Roberto Simonini
Roberto Simonini has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Pietro Andrea Bonaffini
Department of Radiology, ASST Papa Giovanni XXIII, Bergamo, Italy
3 shared publications - Sandro Sironi
School of Medicine, University of Milano-Bicocca, 20126 Milan, Italy
3 shared publications - Davide Ippolito
School of Medicine and Surgery, University of Milan-Bicocca, Monza, Italy
2 shared publications - Marco Porta
Radiology Unit, Zucchi Clinical Institutes Spa, Monza, Italy
2 shared publications - Paolo Marra
Department of Radiology, ASST Papa Giovanni XXIII, Bergamo, Italy
2 shared publications - Alberto Aliprandi
Department of Radiology, Istituti Clinici Zucchi, Monza, Italy
1 shared publication
Latest Publications
- Open Access
- 28 January 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (3) , 483
Can We Apply Snyder’s Arthroscopic Classification to Ultrasound for Evaluating Rotator Cuff Tears? A Comparative Study with MR Arthrography
We aimed to demonstrate the applicability of Snyder’s arthroscopic classification of rotator cuff tears (RCT) in shoulder ultrasound (US) and to compare it with MR arthrography (MRA). Forty-six patients (34 males; mean age:34 ± 14 years) underwent shoulder US and MRA. Two radiologists (R1 = 25 years of experience; R2 = 2 years of experience) assigned A1–4, B1–4, or C1–4 values depending on the extent of RCT in both US and MRA. Inter-reader intra-modality and intra-reader inter-modality agreement were calculated using Cohen’s kappa coefficient. US sensitivity and specificity of both readers were calculated using MRA as the gold standard. Patients were divided into intact cuff vs. tears, mild (A1/B1) vs. moderate (A2–3/B2–3) tears, mild-moderate (A2/B2) vs. high-moderate (A3/B3) cuff tears, moderate (A2–3/B2–3) vs. advanced (A4/B4) and full-thickness (C) tears. The highest agreement values in inter-reader US evaluation were observed for mild-moderate vs. high-moderate RCT (K = 0.745), in inter-reader MRA evaluation for mild vs. moderate RCT (K = 0.821), in R1 inter-modality (US-MRA) for mild-moderate vs. high-moderate and moderate vs. advanced/full-thickness RCT (K = 1.000), in R2 inter-modality (US-MRA) for moderate vs. advanced/full-thickness RCT (K = 1.000). US sensitivity ranged from 88.89%(R1)–84.62%(R2) to 100% (both readers), while specificity from 77.78%(R1)–90.00%(R2) to 100% (both readers). Snyder’s classification can be used in US to ensure the correct detection and characterization of RCT.
- 28 January 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (3) , 483
Open AccessCan We Apply Snyder’s Arthroscopic Classification to Ultrasound for Evaluating Rotator Cuff Tears? A Comparative Study with MR Arthrography
We aimed to demonstrate the applicability of Snyder’s arthroscopic classification of rotator cuff tears (RCT) in shoulder ultrasound (US) and to compare it with MR arthrography (MRA). Forty-six patients (34 males; mean age:34 ± 14 years) underwent shoulder US and MRA. Two radiologists (R1 = 25 years of experience; R2 = 2 years of experience) assigned A1–4, B1–4, or C1–4 values depending on the extent of RCT in both US and MRA. Inter-reader intra-modality and intra-reader inter-modality agreement were calculated using Cohen’s kappa coefficient. US sensitivity and specificity of both readers were calculated using MRA as the gold standard. Patients were divided into intact cuff vs. tears, mild (A1/B1) vs. moderate (A2–3/B2–3) tears, mild-moderate (A2/B2) vs. high-moderate (A3/B3) cuff tears, moderate (A2–3/B2–3) vs. advanced (A4/B4) and full-thickness (C) tears. The highest agreement values in inter-reader US evaluation were observed for mild-moderate vs. high-moderate RCT (K = 0.745), in inter-reader MRA evaluation for mild vs. moderate RCT (K = 0.821), in R1 inter-modality (US-MRA) for mild-moderate vs. high-moderate and moderate vs. advanced/full-thickness RCT (K = 1.000), in R2 inter-modality (US-MRA) for moderate vs. advanced/full-thickness RCT (K = 1.000). US sensitivity ranged from 88.89%(R1)–84.62%(R2) to 100% (both readers), while specificity from 77.78%(R1)–90.00%(R2) to 100% (both readers). Snyder’s classification can be used in US to ensure the correct detection and characterization of RCT.
