FFFernando de Frutos

Fernando de Frutos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fernando de Frutos has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Expectations and Outcomes when Quantifying Energy Improvements Achieved by Building Envelope Retrofitting

    by Fernando Martín-Consuegra, Camila Andrea Ludueña, Fernando De Frutos, Borja Frutos, Carmen Alonso, Ignacio Oteiza

    This paper assesses the energy efficiency of two buildings constructed in the 1960s in Madrid. One of the buildings is refurbished including passive energy efficiency improvements, while the other remains in its original state. The area is one of a series of low-income residential inefficient developments built by the state on the capital’s outskirts in the 1950s. Their buildings require huge amounts of energy to meet occupants’ basic energy needs. This paper quantifies the energy savings and improved comfort achieved by building envelope energy retrofitting. For this purpose, it proposes a comprehensive methodology spanning data monitoring in homes in buildings, occupant surveys and energy simulation models—a standard approach to estimating improvement potential. Our aim is to compare the expected energy savings predicted by energy certificates with monitored data. The paper concludes that the comfort level in the retrofitted building improved tangibly but that the differing behaviours of the building’s occupants make the energy saving difficult to quantify with any precision. The calibrated model targets energy consumption savings after renovation of approximately 25% in heating and 50% in cooling for a typical household of four people with basic comfort needs reasonably met. Regarding heating consumption, the results of the calibrated model are lower than expected savings using the official certificate input data. However, cooling consumption savings were found to be greater than expected.


  • Open Access

    Modelo CFD con validación de campo para el estudio de los alcances de efectividad de técnicas de mitigación de radón por despresurización = CFD model with field validation for the study of the effectiveness of radon mitigation techniques by depressurisation

    by Isabel Sicilia, Borja Frutos, Carmen Alonso, Fernando Martín-Consuegra, Fernando De-Frutos, Ignacio Oteiza, Carlos Sainz, Luis S. Quindós

    La reducción de niveles de gas radón en el interior de edificios supone un desafío debido a las diferentes características de terrenos y sistemas constructivos, especialmente en edificios ya construidos. El artículo presenta los avances en el desarrollo de un modelo de simulación en COMSOL Multiphysics para el estudio de movimientos de gas radón bajo solera. En primer lugar, se estudian los parámetros que afectan a los movimientos del gas, como las características de materiales, terreno, sistemas constructivos y potencia de extracción. Posteriormente, partiendo de una base experimental previa, se calibra un modelo simplificado de forma que se puedan aproximar los resultados del modelo de simulación a los recabados en el modelo real. El presente trabajo se enmarca en el proyecto Radon_Flow (PID2019-109898RB-I00) desarrollado en el Instituto Eduardo Torroja, perteneciente al Consejo Superior de Investigaciones Científicas de España. Reducing radon gas levels inside buildings is a challenge due to the different characteristics of soils and construction systems, especially in existing buildings. The paper presents the progress in the development of a simulation model in COMSOL Multiphysics for the study of radon gas movements under screed. Firstly, the parameters that affect gas movements, such as the characteristics of materials, soil, construction systems and extraction power, are studied. Subsequently, starting from a previous experimental basis, a simplified model is calibrated so that the results of the simulation model can be approximated to those obtained in the real model. This work is part of the Radon_Flow project (PID2019-109898RB-I00) developed at the Eduardo Torroja Institute, belonging to the Spanish National Research Council (CSIC).

  • Open Access

    Analysis of the Optical Response of Opaque Urban Envelope Materials: The Case of Madrid

    by Gloria Pérez, Fernando Martín-Consuegra, Fernando de Frutos, Arturo Martínez, Ignacio Oteiza, Borja Frutos, Carmen Alonso

    The optical response of opaque materials in an urban envelope plays an important role in a city’s energy exchange with the environment as it defines the absorption of radiation and emission of heat. In the present work, the most common surfaces of the finishing materials of pavement and walls in the city of Madrid (Spain) were identified, and their reflectance was measured in situ to determine their solar absorptance and color coordinates. Most of the selected pavement showed a relatively high solar absorptance in the range of 0.87 to 0.60, while in vertical surfaces, the range was 0.85 to 0.29. The variations of the color coordinates obtained for pavement were 27.1, 11.4, and 6.7 for ΔL*, Δa*, and Δb*, respectively. Significantly higher values were obtained in the case of vertical surfaces (47.5, 20.5, and 23.6, respectively). The results were included into a database intended to be the seed for a catalogue of the experimental thermo-optical properties of opaque envelope materials in Madrid. The catalogue will be useful for the analysis of the stimuli generated by the urban environment for citizens and for achieving more reliable results from energy simulation tools in the search for strategies to improve urban comfort and sustainability.


