Reza Karimi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Reza Karimi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Sanderson
Department of Physics and Astronomy University of Waterloo 200 University Avenue West N2L 3G1 Waterloo Ontario Canada
3 shared publications - Alexander H. Xu
Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
2 shared publications - Alexandru Nica
National Institute for Materials Science (NIMS), University of Tsukuba, Tsukuba 305-0044, Ibaraki, Japan
2 shared publications - Christopher Lloyd
RETEGO Bio Labs LLC, West Bountiful, UT 84087, USA
2 shared publications - Inna Novodchuk
Waterloo Institute for Nanotechnology (WIN), University of Waterloo, Waterloo, ON N2L 3G1, Canada
2 shared publications - Liena Zaidan
Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
2 shared publications
Latest Publications
- Open Access
Rapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli
Escherichia coli (E. coli) was among the first organisms to have its complete genome published (Genome Sequence of E. coli 1997 Science). It is used as a model system in microbiology research. E. coli can cause life-threatening illnesses, particularly in children and the elderly. Possible contamination by the bacteria also results in product recalls, which, alongside the potential danger posed to individuals, can have significant financial consequences. We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field-effect transistor (FET) biosensor with B/N co-coped reduced graphene oxide (rGO) gel (BN-rGO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 min. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10–108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-rGO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.
Open AccessRapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli
Escherichia coli (E. coli) was among the first organisms to have its complete genome published (Genome Sequence of E. coli 1997 Science). It is used as a model system in microbiology research. E. coli can cause life-threatening illnesses, particularly in children and the elderly. Possible contamination by the bacteria also results in product recalls, which, alongside the potential danger posed to individuals, can have significant financial consequences. We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field-effect transistor (FET) biosensor with B/N co-coped reduced graphene oxide (rGO) gel (BN-rGO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 min. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10–108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-rGO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.
- Open Access
- 24 June 2024
- Published by MDPI AG in Preprints.org
Rapid, Selective, and Ultra-Sensitive Electronic Field Effect Detection of Escherichia coli
We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field effect transistor (FET) biosensor with B/N co-coped graphene oxide (GO) gel (BN-GO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 minutes. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10– 108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-GO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.
- 24 June 2024
- Published by MDPI AG in Preprints.org
Open AccessRapid, Selective, and Ultra-Sensitive Electronic Field Effect Detection of Escherichia coli
We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field effect transistor (FET) biosensor with B/N co-coped graphene oxide (GO) gel (BN-GO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 minutes. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10– 108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-GO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.
- Open Access
- 7 September 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 635 (10) , 102017
Formation of hydrocarbon species and carbon clusters through femtosecond laser ablation of cryogenic solidified methane
Femtosecond laser ablation of cryogenically solidified CH4 using a peak intensity 8×1014 W/cm2 at 800 nm has been studied using time of flight mass spectroscopy. Spectra show the presence of hydrocarbon species with molecular mass higher than the original target molecule.
- 7 September 2015
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 635 (10) , 102017
Open AccessFormation of hydrocarbon species and carbon clusters through femtosecond laser ablation of cryogenic solidified methane
Femtosecond laser ablation of cryogenically solidified CH4 using a peak intensity 8×1014 W/cm2 at 800 nm has been studied using time of flight mass spectroscopy. Spectra show the presence of hydrocarbon species with molecular mass higher than the original target molecule.