehouse frame were investigated through quasi-static cyclic loading tests. To complement the experimental program, high-fidelity numerical models were developed using Abaqus, incorporating concrete plastic damage and steel material nonlinearity. The simulation results were rigorously validated against the experimental data. The findings indicate that the specimens exhibited typical shear failure modes with full hysteretic loops, demonstrating substantial energy dissipation capacity (equivalent viscous damping coefficient of 0.261). Notably, the results of the parametric study indicate that the integration of wall panels can significantly increase the load-bearing capacity and lateral stiffness of the frame system. The ductility of the samples was excellent, with displacement ductility coefficients ranging from 3.1 to 3.7. The ultimate inter-story drift angles at failure (1/49–1/38) substantially exceeded the code-specified limit (1/50), indicating robust collapse-prevention capacity. The numerical results strongly agreed with the experimental observations in terms of the hysteretic behavior, failure patterns, and skeleton curves, confirming the reliability of the modeling strategy for subsequent seismic performance analyses and parametric evaluations.

  • Experimental and numerical studies on connection performance of sandwich insulation composite wall of prefabricated grain storehouse

    by Jin‐Quan Zhao, Chao‐Hui Yang, Yong‐Gang Ding, Qing‐Jun Xian, Jie Dai, Cheng‐Zhou Guo, Zhen‐Hua Xu

    In response to the national strategy of “green storage”, this study developed an innovative technology combining spiral hooped rebar and grout splicing to create a new prefabricated grain storehouse structural system. A 1:2 scale model of the column‐wall substructure was designed and fabricated for static testing. Combined with finite element analysis, the study examines the connection performance of the new grout splicing method. The results showed that the load at which horizontal cracks formed was 310 kN, three times the design grain pressure. The connections were reliable and the overall integrity was good. The number of grout splices at the horizontal wall seams directly affects the deformation capacity and the stress distribution of the rebars and grout material. As the number of grout splices decreased, the decline rates of both the cracking load and the ultimate load under normal service conditions were controlled within 5%, while the decline rates of yield load and the ultimate load were maintained below 10%. It is recommended that the number of joints be optimized to three‐quarters of full staggered splice requirements.

  • Experimental study on bond–slip constitutive relationship of spiral hooped rebar‐bellow grout splicing

    by Jin‐Quan Zhao, Chao‐Hui Yang, Zhen‐Hua Xu, Cheng‐Zhou Guo, Long Zhou

    To investigate the bond stress–slip constitutive relation of the spiral hooped rebar‐bellow grout splicing connection, 21 sets of specimens and six sets of slotting rebar were designed and fabricated. The bond stress–slip behavior between the rebar and the grouting material confined by the spiral hooped rebar‐metal bellow was studied through pull‐out tests. Based on the experimental results, the strain distribution of the slotting rebar along the anchorage length was analyzed, and the bond stress distribution curve along the anchorage length was obtained. Furthermore, the bond stress and relative slip relationship between the rebar and grouting material considering positional relationships was proposed. Finally, a bond stress–slip constitutive relation that considers the positional function and is established between the rebar and grouting material confined by spiral hooped rebar‐metal bellow was proposed. The results indicate that as the anchorage length increases, the rebar strain gradually decreases. Under different levels of load, the bond stress distribution along the anchorage length exhibits a single‐peak, non‐uniform pattern, reaching a peak near the loaded end, while the bond stress distribution from the midsection to the free end is relatively uniform. The positional function also exhibits a single‐peak, non‐uniform distribution, reaching a peak at 0.3 times the anchorage length (0.3 l a ) near the loaded end, and its distribution shape is related to the anchorage length. The bond stress–slip constitutive relation between the rebar and grouting material established using the positional function effectively reflects the bond stress distribution pattern along the anchorage length.

  • Open Access

    Seismic Response Analysis of Multi-Floored Grain Warehouses with Composite Structures Under Varying Grain-Loading Conditions

    by Zidan Li, Yonggang Ding, Jinquan Zhao, Chengzhou Guo, Zhenhua Xu, Guoqi Ren, Qikeng Xu, Qingjun Xian, Rongyu Yang

    Multi-floored grain warehouses are widely used in China due to their efficient space utilization and high storage capacity. This study evaluates the seismic performance of such structures using a Composite Structure of Steel and Concrete (CSSC) system under various grain-loading conditions. A finite element model was developed in OpenSees based on actual loading scenarios, with both pushover and time history analyses conducted. Results show that the EEF condition (E = Empty, F = Full; top–middle–bottom = Empty–Empty–Full) leads to a 35.14% increase in peak base shear compared to the FEE condition (grain on the top floor only). Capacity spectrum analysis indicates that EEF provides higher initial stiffness and lower displacement across all performance points. Time history results reveal that configurations with lighter upper mass (EFF, EEE) are more prone to top-floor acceleration amplification, while FFF and FFE demonstrate more stable responses due to balanced mass distribution. The maximum inter-story drift consistently occurs at the second floor, with FFF and FFE showing the most significant deformation. All drift ratios meet code limits, confirming the safety and applicability of the CSSC system under various storage scenarios.

