Pengyu Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pengyu Ye has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Zhiyong Hou
Department of Orthopedic Surgery, Hebei Medical University Third Hospital
4 shared publications - Yingze Zhang
Nankai University, Tianjin, China
3 shared publications - Zhongzheng Wang
Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, People’s Republic of China
3 shared publications - Kuo Zhao
Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei
2 shared publications - Siyu Tian
Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, People’s Republic of China
2 shared publications - Yingchao Yin
Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, China
2 shared publications
Latest Publications
- Open Access
- 20 October 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 3556357
Displacement Pattern of Anterior and Posterior Column Fragments in Both‐Column Acetabular Fractures: A 3D Reconstruction‐Based Study
Background. Few studies have been conducted to examine the displacement characteristics of both‐column acetabular fractures (BCAFs). The goal of this study was to investigate the displacement pattern of anterior column (AC) and posterior column (PC) fragments in BCAFs using 3D virtual software. Materials and Methods. BCAFs were retrospectively reviewed, and 81 patients were enrolled. Computed tomography (CT) images were imported into Mimics software. A 3D model of each pelvis was generated. Four marked points and the rotation angle of each of the injured ACs and PCs were identified. The fracture fragments were reduced virtually using the software, and the change in coordinates of the marked points after reduction was recorded while the rotation angle was measured. The measurements of positional and directional displacement were analysed using the Mann–Whitney U test and the binomial test, respectively. Results. There was a propensity for AC fragments to shift superomedially and to rotate externally (p < 0.001). Additionally, the posteroinferior fracture area of AC fragments showed the greatest displacement (p < 0.05). PC fragments moved superomedially (p < 0.001) and moved more at the proximal end than the distal end (p < 0.001). PC displacement was always accompanied by internal rotation (p < 0.001). Greater AC displacement was observed in the fracture area further away from the acetabulum (p < 0.05). Greater rotation was observed for the AC than the PC (p < 0.001). Conclusion. After a BCAF occurs, there are regular patterns regarding the direction and distance of AC and PC fragment displacement. Information on these patterns may provide insight into the injury mechanism and fracture morphology and facilitate surgical decision‐making for orthopaedic trauma surgeons.
- 20 October 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 3556357
Open AccessDisplacement Pattern of Anterior and Posterior Column Fragments in Both‐Column Acetabular Fractures: A 3D Reconstruction‐Based Study
Background. Few studies have been conducted to examine the displacement characteristics of both‐column acetabular fractures (BCAFs). The goal of this study was to investigate the displacement pattern of anterior column (AC) and posterior column (PC) fragments in BCAFs using 3D virtual software. Materials and Methods. BCAFs were retrospectively reviewed, and 81 patients were enrolled. Computed tomography (CT) images were imported into Mimics software. A 3D model of each pelvis was generated. Four marked points and the rotation angle of each of the injured ACs and PCs were identified. The fracture fragments were reduced virtually using the software, and the change in coordinates of the marked points after reduction was recorded while the rotation angle was measured. The measurements of positional and directional displacement were analysed using the Mann–Whitney U test and the binomial test, respectively. Results. There was a propensity for AC fragments to shift superomedially and to rotate externally (p < 0.001). Additionally, the posteroinferior fracture area of AC fragments showed the greatest displacement (p < 0.05). PC fragments moved superomedially (p < 0.001) and moved more at the proximal end than the distal end (p < 0.001). PC displacement was always accompanied by internal rotation (p < 0.001). Greater AC displacement was observed in the fracture area further away from the acetabulum (p < 0.05). Greater rotation was observed for the AC than the PC (p < 0.001). Conclusion. After a BCAF occurs, there are regular patterns regarding the direction and distance of AC and PC fragment displacement. Information on these patterns may provide insight into the injury mechanism and fracture morphology and facilitate surgical decision‐making for orthopaedic trauma surgeons.
