Susumu Kono
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Susumu Kono has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
David Mukai
5 shared publicationsTaku Obara
5 shared publications- Priyana Rajbhandari3 shared publications
- Trevor Zhiqing Yeow
Institute of Integrated Research, Institute of Science Tokyo, Kanagawa, Japan
3 shared publications - Clarissa Jasinda2 shared publications
Hidekazu Watanabe
Structural Research Group Building Research Institute Tsukuba Japan
2 shared publications
Latest Publications
- Open Access
- 2 February 2026
- Published by Elsevier in Engineering Structures
- Vol. 353
Structural performance of circular hollow precast high-strength concrete-filled steel tube piles under cyclic flexural and varying high axial loads
- 2 February 2026
- Published by Elsevier in Engineering Structures
- Vol. 353
Open AccessStructural performance of circular hollow precast high-strength concrete-filled steel tube piles under cyclic flexural and varying high axial loads
- Open Access
- 4 September 2025
- Published by Elsevier in Engineering Structures
- Vol. 343
Experimental investigation and development of design equation for circular hollow precast high-strength concrete-filled steel tube piles under uniaxial compressive loading
- 4 September 2025
- Published by Elsevier in Engineering Structures
- Vol. 343
Open AccessExperimental investigation and development of design equation for circular hollow precast high-strength concrete-filled steel tube piles under uniaxial compressive loading
- Open Access
- 13 January 2025
- Published by Elsevier in Engineering Structures
- Vol. 327
Strain-based performance evaluation of planar flexural reinforced concrete walls
- 13 January 2025
- Published by Elsevier in Engineering Structures
- Vol. 327
Open AccessStrain-based performance evaluation of planar flexural reinforced concrete walls
- Open Access
- 26 July 2024
- Published by Elsevier in Resilient Cities and Structures
- Vol. 3 (4) , 1-20
Quantitative crack evaluation in slender reinforced concrete walls with rectangular section
- 26 July 2024
- Published by Elsevier in Resilient Cities and Structures
- Vol. 3 (4) , 1-20
Open AccessQuantitative crack evaluation in slender reinforced concrete walls with rectangular section
- Open Access
- 25 June 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 95
Predictive equations for limit states drift ratio of non-structural reinforced concrete walls
- 25 June 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 95
Open AccessPredictive equations for limit states drift ratio of non-structural reinforced concrete walls
- Open Access
- 28 August 2023
- Published by Elsevier in Engineering Structures
- Vol. 294
Axial behavior of square steel-tubed ultra-high-strength reinforced concrete columns
- 28 August 2023
- Published by Elsevier in Engineering Structures
- Vol. 294
Open AccessAxial behavior of square steel-tubed ultra-high-strength reinforced concrete columns
- Open Access
- 1 October 2022
- Published by Architectural Institute of Japan in Journal of Structural and Construction Engineering (Transactions of AIJ)
- Vol. 87 (800) , 966-975
NUMERICAL ANALYSIS OF PRECAST REINFORCED HIGH-STRENGTH CONCRETE PILES FOCUSING ON ULTIMATE CONDITION UNDER HIGH AXIAL COMPRESSION FORCE AND BENDING MOMENT
In the precast reinforced high-strength spun concrete piles, (PRC piles), a numerical model on ultimate flexural condition has not been established when PRC piles have high axial force. The numerical analysis using a multi-spring model was conducted to reproduce the experimental results of six PRC pile specimens with axial force ratio ranging 0~0.313 in compression. The backbone curves of lateral load−drift angle relations were well simulated with this numerical model until ultimate condition. Furthermore, the scale effect was also investigated to see the moment capacity and post peak behavior from parametric study.
- 1 October 2022
- Published by Architectural Institute of Japan in Journal of Structural and Construction Engineering (Transactions of AIJ)
- Vol. 87 (800) , 966-975
Open AccessNUMERICAL ANALYSIS OF PRECAST REINFORCED HIGH-STRENGTH CONCRETE PILES FOCUSING ON ULTIMATE CONDITION UNDER HIGH AXIAL COMPRESSION FORCE AND BENDING MOMENT
In the precast reinforced high-strength spun concrete piles, (PRC piles), a numerical model on ultimate flexural condition has not been established when PRC piles have high axial force. The numerical analysis using a multi-spring model was conducted to reproduce the experimental results of six PRC pile specimens with axial force ratio ranging 0~0.313 in compression. The backbone curves of lateral load−drift angle relations were well simulated with this numerical model until ultimate condition. Furthermore, the scale effect was also investigated to see the moment capacity and post peak behavior from parametric study.