- Open Access
- 26 October 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (21) , 6304
Radiomics in PI-RADS 3 Multiparametric MRI for Prostate Cancer Identification: Literature Models Re-Implementation and Proposal of a Clinical–Radiological Model
PI-RADS 3 prostate lesions clinical management is still debated, with high variability among different centers. Identifying clinically significant tumors among PI-RADS 3 is crucial. Radiomics applied to multiparametric MR (mpMR) seems promising. Nevertheless, reproducibility assessment by external validation is required. We retrospectively included all patients with at least one PI-RADS 3 lesion (PI-RADS v2.1) detected on a 3T prostate MRI scan at our Institution (June 2016–March 2021). An MRI-targeted biopsy was used as ground truth. We assessed reproducible mpMRI radiomic features found in the literature. Then, we proposed a new model combining PSA density and two radiomic features (texture regularity (T2) and size zone heterogeneity (ADC)). All models were trained/assessed through 100-repetitions 5-fold cross-validation. Eighty patients were included (26 with GS ≥ 7). In total, 9/20 T2 features (Hector’s model) and 1 T2 feature (Jin’s model) significantly correlated to biopsy on our dataset. PSA density alone predicted clinically significant tumors (sensitivity: 66%; specificity: 71%). Our model obtained a sensitivity of 80% and a specificity of 76%. Standard-compliant works with detailed methodologies achieve comparable radiomic feature sets. Therefore, efforts to facilitate reproducibility are needed, while complex models and imaging protocols seem not, since our model combining PSA density and two radiomic features from routinely performed sequences appeared to differentiate clinically significant cancers.
- 26 October 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (21) , 6304
Open AccessRadiomics in PI-RADS 3 Multiparametric MRI for Prostate Cancer Identification: Literature Models Re-Implementation and Proposal of a Clinical–Radiological Model
PI-RADS 3 prostate lesions clinical management is still debated, with high variability among different centers. Identifying clinically significant tumors among PI-RADS 3 is crucial. Radiomics applied to multiparametric MR (mpMR) seems promising. Nevertheless, reproducibility assessment by external validation is required. We retrospectively included all patients with at least one PI-RADS 3 lesion (PI-RADS v2.1) detected on a 3T prostate MRI scan at our Institution (June 2016–March 2021). An MRI-targeted biopsy was used as ground truth. We assessed reproducible mpMRI radiomic features found in the literature. Then, we proposed a new model combining PSA density and two radiomic features (texture regularity (T2) and size zone heterogeneity (ADC)). All models were trained/assessed through 100-repetitions 5-fold cross-validation. Eighty patients were included (26 with GS ≥ 7). In total, 9/20 T2 features (Hector’s model) and 1 T2 feature (Jin’s model) significantly correlated to biopsy on our dataset. PSA density alone predicted clinically significant tumors (sensitivity: 66%; specificity: 71%). Our model obtained a sensitivity of 80% and a specificity of 76%. Standard-compliant works with detailed methodologies achieve comparable radiomic feature sets. Therefore, efforts to facilitate reproducibility are needed, while complex models and imaging protocols seem not, since our model combining PSA density and two radiomic features from routinely performed sequences appeared to differentiate clinically significant cancers.
- Open Access
- 16 June 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1476
Superb Microvascular Imaging (SMI) Compared with Color Doppler Ultrasound for the Assessment of Hepatic Artery in Pediatric Liver Transplants: A Feasibility Study
(1) Background: Despite progression in surgical techniques and immunological treatments, hepatic artery (HA) thrombosis and stenosis still develop as an early or late liver transplant (LT) complication. We aimed to compare superb microvascular imaging (SMI) with conventional Doppler imaging (CDI) in the assessment of HA in a cohort of pediatric patients undergoing follow-up ultrasound (US) for LT. (2) Methods: This prospective, observational study included 73 pediatric LT recipients (median age, 7 years; IQR, 5.8 years; 35 females) who underwent US during LT follow-up from March to December 2019. For each examination, CDI and SMI were separately assessed in terms of HA visibility and spectral waveform morphology (SWM). The former was scored based on HA discrimination from the blooming signal of the surrounding vessels, as follows: 0, not visible; 1, majority course hardly distinguishable; and 2, majority course clearly distinguishable. The latter was scored on a two-point scale: 0, combined venous and arterial SWM, and 1, pure arterial SWM. The patient’s overall score was finally calculated by adding the two individual scores. (3) Results: Both the absolute scores and frequency of overall scores equal to 3 (maximum global score) were higher using SMI compared with CDI. The median overall score was 3 for SMI and 2 for CDI (p = 0.011; IQR = 1). An overall score equal to 3 was obtained in 74% and 49.3% of the study population using SMI and CDI, respectively (p = 0.002). This was attributable to a better score in HA visibility (p = 0.007). (4) Conclusions: SMI has shown promise for assessing HA in pediatric LT recipients, possibly serving as a complementary non-invasive tool of CDI in everyday practice.
