Agnese Innocenti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Agnese Innocenti has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Veronica Pazzi
Department of Earth Sciences, University of Florence, Florence, Italy
11 shared publications Riccardo Fanti
6 shared publicationsMarco Napoli
Department of Agriculture, Food, Environment and Forestry, University of Florence, Florence, Italy
3 shared publications- Riccardo Fanti
University of Florence
3 shared publications Simone Orlandini
Department of Agriculture, Food, Environment and Forestry, University of Florence, Florence, Italy
3 shared publicationsVeronica Pazzi
Department of Earth Sciences, University of Florence, Firenze, Italy
3 shared publications
Latest Publications
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
From apparent to real moisture index in masonry through inversion of microwave data: a first attempt
Nowadays, the preservation of cultural heritage has become a matter of debate, as numerous factors contribute to its deterioration. In this case, water plays a key role, as it can cause significant damage to construction materials over time. Direct measurements of water content (WC) are not feasible in cultural heritage buildings because they are destructive. Therefore, it is essential to apply methods which are non-destructive and also highly sensitive to the presence of water.Microwave-based moisture instruments utilize the transmission or reflection microwaves (i.e., electromagnetic waves in the frequency range: 0.3-300 GHz) to evaluate WC within materials. However, a major limitation of WC microwave measurements is that they provide cumulative moisture values that integrate the contribution of all material layers from the surface up to the probe’s penetration depth. As a result, previous studies have only relied on displaying cumulative moisture maps instead of the true ones.This work addresses this limitation by a simple least squares (LS) inversion approach based on an average weighted function, since no information about the actual weighting function implemented in the device is available. The forward model was assumed that the cumulative measurement at each penetration depth is of a weighted linear combination of moisture contributions from successive layers. Then, the LS solution was computed through the Moore-Penrose pseudoinverse to lead to the real WC at discrete depths without physical sampling.The method was applied to a real dataset acquired at the Certosa del Galluzzo (Florence, Italy), a 14th-century historical complex affected by moisture deterioration. The instrument used in this study was the Moist 350B sensor, designed by HF sensor GmbH (Leipzig, Germany). The device utilizes the transmission and reflection of electromagnetic waves in the range of microwave (approximately 2.45 GHz) to evaluate the WC within materials by measuring their dielectric permittivity. It is equipped with five interchangeable probes, which are used for detecting WC at different penetration depths: 3 cm, 7 cm, 11 cm, 30 cm, and 80 cm.First, the interest zones were identified by infrared thermography (IRT). Subsequently, the microwave sensor with all probes was applied to acquire cumulative data in these areas. Finally, synthetic Gaussian noise with a standard deviation of 1.5% (on the basis of the manual) was added to the dataset to simulate realistic measurement uncertainty prior to the inversion.The inverted data for the superficial layer (at 3 cm) reveal good agreement with the IRT results, whether the area is wet or dry. In addition, the results indicate that when a layer is highly saturated, the layer below will be significantly affected so that its moisture amount is lower compared to the acquired data. In fact, the presentation of raw data, especially in a highly saturated layer, causes the layer below to be considered overestimated compared to the real values. In summary, the proposed approach can effectively reconstruct the real distribution without any physical sampling.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessFrom apparent to real moisture index in masonry through inversion of microwave data: a first attempt
Nowadays, the preservation of cultural heritage has become a matter of debate, as numerous factors contribute to its deterioration. In this case, water plays a key role, as it can cause significant damage to construction materials over time. Direct measurements of water content (WC) are not feasible in cultural heritage buildings because they are destructive. Therefore, it is essential to apply methods which are non-destructive and also highly sensitive to the presence of water.Microwave-based moisture instruments utilize the transmission or reflection microwaves (i.e., electromagnetic waves in the frequency range: 0.3-300 GHz) to evaluate WC within materials. However, a major limitation of WC microwave measurements is that they provide cumulative moisture values that integrate the contribution of all material layers from the surface up to the probe’s penetration depth. As a result, previous studies have only relied on displaying cumulative moisture maps instead of the true ones.This work addresses this limitation by a simple least squares (LS) inversion approach based on an average weighted function, since no information about the actual weighting function implemented in the device is available. The forward model was assumed that the cumulative measurement at each penetration depth is of a weighted linear combination of moisture contributions from successive layers. Then, the LS solution was computed through the Moore-Penrose pseudoinverse to lead to the real WC at discrete depths without physical sampling.The method was applied to a real dataset acquired at the Certosa del Galluzzo (Florence, Italy), a 14th-century historical complex affected by moisture deterioration. The instrument used in this study was the Moist 350B sensor, designed by HF sensor GmbH (Leipzig, Germany). The device utilizes the transmission and reflection of electromagnetic waves in the range of microwave (approximately 2.45 GHz) to evaluate the WC within materials by measuring their dielectric permittivity. It is equipped with five interchangeable probes, which are used for detecting WC at different penetration depths: 3 cm, 7 cm, 11 cm, 30 cm, and 80 cm.First, the interest zones were identified by infrared thermography (IRT). Subsequently, the microwave sensor with all probes was applied to acquire cumulative data in these areas. Finally, synthetic Gaussian noise with a standard deviation of 1.5% (on the basis of the manual) was added to the dataset to simulate realistic measurement uncertainty prior to the inversion.The inverted data for the superficial layer (at 3 cm) reveal good agreement with the IRT results, whether the area is wet or dry. In addition, the results indicate that when a layer is highly saturated, the layer below will be significantly affected so that its moisture amount is lower compared to the acquired data. In fact, the presentation of raw data, especially in a highly saturated layer, causes the layer below to be considered overestimated compared to the real values. In summary, the proposed approach can effectively reconstruct the real distribution without any physical sampling.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
