Zachary Taylor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zachary Taylor has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Aleksi Tamminen
Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland
12 shared publications - Juha Ala-Laurinaho
Department of Electronics and Nanoengineering, Aalto University, Espoo, Finland
12 shared publications - Irina Nefedova
Department of Electronics and Nanoengineering, MilliLab, Aalto University, Espoo, Finland
8 shared publications - Mariangela Baggio
Electronics and Nanoengineering, Aalto University School of Electrical Engineering, 126176 Espoo, Finland, 02150
7 shared publications - Roman Grigorev
Department of Electronics and Nanoengineering, MilliLab, Aalto University, Aalto, Finland
6 shared publications - Emma Pickwell-MacPherson
University of Warwick
5 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 16 (10) , 1041-1044
Editorial: 3rd Special Issue on Selected Emerging Trends in Terahertz Science and Technology
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 16 (10) , 1041-1044
Editorial: 3rd Special Issue on Selected Emerging Trends in Terahertz Science and Technology
- Open Access
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 6 (5) , 1132-1143
Corneal Dosimetry in the 200–500 GHz Band Using Generalized Lorenz–Mie Theory
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 6 (5) , 1132-1143
Open AccessCorneal Dosimetry in the 200–500 GHz Band Using Generalized Lorenz–Mie Theory
- Open Access
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 16 (4) , 357-365
Perturbed Resonance Frequency Analysis for Imaging Epidermal Thickness and Water Content Using Terahertz Spectroscopy
In this study, we propose a novel perturbed resonance frequency analysis method where the modified, THz frequency, Fabry–P´ erot resonances of a tissue loaded quartz window are used to quantify superficial skin layer thickness and water content. The superficial layer is treated as an unknown matching layer between the quartz window and deep epidermis and resolution of the longitudinal modes provides a unique mapping from resonance frequency and width to layer water content and thickness. The approach is experimentally validated with a telecentric beam scanning system coupled to VNA extender operating in the 330– 500 GHz band. The system is used to observe the dynamic effects of stinging nettle exposure on in vivo human skin over a 52 x 52 mm2 field-of-view (FOV). Spectroscopic imaging revealed an immediate decrease in resonance frequency and width of up to 15 GHz and 20 GHz, respectively, compared to unperturbed skin, which maps to a 30μm increase in thickness and 25% decrease in water content. This immediate response was followed by a gradual recovery to pre-exposed values. These findings demonstrate additional dielectric window utility in terahertz biomedical spectroscopy in imaging beyond the standard field flattening and system calibration roles.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 16 (4) , 357-365
Open AccessPerturbed Resonance Frequency Analysis for Imaging Epidermal Thickness and Water Content Using Terahertz Spectroscopy
In this study, we propose a novel perturbed resonance frequency analysis method where the modified, THz frequency, Fabry–P´ erot resonances of a tissue loaded quartz window are used to quantify superficial skin layer thickness and water content. The superficial layer is treated as an unknown matching layer between the quartz window and deep epidermis and resolution of the longitudinal modes provides a unique mapping from resonance frequency and width to layer water content and thickness. The approach is experimentally validated with a telecentric beam scanning system coupled to VNA extender operating in the 330– 500 GHz band. The system is used to observe the dynamic effects of stinging nettle exposure on in vivo human skin over a 52 x 52 mm2 field-of-view (FOV). Spectroscopic imaging revealed an immediate decrease in resonance frequency and width of up to 15 GHz and 20 GHz, respectively, compared to unperturbed skin, which maps to a 30μm increase in thickness and 25% decrease in water content. This immediate response was followed by a gradual recovery to pre-exposed values. These findings demonstrate additional dielectric window utility in terahertz biomedical spectroscopy in imaging beyond the standard field flattening and system calibration roles.
- Open Access
- 21 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
Roadmap towards personalized approaches and safety considerations in non-ionizing radiation: from dosimetry to therapeutic and diagnostic applications
This roadmap provides a comprehensive and forward-looking perspective on the individualized application and safety of non-ionizing radiation (NIR) dosimetry in diagnostic and therapeutic medicine. Covering a wide range of frequencies, i.e., from low-frequency to terahertz, this document provides an overview of the current state of the art and anticipates future research needs in selected key topics of NIR-based medical applications. It also emphasizes the importance of personalized dosimetry, rigorous safety evaluation, and interdisciplinary collaboration to ensure safe and effective integration of NIR technologies in modern therapy and diagnosis.
