Sarranya Banerjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sarranya Banerjee has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Vasant Matsagar
Indian Institute of Technology Delhi
8 shared publications - Aparna (Dey) Ghosh
Department of Civil Engineering, Indian Institute of Engineering Science and Technology (IIEST), Shibpur, India
2 shared publications Akanshu Sharma
Purdue Univ
1 shared publicationAparna (Dey) Ghosh
1 shared publicationKunal Dahiya
Central Public Works Department (CPWD)
1 shared publication- Marcus Maeder
Technical University of Munich
1 shared publication
Latest Publications
- 1 January 2027
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 153 (1) , 04026212
Buckling Behavior of Fiber-Reinforced Elastomeric Isolators under Elevated Temperatures
During the course of their design life, base isolators may be subjected to elevated temperatures for a variety of reasons, including fire hazards. In such scenarios of elevated temperatures, the vertical load-carrying capacity of base isolators could deteriorate. Therefore, assessment of the stability of fiber-reinforced elastomeric isolators (FREIs) under the vertical loads from the superstructure while under elevated temperatures is important. In this study, the buckling behavior of FREIs is investigated under ambient and elevated temperatures. Available closed-form expressions to predict the buckling load of FREIs at ambient temperatures are extended for applications under elevated temperatures. Under elevated temperatures, the buckling load is derived by considering the thermal expansion of the FREIs and the material degradation of the elastomers with the rise in temperature. Further, nonlinear finite-element analyses are conducted to numerically evaluate the buckling behavior of a wide range of FREIs with various inherent properties. Modified Riks analysis is utilized to estimate the nonlinear buckling behavior of the FREIs. Transient heat transfer analysis within the FREIs is conducted to observe the buckling loads of the FREIs after various time instances, and the steady-state uniform elevated temperature in the FREI is found to be the worst-case condition under the considered thermal boundary conditions. Herein, only the thermal scenarios of uniform elevated temperatures at all the faces of a single FREI are explored. It is observed that the closed-form expressions for buckling load under elevated temperatures could effectively predict the buckling loads of the FREIs, providing slightly conservative values for most cases. Interestingly, the results show that the FREIs with low aspect ratios (such as 1.20) demonstrate the maximum reduction in their vertical load-carrying capacity with the rise in temperature.
- 1 January 2027
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 153 (1) , 04026212
Buckling Behavior of Fiber-Reinforced Elastomeric Isolators under Elevated Temperatures
During the course of their design life, base isolators may be subjected to elevated temperatures for a variety of reasons, including fire hazards. In such scenarios of elevated temperatures, the vertical load-carrying capacity of base isolators could deteriorate. Therefore, assessment of the stability of fiber-reinforced elastomeric isolators (FREIs) under the vertical loads from the superstructure while under elevated temperatures is important. In this study, the buckling behavior of FREIs is investigated under ambient and elevated temperatures. Available closed-form expressions to predict the buckling load of FREIs at ambient temperatures are extended for applications under elevated temperatures. Under elevated temperatures, the buckling load is derived by considering the thermal expansion of the FREIs and the material degradation of the elastomers with the rise in temperature. Further, nonlinear finite-element analyses are conducted to numerically evaluate the buckling behavior of a wide range of FREIs with various inherent properties. Modified Riks analysis is utilized to estimate the nonlinear buckling behavior of the FREIs. Transient heat transfer analysis within the FREIs is conducted to observe the buckling loads of the FREIs after various time instances, and the steady-state uniform elevated temperature in the FREI is found to be the worst-case condition under the considered thermal boundary conditions. Herein, only the thermal scenarios of uniform elevated temperatures at all the faces of a single FREI are explored. It is observed that the closed-form expressions for buckling load under elevated temperatures could effectively predict the buckling loads of the FREIs, providing slightly conservative values for most cases. Interestingly, the results show that the FREIs with low aspect ratios (such as 1.20) demonstrate the maximum reduction in their vertical load-carrying capacity with the rise in temperature.