The influence of the Electrodes-Spacing-to-Diameter-Ratio (ES2DR) on ERT measurements: an operational approach
Electrical Resistivity Tomography (ERT) is widely used in archaeo-geophysics due to its capability to non-invasively detect buried structures and stratigraphic heterogeneities. However, when ERT is applied to shallow, small-scale archaeological targets requiring high spatial resolution, the finite geometry of electrodes and the reduced inter electrodes distance can introduce systematic errors that may be misinterpreted as cultural features. This study investigates the impact of the electrode spacing to diameter ratio (a/φ) on apparent resistivity measurements, with particular attention to conditions typical of archaeological prospection, where electrode spacing is often limited by site constraints and preservation requirements. Six electrode types with diameters ranging from 4 to 16 mm were tested using dipole–dipole and pole–dipole arrays at four electrode spacings (10, 30, 50, and 100 cm), generating 48 ERT datasets acquired over a mainly homogeneous test area, characterised by the presence of a higher resistive target. The analysis focused on apparent resistivity values to avoid uncertainties introduced by inversion procedures.Results demonstrate that electrode material does not significantly influence resistivity measurements; instead, geometric factors dominate. In particular, when a/φ il lower than 25 (φ/a ≥ 4%), corresponding to dense electrode setups frequently used in archaeological ERT, apparent resistivity is strongly affected, particularly at shallow depths and in the presence of resistive anomalies (e.g., conditions typical of buildings, voids, pavements, foundation remains, or anthropogenic stratigraphy). When a/φ is higher than 31.5 (φ/a ≤ 3.2%), electrode diameter has negligible impact, confirming that standard ERT configurations at meter-scale spacing are generally robust. Increased variability and systematic deviations were observed up to approximately three times the electrode spacing, potentially generating artificial resistive highs that could be erroneously interpreted as archaeological features. Intermediate spacing values (30–50 cm) show transitional behaviour, with distortions decreasing progressively with depth.The study provides an operational framework for archaeo-geophysical practice: (1) electrode diameter becomes critical when small electrode spacing is required; (2) reliable shallow imaging in archaeological contexts demands maintaining sufficiently high a/φ ratios or explicitly modelling electrode geometry; and (3) resistive archaeological targets are most susceptible to artifact generation under inadequate a/φ conditions. These findings support improved survey design, more reliable interpretation of near-surface ERT data, and reduced risk of false positives in cultural heritage investigations.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessThe influence of the Electrodes-Spacing-to-Diameter-Ratio (ES2DR) on ERT measurements: an operational approach
Electrical Resistivity Tomography (ERT) is widely used in archaeo-geophysics due to its capability to non-invasively detect buried structures and stratigraphic heterogeneities. However, when ERT is applied to shallow, small-scale archaeological targets requiring high spatial resolution, the finite geometry of electrodes and the reduced inter electrodes distance can introduce systematic errors that may be misinterpreted as cultural features. This study investigates the impact of the electrode spacing to diameter ratio (a/φ) on apparent resistivity measurements, with particular attention to conditions typical of archaeological prospection, where electrode spacing is often limited by site constraints and preservation requirements. Six electrode types with diameters ranging from 4 to 16 mm were tested using dipole–dipole and pole–dipole arrays at four electrode spacings (10, 30, 50, and 100 cm), generating 48 ERT datasets acquired over a mainly homogeneous test area, characterised by the presence of a higher resistive target. The analysis focused on apparent resistivity values to avoid uncertainties introduced by inversion procedures.Results demonstrate that electrode material does not significantly influence resistivity measurements; instead, geometric factors dominate. In particular, when a/φ il lower than 25 (φ/a ≥ 4%), corresponding to dense electrode setups frequently used in archaeological ERT, apparent resistivity is strongly affected, particularly at shallow depths and in the presence of resistive anomalies (e.g., conditions typical of buildings, voids, pavements, foundation remains, or anthropogenic stratigraphy). When a/φ is higher than 31.5 (φ/a ≤ 3.2%), electrode diameter has negligible impact, confirming that standard ERT configurations at meter-scale spacing are generally robust. Increased variability and systematic deviations were observed up to approximately three times the electrode spacing, potentially generating artificial resistive highs that could be erroneously interpreted as archaeological features. Intermediate spacing values (30–50 cm) show transitional behaviour, with distortions decreasing progressively with depth.The study provides an operational framework for archaeo-geophysical practice: (1) electrode diameter becomes critical when small electrode spacing is required; (2) reliable shallow imaging in archaeological contexts demands maintaining sufficiently high a/φ ratios or explicitly modelling electrode geometry; and (3) resistive archaeological targets are most susceptible to artifact generation under inadequate a/φ conditions. These findings support improved survey design, more reliable interpretation of near-surface ERT data, and reduced risk of false positives in cultural heritage investigations.