- 1 August 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (8) , 04022106
Evaluation of the Seismic Performance of Unbonded Post-Tensioned Precast Concrete Walls with Internal and External Dampers. II: Design Criteria and Numerical Research
This paper presents an analytical procedure to assess the monotonic (envelope) force-deformation response (capacity curve) of unbonded post-tensioning precast concrete (UPT) walls with internal and external replaceable dampers. This procedure, which can also be used to design UPT walls, was compared and validated against experimental evidence. A close agreement (strength discrepancies of 2% on average) was found between the response predictions and experimental results. This agreement was maintained until peak strength was achieved. Moreover, fiber-based models were implemented to further study the cyclic behavior of UPT walls designed according to the proposed analytical procedure. The numerical models were accurate in representing the global cyclic behavior of UPT walls in terms of strength, displacement capacity, and energy dissipation; nonetheless, these models showed some discrepancies in capturing the residual drifts of some UPT walls with internal dampers. A parametric analysis was also conducted to explore the influence of some design parameters on the deformation capacity and energy dissipation of UPT walls. It was found that the ratio of damper reinforcement is critical for the energy dissipation and self-centering capacity of UPT walls, so ratios of 0.10 to 0.25 should be provided to follow the limit states indicated in this paper. Based on the results, the analytical procedure and limit states presented in this paper are considered suitable for UPT walls with external replaceable dampers under total axial load ratios equal or lower than 0.125.
- 1 August 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (8) , 04022106
Evaluation of the Seismic Performance of Unbonded Post-Tensioned Precast Concrete Walls with Internal and External Dampers. II: Design Criteria and Numerical Research
This paper presents an analytical procedure to assess the monotonic (envelope) force-deformation response (capacity curve) of unbonded post-tensioning precast concrete (UPT) walls with internal and external replaceable dampers. This procedure, which can also be used to design UPT walls, was compared and validated against experimental evidence. A close agreement (strength discrepancies of 2% on average) was found between the response predictions and experimental results. This agreement was maintained until peak strength was achieved. Moreover, fiber-based models were implemented to further study the cyclic behavior of UPT walls designed according to the proposed analytical procedure. The numerical models were accurate in representing the global cyclic behavior of UPT walls in terms of strength, displacement capacity, and energy dissipation; nonetheless, these models showed some discrepancies in capturing the residual drifts of some UPT walls with internal dampers. A parametric analysis was also conducted to explore the influence of some design parameters on the deformation capacity and energy dissipation of UPT walls. It was found that the ratio of damper reinforcement is critical for the energy dissipation and self-centering capacity of UPT walls, so ratios of 0.10 to 0.25 should be provided to follow the limit states indicated in this paper. Based on the results, the analytical procedure and limit states presented in this paper are considered suitable for UPT walls with external replaceable dampers under total axial load ratios equal or lower than 0.125.
- 25 April 2022
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 51 (9) , 2091-2112
Shear performance evaluation of PHC piles under different levels of axial load ratio
Precast prestressed high‐strength spun concrete (PHC) piles are one of the common types of piles used in Japan due to its high bearing capacity. These piles have been utilized as an industrial standard since the 1970s as part of earthquake‐resilient foundation systems. The focus of this research is to examine the shear performance of PHC piles subjected to large earthquake loads. Three hollow‐section PHC pile specimens were tested under constant compressive or tensile axial load along with quasi‐static antisymmetric lateral load. An investigation using finite element analysis was carried out to reproduce the damage that occurred during the experiment. Comparison between experimental and analytical results were presented in terms of global and local behaviors of the piles. The finite element models were able to simulate axial splitting cracks that occurred for specimens under axial compression load. In addition, a parametric study was conducted to observe the influence of axial load ratio and shear span to diameter ratio on the shear capacity and failure mode of PHC piles. The study results along with the results from a PHC pile database are compared to the shear design equation proposed in the guidelines for PHC piles from the Architectural Institute of Japan (AIJ).
- 25 April 2022
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 51 (9) , 2091-2112
Shear performance evaluation of PHC piles under different levels of axial load ratio
Precast prestressed high‐strength spun concrete (PHC) piles are one of the common types of piles used in Japan due to its high bearing capacity. These piles have been utilized as an industrial standard since the 1970s as part of earthquake‐resilient foundation systems. The focus of this research is to examine the shear performance of PHC piles subjected to large earthquake loads. Three hollow‐section PHC pile specimens were tested under constant compressive or tensile axial load along with quasi‐static antisymmetric lateral load. An investigation using finite element analysis was carried out to reproduce the damage that occurred during the experiment. Comparison between experimental and analytical results were presented in terms of global and local behaviors of the piles. The finite element models were able to simulate axial splitting cracks that occurred for specimens under axial compression load. In addition, a parametric study was conducted to observe the influence of axial load ratio and shear span to diameter ratio on the shear capacity and failure mode of PHC piles. The study results along with the results from a PHC pile database are compared to the shear design equation proposed in the guidelines for PHC piles from the Architectural Institute of Japan (AIJ).
- 24 March 2022
- Published by Elsevier in Thin-Walled Structures
- Vol. 174
Flexural performance of cast-in-place concrete-filled steel tube piles under varying axial load
- 24 March 2022
- Published by Elsevier in Thin-Walled Structures
- Vol. 174
Flexural performance of cast-in-place concrete-filled steel tube piles under varying axial load