  • Open Access

    Seismic performance and damage model of prefabricated SRC joints in multi-floored grain warehouse

    by Zidan Li, Yonggang Ding, Jinquan Zhao, Chengzhou Guo, Zhenhua Xu, Guoqi Ren, Qikeng Xu, Qingjun Xian, Rongyu Yang

    The multi-floored grain warehouse (MGW) has been widely used in China due to its high space utilization and large storage capacity. To optimize the structure of these warehouses and reduce the amount of on-site wet work, this study proposed a new prefabricated SRC (steel-reinforced concrete) beam-column-slab joint connection for MGWs. Three new SRC spatial joint specimens were designed and tested under cyclic loading to investigate their performance under different grain storage conditions. The results showed that the hysteresis curves of the specimens were similar across all conditions, with failure modes primarily characterized by plastic hinge formation at the beam ends. As the grain storage amount increased, significant strain accumulation occurred in the reinforcement and steel sections at both the joint and beam ends, leading to evidently earlier yielding. A finite element model of the specimens was established using Abaqus for parametric analysis, which showed that grain load significantly affected the bolt tension force. Additionally, based on multiple SRC beam-column joint seismic performance test datasets and the mechanical properties of SRC structures, a Park-Ang modified damage model for SRC beam-column joints was proposed. The reliability of the newly introduced combination coefficient was validated, demonstrating that the proposed damage model could effectively predict joint damage.

  • Open Access

    Multidimensional Seismic Response Analysis of Large-Scale Steel-Reinforced Concrete Frame-Bent Structures in CAP1400 Nuclear Power Plant

    by Zhenhua Xu, Jinquan Zhao, Guoliang Bai, Yonggang Ding

    Irregularity in the plane layout of a building structure and the vertical discontinuity of lateral resistance components could lead to torsion and result in the brittle failure of a structure. According to the characteristics of the conventional island main building of nuclear power plants, this paper focuses on the conventional island main building of the CAP1400 nuclear power plant (NPP) in Shidaowan as the research object. A prototype structure model of the main building was developed using ABAQUS software. The seismic response of the structure under multidimensional ground motion was studied by inputting the X-direction and Y-direction translational and torsional components of ground motion in ABAQUS. The results demonstrate that the overall transverse displacement of the structure under bidirectional ground motion was significantly higher than that under unidirectional earthquakes, which was about 20%. Under a multidimensional frequent earthquake, the transverse displacement of the structure increased by about 13% on average compared with that under a bidirectional earthquake; the longitudinal increase was the largest, at about 28%. Finally, the lateral displacement of each layer of the steel-reinforced concrete (SRC) frame-bent main building structure with few walls proposed in this article decreased by an average of about 17% compared to the traditional SRC frame-bent main building structure. The longitudinal displacement was reduced by about 14% compared to the traditional SRC frame-bent main building structure.


  • Open Access

    Influence of Glazed Hollow Bead on the Performance of Polyvinyl Alcohol Fiber Reinforced Cement Composites

    by Jie Dai, Xuesen Li, Yadi Zhao, Yunfei Li

    To improve the thermal insulation properties and toughness of concrete, the glazed hollow bead (GHB) and polyvinyl alcohol (PVA) fiber reinforced cementitious composites (GPCC) were investigated by orthogonal test, which includes six GHB mass percentage (20%, 40%, 60%, 80%,100%, 120%), three PVA volume fraction (1%, 1.5%, 2%) and water binder ratio (0.26, 0.30, 0.34). Compressive, split tensile strengths and thermal conductivity of GHB-PVA reinforced cementitious composites (GPCC) were tested, and the mechanism of fibers was analyzed from a microscopic perspective. The results revealed that the thermal insulation will be significantly improved with the increased content of GHB, but the compressive and split tensile strength will be decreased simultaneously. No obvious effect was found by the PVA fiber addition on its strength indexes, and the presence of GHB will affect the bridging action of PVA fibers. The water binder ratio has more effect on strengths than thermal conductivity. Based on the mechanical performance rather than the thermal insulation analysis test, the optimal mix proportions were proposed: mass percentage of 40% GHB, a volume fraction of 1.5% PVA fiber, and 0.26 water-binder ratio. Moreover, the anchoring and bridging effect of PVA fibers will effectively balance the stress generated by the shrinkage of cement paste, and inhibits or even prevents the development of cracks. However, a certain number of tiny cracks will be formed near the GHB, and between GHB and PVA fibers, which will cause local stretching and peeling of PVA, and shattering inside the GHB with the increase of external force. The findings of this study can provide a useful reference for the application of an insulated-bearing material with GHB and PVA fiber.


  • Open Access

    Experimental Study on Mechanical Properties of Integrated Wall Panels of Grain Warehouse with “Thermal Insulation”

    by Xuesen Li, Yonggang Ding, Jinquan Zhao, Qikeng Xu

    The walls of grain cottage silos are still being built by clay brick masonry featured with single‐structure form, poor air tightness, large workload of manual masonry on site, and huge consumption of raw materials and burning materials, which is not conducive to energy saving and environmental protection. In order to study the mechanical function of the new wall under the action of grain side pressure, the static loading test was conducted on the model of scaled‐down wall panel under the action of side pressure. The damage process, the damage pattern, and the bearing capacity of the wall panel were studied through the analysis of the crack development process and distribution law to reveal the force characteristics of the wall panel. The test results show that the span deflection of the “structure‐insulation” integrated wall panel under the lateral pressure meets the requirement of the limit state of normal use; the inner and outer leaf wall panels can work together under the action of the joint; the ratio of the load borne by the inner and outer leaf wall panels is equal to the ratio of their stiffness; the flexural stiffness of the wall panels after cracking is proposed based on the combined effect analysis. Based on the analysis of the combined effect, the degradation factor of the wall panel after cracking is proposed, and the deflection calculation formula of the inner and outer leaf wall panel is established, which provides a theoretical basis for the design and the promotion of the “structure‐insulation” integrated wall panel.