SOSergio Ortiz

Sergio Ortiz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sergio Ortiz has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Metal-free conductive inks based on biodegradable hydrogels for direct ink writing of flexible circuits

    by Álvaro Méndez-Espinosa, Sergio Ortiz-Ruiz, Mikel G Palomo, Francisco Pasadas, Laura Rodríguez-Arco, Modesto T López-López, Francisco G Ruiz

    Metal-free conductive inks based on biodegradable hydrogels for direct ink writing of flexible circuits, Méndez-Espinosa, Álvaro, Ortiz-Ruiz, Sergio, Palomo, Mikel G, Pasadas, Francisco, Rodríguez-Arco, Laura, López-López, Modesto T, Ruiz, Francisco G

  • Open Access

    Flexible Single-Layer Low-Cost Coplanar Waveguide Slot Inverted-F Antenna for Internet of Things Applications

    by Sergio Ortiz-Ruiz, Alberto Medina-Rull, Mikel G. Palomo, Mario F. Pantoja, Francisco Pasadas, Francisco G. Ruiz

    This work presents the design, fabrication, and characterization of a flexible planar inverted-F antennas (PIFA) based on coplanar waveguide (CPW) technology, operating at 2.4 GHz and intended for Internet of Things (IoT) applications. The proposed antenna features a slot-based surrounding ground conductor, enabling its use in antenna array configurations without interconnection wires. Two low-cost and low-profile fabrication alternatives are assessed: 1) robot-assisted additive manufacturing using inkjet technology with conductive silver-based ink and 2) metallization through conductive spray sputtering on laser-patterned masks. The impact of conductivity on the antenna performance metrics is examined, revealing that increasing the amount of conductive paint sputtered in prototypes fabricated by method (2) enhances the conductivity but decreases mechanical flexibility. The optimized design achieves a bandwidth of ~150 MHz and a gain of 2.9 and 2.6 dBi for antennas fabricated using methods (1) and (2), respectively. The influence of the bending angle along the $x$ - and $y$ -axes is also evaluated, demonstrating a negligible degradation in S-parameter measurements. Mechanical stress tests involving 50 and 100 bending cycles were conducted, revealing minimal deterioration. Radiation patterns are characterized using the three-antenna method in an anechoic chamber, confirming similar performance for both (1) and (2) manufacturing methods. This comprehensive study paves the way for future low-cost antennas aimed at flexible IoT applications.

  • Open Access

    Broadband Frequency Selective Surface Absorber Based on Laser-Induced Graphene for Applications From Ku-Band to Q-Band

    by Sergio Ortiz-Ruiz, Mario Pérez-Escribano, Salvador Moreno-Rodríguez, Ángel Palomares-Caballero, Juan F. Valenzuela-Valdés, Francisco G. Ruiz, Carlos Molero

    This work presents the design of a broadband frequency-selective surface absorber (FSSA) using laser-induced graphene (LIG). This type of resistive material composed of porous graphene has been analyzed, and its performance has been modeled through different cases of FSS based on LIG patches. The results of this analysis, both simulated and experimental, show the existence of periodic frequency bands of absorption ranging from a few GHz to 50 GHz. Taking advantage of this absorbing behavior, a single-layer FSSA, including a circular LIG patch at the center of the unit cell, is proposed. A circuit model for this FSSA unit cell is introduced, which allows us to efficiently improve the absorption over a large bandwidth by including an ad-hoc dielectric layer. The FSSA is fabricated and measured: the experimental results show a good agreement with the simulated ones, providing absorption of more than 0.9 from 14 GHz to 48 GHz (109.7 % relative bandwidth). In addition, the proposed design exhibits robust behavior to both TE and TM oblique incidence up to 45°.


  • Open Access

    Comprehensive analysis and exploratory design of graphene-based subharmonic mixers operating at the gigahertz band

    by M. C. Pardo, F. Pasadas, A. Medina-Rull, M. G. Palomo, S. Ortiz-Ruiz, E. G. Marin, A. Godoy, F. G. Ruiz

    Ambipolar conductance in graphene field-effect transistors (GFETs), and in particular their quasi-quadratic I–V transfer characteristic, makes these devices excellent candidates for exploiting subharmonic mixing at high frequencies. Several realizations have already demonstrated the ability of GFETs to compete with, or even improve, state-of-the-art mixers based on traditional technologies. Nonetheless, a systematic analysis of the influence on performance of both circuit design and technological aspects has not been conducted yet. In this work, we present a comprehensive assessment of the conversion losses by means of applying radio-frequency circuit design techniques in terms of filtering and matching, along with the impact stemming from physical and geometric variations of a fabricated graphene technology.


  • Open Access

    Novel methodology for detecting and localizing cancer area in histopathological images based on overlapping patches

    by Sergio Ortiz, Ignacio Rojas-Valenzuela, Fernando Rojas, Olga Valenzuela, Luis Javier Herrera, Ignacio Rojas


  • EXPERIMENTAL TEACHING IN MICROWAVE ELECTRONICS: THE USE OF A ROBOT FOR PROTOTYPING

    by Francisco Pasadas, Alberto Medina-Rull, Mikel García-Palomo, Sergio Ortiz, Mario Pantoja, Enrique G. Marin, Francisco Ruiz

  • COVID-19 Severity Classification Using a Hierarchical Classification Deep Learning Model

    by Sergio Ortiz, Juan Carlos Morales, Fernando Rojas, Olga Valenzuela, Luis Javier Herrera, Ignacio Rojas


  • Open Access

    Determination of the Severity and Percentage of COVID-19 Infection through a Hierarchical Deep Learning System

    by Sergio Ortiz, Fernando Rojas, Olga Valenzuela, Luis Javier Herrera, Ignacio Rojas

    The coronavirus disease 2019 (COVID-19) has caused millions of deaths and one of the greatest health crises of all time. In this disease, one of the most important aspects is the early detection of the infection to avoid the spread. In addition to this, it is essential to know how the disease progresses in patients, to improve patient care. This contribution presents a novel method based on a hierarchical intelligent system, that analyzes the application of deep learning models to detect and classify patients with COVID-19 using both X-ray and chest computed tomography (CT). The methodology was divided into three phases, the first being the detection of whether or not a patient suffers from COVID-19, the second step being the evaluation of the percentage of infection of this disease and the final phase is to classify the patients according to their severity. Stratification of patients suffering from COVID-19 according to their severity using automatic systems based on machine learning on medical images (especially X-ray and CT of the lungs) provides a powerful tool to help medical experts in decision making. In this article, a new contribution is made to a stratification system with three severity levels (mild, moderate and severe) using a novel histogram database (which defines how the infection is in the different CT slices for a patient suffering from COVID-19). The first two phases use CNN Densenet-161 pre-trained models, and the last uses SVM with LDA supervised learning algorithms as classification models. The initial stage detects the presence of COVID-19 through X-ray multi-class (COVID-19 vs. No-Findings vs. Pneumonia) and the results obtained for accuracy, precision, recall, and F1-score values are 88%, 91%, 87%, and 89%, respectively. The following stage manifested the percentage of COVID-19 infection in the slices of the CT-scans for a patient and the results in the metrics evaluation are 0.95 in Pearson Correlation coefficient, 5.14 in MAE and 8.47 in RMSE. The last stage finally classifies a patient in three degrees of severity as a function of global infection of the lungs and the results achieved are 95% accurate.