Abigail R. Manning
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abigail R. Manning has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Andrew J. Solomon
Department of Neurological Sciences Larner College of Medicine at the University of Vermont Burlington Vermont USA
2 shared publicationsPrasanna Parvathaneni
Translational Neuroradiology Section, National Institute of Neurological Disorders and Stroke National Institutes of Health Bethesda Maryland USA
2 shared publicationsRussell T. Shinohara
Penn Statistics in Imaging and Visualization Center, Department of Biostatistics, Epidemiology, and Informatics, Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
2 shared publicationsA. Bar-Or
Department of Neurology (A.B.-O., R.D.S., M.K.S.), University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania
1 shared publicationA.J. Solomon
Department of Neurological Sciences (A.J.S.), Larner College of Medicine at the University of Vermont, Burlington, Vermont
1 shared publicationB. Renner
Department of Neurology (E.G., B.R., N.L.S., O.A.-L., P.S.), Cedars-Sinai Medical Center, Los Angeles, California
1 shared publication
Latest Publications
- Open Access
- 27 September 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (3) , 620-626
Multicenter Automated Central Vein Sign Detection Performs as Well as Manual Assessment for the Diagnosis of Multiple Sclerosis
BACKGROUND AND PURPOSE: The central vein sign (CVS) is a proposed diagnostic imaging biomarker for multiple sclerosis (MS). The proportion of white matter lesions exhibiting the CVS (CVS+) is higher in patients with MS compared with its radiologic mimics. Evaluation for CVS+ lesions in prior studies has been performed by manual rating, an approach that is time-consuming and has variable interrater reliability. Accurate automated methods would facilitate efficient assessment for CVS. The objective of this study was to compare the performance of an automated CVS detection method with manual rating for the diagnosis of MS. MATERIALS AND METHODS: 3T MRI was acquired in 86 participants undergoing evaluation for MS in a 9-site multicenter study. Participants presented with either typical or atypical clinical syndromes for MS. An automated CVS detection method was employed and compared with manual rating, including total CVS+ proportion and a simplified counting method in which experts visually identified up to 6 CVS+ lesions by using FLAIR* contrast (a voxelwise product of T2 FLAIR and postcontrast T2*-EPI). RESULTS: Automated CVS processing was completed in 79 of 86 participants (91%), of whom 28 (35%) fulfilled the 2017 McDonald criteria at the time of imaging. The area under the receiver operating characteristic curve (AUC) for discrimination between participants with and without MS for the automated CVS approach was 0.78 (95% CI: [0.67,0.88]). This was not significantly different from simplified manual counting methods (select6*) (0.80 [0.69,0.91]) or manual assessment of total CVS+ proportion (0.89 [0.82,0.96]). In a sensitivity analysis excluding 11 participants whose MRI exhibited motion artifact, the AUC for the automated method was 0.81 [0.70,0.91], which was not statistically different from that for select6* (0.79 [0.68,0.92]) or manual assessment of total CVS+ proportion (0.89 [0.81,0.97]). CONCLUSIONS: Automated CVS assessment was comparable to manual CVS scoring for differentiating patients with MS from those with other diagnoses. Large, prospective, multicenter studies utilizing automated methods and enrolling the breadth of disorders referred for suspicion of MS are needed to determine optimal approaches for clinical implementation of an automated CVS detection method.
- 27 September 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (3) , 620-626
Open AccessMulticenter Automated Central Vein Sign Detection Performs as Well as Manual Assessment for the Diagnosis of Multiple Sclerosis
BACKGROUND AND PURPOSE: The central vein sign (CVS) is a proposed diagnostic imaging biomarker for multiple sclerosis (MS). The proportion of white matter lesions exhibiting the CVS (CVS+) is higher in patients with MS compared with its radiologic mimics. Evaluation for CVS+ lesions in prior studies has been performed by manual rating, an approach that is time-consuming and has variable interrater reliability. Accurate automated methods would facilitate efficient assessment for CVS. The objective of this study was to compare the performance of an automated CVS detection method with manual rating for the diagnosis of MS. MATERIALS AND METHODS: 3T MRI was acquired in 86 participants undergoing evaluation for MS in a 9-site multicenter study. Participants presented with either typical or atypical clinical syndromes for MS. An automated CVS detection method was employed and compared with manual rating, including total CVS+ proportion and a simplified counting method in which experts visually identified up to 6 CVS+ lesions by using FLAIR* contrast (a voxelwise product of T2 FLAIR and postcontrast T2*-EPI). RESULTS: Automated CVS processing was completed in 79 of 86 participants (91%), of whom 28 (35%) fulfilled the 2017 McDonald criteria at the time of imaging. The area under the receiver operating characteristic curve (AUC) for discrimination between participants with and without MS for the automated CVS approach was 0.78 (95% CI: [0.67,0.88]). This was not significantly different from simplified manual counting methods (select6*) (0.80 [0.69,0.91]) or manual assessment of total CVS+ proportion (0.89 [0.82,0.96]). In a sensitivity analysis excluding 11 participants whose MRI exhibited motion artifact, the AUC for the automated method was 0.81 [0.70,0.91], which was not statistically different from that for select6* (0.79 [0.68,0.92]) or manual assessment of total CVS+ proportion (0.89 [0.81,0.97]). CONCLUSIONS: Automated CVS assessment was comparable to manual CVS scoring for differentiating patients with MS from those with other diagnoses. Large, prospective, multicenter studies utilizing automated methods and enrolling the breadth of disorders referred for suspicion of MS are needed to determine optimal approaches for clinical implementation of an automated CVS detection method.
