RKReza Karimi

Reza Karimi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Reza Karimi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Rapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli

    by Liena Zaidan, Inna Novodchuk, Alexander H.Xu, Alexandru Nica, Saeed Takaloo, Christopher Lloyd, Reza Karimi, Joe Sanderson, Michal Bajcsy, Mustafa Yavuz

    Escherichia coli (E. coli) was among the first organisms to have its complete genome published (Genome Sequence of E. coli 1997 Science). It is used as a model system in microbiology research. E. coli can cause life-threatening illnesses, particularly in children and the elderly. Possible contamination by the bacteria also results in product recalls, which, alongside the potential danger posed to individuals, can have significant financial consequences. We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field-effect transistor (FET) biosensor with B/N co-coped reduced graphene oxide (rGO) gel (BN-rGO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 min. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10–108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-rGO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.


  • Open Access

    Rapid, Selective, and Ultra-Sensitive Electronic Field Effect Detection of Escherichia coli

    by Liena Zaidan, Inna Novodchuk, Alexandru Nica, Alexander H.Xu, Christopher Lloyd, Reza Karimi, Joe Sanderson, Michal Bajcsy, Mustafa Yavuz

    We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field effect transistor (FET) biosensor with B/N co-coped graphene oxide (GO) gel (BN-GO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 minutes. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10– 108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-GO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.


  • Open Access

    Formation of hydrocarbon species and carbon clusters through femtosecond laser ablation of cryogenic solidified methane

    by Reza Karimi, Asif Zaidi, Yiming Cai, Mojtaba Hajialamdari, Joseph Sanderson, Walter Duley

    Femtosecond laser ablation of cryogenically solidified CH4 using a peak intensity 8×1014 W/cm2 at 800 nm has been studied using time of flight mass spectroscopy. Spectra show the presence of hydrocarbon species with molecular mass higher than the original target molecule.