Enhui Yong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Enhui Yong has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Enming Yong
Vascular Surgery Service, Department of General Surgery, Tan Tock Seng Hospital, Singapore
2 shared publications Gabriel Chan
Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore
2 shared publicationsGavin Lim
Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore
2 shared publicationsJustin Kwan
Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore
2 shared publicationsLawrence Han Hwee Quek
Department of Diagnostic Radiology, Tan Tock Seng Hospital, Singapore
2 shared publicationsLester Rhan Chaen Chong
Vascular Surgery Service, Department of General Surgery, Tan Tock Seng Hospital, Singapore
2 shared publications
Latest Publications
- 30 December 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
Cracking the Calcium Barrier: Intravascular Lithotripsy for Peripheral Arterial Disease—1-year Outcomes From 50 Procedures in a Singapore Tertiary Hospital
This study reports our experience with intravascular lithotripsy (IVL) in managing heavily calcified peripheral arterial disease (PAD) at a tertiary center in Southeast Asia. A total of 50 procedures were performed in 49 patients between October 2022 and April 2024. The cohort had a high burden of comorbidities, with 94% presenting with chronic limb-threatening ischemia, 62% classified as wound, ischemia, and foot infection (WIfI) stage 4, and 31% having end-stage renal failure. Severe vascular calcification (Peripheral Artery Calcification Scoring System [PACSS] grade 4) was present in 84% of lesions. IVL was employed as a vessel preparation strategy prior to definitive treatment, with adjunctive therapies used in all cases. Technical success was achieved in 100% of procedures, with a mean luminal gain of 71.4%±21.8%. Bailout stenting was required in 16% of cases, and there were no incidents of distal embolization. At 1-year follow-up, the target lesion revascularization rate was 6.1%, the overall reintervention rate was 14%, limb salvage was 84%, and mortality was 31%. Our findings suggest that IVL is a safe and effective option for vessel preparation in patients with severely calcified PAD, achieving high technical success and favorable mid-term outcomes in a complex, high-risk population. Clinical Impact: Calcified peripheral arterial disease remains a challenging subset in endovascular therapy, often limiting luminal gain, increasing dissection risk, and impairing drug delivery. This single-center experience demonstrates that IVL is a safe and effective vessel-preparation strategy in a real-world population with high comorbidity burden and predominantly PACSS grade 4 disease. IVL achieved 100% technical success, substantial luminal gain, low complication rates; and favorable 1-year limb salvage and reintervention outcomes. These findings support IVL as a practical method for modifying severe calcification and improving procedural reliability in high-risk patients undergoing endovascular treatment.
- 30 December 2025
- Published by SAGE Publications in Journal of Endovascular Therapy
Cracking the Calcium Barrier: Intravascular Lithotripsy for Peripheral Arterial Disease—1-year Outcomes From 50 Procedures in a Singapore Tertiary Hospital
This study reports our experience with intravascular lithotripsy (IVL) in managing heavily calcified peripheral arterial disease (PAD) at a tertiary center in Southeast Asia. A total of 50 procedures were performed in 49 patients between October 2022 and April 2024. The cohort had a high burden of comorbidities, with 94% presenting with chronic limb-threatening ischemia, 62% classified as wound, ischemia, and foot infection (WIfI) stage 4, and 31% having end-stage renal failure. Severe vascular calcification (Peripheral Artery Calcification Scoring System [PACSS] grade 4) was present in 84% of lesions. IVL was employed as a vessel preparation strategy prior to definitive treatment, with adjunctive therapies used in all cases. Technical success was achieved in 100% of procedures, with a mean luminal gain of 71.4%±21.8%. Bailout stenting was required in 16% of cases, and there were no incidents of distal embolization. At 1-year follow-up, the target lesion revascularization rate was 6.1%, the overall reintervention rate was 14%, limb salvage was 84%, and mortality was 31%. Our findings suggest that IVL is a safe and effective option for vessel preparation in patients with severely calcified PAD, achieving high technical success and favorable mid-term outcomes in a complex, high-risk population. Clinical Impact: Calcified peripheral arterial disease remains a challenging subset in endovascular therapy, often limiting luminal gain, increasing dissection risk, and impairing drug delivery. This single-center experience demonstrates that IVL is a safe and effective vessel-preparation strategy in a real-world population with high comorbidity burden and predominantly PACSS grade 4 disease. IVL achieved 100% technical success, substantial luminal gain, low complication rates; and favorable 1-year limb salvage and reintervention outcomes. These findings support IVL as a practical method for modifying severe calcification and improving procedural reliability in high-risk patients undergoing endovascular treatment.