- 21 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
Open AccessRoadmap towards personalized approaches and safety considerations in non-ionizing radiation: from dosimetry to therapeutic and diagnostic applications
This roadmap provides a comprehensive and forward-looking perspective on the individualized application and safety of non-ionizing radiation (NIR) dosimetry in diagnostic and therapeutic medicine. Covering a wide range of frequencies, i.e., from low-frequency to terahertz, this document provides an overview of the current state of the art and anticipates future research needs in selected key topics of NIR-based medical applications. It also emphasizes the importance of personalized dosimetry, rigorous safety evaluation, and interdisciplinary collaboration to ensure safe and effective integration of NIR technologies in modern therapy and diagnosis.
- Open Access
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 16 (3) , 258-271
Quasioptic, Calibrated, Full 2-Port Measurements of Cryogenic Devices Under Vacuum in the 220–330 GHz Band
A quasi-optical (QO) test bench was designed, simulated, and calibrated for characterizing all four S-parameters of devices in the 220–330 GHz (WR3.4) frequency range, from room temperature down to 4.8 K. Quasioptical calibration methods were applied to de-embed the impact of cryostat and optical elements on device under test measurements. The devices were measured through vacuum windows via focused beam radiation. A de-embedding method employing line-reflect-match (LRM) calibration was established to account for the effects of optical components and vacuum windows. Such a method does not require multiple line standards inside the cryostat and mechanical translation of quasioptics. System validation was performed with measurements of cryogenically cooled devices, such as bare silicon wafers and stainless-steel frequency-selective surface (FSS) bandpass filters, and superconducting bandpass FSS fabricated in niobium. A permittivity reduction of Si based on a 4 GHz resonance shift was observed concomitant with a drop in temperature from 296 to 4.8 K. The stainless steel FSS measurements revealed a relatively temperature invariant center frequency and return loss level of 263 GHz and 35 dB on average, respectively. Finally, a center frequency of 257 GHz was measured with the superconducting filters, with return loss improved by 11 dB on average at 4.8 K. To the best of our knowledge, this is the first reported attempt to scale LRM calibration to 330 GHz and use it to de-embed the impact of optics and cryostat from cryogenically cooled device S-parameters.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 16 (3) , 258-271
Open AccessQuasioptic, Calibrated, Full 2-Port Measurements of Cryogenic Devices Under Vacuum in the 220–330 GHz Band
A quasi-optical (QO) test bench was designed, simulated, and calibrated for characterizing all four S-parameters of devices in the 220–330 GHz (WR3.4) frequency range, from room temperature down to 4.8 K. Quasioptical calibration methods were applied to de-embed the impact of cryostat and optical elements on device under test measurements. The devices were measured through vacuum windows via focused beam radiation. A de-embedding method employing line-reflect-match (LRM) calibration was established to account for the effects of optical components and vacuum windows. Such a method does not require multiple line standards inside the cryostat and mechanical translation of quasioptics. System validation was performed with measurements of cryogenically cooled devices, such as bare silicon wafers and stainless-steel frequency-selective surface (FSS) bandpass filters, and superconducting bandpass FSS fabricated in niobium. A permittivity reduction of Si based on a 4 GHz resonance shift was observed concomitant with a drop in temperature from 296 to 4.8 K. The stainless steel FSS measurements revealed a relatively temperature invariant center frequency and return loss level of 263 GHz and 35 dB on average, respectively. Finally, a center frequency of 257 GHz was measured with the superconducting filters, with return loss improved by 11 dB on average at 4.8 K. To the best of our knowledge, this is the first reported attempt to scale LRM calibration to 330 GHz and use it to de-embed the impact of optics and cryostat from cryogenically cooled device S-parameters.