- Open Access
- 9 October 2025
- Published by Springer Nature in Landslides
- Vol. 23 (2) , 351-368
Geophysical reconnaissance of the Pays de Herve landslides, Belgium: case study of three active paleo-slides in a dissected tableland
The Pays de Herve region in East Belgium is characterised by widespread slope instability. Some of these Quaternary paleo-landslides are still active, showing subsidence phenomena that can be related to the presence of weak subsurface materials such as clays (locally topped by weathered chalk) overlying a discontinuous sand-silt layer. This study provides a detailed characterisation of three active landslides in the area, with a particular focus on the Manaihan landslide, which is the most active and has also caused damage to surrounding buildings. To investigate these landslides, an integrated geophysical approach was applied, combining electrical resistivity tomography, P-wave seismic refraction, multichannel analysis of surface waves, and microseismic ambient noise measurements (H/V analysis). Each method has intrinsic limitations, but their combined use allowed for a comprehensive analysis of the sliding surfaces. While the first three techniques provided detailed information on limited sectors of each landslide, the ambient noise measurements enabled the coverage of the entire landslide areas. This integrated approach, combining microseismic ambient noise frequency analysis, allowed for a detailed mapping of the Manaihan landslide’s subsurface and the creation of a 3D geological model of the site. The results align well with the geophysical imagery collected, allowing the precise identification of the landslide bases and enhancing the understanding of the subsurface structure in the Pays de Herve region.
- 9 October 2025
- Published by Springer Nature in Landslides
- Vol. 23 (2) , 351-368
Open AccessGeophysical reconnaissance of the Pays de Herve landslides, Belgium: case study of three active paleo-slides in a dissected tableland
The Pays de Herve region in East Belgium is characterised by widespread slope instability. Some of these Quaternary paleo-landslides are still active, showing subsidence phenomena that can be related to the presence of weak subsurface materials such as clays (locally topped by weathered chalk) overlying a discontinuous sand-silt layer. This study provides a detailed characterisation of three active landslides in the area, with a particular focus on the Manaihan landslide, which is the most active and has also caused damage to surrounding buildings. To investigate these landslides, an integrated geophysical approach was applied, combining electrical resistivity tomography, P-wave seismic refraction, multichannel analysis of surface waves, and microseismic ambient noise measurements (H/V analysis). Each method has intrinsic limitations, but their combined use allowed for a comprehensive analysis of the sliding surfaces. While the first three techniques provided detailed information on limited sectors of each landslide, the ambient noise measurements enabled the coverage of the entire landslide areas. This integrated approach, combining microseismic ambient noise frequency analysis, allowed for a detailed mapping of the Manaihan landslide’s subsurface and the creation of a 3D geological model of the site. The results align well with the geophysical imagery collected, allowing the precise identification of the landslide bases and enhancing the understanding of the subsurface structure in the Pays de Herve region.
- Open Access
- 15 March 2025
- Published by Copernicus GmbH
Seismic noise measurements for the characterisation of Pays de Herve landslides
The Pays de Herve, located in the eastern part of Belgium, can be characterized as a multiple sections tableland with gentle slopes of less than 15°. It is located in the vicinity of the northern section of the Hockai Fault Zone, a 42 km-long seismogenic fault zone, that is characterized by the presence of fault scarps, multiple dissection elements and the presence of more than 20 paleo-landslides. Among these latter, the Manaihan landslide is the most studied and monitored landslide in the area. From a geological point of view, it developed in a Upper Cretaceous sedimentary setting, i.e., Vaals Clays overlaying Aachen sands. Even today, the slope is affected by instability and subsidence phenomena, likely linked to anthropogenic loading combined with prolonged periods of rainfall and possibly historic seismic events leading to liquefaction in the Aachen sands.Recently, new geophysical surveys have been carried out using an integrated approach, combining electrical resistivity measurements, active seismic methods (interpreted as P-wave tomography and MASW), and passive seismic techniques (single-station H/V). The key question to address is: How deep is the sliding surface, and is it possible to identify it?The combination of these surveys allowed the identification of two main layers. The first layer has a variable thickness ranging between 5 m and 20 m. On the electrical resistivity tomography, it corresponds to a more conductive layer with values between 5 and 20 Ωm, and on the seismic tomography, it shows velocities between 500 and 1300 m/s. From the electrical and seismic tomographies, the second layer appears to be more resistive, with values ranging between 30 and 50 Ωm, and P-wave velocities exceed 1500 m/s. Based on the geological map and their physical properties, the identified layers have been attributed to the Vaals clay formation and the Aachen sands, respectively.The H/V measurements were processed to produce sections showing the variation of H/V amplitude (or the log of H/V) with depth. If multiple H/V measurements can be aligned in a linear array and the surface layer can be assumed to be homogeneous, i.e., shear wave velocity increasing with depth, the H/V curves along the alignment can be modeled together to create a 2D section. Several H/V sections could be developed for the Manaihan landslide, revealing a similar pattern of contrasts between the before mentioned layers. The main contrast is located at a depth ranging from 15 m to 40 m and corresponds to the interfaces identified by ERT and SRT. This interface is present beyond the landslide and even outside of it, suggesting that it may be associated to the geological contact between the Vaals clays and the Aachen sands. The conductive layer identified in the ERTs can furthermore be associated to very low log H/V amplitudes in the upper range of the H/V sections until 10-20 m depth. The H/V amplitude analysis of all the identified sections suggests that the sliding surface of the Manaihan landslide is located at the contact between the clay and the sand layers.
