Matcha Venu Gopala Rao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Matcha Venu Gopala Rao has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Boddapati Taraka Phani Madhav
Koneru Lakshmaiah Education Foundation
4 shared publications - Devananboyina Venkata Ratnam
Department of ECE, Koneru Lakshmaiah Education Foundation, Guntur, India
4 shared publications - Nadakuditi Durga Indira
Koneru Lakshmaiah Education Foundtion (KLEF)
2 shared publications S. Vathsal
J.B.I.E.T., Hyderabad, A.P., India
2 shared publications- V. G. K. M. Pisipati
Koneru Lakshmaiah Educational Foundation University
2 shared publications A. Kartheek
Department of Electronics and Communication, K L University, Vaddeswaram, Guntur Dist, Andhra Pradesh, India
1 shared publication
Latest Publications
- 30 November 2024
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 44 (4) , 2621-2646
Development of Sparse Time Frequency Distribution Reconstruction Using a Gradient Slime Mould Renyie Entropy Shrinkage Model
- 30 November 2024
- Published by Springer Nature in Circuits, Systems, and Signal Processing
- Vol. 44 (4) , 2621-2646
Development of Sparse Time Frequency Distribution Reconstruction Using a Gradient Slime Mould Renyie Entropy Shrinkage Model
- 6 September 2022
- Published by Springer Nature in International Journal of Intelligent Robotics and Applications
- Vol. 7 (1) , 1-21
Hyperparameter tuning-based triple correlation for spectral analysis-enabled image recovery from moving water surface
- 6 September 2022
- Published by Springer Nature in International Journal of Intelligent Robotics and Applications
- Vol. 7 (1) , 1-21
Hyperparameter tuning-based triple correlation for spectral analysis-enabled image recovery from moving water surface
- Open Access
- 1 August 2022
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 27 (2) , 811-819
Machine learning model to classify modulation techniques using robust convolution neural network
In wireless ccommunications receiver plays a main role to recognize modulation techniques which were used at the transmitter. While transferring information from transmitter to receiver, the receiver must retrieve original information. In order to achieve this goal we introduced a neural network architecture that recognizes the types of modulation techniques. The applications of deep learning can be categorized into classification and detection. The CNN architecture is used to perform feature extraction based on the layers to build a model which classifies the input data. A model that classifies the radio communication signals using deep learning method. The robust c (RCNN) is used to train the modulated signals; the transformations are used to help the neural network which estimate the signal to noise ratio of each signal ranges from -20dB to 18dB with loss and accuracy of 89.57% at SNR 0dB.
- 1 August 2022
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 27 (2) , 811-819
Open AccessMachine learning model to classify modulation techniques using robust convolution neural network
In wireless ccommunications receiver plays a main role to recognize modulation techniques which were used at the transmitter. While transferring information from transmitter to receiver, the receiver must retrieve original information. In order to achieve this goal we introduced a neural network architecture that recognizes the types of modulation techniques. The applications of deep learning can be categorized into classification and detection. The CNN architecture is used to perform feature extraction based on the layers to build a model which classifies the input data. A model that classifies the radio communication signals using deep learning method. The robust c (RCNN) is used to train the modulated signals; the transformations are used to help the neural network which estimate the signal to noise ratio of each signal ranges from -20dB to 18dB with loss and accuracy of 89.57% at SNR 0dB.
