Wengang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wengang Liu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Hiu Lam Chow
Department of Biomedical Engineering, City University of Hong Kong
3 shared publications- Ting-Hsuan Chen
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region, 999077, China
3 shared publications Cho Fan Chung
Department of Biomedical Engineering, City University of Hong Kong
2 shared publicationsHogi Hartanto
Department of Biomedical Engineering, City University of Hong Kong
2 shared publicationsHoi Kwan Kwong
Department of Biomedical Engineering, City University of Hong Kong
2 shared publications- Jianpeng Wu
Department of Biomedical Engineering, City University of Hong Kong
2 shared publications
Latest Publications
- Open Access
- 22 August 2024
- Published by eLife Sciences Publications, Ltd in eLife preprints
- Vol. 12
Cell chirality reversal through tilted balance between polymerization of radial fibers and clockwise-swirling of transverse arcs
Cell chirality is an intrinsic property shown as biased cell rotation or orientation. Although the right-handed double helix of actin is known important, how a single form of molecular handedness manifests diverse forms of cell chirality remains unclear. Here, we found that the cell nucleus rotated with a clockwise (CW) bias in a small projected area, but this rotation reversed to an anticlockwise (ACW) bias as cell spreading increased. Actin analysis suggested that radial fiber polymerization accounts for the ACW bias. Alterations in transverse arc components (myosin II, mDia2, and tropomyosin 4) revealed that the CW bias is driven by the retrograde flow, originating from the tethered gliding motion of myosin II in the contractile structure of transverse arcs. Thus, an imbalance between radial fibers and transverse arcs results in cell chirality reversal. The findings elucidate the mechanisms underlying cell chirality reversal, providing a new perspective on mechanobiology.
- 22 August 2024
- Published by eLife Sciences Publications, Ltd in eLife preprints
- Vol. 12
Open AccessCell chirality reversal through tilted balance between polymerization of radial fibers and clockwise-swirling of transverse arcs
Cell chirality is an intrinsic property shown as biased cell rotation or orientation. Although the right-handed double helix of actin is known important, how a single form of molecular handedness manifests diverse forms of cell chirality remains unclear. Here, we found that the cell nucleus rotated with a clockwise (CW) bias in a small projected area, but this rotation reversed to an anticlockwise (ACW) bias as cell spreading increased. Actin analysis suggested that radial fiber polymerization accounts for the ACW bias. Alterations in transverse arc components (myosin II, mDia2, and tropomyosin 4) revealed that the CW bias is driven by the retrograde flow, originating from the tethered gliding motion of myosin II in the contractile structure of transverse arcs. Thus, an imbalance between radial fibers and transverse arcs results in cell chirality reversal. The findings elucidate the mechanisms underlying cell chirality reversal, providing a new perspective on mechanobiology.
- Open Access
- 9 July 2024
- Published by Springer Nature in Research Square
Cell chirality reversal through tilted balance betweenpolymerization of radial bers and clockwise-swirling of transverse arcs
Cell chirality is an intrinsic property shown as biased cell rotation or orientation. While the righthanded helix of actin is known essential, it is intriguing of how single form of molecular handedness can be manifested into diverse and even mirrored forms of cell chirality. Here, we found that cell nucleus rotates with clockwise (CW) bias with smaller projected area but reverses to anticlockwise (ACW) bias when cell spreading increases. Actin analysis suggests that polymerization of righthanded radial fibers accounts for the ACW bias, while the CW bias is driven by the retrograde flow of CW-swirling transverse arc, which originates from tethered myosin II that simultaneously connect radial fibers and transverse arc. Thus, by tilting the balance between these two classes of actin fibers via cell spreading area or the main factors of actin, i.e., myosin II, α-actinin-1, Tpm4, and mDia2, the single form of actin helix can be unfolded into cell chirality with opposite bias. This finding suggests a mechanistic insight of cell chirality reversal, providing new perspective in mechanobiology and tissue formation.
- 9 July 2024
- Published by Springer Nature in Research Square
Open AccessCell chirality reversal through tilted balance betweenpolymerization of radial bers and clockwise-swirling of transverse arcs
Cell chirality is an intrinsic property shown as biased cell rotation or orientation. While the righthanded helix of actin is known essential, it is intriguing of how single form of molecular handedness can be manifested into diverse and even mirrored forms of cell chirality. Here, we found that cell nucleus rotates with clockwise (CW) bias with smaller projected area but reverses to anticlockwise (ACW) bias when cell spreading increases. Actin analysis suggests that polymerization of righthanded radial fibers accounts for the ACW bias, while the CW bias is driven by the retrograde flow of CW-swirling transverse arc, which originates from tethered myosin II that simultaneously connect radial fibers and transverse arc. Thus, by tilting the balance between these two classes of actin fibers via cell spreading area or the main factors of actin, i.e., myosin II, α-actinin-1, Tpm4, and mDia2, the single form of actin helix can be unfolded into cell chirality with opposite bias. This finding suggests a mechanistic insight of cell chirality reversal, providing new perspective in mechanobiology and tissue formation.
- Open Access
- 3 June 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (22) , eabn6064
Microfluidic particle dam for direct visualization of SARS-CoV-2 antibody levels in COVID-19 vaccinees
Various COVID-19 vaccines are currently deployed, but their immunization varies and decays with time. Antibody level is a potent correlate to immune protection, but its quantitation relies on intensive laboratory techniques. Here, we report a decentralized, instrument-free microfluidic device that directly visualizes SARS-CoV-2 antibody levels. Magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) can bind to SARS-CoV-2 antibodies simultaneously. In a microfluidic chip, this binding reduces the incidence of free PMPs escaping from magnetic separation and shortens PMP accumulation length at a particle dam. This visual quantitative result enables use in either sensitive mode [limit of detection (LOD): 13.3 ng/ml; sample-to-answer time: 70 min] or rapid mode (LOD: 57.8 ng/ml; sample-to-answer time: 20 min) and closely agrees with the gold standard enzyme-linked immunosorbent assay. Trials on 91 vaccinees revealed higher antibody levels in mRNA vaccinees than in inactivated vaccinees and their decay in 45 days, demonstrating the need for point-of-care devices to monitor immune protection.
- 3 June 2022
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 8 (22) , eabn6064
Open AccessMicrofluidic particle dam for direct visualization of SARS-CoV-2 antibody levels in COVID-19 vaccinees
Various COVID-19 vaccines are currently deployed, but their immunization varies and decays with time. Antibody level is a potent correlate to immune protection, but its quantitation relies on intensive laboratory techniques. Here, we report a decentralized, instrument-free microfluidic device that directly visualizes SARS-CoV-2 antibody levels. Magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) can bind to SARS-CoV-2 antibodies simultaneously. In a microfluidic chip, this binding reduces the incidence of free PMPs escaping from magnetic separation and shortens PMP accumulation length at a particle dam. This visual quantitative result enables use in either sensitive mode [limit of detection (LOD): 13.3 ng/ml; sample-to-answer time: 70 min] or rapid mode (LOD: 57.8 ng/ml; sample-to-answer time: 20 min) and closely agrees with the gold standard enzyme-linked immunosorbent assay. Trials on 91 vaccinees revealed higher antibody levels in mRNA vaccinees than in inactivated vaccinees and their decay in 45 days, demonstrating the need for point-of-care devices to monitor immune protection.