- 15 March 2025
- Published by Copernicus GmbH
Open AccessSeismic noise measurements for the characterisation of Pays de Herve landslides
The Pays de Herve, located in the eastern part of Belgium, can be characterized as a multiple sections tableland with gentle slopes of less than 15°. It is located in the vicinity of the northern section of the Hockai Fault Zone, a 42 km-long seismogenic fault zone, that is characterized by the presence of fault scarps, multiple dissection elements and the presence of more than 20 paleo-landslides. Among these latter, the Manaihan landslide is the most studied and monitored landslide in the area. From a geological point of view, it developed in a Upper Cretaceous sedimentary setting, i.e., Vaals Clays overlaying Aachen sands. Even today, the slope is affected by instability and subsidence phenomena, likely linked to anthropogenic loading combined with prolonged periods of rainfall and possibly historic seismic events leading to liquefaction in the Aachen sands.Recently, new geophysical surveys have been carried out using an integrated approach, combining electrical resistivity measurements, active seismic methods (interpreted as P-wave tomography and MASW), and passive seismic techniques (single-station H/V). The key question to address is: How deep is the sliding surface, and is it possible to identify it?The combination of these surveys allowed the identification of two main layers. The first layer has a variable thickness ranging between 5 m and 20 m. On the electrical resistivity tomography, it corresponds to a more conductive layer with values between 5 and 20 Ωm, and on the seismic tomography, it shows velocities between 500 and 1300 m/s. From the electrical and seismic tomographies, the second layer appears to be more resistive, with values ranging between 30 and 50 Ωm, and P-wave velocities exceed 1500 m/s. Based on the geological map and their physical properties, the identified layers have been attributed to the Vaals clay formation and the Aachen sands, respectively.The H/V measurements were processed to produce sections showing the variation of H/V amplitude (or the log of H/V) with depth. If multiple H/V measurements can be aligned in a linear array and the surface layer can be assumed to be homogeneous, i.e., shear wave velocity increasing with depth, the H/V curves along the alignment can be modeled together to create a 2D section. Several H/V sections could be developed for the Manaihan landslide, revealing a similar pattern of contrasts between the before mentioned layers. The main contrast is located at a depth ranging from 15 m to 40 m and corresponds to the interfaces identified by ERT and SRT. This interface is present beyond the landslide and even outside of it, suggesting that it may be associated to the geological contact between the Vaals clays and the Aachen sands. The conductive layer identified in the ERTs can furthermore be associated to very low log H/V amplitudes in the upper range of the H/V sections until 10-20 m depth. The H/V amplitude analysis of all the identified sections suggests that the sliding surface of the Manaihan landslide is located at the contact between the clay and the sand layers.
- Open Access
- 15 March 2025
- Published by Copernicus GmbH
Transforming electrical resistivity tomographies into volumetric water content ones: a strategy for optimizing irrigation in horticulture.
Agricultural water management is becoming an increasingly actual issue in a period of severe climate changings. Sustainable water management requires adequate knowledge of soil water availability and its storage capacity.The correct management of irrigation water requires a good knowledge of the volumetric water content (VWC) in the soil. VWC is a parameter that can be measured using soil humidity sensors, and it can help understanding how the irrigation water distributes in the soil. However, these sensors are point humidity monitoring systems, that means they provide information limited to the vertical where they are installed and do not allow a 2D or 3D reconstruction of the water content in the subsoil. As well known, Electrical Resistivity Tomographies (ERT), a non-invasive geophysical method, estimates the spatial and temporal variations of soil resistivity (and thus of its inverse, i.e., conductivity), which is linked to parameters such as water content. Unlike point-based soil moisture sensors, ERT provides a broader view of water distribution in the soil. Thus, the goal of this study was to use electrical conductivity (EC) by full 3D-ERTs and moisture sensors to estimate the volumetric water content in the soil.The study was conducted in a field dedicated to melon cultivation, where a detailed study of the irrigation system has been carried out over the years. It was determined that the three-drip-line system with a capacity of 4.1 lh/m² is the best irrigation system for this field located in Braccagni (GR, Italy). Therefore, one plot of the field was equipped with a three-drip-line irrigation system, and 72 electrodes were installed to perform full 3D-ERT measurements. Additionally, two PVC tubes, sealed at the base and with an opening at the surface, were installed to allow the insertion of the Diviner2000 probe and to measure soil moisture every 10 cm down to a maximum depth of 70 cm. Two ECH2O 10 HS sensors were also installed, connected to a data logger capable of recording temperature and moisture measurements every 30 min. The sensors, 15 cm in length, were installed vertically in the soil, allowing the measurement of VWC in a soil volume of 0.001 m³.Between June and August 2023, six measurement campaigns of electrical conductivity were conducted. It is known that there is a direct relationship between EC and VWC. Therefore, the VWC data recorded by the Diviner2000 for all six acquisition times were correlated with the EC data acquired by ERTs. The two datasets (EC from ERT and VWC from Diviner2000) are in perfect agreement, showing a linear relationship with a R² of 0.96. Using the obtained regression law, it is possible to convert EC tomographies into VWC tomographies, thereby visualizing the variation of water content in the subsoil. This made it possible to understand the water distribution within the plot and to determine the percentage of water present throughout the entire root zone, not just at the points where the moisture sensors are installed.