- 16 March 2022
- Published by River Publishers in Journal of Mobile Multimedia
The Osteoporosis Disease Diagnosis and Classification Using U-net Deep Learning Process
The purpose of this research has been used to detect osteoporosis disease for Knee radiography. It can improve diagnostic performance over using the scan thermal image mode alone. During 2016 and 2021, researchers gathered CT, MRI, CTA, ultra sound images from individuals who had both skeletal bone density assessment and knee radiology at a local medical clinic for subjective labelling. But following models are most complicate to detect diagnosis of osteoporosis. Therefore, five level convolutional neural networks (CNN) models were used to diagnose osteoporosis from knee radiography. They also looked at ensemble models that included clinical variables in each U-Net. Every net was given an efficiency, accuracy, recall, sensitivity, negative predictive value (npv), F1 measure, and area under curve (AUC) rating. Exclusively knee rays were used to test the U-Net model, but GoogleNet, S-transform, ResNet and FCNN had the lowest accuracy, precision, and specificity. Whenever patient’s data were added, Efficient U-Net had the highest accuracy 99.23%, recall 98.76%, npv 0.93%, F1 score 99.23%, and AUC 99.72% scores among five level prediction methods. The U-Net models correctly identified osteoporosis from Knee radiography, and their performance had improved even more when clinical variables from health records were complex. This u-net based osteoporosis diagnosis is most helpful for future generation for better pre-detections.
- 16 March 2022
- Published by River Publishers in Journal of Mobile Multimedia
The Osteoporosis Disease Diagnosis and Classification Using U-net Deep Learning Process
The purpose of this research has been used to detect osteoporosis disease for Knee radiography. It can improve diagnostic performance over using the scan thermal image mode alone. During 2016 and 2021, researchers gathered CT, MRI, CTA, ultra sound images from individuals who had both skeletal bone density assessment and knee radiology at a local medical clinic for subjective labelling. But following models are most complicate to detect diagnosis of osteoporosis. Therefore, five level convolutional neural networks (CNN) models were used to diagnose osteoporosis from knee radiography. They also looked at ensemble models that included clinical variables in each U-Net. Every net was given an efficiency, accuracy, recall, sensitivity, negative predictive value (npv), F1 measure, and area under curve (AUC) rating. Exclusively knee rays were used to test the U-Net model, but GoogleNet, S-transform, ResNet and FCNN had the lowest accuracy, precision, and specificity. Whenever patient’s data were added, Efficient U-Net had the highest accuracy 99.23%, recall 98.76%, npv 0.93%, F1 score 99.23%, and AUC 99.72% scores among five level prediction methods. The U-Net models correctly identified osteoporosis from Knee radiography, and their performance had improved even more when clinical variables from health records were complex. This u-net based osteoporosis diagnosis is most helpful for future generation for better pre-detections.
- 7 September 2017
- Published by Springer Nature
- p. 41-50
Hyperspectral Unmixing Using Split Augmented Lagrangian Approach
- 7 September 2017
- Published by Springer Nature
- p. 41-50
Hyperspectral Unmixing Using Split Augmented Lagrangian Approach
- Open Access
- 11 May 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (16)
Sub-sampling Techniques for Sampling a Sparse Wideband Signal in Wireless Communications
Background/Objectives: The popularity of Wireless technologies, for applications that urges high bandwidth, increases the demand of Radio frequency (RF) spectrum which leads to scarsity in the spectrum resources. Hence it is required to sense the spectrum of a wideband signal at low sampling rates compared to the Nyquist rate. Methods/Statistical analysis: If the wide band signal is Sparse in frequency domain, then it is used to get over the problem of high sampling rates under the compressive sensing framework. Two different efficient schemes called Modulated Wideband Converter (MWC) and Asynchronous Multi-rate (AMR) are proposed here for wideband spectrum sensing at sub-Nyquist rates. The key features of these methods are also compared with the traditional sub-Nyquist sampling approach called Multi-Coset (MC). Findings: The MC sampling is capable of sampling at different time offsets, but unable to poses channel synchronisation. In MWC sampling, the sparse multiband signal is multiplied by a periodic waveform to shift the spectral components of the band of interest to the origin, then filtered and sampled at low rate. This also makes the computational time to reduce greatly. In AMR sampling, the sparse signal is under sampled at different sampling frequencies to produce sample sets with different aliasing spectra. Later these spectra are compared on a common frequency grid to detect the active bands. This mechanism takes fewer samples there by reduces thee computational cost. The simulation results exhibit these advantages over the traditional sampling techniques for wide band spectrum sensing. Application/Improvements: The trade-off between the selection of MWC for less computational time and MR for low complexity in design makes these sub Nyquist schemes suitable for wide band spectrum sensing in cognitive radio like applications.
