NSNicole E. P. Stark

Nicole E. P. Stark

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nicole E. P. Stark has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Steve Rowson

    Department of Biomedical Engineering, Virginia Tech, Blacksburg, USA

    7 shared publications
  • Brianna A. Reilly

    School of Neuroscience, College of Science, Virginia Tech, Blacksburg, VA, USA

    2 shared publications
  • Brianna Reilly

    Institute for Critical Technology and Applied Science, Virginia Tech, Blacksburg, USA

    2 shared publications
  • Damon Kuehl

    Emergency Medicine, Carilion Roanoke Memorial Hospital, Roanoke, USA

    2 shared publications
  • Damon R. Kuehl

    Department of Emergency Medicine, Virginia Tech Carilion, Roanoke, VA, USA; Emergency Medicine, Virginia Tech Carilion School of Medicine, Blacksburg, VA, USA

    2 shared publications
  • Ethan S. Henley

    Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, VA, USA; School of Neuroscience, College of Science, Virginia Tech, Blacksburg, VA, USA

    2 shared publications

Latest Publications

  • Open Access

    Relating Real-World Falls to Laboratory Test Conditions

    by Susanna M. Gagliardi, Nicole E.-P. Stark, Michael L. Madigan, Steve Rowson

    Purpose: Falls account for over half of fatal work-related traumatic brain injuries, yet current safety helmet standards do not test energy levels representative of falls. Additionally, little is known about how fall impact mitigating mechanisms (FIMMs), such as fall arrest movements and/or object contact, and reduce head impact velocity. This study used a multi-step analytical approach to estimate head impact speeds from various fall heights while factoring in energy reduction due to FIMMs. Methods: Laboratory drop tests established peak linear accelerations (PLAs) and head injury criterion (HIC) values across a range of impact velocities. These PLA/HIC values were then input into skull fracture risk curves to establish the risk of skull fracture at various head impact speeds. At matched levels of risk, a risk curve relating real-world fall height to skull fracture risk was used to estimate the fall heights associated with different head impact velocities. A worst-case head impact velocity representing a direct, head-first fall without FIMMs was calculated using basic energy assumptions from the specified fall height. FIMMs were quantified as the percent reduction in the worst-case velocity from a given fall height to the laboratory head impact velocity. Results: FIMMs may reduce head impact velocity by 44.5–64.4% compared to a head-first impact without FIMMs. Conclusion: To evaluate safety helmets under realistic impact conditions, lab-based head impact velocities should be reduced by 44.5–64.4% from the worst-case velocity to account for a population-level estimate energy reduction associated with FIMMs.

  • Open Access

    Fall detection in extreme class imbalance: a cascade architecture for real-world deployment

    by Ethan Henley, Nicole E.-P. Stark, Brianna Reilly, Katherine D. Mayes, Damon Kuehl, Steve Rowson

    Falls among older adults result in over 3 million emergency department visits and 32,000 deaths annually in the United States, with medical costs exceeding $50 billion. Automated fall detection systems face a fundamental challenge: extreme class imbalance in continuous monitoring, where fall events constitute less than 2% of footage, causing high false-positive rates and alarm fatigue. We propose a cascade architecture that decomposes fall detection into two sequential stages with complementary optimization objectives. Stage 1 employs a lightweight 3D convolutional neural network trained via curriculum learning with adaptive focal loss to deliberately maximize recall on the minority class. Stage 2 applies a feature-based arbiter that analyzes CNN internal representations to validate candidates, reducing false positives while preserving sensitivity. We validated our approach on 190 videos with simulated falls (LE2I dataset) and 300 spontaneous falls from elderly residents in long-term care facilities (Robinovitch dataset). Our cascade architecture achieved 82.4% recall with 32.2% precision, representing a 38% relative precision improvement over single-stage CNN baselines (88.5% recall, 23.3% precision). The 40.5% false positive reduction substantially improves clinical viability while maintaining sensitivity above 80%, providing a foundation for real-world deployment in care settings facing severe data constraints.

