OKOlga Kramar

Olga Kramar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Olga Kramar has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Performance characteristics of drills with different geometries for dental implantation in unfavorable anatomical conditions with a consistent drilling protocol with a minimum step of increasing the diameter of the drill

    by O.O. Yanushevich, N.I. Krikheli, A.V. Isaev, P.YU. Peretyagin, O.V. Kramar, A.M. Panin, A.M. Tsitsiashvili, D.A. Lezhnev, A.A. Ershov, M.N. Bychkova, et al.

    Four surgical osseodensification drills with different geometric parameters were designed and manufactured from martensitic stainless steel (equivalent to AISI 420) with a wear-resistant titanium nitride (TiN) coating applied by physical vapor deposition (PVD). For the experimental study, bone samples (blocks) were prepared from cattle ribs, corresponding to C. Misch’s D3—D4 bone type, which is commonly found in the distal jaws. The processed samples were divided into groups according to the previously assigned surgical drill number. After every 4th osteotomy, an optical assessment of the cutting edge wear was performed using a scanning electron microscope and the change in bone tissue temperature was determined using a K-type thermocouple. Our experimental study on cattle ribs confirms the complex influence of the osseodensification drill geometry on the heating of bone tissue and its density estimated by Hounsfield unit (HU) value during the preparation of a dental implant bed using a sequential drilling protocol with a minimal step of increasing the working diameter of the drill. Surgical drills made of AISI 420 steel with a TiN (PVD) coating showed no wear after 24 osteotomies, which is comparable to the reference Densah drills. Drill with the largest clearance and helix angles, provides the best thermal conditions during the osteodensification procedure. Drills with a clearance angle α =20° provided a 2—6 times higher densification increase than drills with an α=6°. Drills with α=20° increased bone density by 34—51%, while those with α=6° increased density by only 7—20%. Further studies to refine and validate the obtained models of functional relationships, including the use of experimental drills using other drilling protocols, seem relevant.

  • Development of a technology for manufacturing nanostructured ceramic CAD/CAM blanks for dentistry

    by O. O. Yanushevich, N. I. Krikheli, P. Yu. Peretyagin, I. V. Klizhov, A. T. Sampiev, O. V. Kramar, N. Yu. Peretyagin, A. A. Shein

    Technical innovation plays a key role in modern life, and it is precisely this innovation that has driven the development of digital technologies in dentistry. In the 1980s, CAD/CAM systems emerged in dental practice. These systems reduced manual workload and offered such qualities as precision, ergonomics, cleanliness, versatility, and high productivity. These systems became extremely popular among doctors and patients, ushering in a new era of dental care. The significant popularity of CAD/CAM technologies in dentistry and their demand served as the basis for the development of a domestic technology for the production of nanostructured ceramic CAD/CAM blanks for dentistry. In the previous phase of the study, the influence of spray drying parameters on the characteristics of the resulting powders was studied, and various powder sintering methods, such as free-flow and spark plasma sintering (SPS), were analyzed to achieve ideal density, mechanical strength, and crack resistance [7]. As part of the current stage of work, it is planned to manufacture experimental samples of CAD/CAM blanks from ceramic composites based on zirconium dioxide.

  • A comparative review of the physical and chemical characteristics of titanium and zirconium dioxide used for the production of dental implants

    by О. О. Yanushevich, N. I. Krikheli, P. Yu. Peretyagin, A. M. Tsitsiashvili, O. V. Kramar, N. Yu. Peretyagin, P. A. Naumenko, M. N. Bychkova, E. V. Kuznetsova, N. V. Solis Pinargote

    Taking into account the continuing search for the optimal material for the production of dental implants, it seems relevant to compare, according to the literature, the physico-chemical properties (mechanical properties, osseointegration ability, fatigue endurance of titanium (cpTi grade 1-4, Ti-6Al-4V) and yttrium-stabilized zirconium dioxide (ZrO 2 ) used for the production of dental implants. The analysis of published experimental clinical papers (in vitro, in vivo), studies using simulations based on the finite element method. The review shows a comparable ability to osseointegration in both materials, zirconium dioxide demonstrates a higher modulus of elasticity and hardness, but increased sensitivity to fatigue. Titanium retains the advantage of plasticity and proven long-term operation. Thus, titanium remains the most versatile and predictable material, while zirconium implants are a real and promising alternative for a number of clinical cases.