- 15 March 2025
- Published by Copernicus GmbH
Open AccessTransforming electrical resistivity tomographies into volumetric water content ones: a strategy for optimizing irrigation in horticulture.
Agricultural water management is becoming an increasingly actual issue in a period of severe climate changings. Sustainable water management requires adequate knowledge of soil water availability and its storage capacity.The correct management of irrigation water requires a good knowledge of the volumetric water content (VWC) in the soil. VWC is a parameter that can be measured using soil humidity sensors, and it can help understanding how the irrigation water distributes in the soil. However, these sensors are point humidity monitoring systems, that means they provide information limited to the vertical where they are installed and do not allow a 2D or 3D reconstruction of the water content in the subsoil. As well known, Electrical Resistivity Tomographies (ERT), a non-invasive geophysical method, estimates the spatial and temporal variations of soil resistivity (and thus of its inverse, i.e., conductivity), which is linked to parameters such as water content. Unlike point-based soil moisture sensors, ERT provides a broader view of water distribution in the soil. Thus, the goal of this study was to use electrical conductivity (EC) by full 3D-ERTs and moisture sensors to estimate the volumetric water content in the soil.The study was conducted in a field dedicated to melon cultivation, where a detailed study of the irrigation system has been carried out over the years. It was determined that the three-drip-line system with a capacity of 4.1 lh/m² is the best irrigation system for this field located in Braccagni (GR, Italy). Therefore, one plot of the field was equipped with a three-drip-line irrigation system, and 72 electrodes were installed to perform full 3D-ERT measurements. Additionally, two PVC tubes, sealed at the base and with an opening at the surface, were installed to allow the insertion of the Diviner2000 probe and to measure soil moisture every 10 cm down to a maximum depth of 70 cm. Two ECH2O 10 HS sensors were also installed, connected to a data logger capable of recording temperature and moisture measurements every 30 min. The sensors, 15 cm in length, were installed vertically in the soil, allowing the measurement of VWC in a soil volume of 0.001 m³.Between June and August 2023, six measurement campaigns of electrical conductivity were conducted. It is known that there is a direct relationship between EC and VWC. Therefore, the VWC data recorded by the Diviner2000 for all six acquisition times were correlated with the EC data acquired by ERTs. The two datasets (EC from ERT and VWC from Diviner2000) are in perfect agreement, showing a linear relationship with a R² of 0.96. Using the obtained regression law, it is possible to convert EC tomographies into VWC tomographies, thereby visualizing the variation of water content in the subsoil. This made it possible to understand the water distribution within the plot and to determine the percentage of water present throughout the entire root zone, not just at the points where the moisture sensors are installed.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Electrical Resistivity Tomography (ERT) to monitor the efficiency of different irrigation systems in horticulture field
Water management in agricultural systems is essential for optimal crop yields without incurring excessive water costs and wastage. The choice of irrigation method is crucial for better water management and distribution. The drip system appears to be among the best methods in the field of precision agriculture. In addition to the irrigation system, mulching with ridge plastic film to drain excess water is widely used to increase crop yields in terms of plant water availability.In this study, the time-lapse Electrical Resistivity Tomography (ERT), a not-invasive geophysical technique, is proposed as a simple and reliable method to evaluate the effectiveness of the irrigation systems and to monitor the changes in water content over time and over a volume of soil. ERTs data were compared to moisture one retrieved from sensors that record continuously over time, but punctually. The ERT investigations were conducted in melon-growing lands in southern Tuscany (Italy).The aim of the work was to evaluate, by means of volumetric measures of the soil conductivity, the effectiveness of three different drip systems and of the mulch ridge: a two-wings drip system and a three-wings drip line with the same flow rate and a three-wings drip lines with a higher flow, in two different seasonal periods (spring and summer). In both the monitored fields the ridge was created in a half portion of the field itself, while in the other part the land was left plat.The data collected showed that the 2-wing system was particularly ineffective, and that the distribution of irrigation water favoured some areas more than others. While they led to satisfactory results for the 3-wing system and same water flow than two wings and the 3-wing system and highest water flow. The first system has shown that the same quantity of water as the classic irrigations system (two wings) distributed over three wings instead of two leads to a greater concentration of water in the root zone over time, slowly draining downwards. On the contrary, the second system distributes the water uniformly like the first system, but the quantity introduced was excessive, leading the soil to always be positioned above the field capacity and draining a lot of water downwards. The excessive accumulation of water below the root zone represents a waste of water, as this cannot be used by the root system. The tests, in addition to considering which system was optimal, also evaluated the effectiveness of the mulch ridge, leading to the deduction that during the spring season a ridge of height equal to or greater than 20 cm is to be considered better than a ridge of less than 20 cm or absent, as it allows excess water, represented by rainfall, to be drained. However, during the summer period, when rainfall is less if not absent, the presence of a much lower ridge (around 10 cm in height) is much more effective as it allows the irrigation water to be retained at the root system avoiding excessive drainage.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessElectrical Resistivity Tomography (ERT) to monitor the efficiency of different irrigation systems in horticulture field