  • Open Access

    Distributions of plantar loads are altered when walking in anxiety-inducing virtual settings but not under cognitive demand

    by Kelly Poretti, Nicole E. P. Stark, Francesca E. Wade, Peter C. Fino, Tiphanie E. Raffegeau

    Additional cognitive load and fall-related anxiety alter balance and locomotor control, independent of motor demands. Exposing participants to virtual elevation increases perceived cost of falling, and individuals alter the distribution of medial and lateral plantar loading to maintain balance and avoid a lateral postural threat (in virtual reality). Here, we extend this prior work to examine anterior and posterior loading in response to cognitive demand and virtual elevation to induce anxiety. We predicted that the distribution of plantar loads between the medial and lateral, and anterior and posterior compartments of in-shoe load sensors would indicate within-step changes to locomotor balance control across walking conditions. Healthy participants ( N = 16) were pseudorandomized into single- or dual-task trial blocks first. While wearing a head-mounted virtual-reality display and in-shoe load sensors, participants walked at self-selected pace overground on a 40 cm wide by 5.2 m long walkway at virtual high and low elevation during single and dual-tasks. For dual-tasking, participants walked and talked extemporaneously about a randomly selected topic. All participants wore their own footwear. The distribution of medial and lateral and anterior and posterior loads was computed across normalized stance. Statistical parametric mapping determined significant differences in plantar load distribution by walking condition. Fall-related anxiety led to a more medial load distribution during 11% to 75% of stance and more posterior distribution during heel strike from 0% to 4% of stance. There were no load distribution changes due to the extemporaneous speech dual-task. Walking at high virtual elevation, not during a dual-task, led to a medial shift in plantar load during stance, and more posterior loading during initial contact. Plantar load distributions were primarily adjusted within-steps to avoid lateral postural threats when step width was constrained by a narrow path.


  • Open Access

    Head Impacts in Long-Term Care Falls Are Common but Often Underrecognized: A Video-Based Analysis of Injury and Transport

    by Brianna Reilly, Taylor Yu, Richard Dykstra, Steve Rowson, Damon Kuehl, Katherine D. Mayes, Nicole E.-P. Stark

    Falls are the leading cause of injury-related morbidity and mortality among older adults, particularly in long-term care (LTC) facilities. Although head impacts are common during falls, the relationship between impact occurrence, injury characteristics, and hospital transport remains inadequately defined. The objectives of this study were to (1) compare falls with and without head impact, (2) quantify unrecognized head impacts and their contexts, (3) examine factors associated with head injury occurrence, and (4) identify predictors of hospital transport following head impacts. This secondary analysis used an open-source video dataset from two LTC facilities. Three raters reviewed each of the 300 fall videos to determine the presence of head impact. Transport and injury data were extracted directly from the open-source, observational video dataset. Falls were characterized using the Fall Video Analysis Questionnaire. Generalized estimating equations evaluated predictors of head injury, and logistic regression modeled predictors of hospital transport. Head impacts were common yet often underrecognized when relying on reported or visible injuries. Many falls without documented head injury demonstrated clear head impact on video, indicating that visible injury is a poor proxy for impact. Hospital transport following head impact was uncommon and was primarily associated with visible injuries rather than patient characteristics or fall history. Most head impacts, including those without obvious injury, did not result in transport. These findings suggest that reliance on external injury may lead to underrecognition and potential under-triage of head trauma. Improved detection strategies beyond visible injury are needed to better identify clinically significant head impacts.