- Open Access
- 9 July 2022
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 36, 1-7
Treatment of tibial plateau fractures: A comparison of two different operation strategies with medium-term follow up
- 9 July 2022
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 36, 1-7
Open AccessTreatment of tibial plateau fractures: A comparison of two different operation strategies with medium-term follow up
- Open Access
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 9212895
Morphological Characteristics of the Posterior Wall Associated with Complex Acetabular Fractures: A Radiological Study Using 3D Software and Fracture Mapping Technique
Background. The aim of the study was to compare the morphological distinctions of the posterior wall (PW) in different complex acetabular fractures using 3D software and fracture mapping technique and ultimately to provide for improved clinical treatment. Methods. One hundred and fourteen patients with complex acetabular fracture associated with PW were recruited. All patients were divided into two groups according to the injury mechanism of the PW: Group A (both‐column and PW) and Group B (including posterior column and PW; T shape and PW; and transverse and PW). Fracture mapping was generated on the intra‐ and extrasurface of a standard template. The radiological parameters including spatial displacement, articular surface area, articular range, marginal impaction, and multifragments of the two groups were compared. Results. The spatial displacement, intra‐/extra‐articular surface area, and start and end point in Group A were 10.9 mm (IQR, 8.4‐15.2), 8.2 ± 2.6 cm2, 17.9 ± 5.3 cm2, 0.8° (IQR, ‐6.0‐16.2), and 107.5° (IQR, 97.2‐116.9), respectively. The results in Group B were 30.4 mm (IQR, 16.8‐48.7), 4.1 ± 2.0 cm2, 10.6 ± 4.4 cm2, 29.5° (IQR, 19.2‐38.0), and 117.5° (IQR, 98.2‐127.2), respectively. Marginal impaction was defined by Letournel et al. All the differences between two groups were significant (P < 0.05). The fracture map in Group A showed an “L”‐shaped pattern and a “cusp” on the ilium, and the PW was located at 1/5 to 1/4 of the posterosuperior part of the acetabulum. The fracture maps in Group B were scattered and lacked consistency, and the PWs were confined to 1/10 to 1/8 of the posterior acetabulum. Conclusions. Quantitative measurements and fracture mapping represented the differences in morphological characteristics of PWs associated with complex acetabular fractures.
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 9212895
Open AccessMorphological Characteristics of the Posterior Wall Associated with Complex Acetabular Fractures: A Radiological Study Using 3D Software and Fracture Mapping Technique
Background. The aim of the study was to compare the morphological distinctions of the posterior wall (PW) in different complex acetabular fractures using 3D software and fracture mapping technique and ultimately to provide for improved clinical treatment. Methods. One hundred and fourteen patients with complex acetabular fracture associated with PW were recruited. All patients were divided into two groups according to the injury mechanism of the PW: Group A (both‐column and PW) and Group B (including posterior column and PW; T shape and PW; and transverse and PW). Fracture mapping was generated on the intra‐ and extrasurface of a standard template. The radiological parameters including spatial displacement, articular surface area, articular range, marginal impaction, and multifragments of the two groups were compared. Results. The spatial displacement, intra‐/extra‐articular surface area, and start and end point in Group A were 10.9 mm (IQR, 8.4‐15.2), 8.2 ± 2.6 cm2, 17.9 ± 5.3 cm2, 0.8° (IQR, ‐6.0‐16.2), and 107.5° (IQR, 97.2‐116.9), respectively. The results in Group B were 30.4 mm (IQR, 16.8‐48.7), 4.1 ± 2.0 cm2, 10.6 ± 4.4 cm2, 29.5° (IQR, 19.2‐38.0), and 117.5° (IQR, 98.2‐127.2), respectively. Marginal impaction was defined by Letournel et al. All the differences between two groups were significant (P < 0.05). The fracture map in Group A showed an “L”‐shaped pattern and a “cusp” on the ilium, and the PW was located at 1/5 to 1/4 of the posterosuperior part of the acetabulum. The fracture maps in Group B were scattered and lacked consistency, and the PWs were confined to 1/10 to 1/8 of the posterior acetabulum. Conclusions. Quantitative measurements and fracture mapping represented the differences in morphological characteristics of PWs associated with complex acetabular fractures.