Water management in agricultural systems is essential for optimal crop yields without incurring excessive water costs and wastage. The choice of irrigation method is crucial for better water management and distribution. The drip system appears to be among the best methods in the field of precision agriculture. In addition to the irrigation system, mulching with ridge plastic film to drain excess water is widely used to increase crop yields in terms of plant water availability.In this study, the time-lapse Electrical Resistivity Tomography (ERT), a not-invasive geophysical technique, is proposed as a simple and reliable method to evaluate the effectiveness of the irrigation systems and to monitor the changes in water content over time and over a volume of soil. ERTs data were compared to moisture one retrieved from sensors that record continuously over time, but punctually. The ERT investigations were conducted in melon-growing lands in southern Tuscany (Italy).The aim of the work was to evaluate, by means of volumetric measures of the soil conductivity, the effectiveness of three different drip systems and of the mulch ridge: a two-wings drip system and a three-wings drip line with the same flow rate and a three-wings drip lines with a higher flow, in two different seasonal periods (spring and summer). In both the monitored fields the ridge was created in a half portion of the field itself, while in the other part the land was left plat.The data collected showed that the 2-wing system was particularly ineffective, and that the distribution of irrigation water favoured some areas more than others. While they led to satisfactory results for the 3-wing system and same water flow than two wings and the 3-wing system and highest water flow. The first system has shown that the same quantity of water as the classic irrigations system (two wings) distributed over three wings instead of two leads to a greater concentration of water in the root zone over time, slowly draining downwards. On the contrary, the second system distributes the water uniformly like the first system, but the quantity introduced was excessive, leading the soil to always be positioned above the field capacity and draining a lot of water downwards. The excessive accumulation of water below the root zone represents a waste of water, as this cannot be used by the root system. The tests, in addition to considering which system was optimal, also evaluated the effectiveness of the mulch ridge, leading to the deduction that during the spring season a ridge of height equal to or greater than 20 cm is to be considered better than a ridge of less than 20 cm or absent, as it allows excess water, represented by rainfall, to be drained. However, during the summer period, when rainfall is less if not absent, the presence of a much lower ridge (around 10 cm in height) is much more effective as it allows the irrigation water to be retained at the root system avoiding excessive drainage.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Geophysical survey for the estimation of geotechnical parameters and for the stability assessment of the Tehilly landslide (VdA, Italy)
An efficient stability analysis is closely linked to a good assignment of geotechnical parameters to the strata identified in the construction of the geological model. However, it is not always possible to determine the geotechnical parameters from direct tests, but there are indirect methods in the literature for determining the main geotechnical parameters of the ground using seismic parameters such as seismic velocities.Numerous correlations exist in the literature between shear wave velocity (VS), and the N-SPT value derived from penetrometric tests.This study presents the geotechnical model of the Theilly landslide (Western Alps, Italy) obtained by integrating the results of a multi-parameter geophysical survey (H/V seismic noise and ground-penetrating radar) with stratigraphic and geomorphologic observations, digital terrain model and field survey data. It is shown how VS values can be related to values obtained from direct tests such as N-SPT and, using the direct or estimated N-SPT value, it is possible to directly derive the friction angle value (φ'). Although, the indirect estimation of N-SPT is subject to a higher level of error, it could be very useful in the early stages of an emergency, when direct data are not available, and a preliminary forward and backward stability analysis could be performed to assess landslide evolution and civil protection actions.Geophysical surveys were conducted on the landslide body and on nearby locations. The H/V survey identified the presence of 2 discontinuity surfaces and thus the presence of 3 seismo-layers. The GPR survey allowed the surface portion of the slope to be studied, identifying an extremely heterogeneous debris layer.The H/V data allowed the interface depth to be related to the frequency of the identified peaks and the VS of the identified seismic layers. It was then possible to apply empirical equations to derive the value of N-SPT, and consequently φ', from the VS obtained through the H/V measurements.The geotechnical parameters obtained from geophysical and direct tests were used to create a geotechnical model of the landslide to perform a reliable stability analysis. The analysis of the triggering conditions of the landslide was conducted through hydrologic-geotechnical modelling, evaluating the behaviour of the slope under different rainfall scenarios, and considering the stabilization interventions present on the slope.The results of the filtration analyses showed a top-down saturation mechanism, which resulted in the generation of positive pore water pressure in the first few meters of soil and the formation of a saturated front with a maximum thickness of 5 m. Stability analyses conducted for the same events showed the development of a shallow landslide affecting the first few meters of saturated soil.The geotechnical parameters estimated from the geophysical tests are in agreement with the data from the direct tests and have made it possible to create a geotechnical model that is faithful to reality.The modelling results are compatible with the actual evolution of the phenomenon and have provided insight into the triggering mechanism, providing models to support future interventions.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessGeophysical survey for the estimation of geotechnical parameters and for the stability assessment of the Tehilly landslide (VdA, Italy)