  • Open Access

    Evaluating Polo Helmet Performance Across Different Impact Test Systems

    by Nicole E.-P. Stark, Mark T. Begonia, Steve Rowson

    Purpose: This study evaluated head impact response between different helmet impact test systems by comparing the performance of ten polo helmets. Methods: Helmets were evaluated using three test systems: a twin-wire guided drop tower, an oblique drop tower, and an impact pendulum. Impact tests were conducted at matched locations (front boss, side, rear boss) and speeds (3.46, 5.46 m/s). We employed a linear mixed model with helmet model as a random effect and calculated the least square mean differences between systems for peak linear acceleration (PLA), peak rotational acceleration (PRA), peak rotational velocity (PRV), and concussion risk. Correlations between systems by impact speed were explored, using linear models of each system as a function of the others, and calculated Spearman rank correlation coefficients between test systems for each dependent variable. Results: Our results found distinct differences in PRA and concussion risk between the oblique and the pendulum impact systems due to the driving force. The acceleration range across helmet models was substantial, and responses differed between test systems at matched impact conditions. However, there were similarities between test systems in the rank order of helmet models. Head acceleration differences between helmets translated to larger differences in concussion risk between helmet models. Conclusion: These trends provide a framework for comparing the headform’s response across varying loading conditions. When selecting a test system to evaluate helmets for a specific sport, it is essential to consider the relevant impact conditions and loading patterns to ensure that laboratory tests accurately represent real-world scenarios.


  • Kinematic Insights Into Older Adult Fall-Related Head Impacts: Boundary Conditions and Injury Risk

    by Nicole E.-P. Stark, Ethan S. Henley, Brianna A. Reilly, Damon R. Kuehl, Steve Rowson


  • Open Access

    Uncalibrated Single-Camera View Video Tracking of Head Impact Speeds Using Model-Based Image Matching

    by Nicole E.-P. Stark, Ethan S. Henley, Brianna A. Reilly, John S. Nowinski, Gabrielle M. Ferro, Michael L. Madigan, Damon R. Kuehl, Steve Rowson

    Purpose: This study evaluates the accuracy of a model-based image matching (MBIM) approach with model calibration for tracking head impact speeds in uncalibrated spaces from single-camera views. Methods: Two validation datasets were used. The first included 36 videos of guided NOCSAE headform drops at varying camera positions (heights, distances, camera angles) where a speed gate measured vertical impact speed. The second dataset had eight videos of participants performing ladder falls with marked helmets, captured using a 12-camera motion capture system to track head impact speeds. Each video was tracked frame-by-frame, matching a 3D NOCSAE headform model to the head using MBIM software. Accuracy was assessed by comparing captured to MBIM-tracked speeds by the mean difference and Root Mean Square Error (RMSE). A linear model assessed the influence of camera position. Results: For ideal camera views (90 degrees, height 1 or 1.4 m), MBIM-tracked vertical speeds were 0.04 ± 0.15 m/s faster than the true speed (RMSE 0.15 m/s; 2.3 ± 6.2% error). Across all 36 NOCSAE videos, MBIM-tracked vertical speeds were 0.03 ± 0.19 m/s faster (RMSE 0.19 m/s; 1.8 ± 6.9 % error). In participant videos, MBIM-tracked resultant speeds were 0.01 ± 0.33 m/s slower (RMES 0.31; 0.7 ± 9.5% error) compared to motion capture. Conclusion: MBIM with model calibration can analyze head impact kinematics from single-camera footage without environment calibration, achieving reasonable accuracy compared to other systems. Analyzing head impact kinematics from uncalibrated single-camera footage presents significant opportunities for assessing previously untraceable videos.