  • Open Access

    Utilización de datos catastrales para la planificación de la rehabilitación energética a escala urbana: aplicación a un barrio ineficiente y vulnerable de Madrid

    by Fernando Martín-Consuegra, Fernando De Frutos, Agustín Hernández-Aja, Ignacio Oteiza, Carmen Alonso, Borja Frutos

    El trabajo que se presenta describe el desarrollo de un método para la estimación de la demanda energética de calefacción de barrios, recopilando los datos catastrales existentes para cada edificio. La automatización del procesamiento de datos permite obtener modelos energéticos de la edificación residencial a la escala urbana con una gran precisión. La metodología propuesta incluye un procedimiento de evaluación para la incorporación de medidas pasivas para la mejora de la eficiencia energética que posibilita la cuantificación de los beneficios obtenidos por las operaciones de rehabilitación de edificios a escala urbana, así como la estimación de los costes necesarios para su ejecución. El método se valida mediante el estudio de caso de un barrio situado en la periferia de Madrid: el Poblado Dirigido de Canillas. Se diagnostica el estado actual del barrio y se evalúa el potencial de mejora resultado de la incorporación de aislamiento térmico en la envolvente opaca de todos los edificios anteriores al año 1979.


  • Open Access

    Indoor Environmental Quality and Consumption Patterns before and during the COVID-19 Lockdown in Twelve Social Dwellings in Madrid, Spain

    by Fernando de Frutos, Teresa Cuerdo-Vilches, Carmen Alonso, Fernando Martín-Consuegra, Borja Frutos, Ignacio Oteiza, Miguel Ángel Navas-Martín

    This article analyses the situation that prevailed in 12 dwellings located on the outskirts of Madrid during Spain’s state of emergency. How did 24/7 occupation affect the quality of indoor air and power consumption patterns? The mixed method used (surveys and instrumental monitoring) pragmatically detected the variation in consumption, comfort and indoor air quality patterns before and during the COVID-19 pandemic. The characteristics initially in place and household predisposition had a conclusive effect on such variations. The starting conditions, including household composition, habits and the way daily activities were performed, differed widely, logically affecting power consumption: 8/12 case studies increase occupancy density by more than 25 percent; 11/12 improve thermal comfort; 10/12 improve air quality but not necessarily translate in a sufficient ventilation practices; air quality was lower in the bedrooms on the whole; only 4/12 case studies use the potential of passive measures; only one household adopted energy savings strategies; 10/12 case studies increase electric power consumption but none of the dwellings was fitted with a renewable power generation system. The conclusion drawn is that, despite starting conditions differing widely, household composition, habits (including performance of daily activities performance) and power consumption also played an active role in the end result. This approach allowed to integrate qualitative and quantitative findings on indoor environmental quality (IEQ), energy use and households’ behavior. The objective data on the energy situation of the case studies not only is useful for the study, but also for potential enrollment in energy rehabilitation programs, such as the European Regional Development Fund (ERDF).


  • Open Access

    Minimal Monitoring of Improvements in Energy Performance after Envelope Renovation in Subsidized Single Family Housing in Madrid

    by Fernando Martín-Consuegra, Fernando de Frutos, Ignacio Oteiza, Carmen Alonso, Borja Frutos

    This study quantified the improvement in energy efficiency following passive renovation of the thermal envelope in highly inefficient residential complexes on the outskirts of the city of Madrid. A case study was conducted of a single-family terrace housing, representative of the smallest size subsidized dwellings built in Spain for workers in the nineteen fifties and sixties. Two units of similar characteristics, one in its original state and the other renovated, were analyzed in detail against their urban setting with an experimental method proposed hereunder for simplified, minimal monitoring. The dwellings were compared on the grounds of indoor environment quality parameters recorded over a period covering both winter and summer months. That information was supplemented with an analysis of the energy consumption metered. The result was a low-cost, reasonably accurate measure of the improvements gained in the renovated unit. The monitoring output data were entered in a theoretical energy efficiency model for the entire neighborhood to obtain an estimate of the potential for energy savings if the entire urban complex were renovated.