  • Open Access

    Design and Mechanical Properties of ZTA–Niobium Composites with Reduced Graphene Oxide

    by Sergey Grigoriev, Oleg Yanushevich, Natella Krikheli, Olga Kramar, Yuri Pristinskiy, Nestor Washington Solis Pinargote, Pavel Peretyagin, Anton Smirnov

    Niobium–graphene oxide–zirconia-toughened alumina (ZTA) composites were produced by wet mixing and spark plasma sintering. The microstructure and mechanical properties of this novel composite have been studied. The results show that niobium particles are homogeneously dispersed in the ZTA matrix. Raman spectroscopy confirmed the thermal reduction in graphene oxide during sintering. The presence of ductile metal and graphene flakes leads to an increase in the crack resistance value of the ZTA matrix. The developed composites demonstrate a fracture toughness of 16 MPa∙m1/2, which is three times higher than ZTA ceramic composites. The high toughness values found in this new composite are a consequence of the strong interaction between the simultaneous action of several toughening mechanisms, specifically involving crack trapping, crack blunting, crack renucleation, and the bridging mechanisms of the metallic and graphene particles. Moreover, this increase has also occurred due to the enhancement of the transformability of zirconia in ceramic–metal composites.


  • Materials for the manufacture of dental implants (literature review)

    by O. O. Yanushevich, N. I. Krikheli, P. Yu. Peretyagin, O. V. Kramar, A. M. Tsitsiashvili, I. P. Aleksashina, Yu. I. Zhukovskaya, Ю. И. Жуковская

       The purpose of this study was to analyze various literature sources, giving an exhaustive overview of the characteristics of all structural materials currently used in the manufacture of dental implants, which will also determine the trend of new developments in materials science in dental implantology. The research material included literary data presented in scientific publications indexed in the bibliographic databases PubMed, ScienceDirect and E-library, using the keywords isolated and their combinations in Russian and English « dental implants, titanium, zirconium, ceramics, tantalum, biocompatibility, osteointegration, graphene» as search terms. The results showed that the use of all existing materials and technological processes for the production of dental implants is justified. To date, the task of further scientific research in this field is to search for and/ or create a material that meets all the necessary operational requirements for a dental implant, has greater biocompatibility, less toxic effects on the body or its absence, providing optimal functional and aesthetic properties, at the lowest possible cost of manufacturing the product. Studies of ceramic-metal materials with the addition of graphene are promising, as currently studies show its high potential acceptability for integration in the development of new materials and technological processes for the production of dental implants.

  • Development of domestic CAD/CAM blanks for dentistry

    by O. O. Yanushevich, N. I. Krikheli, I. V. Klizhov, A. T. Sampiev, O. V. Kramar, P. Yu. Peretyagin

    Разработка отечественных CAD/CAM заготовок для стоматологии


  • Open Access

    Concept and Design of Cutting Tools for Osseodensification in Implant Dentistry

    by Alexander Isaev, Maria Isaeva, Oleg Yanushevich, Natella Krikheli, Olga Kramar, Aleksandr Tsitsiashvili, Sergey Grigoriev, Catherine Sotova, Pavel Peretyagin