- 16 June 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (6) , 1476
Open AccessSuperb Microvascular Imaging (SMI) Compared with Color Doppler Ultrasound for the Assessment of Hepatic Artery in Pediatric Liver Transplants: A Feasibility Study
(1) Background: Despite progression in surgical techniques and immunological treatments, hepatic artery (HA) thrombosis and stenosis still develop as an early or late liver transplant (LT) complication. We aimed to compare superb microvascular imaging (SMI) with conventional Doppler imaging (CDI) in the assessment of HA in a cohort of pediatric patients undergoing follow-up ultrasound (US) for LT. (2) Methods: This prospective, observational study included 73 pediatric LT recipients (median age, 7 years; IQR, 5.8 years; 35 females) who underwent US during LT follow-up from March to December 2019. For each examination, CDI and SMI were separately assessed in terms of HA visibility and spectral waveform morphology (SWM). The former was scored based on HA discrimination from the blooming signal of the surrounding vessels, as follows: 0, not visible; 1, majority course hardly distinguishable; and 2, majority course clearly distinguishable. The latter was scored on a two-point scale: 0, combined venous and arterial SWM, and 1, pure arterial SWM. The patient’s overall score was finally calculated by adding the two individual scores. (3) Results: Both the absolute scores and frequency of overall scores equal to 3 (maximum global score) were higher using SMI compared with CDI. The median overall score was 3 for SMI and 2 for CDI (p = 0.011; IQR = 1). An overall score equal to 3 was obtained in 74% and 49.3% of the study population using SMI and CDI, respectively (p = 0.002). This was attributable to a better score in HA visibility (p = 0.007). (4) Conclusions: SMI has shown promise for assessing HA in pediatric LT recipients, possibly serving as a complementary non-invasive tool of CDI in everyday practice.
- Open Access
- 28 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (4) , 825
Accuracy of Inflow Inversion Recovery (IFIR) for Upper Abdominal Arteries Evaluation: Comparison with Contrast-Enhanced MR and CTA
Background: Inflow-sensitive inversion recovery (IFIR) is a recently introduced technique to perform unenhanced magnetic resonance angiography (MRA). The purpose of our study is to determine the accuracy of IFIR-MRA in the evaluation of upper abdominal arteries, compared to standard MRA and computed tomography angiography (CTA). Materials and Methods: Seventy patients undergoing upper abdomen Magnetic Resonance Imaging (MRI) in different clinical settings were enrolled. The MRI protocol included an IFIR-MRA sequence that was intra-individually compared by using a qualitative 4-point scale in the same patients who underwent concomitant or close MRA (n = 65) and/or CTA (n = 44). Celiac trunk (CA), common-proper-left-right hepatic artery (C-P-L-R-HA), left gastric artery (LGA), gastroduodenal artery (GDA), splenic artery (SA), renal arteries (RA) and superior mesenteric artery (SMA) were assessed. Results: IFIR-MRA images were better rated in comparison with MRA. Particularly, all arteries obtained a statistically significant higher qualitative rating value (all p < 0.05). IFIR-MRA and MRA exhibited acceptable intraclass correlation coefficients (ICC) values for CA, C-L-R-HA, and SMA (ICC 0.507, 0.591, 0.615, 0.570, 0.525). IFIR-MRA and CTA showed significant correlations in C-P-L-R-HA (τ = 0.362, 0.261, 0.308, 0.307, respectively; p < 0.05), and in RA (τ = 0.279, p < 0.05). Conclusions: Compared to MRA, IFIR-MRA demonstrated a higher image quality in the majority of upper abdomen arterial vessels assessment. LHA and RHA branches could be better visualized with IFIR sequences, when visualizable. Based on these findings, we suggest to routinely integrate IFIR sequences in upper abdomen MRI studies.
- 28 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (4) , 825
Open AccessAccuracy of Inflow Inversion Recovery (IFIR) for Upper Abdominal Arteries Evaluation: Comparison with Contrast-Enhanced MR and CTA
Background: Inflow-sensitive inversion recovery (IFIR) is a recently introduced technique to perform unenhanced magnetic resonance angiography (MRA). The purpose of our study is to determine the accuracy of IFIR-MRA in the evaluation of upper abdominal arteries, compared to standard MRA and computed tomography angiography (CTA). Materials and Methods: Seventy patients undergoing upper abdomen Magnetic Resonance Imaging (MRI) in different clinical settings were enrolled. The MRI protocol included an IFIR-MRA sequence that was intra-individually compared by using a qualitative 4-point scale in the same patients who underwent concomitant or close MRA (n = 65) and/or CTA (n = 44). Celiac trunk (CA), common-proper-left-right hepatic artery (C-P-L-R-HA), left gastric artery (LGA), gastroduodenal artery (GDA), splenic artery (SA), renal arteries (RA) and superior mesenteric artery (SMA) were assessed. Results: IFIR-MRA images were better rated in comparison with MRA. Particularly, all arteries obtained a statistically significant higher qualitative rating value (all p < 0.05). IFIR-MRA and MRA exhibited acceptable intraclass correlation coefficients (ICC) values for CA, C-L-R-HA, and SMA (ICC 0.507, 0.591, 0.615, 0.570, 0.525). IFIR-MRA and CTA showed significant correlations in C-P-L-R-HA (τ = 0.362, 0.261, 0.308, 0.307, respectively; p < 0.05), and in RA (τ = 0.279, p < 0.05). Conclusions: Compared to MRA, IFIR-MRA demonstrated a higher image quality in the majority of upper abdomen arterial vessels assessment. LHA and RHA branches could be better visualized with IFIR sequences, when visualizable. Based on these findings, we suggest to routinely integrate IFIR sequences in upper abdomen MRI studies.