- 30 January 2023
- Published by Wiley in Journal of Neuroimaging
- Vol. 33 (3) , 434-445
T1/T2 ratio from 3T MRI improves multiple sclerosis cortical lesion contrast
Background and Purpose: Cortical demyelinated lesions are prevalent in multiple sclerosis (MS), associated with disability, and have recently been incorporated into MS diagnostic criteria. Presently, advanced and ultrahigh‐field MRIs—not routinely available in clinical practice—are the most sensitive methods for detection of cortical lesions. Approaches utilizing MRI sequences obtainable in routine clinical practice remain an unmet need. We plan to assess the sensitivity of the ratio of T1‐weighted and T2‐weighted (T1/T2) signal intensity for focal cortical lesions in comparison to other high‐field imaging methods.Methods: 3‐Tesla and 7‐Tesla MRI collected from 10 adults with MS were included in the study. T1/T2 images were calculated by dividing 3T T1‐weighted (T1w) images by 3T T2‐weighted (T2w) fluid‐attenuated inversion recovery images for each participant. A total of 614 cortical lesions were identified using 7T T2*w and T1w images and corresponding voxels were assessed on registered 3T images. Signal intensities were compared across 3T imaging sequences, including T1/T2, T1w, T2w, and inversion recovery susceptibility‐weighted imaging with enhanced T2 weighting (IR‐SWIET) images.Results: T1/T2 images demonstrated a larger contrast between median lesional and nonlesional cortical signal intensity (median ratio = 1.29, range: 1.19‐1.38) when compared to T1w (1.01, 0.97‐1.10, p < .002), T2w (1.17, 1.07‐1.26, p < .002), and IR‐SWIET (1.21, 1.01‐1.29, p < .03).Conclusion: T1/T2 images are sensitive to cortical lesions. Approaches incorporating T1/T2 could improve the accessibility of cortical lesion detection in research settings and clinical practice.
- 30 January 2023
- Published by Wiley in Journal of Neuroimaging
- Vol. 33 (3) , 434-445
T1/T2 ratio from 3T MRI improves multiple sclerosis cortical lesion contrast
Background and Purpose: Cortical demyelinated lesions are prevalent in multiple sclerosis (MS), associated with disability, and have recently been incorporated into MS diagnostic criteria. Presently, advanced and ultrahigh‐field MRIs—not routinely available in clinical practice—are the most sensitive methods for detection of cortical lesions. Approaches utilizing MRI sequences obtainable in routine clinical practice remain an unmet need. We plan to assess the sensitivity of the ratio of T1‐weighted and T2‐weighted (T1/T2) signal intensity for focal cortical lesions in comparison to other high‐field imaging methods.Methods: 3‐Tesla and 7‐Tesla MRI collected from 10 adults with MS were included in the study. T1/T2 images were calculated by dividing 3T T1‐weighted (T1w) images by 3T T2‐weighted (T2w) fluid‐attenuated inversion recovery images for each participant. A total of 614 cortical lesions were identified using 7T T2*w and T1w images and corresponding voxels were assessed on registered 3T images. Signal intensities were compared across 3T imaging sequences, including T1/T2, T1w, T2w, and inversion recovery susceptibility‐weighted imaging with enhanced T2 weighting (IR‐SWIET) images.Results: T1/T2 images demonstrated a larger contrast between median lesional and nonlesional cortical signal intensity (median ratio = 1.29, range: 1.19‐1.38) when compared to T1w (1.01, 0.97‐1.10, p < .002), T2w (1.17, 1.07‐1.26, p < .002), and IR‐SWIET (1.21, 1.01‐1.29, p < .03).Conclusion: T1/T2 images are sensitive to cortical lesions. Approaches incorporating T1/T2 could improve the accessibility of cortical lesion detection in research settings and clinical practice.