- 11 May 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (16)
Open AccessSub-sampling Techniques for Sampling a Sparse Wideband Signal in Wireless Communications
Background/Objectives: The popularity of Wireless technologies, for applications that urges high bandwidth, increases the demand of Radio frequency (RF) spectrum which leads to scarsity in the spectrum resources. Hence it is required to sense the spectrum of a wideband signal at low sampling rates compared to the Nyquist rate. Methods/Statistical analysis: If the wide band signal is Sparse in frequency domain, then it is used to get over the problem of high sampling rates under the compressive sensing framework. Two different efficient schemes called Modulated Wideband Converter (MWC) and Asynchronous Multi-rate (AMR) are proposed here for wideband spectrum sensing at sub-Nyquist rates. The key features of these methods are also compared with the traditional sub-Nyquist sampling approach called Multi-Coset (MC). Findings: The MC sampling is capable of sampling at different time offsets, but unable to poses channel synchronisation. In MWC sampling, the sparse multiband signal is multiplied by a periodic waveform to shift the spectral components of the band of interest to the origin, then filtered and sampled at low rate. This also makes the computational time to reduce greatly. In AMR sampling, the sparse signal is under sampled at different sampling frequencies to produce sample sets with different aliasing spectra. Later these spectra are compared on a common frequency grid to detect the active bands. This mechanism takes fewer samples there by reduces thee computational cost. The simulation results exhibit these advantages over the traditional sampling techniques for wide band spectrum sensing. Application/Improvements: The trade-off between the selection of MWC for less computational time and MR for low complexity in design makes these sub Nyquist schemes suitable for wide band spectrum sensing in cognitive radio like applications.
- 11 December 2015
- Published by Taylor & Francis in Phase Transitions
- Vol. 89 (9) , 902-909
Gradient measurement technique to identify phase transitions in nano-dispersed liquid crystalline compounds
Characterization and phase transitions in pure and 0.5% BaTiO3 nano-dispersed liquid crystalline (LC) N-(p-n-heptyloxybenzylidene)-p-n-nonyloxy aniline, 7O.O9, com-pounds are carried out using a polarizing microscope attached with hot stage and camera. We observed that when any of these images are distorted, different local structures suffer from various degradations in a gradient magnitude. So, we examined the pixel-wise gradient magnitude similarity between the reference and distorted images combined with a novel pooling strategy – the standard deviation of the GMS map – to determine the overall phase transition variations. In this regard, MATLAB software is used for gradient measurement technique to identify the phase transitions and transition temperature of the pure and nano-dispersed LC compounds. The image analysis of this method proposed is in good agreement with the standard methods like polarizing microscope (POM) and differential scanning calorimeter (DSC). 0.5% BaTiO3 nano-dispersed 7O.O9 compound induces cholesteric phase quenching the nematic phase, which the pure compound exhibits.
- 11 December 2015
- Published by Taylor & Francis in Phase Transitions
- Vol. 89 (9) , 902-909
Gradient measurement technique to identify phase transitions in nano-dispersed liquid crystalline compounds
Characterization and phase transitions in pure and 0.5% BaTiO3 nano-dispersed liquid crystalline (LC) N-(p-n-heptyloxybenzylidene)-p-n-nonyloxy aniline, 7O.O9, com-pounds are carried out using a polarizing microscope attached with hot stage and camera. We observed that when any of these images are distorted, different local structures suffer from various degradations in a gradient magnitude. So, we examined the pixel-wise gradient magnitude similarity between the reference and distorted images combined with a novel pooling strategy – the standard deviation of the GMS map – to determine the overall phase transition variations. In this regard, MATLAB software is used for gradient measurement technique to identify the phase transitions and transition temperature of the pure and nano-dispersed LC compounds. The image analysis of this method proposed is in good agreement with the standard methods like polarizing microscope (POM) and differential scanning calorimeter (DSC). 0.5% BaTiO3 nano-dispersed 7O.O9 compound induces cholesteric phase quenching the nematic phase, which the pure compound exhibits.