- Open Access
- 9 July 2026
- Published by Springer Nature
- p. 698-710
Service-Life Performance of Base-Isolated Hospital Building Under Multiple Hazards
Base isolation is an attractive technique for protection of structures against earthquakes. Especially, lifeline structures such as hospitals need to remain operational during and after natural disasters like earthquakes or cyclones. However, various environmental factors gradually degrade the performance of the base-isolated buildings in the form of deterioration of the material properties utilized in the base isolation as well as in the primary structure itself. Therefore, the present study aims to investigate the service-life performance of a base-isolated hospital building situated in New Delhi, India under multiple hazards. A detailed numerical study is conducted wherein the lead rubber bearing (LRB)-isolated hospital building is subjected to nonconcurrent earthquake and wind excitations. The effect of chloride-induced degradation of the structural elements and the oxidation-based degradation of the rubber in the LRBs is investigated over the service-life of the building. Interestingly, due to the addition of the LRBs, the hospital building could attain operational performance under earthquakes even with reduced structural member sizes, which in turn diminishes the carbon footprint of the entire project. Therefore, this study further compares the multi-hazard service-life performance of a regular base-isolated structure against a base-isolated structure with reduced carbon footprint.
- 9 July 2026
- Published by Springer Nature
- p. 698-710
Open AccessService-Life Performance of Base-Isolated Hospital Building Under Multiple Hazards
Base isolation is an attractive technique for protection of structures against earthquakes. Especially, lifeline structures such as hospitals need to remain operational during and after natural disasters like earthquakes or cyclones. However, various environmental factors gradually degrade the performance of the base-isolated buildings in the form of deterioration of the material properties utilized in the base isolation as well as in the primary structure itself. Therefore, the present study aims to investigate the service-life performance of a base-isolated hospital building situated in New Delhi, India under multiple hazards. A detailed numerical study is conducted wherein the lead rubber bearing (LRB)-isolated hospital building is subjected to nonconcurrent earthquake and wind excitations. The effect of chloride-induced degradation of the structural elements and the oxidation-based degradation of the rubber in the LRBs is investigated over the service-life of the building. Interestingly, due to the addition of the LRBs, the hospital building could attain operational performance under earthquakes even with reduced structural member sizes, which in turn diminishes the carbon footprint of the entire project. Therefore, this study further compares the multi-hazard service-life performance of a regular base-isolated structure against a base-isolated structure with reduced carbon footprint.
- 1 June 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 31 (6) , 04026023
Multihazard Dynamic Response Control of Long-Span Cable-Stayed Bridges Using Spatially Distributed Tuned Mass Dampers
Long-span cable-stayed bridges present significant engineering challenges due to their susceptibility to dynamic excitations across multiple frequency ranges. This study develops an innovat...
- 1 June 2026
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 31 (6) , 04026023
Multihazard Dynamic Response Control of Long-Span Cable-Stayed Bridges Using Spatially Distributed Tuned Mass Dampers
Long-span cable-stayed bridges present significant engineering challenges due to their susceptibility to dynamic excitations across multiple frequency ranges. This study develops an innovat...