- Open Access
T 1 /T 2 Ratio Imaging Improves Cortical Lesion Contrast in Multiple Sclerosis on 3T MRI
Background: Cortical demyelinated lesions are prevalent in multiple sclerosis (MS) and associated with disability; their presence on MRI has recently been incorporated into MS diagnostic criteria. Presently, advanced and ultra-high-field MRI — not routinely available in clinical practice — are the most sensitive methods for detection of cortical lesions, and approaches utilizing MRI sequences obtainable in routine clinical practice remain an unmet need. Objective: To assess the sensitivity of the ratio of T 1 -weighted and T 2 -weighted (T 1 /T 2 ) signal intensity for focal cortical lesions in comparison to other established, sensitive, advanced and high-field imaging methods. Methods: 3-tesla (3T) and 7-tesla (7T) MRI collected from 10 adults with MS participating in a natural history study at the National Institutes of Health were included in the study. T 1 /T 2 images were calculated by dividing 3T T 1 w images by 3T T 2 w fluid-attenuated inversion recovery (FLAIR) images for each participant. Cortical lesions were identified using 7T T 2 *w and T 1 w images and corresponding voxels were assessed on registered 3T images. For each participant, ratios derived from the median signal intensity of nonlesional tissue in the cortical region of the lesion and the median lesional voxel intensity were computed. These values were compared across 3T imaging sequences, including the calculated T 1 /T 2 image, as well as T 1 w, T 2 w, and Inversion Recovery Susceptibility Weighted Imaging with Enhanced T 2 weighting (IR-SWIET) images. Results: 614 cortical lesions were identified on 7T images. 3T T 1 /T 2 images demonstrated a larger contrast between median nonlesional cortical signal intensity and median cortical lesion signal intensity (median ratio = 1.29, range 1.19 – 1.38) when compared to T 1 w (1.01, 0.97 – 1.10, p2 w (1.17, 1.07 – 1.26, p1 /T 2 images are sensitive to cortical lesions. Approaches incorporating T 1 /T 2 could improve the accessibility of cortical lesion detection in research settings and clinical practice.
Open AccessT 1 /T 2 Ratio Imaging Improves Cortical Lesion Contrast in Multiple Sclerosis on 3T MRI
Background: Cortical demyelinated lesions are prevalent in multiple sclerosis (MS) and associated with disability; their presence on MRI has recently been incorporated into MS diagnostic criteria. Presently, advanced and ultra-high-field MRI — not routinely available in clinical practice — are the most sensitive methods for detection of cortical lesions, and approaches utilizing MRI sequences obtainable in routine clinical practice remain an unmet need. Objective: To assess the sensitivity of the ratio of T 1 -weighted and T 2 -weighted (T 1 /T 2 ) signal intensity for focal cortical lesions in comparison to other established, sensitive, advanced and high-field imaging methods. Methods: 3-tesla (3T) and 7-tesla (7T) MRI collected from 10 adults with MS participating in a natural history study at the National Institutes of Health were included in the study. T 1 /T 2 images were calculated by dividing 3T T 1 w images by 3T T 2 w fluid-attenuated inversion recovery (FLAIR) images for each participant. Cortical lesions were identified using 7T T 2 *w and T 1 w images and corresponding voxels were assessed on registered 3T images. For each participant, ratios derived from the median signal intensity of nonlesional tissue in the cortical region of the lesion and the median lesional voxel intensity were computed. These values were compared across 3T imaging sequences, including the calculated T 1 /T 2 image, as well as T 1 w, T 2 w, and Inversion Recovery Susceptibility Weighted Imaging with Enhanced T 2 weighting (IR-SWIET) images. Results: 614 cortical lesions were identified on 7T images. 3T T 1 /T 2 images demonstrated a larger contrast between median nonlesional cortical signal intensity and median cortical lesion signal intensity (median ratio = 1.29, range 1.19 – 1.38) when compared to T 1 w (1.01, 0.97 – 1.10, p2 w (1.17, 1.07 – 1.26, p1 /T 2 images are sensitive to cortical lesions. Approaches incorporating T 1 /T 2 could improve the accessibility of cortical lesion detection in research settings and clinical practice.