An efficient stability analysis is closely linked to a good assignment of geotechnical parameters to the strata identified in the construction of the geological model. However, it is not always possible to determine the geotechnical parameters from direct tests, but there are indirect methods in the literature for determining the main geotechnical parameters of the ground using seismic parameters such as seismic velocities.Numerous correlations exist in the literature between shear wave velocity (VS), and the N-SPT value derived from penetrometric tests.This study presents the geotechnical model of the Theilly landslide (Western Alps, Italy) obtained by integrating the results of a multi-parameter geophysical survey (H/V seismic noise and ground-penetrating radar) with stratigraphic and geomorphologic observations, digital terrain model and field survey data. It is shown how VS values can be related to values obtained from direct tests such as N-SPT and, using the direct or estimated N-SPT value, it is possible to directly derive the friction angle value (φ'). Although, the indirect estimation of N-SPT is subject to a higher level of error, it could be very useful in the early stages of an emergency, when direct data are not available, and a preliminary forward and backward stability analysis could be performed to assess landslide evolution and civil protection actions.Geophysical surveys were conducted on the landslide body and on nearby locations. The H/V survey identified the presence of 2 discontinuity surfaces and thus the presence of 3 seismo-layers. The GPR survey allowed the surface portion of the slope to be studied, identifying an extremely heterogeneous debris layer.The H/V data allowed the interface depth to be related to the frequency of the identified peaks and the VS of the identified seismic layers. It was then possible to apply empirical equations to derive the value of N-SPT, and consequently φ', from the VS obtained through the H/V measurements.The geotechnical parameters obtained from geophysical and direct tests were used to create a geotechnical model of the landslide to perform a reliable stability analysis. The analysis of the triggering conditions of the landslide was conducted through hydrologic-geotechnical modelling, evaluating the behaviour of the slope under different rainfall scenarios, and considering the stabilization interventions present on the slope.The results of the filtration analyses showed a top-down saturation mechanism, which resulted in the generation of positive pore water pressure in the first few meters of soil and the formation of a saturated front with a maximum thickness of 5 m. Stability analyses conducted for the same events showed the development of a shallow landslide affecting the first few meters of saturated soil.The geotechnical parameters estimated from the geophysical tests are in agreement with the data from the direct tests and have made it possible to create a geotechnical model that is faithful to reality.The modelling results are compatible with the actual evolution of the phenomenon and have provided insight into the triggering mechanism, providing models to support future interventions.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Correlating different evaluation methods for SWC as support for soil processes modelling
Soil erosion modelling has a large sensitivity to soil water content as it greatly affects soil erodibility. Knowing soil moisture and water content along a soil profile can help to understand the soil ability to absorb water before runoff occurs, then, to predict runoff and potential erosion.This study presents a combined approach of direct and indirect methods to monitor soil moisture content on a slope, with the goal of using this data in the future for modelling water erosion processes in soils.Generally, soil moisture data used for erosion models can be acquired through direct methods (e.g., gravimetric method, time or frequency domain reflectometry, moisture sensors) and/or indirect methods (meteorological data, remote sensing, electrical conductivity).In this research project, an experiment was carried out with the aim of combining direct and indirect methods to maximize the information on the rate of change of soil moisture in a 9*9 m plot by exploring depths from 0 to 50 cm. We used the water content sensor, SoilVUE10 by Campbell, recently released on the market, and based on Time Domain Reflectometry (TDR) technology conjointly with the Electrical Resistivity Tomography (ERT). Moisture sensors are known to create a disturbance in the ground, while geophysical techniques such as ERT are indirect, non-destructive measurements. Furthermore, they have the great advantage of being able to investigate a significantly larger area than classic humidity sensors.The conductivity varied in average between 0.02 and 0.08 S/m with a little more evident relationship between the values measured with the two methods in deeper layers than at soil surface (i.e., r=0.31 at -30cm).Overall, further investigations will be conducted, the ERT system needs data acquisition integration, i.e., remote data acquisition so that much more data can be acquired (at least one data set per day). The moisture values acquired by the SoilVUE10 probe require further analysis and comparison, possibly with other TDR probes. Furthermore, it may be necessary to install a surface moisture sensor capable to improve data acquisition even for the first 10cm soil layer.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessCorrelating different evaluation methods for SWC as support for soil processes modelling
Soil erosion modelling has a large sensitivity to soil water content as it greatly affects soil erodibility. Knowing soil moisture and water content along a soil profile can help to understand the soil ability to absorb water before runoff occurs, then, to predict runoff and potential erosion.This study presents a combined approach of direct and indirect methods to monitor soil moisture content on a slope, with the goal of using this data in the future for modelling water erosion processes in soils.Generally, soil moisture data used for erosion models can be acquired through direct methods (e.g., gravimetric method, time or frequency domain reflectometry, moisture sensors) and/or indirect methods (meteorological data, remote sensing, electrical conductivity).In this research project, an experiment was carried out with the aim of combining direct and indirect methods to maximize the information on the rate of change of soil moisture in a 9*9 m plot by exploring depths from 0 to 50 cm. We used the water content sensor, SoilVUE10 by Campbell, recently released on the market, and based on Time Domain Reflectometry (TDR) technology conjointly with the Electrical Resistivity Tomography (ERT). Moisture sensors are known to create a disturbance in the ground, while geophysical techniques such as ERT are indirect, non-destructive measurements. Furthermore, they have the great advantage of being able to investigate a significantly larger area than classic humidity sensors.The conductivity varied in average between 0.02 and 0.08 S/m with a little more evident relationship between the values measured with the two methods in deeper layers than at soil surface (i.e., r=0.31 at -30cm).Overall, further investigations will be conducted, the ERT system needs data acquisition integration, i.e., remote data acquisition so that much more data can be acquired (at least one data set per day). The moisture values acquired by the SoilVUE10 probe require further analysis and comparison, possibly with other TDR probes. Furthermore, it may be necessary to install a surface moisture sensor capable to improve data acquisition even for the first 10cm soil layer.