- Open Access
- 8 May 2015
- Published by Taylor & Francis in Liquid Crystals Today
- Vol. 24 (3) , 81-92
Thermal and phase behaviour studies of hydrogen-bonded compounds (SA:nOBA) using POM, DSC and image-processing techniques
A novel series of hydrogen-bonded liquid crystals are synthesised. The hydrogen bond is formed between non-mesogenic salicylic acid and the mesogenic p-n-alkoxy benzoic acids with n = 4–8, 10–12 and 16. The formation of hydrogen bond is confirmed from infrared studies. The transition temperatures and the phase identification are made with the use of polarising microscope (POM) attached with a hot stage. Further, the heats of transition and enthalpies are obtained by employing the differential scanning calorimeter (DSC). Along with POM and DSC, textural image analysis is done by image-processing techniques using MATLAB software and transition temperatures are identified. The results reveal that the compounds with the chain number n = 7, 8, 10–12 show the manifestation of smectic-B phase by quenching smectic-C phase.
- 8 May 2015
- Published by Taylor & Francis in Liquid Crystals Today
- Vol. 24 (3) , 81-92
Open AccessThermal and phase behaviour studies of hydrogen-bonded compounds (SA:nOBA) using POM, DSC and image-processing techniques
A novel series of hydrogen-bonded liquid crystals are synthesised. The hydrogen bond is formed between non-mesogenic salicylic acid and the mesogenic p-n-alkoxy benzoic acids with n = 4–8, 10–12 and 16. The formation of hydrogen bond is confirmed from infrared studies. The transition temperatures and the phase identification are made with the use of polarising microscope (POM) attached with a hot stage. Further, the heats of transition and enthalpies are obtained by employing the differential scanning calorimeter (DSC). Along with POM and DSC, textural image analysis is done by image-processing techniques using MATLAB software and transition temperatures are identified. The results reveal that the compounds with the chain number n = 7, 8, 10–12 show the manifestation of smectic-B phase by quenching smectic-C phase.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 344-347
Direct Sequence Spread Spectrum transmission and reception using compression techniques
This paper deals Direct Sequence Spread Spectrum (DSSS) transmission and reception using a compression technique. Text and binary signals are transmitted and received through DSSS. Also speech and image are transmitted and received using Huffman Compressive techniques. Discrete cosine transform that compresses speech and image signals through DSSS. The suggested methods are assessed with DSSS signals using Binary Phase-Shift-Keying modulation under Rayleigh channel fading and Additive white Gaussian noise (AWGN). The analysis has performed by comparing Bit Error Rate (BER) for different Signal-to-Noise-Ratio (SNR) levels of AWGN. The results indicate the better performance even for low SNR with good compression ratio.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 344-347
Direct Sequence Spread Spectrum transmission and reception using compression techniques
This paper deals Direct Sequence Spread Spectrum (DSSS) transmission and reception using a compression technique. Text and binary signals are transmitted and received through DSSS. Also speech and image are transmitted and received using Huffman Compressive techniques. Discrete cosine transform that compresses speech and image signals through DSSS. The suggested methods are assessed with DSSS signals using Binary Phase-Shift-Keying modulation under Rayleigh channel fading and Additive white Gaussian noise (AWGN). The analysis has performed by comparing Bit Error Rate (BER) for different Signal-to-Noise-Ratio (SNR) levels of AWGN. The results indicate the better performance even for low SNR with good compression ratio.
- Open Access
- 26 February 2015
- Published by Defence Scientific Information and Documentation Centre in Defence Science Journal
- Vol. 65 (1) , 5-11
Faster Acquisition Technique for Software-defined GPS Receivers
Faster Acquisition Technique for Software-defined GPS Receivers
- 26 February 2015
- Published by Defence Scientific Information and Documentation Centre in Defence Science Journal
- Vol. 65 (1) , 5-11
Open AccessFaster Acquisition Technique for Software-defined GPS Receivers
Faster Acquisition Technique for Software-defined GPS Receivers