- 26 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (4) , 1365-1376
MR-Conditional Robotic Cardiac Intervention: Design and Validation in Patient-Specific Phantoms
Manual hand-held catheterization by clinicians under Magnetic Resonance Imaging (MRI) has become popular for the treatment of cardiovascular diseases such as pulmonary edema and heart failure. However, the limited space of the MRI bore makes it challenging for clinicians to access the opening, and the prolonged operation can cause back injury. To implement MRI-guided robot-assisted catheterization, this paper presents an MR-conditional robotic system for right heart catheterization (MR-RHC). Our 2-degree-of-freedom (DoF) robotic manipulator is actuated by ultrasonic piezoelectric motors. The highly compact design (D× W× L=11 cm× 8 cm× 18 cm) allows the robot to be positioned in the MRI scanner bore, near the patient’s femoral vein opening. The contribution of this paper lies in the development of an MR-conditional robotic system that clinically required Swan-Ganz catheter movements, including (simultaneous) infinite continuous rotation and translation (i.e., the catheter can perform endless rotation and translation that are not restricted by cable tangling or limited operational motion of the actuators). The MR conditionality of the robotic system is demonstrated in a clinical MR environment. Additionally, the system has been characterized in terms of its force and torque capabilities and verified 100% success rate of tele-intervention within 7 patient specific phantoms. Lastly, the paper reports the intervention of an MRI-guided robot-operated catheter within the water-filled phantoms between the control room and MR scanner.
- 26 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (4) , 1365-1376
MR-Conditional Robotic Cardiac Intervention: Design and Validation in Patient-Specific Phantoms
Manual hand-held catheterization by clinicians under Magnetic Resonance Imaging (MRI) has become popular for the treatment of cardiovascular diseases such as pulmonary edema and heart failure. However, the limited space of the MRI bore makes it challenging for clinicians to access the opening, and the prolonged operation can cause back injury. To implement MRI-guided robot-assisted catheterization, this paper presents an MR-conditional robotic system for right heart catheterization (MR-RHC). Our 2-degree-of-freedom (DoF) robotic manipulator is actuated by ultrasonic piezoelectric motors. The highly compact design (D× W× L=11 cm× 8 cm× 18 cm) allows the robot to be positioned in the MRI scanner bore, near the patient’s femoral vein opening. The contribution of this paper lies in the development of an MR-conditional robotic system that clinically required Swan-Ganz catheter movements, including (simultaneous) infinite continuous rotation and translation (i.e., the catheter can perform endless rotation and translation that are not restricted by cable tangling or limited operational motion of the actuators). The MR conditionality of the robotic system is demonstrated in a clinical MR environment. Additionally, the system has been characterized in terms of its force and torque capabilities and verified 100% success rate of tele-intervention within 7 patient specific phantoms. Lastly, the paper reports the intervention of an MRI-guided robot-operated catheter within the water-filled phantoms between the control room and MR scanner.
- Open Access
- 13 May 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (8) , 103609
Smoking and Coronary Atherosclerosis: Disproportionate Impact on the Right Coronary Artery
- 13 May 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (8) , 103609
Open AccessSmoking and Coronary Atherosclerosis: Disproportionate Impact on the Right Coronary Artery
- Open Access
- 1 January 2025
- Published by BMJ in BMJ Open Quality
- Vol. 14 (1) , e003138
Reducing time for vascular access salvage: initial results from a single institution’s clinical practice improvement programme
Background: One of the most common causes of arteriovenous fistula (AVF) and/or arteriovenous graft (AVG) failure is thrombosis. Guidelines recommend early AVF salvage within 24–48 hours. Our institution reported poor compliance with these recommendations, with a median of 3 days prior to vascular access (VA) salvage. We present our initial results following the implementation of a clinical practice improvement programme (CPIP) to reduce delay to VA salvage. Methods: The CPIP was conducted in three phases: pre-CPIP (23 January to 30 April 2023), CPIP pre-intervention (22 May to 3 September 2023) and CPIP post-intervention (4 September 2023 to 7 January 2024). Root cause analysis was performed to identify factors resulting in VA salvage delay. Measures implemented included a platform for multidisciplinary communication on cases requiring VA salvage, implementation of a structured workflow and regular reminders to ensure compliance. Early salvage was defined as <48 hours from triage at the emergency department. Time from admission to VA salvage, length of stay, incidence of femoral catheter (FC) insertion and overall cost savings were collected. Results: There were 82 patients (90.1%) who received VA salvage during the CPIP period. The median age was 67 years with a male predominance (64%). There were 45 patients (54.9%) who received early VA salvage during CPIP. The run chart showed a median early VA salvage rate of 6.1% for pre-intervention and 81.0% for post-intervention. The median length of stay pre-intervention and post-intervention was 5.65 days and 2.92 days, respectively. The incidence of FC insertion was 17.1% (n=6/35) during CPIP for thrombosed VA. Eight patients failed to obtain early VA salvage during the post-intervention period. Overall hospitalisation cost savings per patient were SGD$3144 lower post-intervention. Conclusion: We report the successful implementation of our CPIP through the involvement of stakeholders and stepwise implementation of measures using a structured protocol.