- 29 September 2024
- Published by Springer Nature
- p. 410-427
Probabilistic Performance Assessment of Base-Isolated Hospital Building Under Earthquake Excitations
- 29 September 2024
- Published by Springer Nature
- p. 410-427
Probabilistic Performance Assessment of Base-Isolated Hospital Building Under Earthquake Excitations
- Open Access
Hybrid Vibration Control of Hospital Buildings against Earthquake Excitations Using Unbonded Fiber-Reinforced Elastomeric Isolator and Tuned Mass Damper
Lifeline structures such as hospital buildings need to be specifically designed such that they experience reduced vibrations when subjected to earthquake excitations because it will be difficult to vacate hospital buildings under the event of any earthquake. Therefore, to ensure operational condition under earthquake excitations in an existing hospital building, the present study utilizes flexible unbonded fiber-reinforced elastomeric isolators (UFREIs) for its seismic isolation. The UFREI-based isolation system is designed to restrict the structural acceleration within the tolerable limits for the building inhabitants even during earthquake hazards. However, the use of such flexible isolators results in excessively large bearing displacements, which either may not be practical and/or pose several serviceability issues. Therefore, tuned mass damper (TMD) is attached to the base floor of the UFREI-isolated hospital building to reduce the large isolator displacements. Properties of the hybrid vibration control system are designed according to the site-specific scenario in New Delhi, India. Further, nonlinear time-history analyses of the UFREI-isolated hospital building with the TMD are carried out, and responses are compared with its uncontrolled response. Results show that the peak bearing displacement response of the UFREI-isolated hospital building is reduced by 9% to 27%, due to the addition of the TMD. Importantly, the required design displacement of the UFREI-based isolation system is decreased by 27%, without compromising the effectiveness of base isolation. In fact, the performance of the hybrid vibration control system is superior to the base isolation system alone.
Open AccessHybrid Vibration Control of Hospital Buildings against Earthquake Excitations Using Unbonded Fiber-Reinforced Elastomeric Isolator and Tuned Mass Damper
Lifeline structures such as hospital buildings need to be specifically designed such that they experience reduced vibrations when subjected to earthquake excitations because it will be difficult to vacate hospital buildings under the event of any earthquake. Therefore, to ensure operational condition under earthquake excitations in an existing hospital building, the present study utilizes flexible unbonded fiber-reinforced elastomeric isolators (UFREIs) for its seismic isolation. The UFREI-based isolation system is designed to restrict the structural acceleration within the tolerable limits for the building inhabitants even during earthquake hazards. However, the use of such flexible isolators results in excessively large bearing displacements, which either may not be practical and/or pose several serviceability issues. Therefore, tuned mass damper (TMD) is attached to the base floor of the UFREI-isolated hospital building to reduce the large isolator displacements. Properties of the hybrid vibration control system are designed according to the site-specific scenario in New Delhi, India. Further, nonlinear time-history analyses of the UFREI-isolated hospital building with the TMD are carried out, and responses are compared with its uncontrolled response. Results show that the peak bearing displacement response of the UFREI-isolated hospital building is reduced by 9% to 27%, due to the addition of the TMD. Importantly, the required design displacement of the UFREI-based isolation system is decreased by 27%, without compromising the effectiveness of base isolation. In fact, the performance of the hybrid vibration control system is superior to the base isolation system alone.
- 18 March 2022
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 29 (7)
Optimum design of nonlinear tuned mass damper for dynamic response control under earthquake and wind excitations
- 18 March 2022
- Published by Wiley in Structural Control and Health Monitoring
- Vol. 29 (7)
Optimum design of nonlinear tuned mass damper for dynamic response control under earthquake and wind excitations
- 17 September 2020
- Published by Taylor & Francis in Journal of Structural Integrity and Maintenance
- Vol. 5 (4) , 211-222
Optimal design of nonlinear TMD with Bingham-type damping for base-excited structures
This paper presents an optimal design procedure for a nonlinear TMD with Bingham-type damping that can lead to a more economic and realistic design of the damper. The optimization problem is solved in the Genetic Algorithm (GA) framework. Considering small nonlinearities, the nonlinear TMD design using GA is validated through standard equivalent linearization method. The efficacy of the TMD designs is presented through a numerical simulation study on four different single-degree-of-freedom structure-TMD systems subjected to recorded earthquake ground motions. Results indicate that the optimally designed nonlinear TMD with Bingham-type damping can effectively reduce the size of the TMD damping element at the cost of a very slight degradation in control performance as compared to the linear TMD. The improved performance of the nonlinear TMD with Bingham-type damping over the linear TMD that develops post-design nonlinearities is also shown. Further, a robust design procedure of the nonlinear TMD using GA is presented that can cater to perturbations in the natural frequency of the primary structure. Thus, the optimal design procedure using GA for the nonlinear TMD offers several advantages as compared to the statistical linearization approach.