    Osseodensification is an innovative surgical instrumentation technique based on additive (non-cutting) drilling using special burs. It is known from the literature, that the osseodensification burs should operate in a clockwise direction to drill holes and in a counterclockwise direction to compact the osteotomy walls. For these purposes, the burs have special design features, like conical contour shape, increased number of helical flutes, and negative rake angle on the peripheral part. However, although other parameters and features of the burs define their overall performance, they are not described sufficiently, and their influence on surgical quality is almost unknown both for clinicians and tool manufacturers. The purpose of the present research is to identify the key design features of burs for osseodensification and their functional relationship with the qualitative indices of the procedure based on an analytical review of research papers and patent documents. It will help to further improve the design of osseodensification burs and thereby enhance the surgical quality and, ultimately, patient satisfaction. Results: The most important design features and parameters of osseodensification burs are identified. Thereon, the structural model of osseodensification bur is first represented as a hypergraph. Based on the analysis of previous research, functional relationships between design parameters of osseodensification burs, osseodensification procedure conditions, and procedure performance data were established and, for the first time, described in the comprehensive form of a hypergraph. Conclusions: This study provides formal models that form the basis of database structure and its control interface, which will be used in the later developed computer-aided design module to create advanced types of burs under consideration. These models will also help to make good experimental designs used in studies aimed at improving the efficiency of the osseodensification procedure.

  • Open Access

    Influence of Nitride Coatings on Corrosion Resistance and the Biocompatibility of Titanium Alloy Products

    by Catherine Sotova, Oleg Yanushevich, Natella Krikheli, Olga Kramar, Alexey Vereschaka, Semen Shehtman, Filipp Milovich, Valery Zhylinski, Anton Seleznev, Pavel Peretyagin

    The bioadhesion of bacteria to the surface of samples with Ti–TiN, Zr–ZrN, Zr–(Zr, Nb)N, and Zr–(Zr, Hf)N coatings was studied via incubation with gram-positive strains of Staphylococcus aureus. The samples were kept at 25 °C for 30 days in a 3% NaCl solution. The deposition of coatings slows, whereas oxidation processes intensify. The oxygen content on the TiN and (Zr, Nb)N coating surfaces was higher than that of the Ti sample without a coating. Samples with ZrN and, especially, (Zr, Hf)N coatings resist oxidation better. Regarding bioactivity toward S. aureus, the highest density of biological forms was observed on the surfaces of TiN and (Zr, Hf)N coatings. The lowest density was on the surfaces of uncoated, ZrN-coated, and (Zr, Nb)N-coated samples. On Ti–TiN, Zr–ZrN, and Zr–(Zr, Nb)N coatings, the formation of surface biostructures of a filamentary type was observed. In the uncoated sample, the biostructures have an island character, and in the sample with a Zr–(Zr, Hf)N coating, the formation of extensive areas of biostructures was observed. Between the biostructures and coating, a layer 5 to 15 nm thick was observed, presumably associated with bacterial adhesion. The presence of biostructures on the coating surface can activate or slow oxidation processes.


  • Prospects for developing domestic instruments for dental implantation in various clinical conditions

    by O.O. Yanushevich, N.I. Krikheli, A.M. Tsitsiashvili, P.YU. Peretyagin, M.N. Bychkova, O.V. Kramar

    The paper reviews the prospects of developing universal rotating cutting tools of Russian production for the surgical stage of dental implantation in patients with toothlessness in various clinical settings. The advantages and disadvantages of the available dental implantation techniques, as well as methods for the formation of the dental implant bed, are noted. As the most promising type of universal rotary cutting tool, a cutting tool has been identified that allows forming the dental implant bed according to the classical protocol and, additionally, if necessary, compacting bone tissue and/or expanding the outer walls along the periphery and towards the bottom of the dental implant bed. Surface modification and improvement of the physical and mechanical properties of the designated cutting tool are possible using physical vacuum deposition technology.


  • Application of light-cured nanofilled composite materials in dentistry (literature review)

    by N. I. Krikheli, M. N. Bychkova, O. V. Kramar, O. V. Rudneva, P. Yu. Peretyagin, N. Yu. Peretyagin, Н. Ю. Перетяги

    Currently, patients are increasingly turning to dentists with complaints about unsatisfactory dental aesthetics. All this is associated with both carious and non-carious lesions of the teeth. Methods of dental treatment today are diverse and satisfy the desires of even the most fastidious patient. So, in the treatment of dental caries, dentists prefer filling. All kinds of composite materials, mainly of foreign production, are used for sealing. Due to the changed global trends, we are faced with the task of finding and developing a new domestic nanofilled light-curing composite that will not be inferior in its properties and composition to leading foreign analogues.