- 1 January 2025
- Published by BMJ in BMJ Open Quality
- Vol. 14 (1) , e003138
Open AccessReducing time for vascular access salvage: initial results from a single institution’s clinical practice improvement programme
Background: One of the most common causes of arteriovenous fistula (AVF) and/or arteriovenous graft (AVG) failure is thrombosis. Guidelines recommend early AVF salvage within 24–48 hours. Our institution reported poor compliance with these recommendations, with a median of 3 days prior to vascular access (VA) salvage. We present our initial results following the implementation of a clinical practice improvement programme (CPIP) to reduce delay to VA salvage. Methods: The CPIP was conducted in three phases: pre-CPIP (23 January to 30 April 2023), CPIP pre-intervention (22 May to 3 September 2023) and CPIP post-intervention (4 September 2023 to 7 January 2024). Root cause analysis was performed to identify factors resulting in VA salvage delay. Measures implemented included a platform for multidisciplinary communication on cases requiring VA salvage, implementation of a structured workflow and regular reminders to ensure compliance. Early salvage was defined as <48 hours from triage at the emergency department. Time from admission to VA salvage, length of stay, incidence of femoral catheter (FC) insertion and overall cost savings were collected. Results: There were 82 patients (90.1%) who received VA salvage during the CPIP period. The median age was 67 years with a male predominance (64%). There were 45 patients (54.9%) who received early VA salvage during CPIP. The run chart showed a median early VA salvage rate of 6.1% for pre-intervention and 81.0% for post-intervention. The median length of stay pre-intervention and post-intervention was 5.65 days and 2.92 days, respectively. The incidence of FC insertion was 17.1% (n=6/35) during CPIP for thrombosed VA. Eight patients failed to obtain early VA salvage during the post-intervention period. Overall hospitalisation cost savings per patient were SGD$3144 lower post-intervention. Conclusion: We report the successful implementation of our CPIP through the involvement of stakeholders and stepwise implementation of measures using a structured protocol.
- Open Access
- 24 March 2022
- Published by Taylor & Francis in Journal of European CME
- Vol. 11 (1) , 2055266
The European Examination in Core Cardiology in Focus: Evaluation and Recommendations Using Educational Theory
The European Examination in Core Cardiology (EECC) is a knowledge-based postgraduate examination for cardiology specialists in Europe. It is designed to assess if a trainee has gained sufficient knowledge for independent specialist practice in core cardiology. A critical evaluation of the ECCC was undertaken using current educational theory. Miller’s Pyramid was considered, and the Utility Equation was employed in a mixed methods approach. The utility analysis findings were that the EECC measured well on reliability and validity although improvement could be made in educational impact, cost-effectiveness and accessibility. Recommendations for enhancement were then put forward. No assessment instrument is perfect, and it is important to remember that the EECC is one component of assessment strategy for specialist trainees, complementing other evidence of professional competence. After appraisal, while improvement can be made, the EECC fulfils its ambitions of assessment.
- 24 March 2022
- Published by Taylor & Francis in Journal of European CME
- Vol. 11 (1) , 2055266
Open AccessThe European Examination in Core Cardiology in Focus: Evaluation and Recommendations Using Educational Theory
The European Examination in Core Cardiology (EECC) is a knowledge-based postgraduate examination for cardiology specialists in Europe. It is designed to assess if a trainee has gained sufficient knowledge for independent specialist practice in core cardiology. A critical evaluation of the ECCC was undertaken using current educational theory. Miller’s Pyramid was considered, and the Utility Equation was employed in a mixed methods approach. The utility analysis findings were that the EECC measured well on reliability and validity although improvement could be made in educational impact, cost-effectiveness and accessibility. Recommendations for enhancement were then put forward. No assessment instrument is perfect, and it is important to remember that the EECC is one component of assessment strategy for specialist trainees, complementing other evidence of professional competence. After appraisal, while improvement can be made, the EECC fulfils its ambitions of assessment.