- Open Access
- 12 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 15 (5) , 787-799
A Telecentric Offset Reflective Imaging System (TORIS) for Terahertz Imaging and Spectroscopy
Terahertz (THz) imaging has emerged as a promising technology in medical diagnostics, thanks to non-ionizing radiation and the high sensitivity of THz waves to water content. However, traditional THz imaging systems face challenges such as slow mechanical scanning, limited field-of-view, and poor telecentricity. To address these limitations, we present the telecentric offset reflective imaging system, a novel dual-mirror scanning design optimized for high-speed, distortion-free imaging. Utilizing a telecentric $f-\theta$ lens and ray-tracing and physical optics simulations, the system achieves uniform resolution across a 50×50 mm2 field of view without mechanical translation stages. The system demonstrates its capability through broadband spectral imaging of a USAF resolution test target across WR-2.2 (325 - 500 GHz) and WR-1.5 (500 - 700 GHz) rectangular waveguide frequency bands, achieving consistent beam focus and minimal distortion, with maximum deviation of 2.7$^{\circ }$ from normal incidence and beam waist of 2.1$\lambda$ at the edge of the field of view in WR- 1.5 frequency band. Additionally, the system's ability to monitor hydration dynamics is validated by imaging wet tissue paper, illustrating its sensitivity to temporal changes in water content. Further, in vivo imaging of human skin after capsaicin patch application reveals localized hydration variations influenced by biochemical responses and adhesive patch removal. These results confirm the scanner's potential for real-time hydration sensing and dermatological assessments. By providing high-resolution, real-time THz imaging, TORIS establishes a new standard in THz-based spectroscopy and imaging, with applications spanning clinical diagnostics, wound assessment, and material characterization.
- 12 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 15 (5) , 787-799
Open AccessA Telecentric Offset Reflective Imaging System (TORIS) for Terahertz Imaging and Spectroscopy
Terahertz (THz) imaging has emerged as a promising technology in medical diagnostics, thanks to non-ionizing radiation and the high sensitivity of THz waves to water content. However, traditional THz imaging systems face challenges such as slow mechanical scanning, limited field-of-view, and poor telecentricity. To address these limitations, we present the telecentric offset reflective imaging system, a novel dual-mirror scanning design optimized for high-speed, distortion-free imaging. Utilizing a telecentric $f-\theta$ lens and ray-tracing and physical optics simulations, the system achieves uniform resolution across a 50×50 mm2 field of view without mechanical translation stages. The system demonstrates its capability through broadband spectral imaging of a USAF resolution test target across WR-2.2 (325 - 500 GHz) and WR-1.5 (500 - 700 GHz) rectangular waveguide frequency bands, achieving consistent beam focus and minimal distortion, with maximum deviation of 2.7$^{\circ }$ from normal incidence and beam waist of 2.1$\lambda$ at the edge of the field of view in WR- 1.5 frequency band. Additionally, the system's ability to monitor hydration dynamics is validated by imaging wet tissue paper, illustrating its sensitivity to temporal changes in water content. Further, in vivo imaging of human skin after capsaicin patch application reveals localized hydration variations influenced by biochemical responses and adhesive patch removal. These results confirm the scanner's potential for real-time hydration sensing and dermatological assessments. By providing high-resolution, real-time THz imaging, TORIS establishes a new standard in THz-based spectroscopy and imaging, with applications spanning clinical diagnostics, wound assessment, and material characterization.
- Open Access
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (11) , 3221-3232
A Dual-Purpose Microwave-Optical Component for Wireless Capsule Endoscopy: A Feasibility Study by Radio Link Analysis
Wireless capsule endoscopy (WCE) is the only option for non-invasive small intestine disease diagnostics. However, the small size of the capsules poses a major design challenge for engineers since multiple optical and electrical components must reside inside the capsules. This article proposes a space-saving dual-purpose component utilized in both optical image capturing and microwave wireless data transmission of a WCE capsule at the 915 MHz industrial-scientific-medical band. The optical performance is verified through ray-tracing simulations, whereas the microwave operation is demonstrated by full-wave impedance simulations and by conducting a radio link simulation and measurement with an up-scaled prototype. The results show that the proposed component can be utilized in capsule optics to achieve an acceptable imaging quality. Furthermore, the component operates as an antenna, providing adequate link gains for WCE wireless communications.