  • Open Access

    The Influence of Headform Friction and Inertial Properties on Oblique Impact Helmet Testing

    by Nicole E.-P. Stark, Mark Begonia, Luca Viano, Steven Rowson

    Helmet-testing headforms replicate the human head impact response, allowing the assessment of helmet protection and injury risk. However, the industry uses three different headforms with varying inertial and friction properties making study comparisons difficult because these headforms have different inertial and friction properties that may affect their impact response. This study aimed to quantify the influence of headform coefficient of friction (COF) and inertial properties on oblique impact response. The static COF of each headform condition (EN960, Hybrid III, NOCSAE, Hybrid III with a skull cap, NOCSAE with a skull cap) was measured against the helmet lining material used in a KASK prototype helmet. Each headform condition was tested with the same helmet model at two speeds (4.8 & 7.3 m/s) and two primary orientations (y-axis and x-axis rotation) with 5 repetitions, totaling 100 tests. The influence of impact location, inertial properties, and friction on linear and rotational impact kinematics was investigated using a MANOVA, and type II sums of squares were used to determine how much variance in dependent variables friction and inertia accounted for. Our results show significant differences in impact response between headforms, with rotational head kinematics being more sensitive to differences in inertial rather than frictional properties. However, at high-speed impacts, linear head kinematics are more affected by changes in frictional properties rather than inertial properties. Helmet testing protocols should consider differences between headforms’ inertial and frictional properties during interpretation. These results provide a framework for cross-comparative analysis between studies that use different headforms and headform modifiers.


  • Open Access

    Human Head and Helmet Interface Friction Coefficients with Biological Sex and Hair Property Comparisons

    by Nicole E.-P. Stark, Charlotte Clark, Steve Rowson

    Dummy headforms used for impact testing have changed little over the years, and frictional characteristics are thought not to represent the human head accurately. The frictional interface between the helmet and head is an essential factor affecting impact response. However, few studies have evaluated the coefficient of friction (COF) between the human head and helmet surface. This study’s objectives were to quantify the human head’s static and dynamic COF and evaluate the effect of biological sex and hair properties. Seventy-four participants slid their heads along a piece of helmet foam backed by a fixed load cell at varying normal force levels. As normal force increased, static and dynamic human head COF decreased following power–law curves. At 80 N, the static COF is 0.32 (95% CI 0.30–0.34), and the dynamic friction coefficient is 0.27 (95% CI 0.26–0.28). Biological sex and hair properties were determined not to affect human head COF. The COFs between the head and helmet surface should be used to develop more biofidelic head impact testing methods, define boundary conditions for computer simulations, and aid decision-making for helmet designs.


  • Patients with unilateral ankle arthritis have decreased discrete and time‐series limb symmetry compared to healthy controls

    by Nicole E.‐P. Stark, Jill Streamer, Robin Queen

    Patients with ankle arthritis (AA) have side‐to‐side limb differences at the ankle and in spatiotemporal measures; however, the degree of symmetry between limbs has not been compared to a healthy population. The purpose of this study was to determine differences in limb symmetry during walking for discrete and time‐series measures when comparing patients with unilateral AA to healthy participants. Thirty‐seven AA and 37 healthy participants were age, gender, and body mass index matched. Three‐dimensional gait mechanics and ground reaction force (GRF) were captured during four to seven walking trails. GRF and hip and ankle mechanics were extracted bilaterally for each trial. The Normalized Symmetry Index and Statistical Parameter Mapping were used to assess discrete and time‐series symmetry, respectively. Discrete symmetry was analyzed using linear mixed‐effect models to determine significant differences between groups (α = 0.05). Compared to healthy participants, patients with AA had decreased weight acceptance (p = 0.017) and propulsive (p < 0.001) GRF, ankle plantarflexion (p = 0.021), ankle dorsiflexion (p = 0.010), and ankle plantarflexion moment (p < 0.001) symmetry. Significant regions of difference were found between limbs and groups throughout the stance phase for the vertical GRF force (p < 0.001), the ankle angle during push‐off (p = 0.047), the plantarflexion moment (p < 0.001), and the hip extension angle (p = 0.034) and moment (p = 0.010). Patients with AA have decreased symmetry in the vertical GRF and at the ankle and hip during the weight acceptance and propulsive portions of the stance phase. Therefore, clinicians should try a non improving symmetry focusing on changing hip and ankle mechanics during the weight acceptance and propulsive phases of gait.