ABAna Luisa Cassiano Alves Bezerra

Ana Luisa Cassiano Alves Bezerra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ana Luisa Cassiano Alves Bezerra has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The pH of Bleaching Gels on the Structural and Biological Response of Dental Tissues: A Scoping Review

    by Jamile Menezes de Souza, Maria Olimpia Paz Alvarenga, Ana Luisa Cassiano Alves Bezerra, Gabriela Queiroz de Melo Monteiro

    Objective: This scoping review aimed to map and synthesize the available evidence on the influence of the bleaching gel pH on the structural and biological responses of dental tissues.Overview: A comprehensive search was conducted across five databases and one grey literature source. Studies comparing bleaching gels with acidic pH versus neutral or basic pH in human teeth, in both clinical and laboratory settings, were included. A total of 20,282 articles were identified, 72 were selected for full‐text reading, and 22 studies met the eligibility criteria. Most studies evaluated bleaching efficacy, while others investigated tooth sensitivity, enamel surface alterations, and penetration of hydrogen peroxide into the pulp chamber. Among the four randomized clinical trials included, two studies reported that bleaching gels with an acidic pH were associated with a higher risk and intensity of tooth sensitivity compared to those with a neutral, stable pH. Laboratory studies consistently demonstrated greater enamel surface alterations and higher hydrogen peroxide diffusion with acidic pH levels (< 7 pH). However, a few studies found no significant differences related to pH.Conclusions: The pH of bleaching gels plays a critical role in the biological and structural integrity of dental tissues. Although several in vitro studies highlight the risks associated with acidic gels, clinical data remain limited. Given the widespread use of acidic pH gels in dental practice, further randomized clinical trials are needed to determine their safety and to guide evidence‐based recommendations on pH control in bleaching protocols.Clinical Significance: Whitening gels with acidic pH can increase enamel alterations and hydrogen peroxide penetration, potentially leading to higher tooth sensitivity. However, clinical evidence is limited. Given their widespread use, further randomized clinical trials are needed to confirm risks and guide safer bleaching protocols.


  • Open Access

    Eficácia de polimerização de aparelhos fotopolimerizadores utilizados em clínica escola de Odontologia do Recife

    by Ana Luisa Cassiano Alves Bezerra, María Olimpia Paz Alvarenga, Márcia de Almeida Durão, Gabriela Queiroz de Melo Monteiro, Tereza Januária Costa Dias

    O objetivo desse trabalho foi avaliar o estado geral dos diferentes aparelhos fotopolimerizadores utilizados em Clínica Escola de Odontologia da Uninassau-Recife/PE e sua eficácia na polimerização de resinas compostas. Para isto, foi avaliada a irradiância de 18 aparelhos e suas condições de uso quanto à integridade e higienização das ponteiras. Para a análise da eficácia foram confeccionados um total de 15 corpos de prova (Ꝋ 6 mm x 2 mm), com a resina composta Filtek Z250 (3M ESPE, St. Paul, MN, USA). Os corpos de provas foram divididos em 3 grupos (n=5), sendo dois grupos fotoativados com os aparelhos utilizados na instituição, o Biolux Plus (Bioart, São Carlos, Brasil) e o Optilight Max (Gnatus, Barretos, Brasil); e um grupo (controle), utilizado o aparelho Valo Grand Cordless (Ultradent, Indaiatuba, Brasil), sendo submetidos ao teste de microdureza após 24h. Na microdureza, todos os corpos de prova apresentaram maiores médias no topo, sendo mais elevada no grupo controle e menores no grupo Optilight Max, com diferença significativa entre os grupos em cada superfície (p<0,001). A irradiância da maioria dos aparelhos fotoativadores avaliados (72,22%) estava adequada para utilização, apesar da perceptível necessidade de manutenção, pois 44,44% estavam com material resinoso aderido nas ponteiras e 38,89% com ponteiras danificadas. De forma geral, os aparelhos se encontravam apropriados para utilização. As resinas fotoativadas pelos diferentes aparelhos apresentaram microdureza satisfatória em apenas um dos dois dos aparelhos fotopolimerizadores testados, ressaltando a importância da manutenção periódica, bem como da necessidade de esclarecimentos aos acadêmicos sobre sua utilização.