- Open Access
- 18 March 2024
- Published by Springer Nature in Irrigation Science
- Vol. 43 (6) , 1437-1451
Assessing the efficiency of the irrigation system in a horticulture field through time-lapse electrical resistivity tomography
The characterization by means of geophysical techniques of agricultural soils subjected to continuous irrigation cycles makes it possible to study the heterogeneity of a soil and the preferential pathways of water flows without disturbing soil and plants. A better knowledge of soil heterogeneity enables optimal water resource management in terms of crop, yield, and sustainability. In this study, time-lapse monitoring using electrical resistivity tomographies (ERT) is proposed as a reliable and non-invasive technique to quantify the movement of water flows and thus the variation of soil water content during the irrigation process. ERT surveys have been conducted in melon-growing soils in southern Tuscany (Italy). Five survey campaigns have been carried out between June and August 2022, in which ERT data have been collected by taking measurements before ( T 0 ), during ( T 1 ), and after ( T 2 ) the irrigation phase. The interpretation of the ERT results provided information on the spatial and temporal distribution of water fluxes in the soil and root zone of melons during the irrigation phases. The investigation made it possible to identify the preferential pathways of infiltration of irrigation water, the points where water is absorbed by the roots, and the points where water follows a preferential pathway instead distributing itself entirely below the root growth zone. Thus, this research suggests that the ERT technique can be used to evaluate the efficiency of the irrigation system in order to achieve optimal management of the water resource, avoiding preferential flow paths that lead to less water availability for the plant.
- 18 March 2024
- Published by Springer Nature in Irrigation Science
- Vol. 43 (6) , 1437-1451
Open AccessAssessing the efficiency of the irrigation system in a horticulture field through time-lapse electrical resistivity tomography
The characterization by means of geophysical techniques of agricultural soils subjected to continuous irrigation cycles makes it possible to study the heterogeneity of a soil and the preferential pathways of water flows without disturbing soil and plants. A better knowledge of soil heterogeneity enables optimal water resource management in terms of crop, yield, and sustainability. In this study, time-lapse monitoring using electrical resistivity tomographies (ERT) is proposed as a reliable and non-invasive technique to quantify the movement of water flows and thus the variation of soil water content during the irrigation process. ERT surveys have been conducted in melon-growing soils in southern Tuscany (Italy). Five survey campaigns have been carried out between June and August 2022, in which ERT data have been collected by taking measurements before ( T 0 ), during ( T 1 ), and after ( T 2 ) the irrigation phase. The interpretation of the ERT results provided information on the spatial and temporal distribution of water fluxes in the soil and root zone of melons during the irrigation phases. The investigation made it possible to identify the preferential pathways of infiltration of irrigation water, the points where water is absorbed by the roots, and the points where water follows a preferential pathway instead distributing itself entirely below the root growth zone. Thus, this research suggests that the ERT technique can be used to evaluate the efficiency of the irrigation system in order to achieve optimal management of the water resource, avoiding preferential flow paths that lead to less water availability for the plant.
- Open Access
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Considerations on the Electrode-Spacing-to-Electrode-Diameter Ratio in Electrical Resistivity Tomography (ERT): An Operational Approach
To develop small-scale, shallow, and high-resolution electrical resistivity surveys (e.g., for archaeological or agricultural purposes) the available literature highlights few requirements in terms of distance between two adjacent electrodes or electrode’s length embedded in the soil. Nevertheless, there are no studies about the influence of the electrode’s diameter and/or the electrode’s diameter to electrode spacing ratio. Thus, this work proposes to investigate this ratio in relatively small-scale surveys (electrode spacing from 10 cm to 100 cm) to define an operational approach. The analysis has been conducted comparing the apparent resistivity data acquired by means of electrodes different in terms of diameter and materials. The apparent resistivity was chosen to avoid the introduction of further errors/approximations caused by the inversion procedure. Overall, six different types of electrodes have been employed and tested. The results of the data analysis emphasize the necessity of take into account the electrode diameter to electrode spacing ratio in the case of small-case Electrical Resistivity Tomography (ERT) surveys.
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Open AccessConsiderations on the Electrode-Spacing-to-Electrode-Diameter Ratio in Electrical Resistivity Tomography (ERT): An Operational Approach
To develop small-scale, shallow, and high-resolution electrical resistivity surveys (e.g., for archaeological or agricultural purposes) the available literature highlights few requirements in terms of distance between two adjacent electrodes or electrode’s length embedded in the soil. Nevertheless, there are no studies about the influence of the electrode’s diameter and/or the electrode’s diameter to electrode spacing ratio. Thus, this work proposes to investigate this ratio in relatively small-scale surveys (electrode spacing from 10 cm to 100 cm) to define an operational approach. The analysis has been conducted comparing the apparent resistivity data acquired by means of electrodes different in terms of diameter and materials. The apparent resistivity was chosen to avoid the introduction of further errors/approximations caused by the inversion procedure. Overall, six different types of electrodes have been employed and tested. The results of the data analysis emphasize the necessity of take into account the electrode diameter to electrode spacing ratio in the case of small-case Electrical Resistivity Tomography (ERT) surveys.