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (11) , 3221-3232
Open AccessA Dual-Purpose Microwave-Optical Component for Wireless Capsule Endoscopy: A Feasibility Study by Radio Link Analysis
Wireless capsule endoscopy (WCE) is the only option for non-invasive small intestine disease diagnostics. However, the small size of the capsules poses a major design challenge for engineers since multiple optical and electrical components must reside inside the capsules. This article proposes a space-saving dual-purpose component utilized in both optical image capturing and microwave wireless data transmission of a WCE capsule at the 915 MHz industrial-scientific-medical band. The optical performance is verified through ray-tracing simulations, whereas the microwave operation is demonstrated by full-wave impedance simulations and by conducting a radio link simulation and measurement with an up-scaled prototype. The results show that the proposed component can be utilized in capsule optics to achieve an acceptable imaging quality. Furthermore, the component operates as an antenna, providing adequate link gains for WCE wireless communications.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 15 (3) , 370-378
Gouy Phase Correction for Quasioptical, Dielectric Spectroscopy of Spherical Shells in a Gaussian Beam for Terahertz Corneal Sensing
This study aims to explore the effect of the Gouy phase shift correction on determining refractive index and physical thickness of concentric spherical shells measured by quasioptical terahertz (THz) spectroscopy. The shells consisted of a loss-free quartz layer sitting on a water core which serves as an aqueous half space similar to the cornea's aqueous humour. The reflection of the water-backed quartz shells were measured with a focused Gaussian beam in the 220–330 GHz range. The optics generated a beam with a frequency-independent confocal distance resulting in equal radius of curvature and thus optimal wavefront matching to the sample curvature across the band. Thickness and refractive index were estimated from the measurements using Fresnel's equations and a fixed phase velocity. Parameter extraction was performed a second time where the frequency and axial location dependent phase velocity was corrected by incorporating the expected Gouy phase shift. The correction improved both the thickness and refractive index accuracy. The utility of Gouy phase correction was explored on hydrated corneal phantoms and increased the accuracy of thickness, and anterior and posterior water content estimates.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 15 (3) , 370-378
Gouy Phase Correction for Quasioptical, Dielectric Spectroscopy of Spherical Shells in a Gaussian Beam for Terahertz Corneal Sensing
This study aims to explore the effect of the Gouy phase shift correction on determining refractive index and physical thickness of concentric spherical shells measured by quasioptical terahertz (THz) spectroscopy. The shells consisted of a loss-free quartz layer sitting on a water core which serves as an aqueous half space similar to the cornea's aqueous humour. The reflection of the water-backed quartz shells were measured with a focused Gaussian beam in the 220–330 GHz range. The optics generated a beam with a frequency-independent confocal distance resulting in equal radius of curvature and thus optimal wavefront matching to the sample curvature across the band. Thickness and refractive index were estimated from the measurements using Fresnel's equations and a fixed phase velocity. Parameter extraction was performed a second time where the frequency and axial location dependent phase velocity was corrected by incorporating the expected Gouy phase shift. The correction improved both the thickness and refractive index accuracy. The utility of Gouy phase correction was explored on hydrated corneal phantoms and increased the accuracy of thickness, and anterior and posterior water content estimates.
- 9 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 14 (5) , 553
Editorial Special Issue on Selected Emerging Trends in Terahertz Science and Technology
- 9 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 14 (5) , 553
Editorial Special Issue on Selected Emerging Trends in Terahertz Science and Technology
- 4 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 44 (10) , 1716-1719
Fivefold Peak Power Boost in HBT-Driven GaAs Collapsing-Field-Domain-Based Sub-THz Source
Miniature on-chip sources based on the collapsing field domain phenomenon in GaAs have advanced compact sub-picosecond time-domain imaging schemes operating in the 100-250 GHz frequency range. Efforts have been done to broaden the emission band of on-chip sources towards 400 GHz, but increasing the peak power of the emitted picosecond-range pulses remains physically challenging but practically important. In this work, a fivefold increase in peak power has been achieved by replacing the previously used hetero-bipolar-based collapsing field domain source operating in self-oscillating mode with a bipolar-based source externally pulsed by a hetero-bipolar driver. Importantly, the suggested solution unaffected the compactness of the source and facilitates its application in time domain imaging.
- 4 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 44 (10) , 1716-1719
Fivefold Peak Power Boost in HBT-Driven GaAs Collapsing-Field-Domain-Based Sub-THz Source
Miniature on-chip sources based on the collapsing field domain phenomenon in GaAs have advanced compact sub-picosecond time-domain imaging schemes operating in the 100-250 GHz frequency range. Efforts have been done to broaden the emission band of on-chip sources towards 400 GHz, but increasing the peak power of the emitted picosecond-range pulses remains physically challenging but practically important. In this work, a fivefold increase in peak power has been achieved by replacing the previously used hetero-bipolar-based collapsing field domain source operating in self-oscillating mode with a bipolar-based source externally pulsed by a hetero-bipolar driver. Importantly, the suggested solution unaffected the compactness of the source and facilitates its application in time domain imaging.