- 17 September 2020
- Published by Taylor & Francis in Journal of Structural Integrity and Maintenance
- Vol. 5 (4) , 211-222
Optimal design of nonlinear TMD with Bingham-type damping for base-excited structures
This paper presents an optimal design procedure for a nonlinear TMD with Bingham-type damping that can lead to a more economic and realistic design of the damper. The optimization problem is solved in the Genetic Algorithm (GA) framework. Considering small nonlinearities, the nonlinear TMD design using GA is validated through standard equivalent linearization method. The efficacy of the TMD designs is presented through a numerical simulation study on four different single-degree-of-freedom structure-TMD systems subjected to recorded earthquake ground motions. Results indicate that the optimally designed nonlinear TMD with Bingham-type damping can effectively reduce the size of the TMD damping element at the cost of a very slight degradation in control performance as compared to the linear TMD. The improved performance of the nonlinear TMD with Bingham-type damping over the linear TMD that develops post-design nonlinearities is also shown. Further, a robust design procedure of the nonlinear TMD using GA is presented that can cater to perturbations in the natural frequency of the primary structure. Thus, the optimal design procedure using GA for the nonlinear TMD offers several advantages as compared to the statistical linearization approach.
- Open Access
- 1 September 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 936 (1)
Optimal Design of Tuned Mass Damper for Base-Excited Structures
The tuned mass damper (TMD) is a well-established vibration control device that has been implemented in several structures worldwide. The performance of passive TMD is greatly dependent on its design parameters. A key issue for the design of the optimal TMD is the identification of the parameters of the structure to which the TMD is to be attached. Here, it is important also to consider the perturbations that may arise in the structural frequency due to different practical issues. The present work focusses on this and aims to obtain the optimum TMD parameters in a Genetic Algorithm (GA) framework. The results of the proposed optimal strategy, in terms of optimal tuning ratio and optimal damping ratio, for a given value of the mass ratio, are compared with some of the existing optimal solutions for linear TMD under base excitation. The effectiveness of all these optimally designed TMDs in reducing the structural response is further demonstrated when the structure-TMD system is subjected to recorded earthquake ground motions. It is seen that in the tuned condition, the control performance obtained by the different designs of the TMD are similar to each other, although having some minor differences in the values of the optimum parameters. Also, the effectiveness of the different TMD designs in the detuned condition is investigated, in which the present design technique is found to be the most effective.
- 1 September 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 936 (1)
Open AccessOptimal Design of Tuned Mass Damper for Base-Excited Structures
The tuned mass damper (TMD) is a well-established vibration control device that has been implemented in several structures worldwide. The performance of passive TMD is greatly dependent on its design parameters. A key issue for the design of the optimal TMD is the identification of the parameters of the structure to which the TMD is to be attached. Here, it is important also to consider the perturbations that may arise in the structural frequency due to different practical issues. The present work focusses on this and aims to obtain the optimum TMD parameters in a Genetic Algorithm (GA) framework. The results of the proposed optimal strategy, in terms of optimal tuning ratio and optimal damping ratio, for a given value of the mass ratio, are compared with some of the existing optimal solutions for linear TMD under base excitation. The effectiveness of all these optimally designed TMDs in reducing the structural response is further demonstrated when the structure-TMD system is subjected to recorded earthquake ground motions. It is seen that in the tuned condition, the control performance obtained by the different designs of the TMD are similar to each other, although having some minor differences in the values of the optimum parameters. Also, the effectiveness of the different TMD designs in the detuned condition is investigated, in which the present design technique is found to be the most effective.