Paerhati Rexiti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paerhati Rexiti has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Rui Zhang
Alar Hospital of Xinjiang Production and Construction Corps, Affiliated with Sir Run Run Shaw Hospital
18 shared publicationsYixi Wang
The First Affiliated Hospital of Xinjiang Medical University
18 shared publicationsAlafate Kahaer
Evidence-Based Medicine Research Center, School of Clinical Medicine, Tsinghua University, Beijing, China
16 shared publicationsAbulikemu Maimaiti
Department of Minimally Invasive Spine Surgery and Precision Orthopedics, The First Affiliated Hospital of Xinjiang Medical University, Urumqi, China
13 shared publicationsYang Xiao
Jingzhou First People’s Hospital
13 shared publicationsDongshan Liu
The First Affiliated Hospital of Xinjiang Medical University
8 shared publications
Latest Publications
- 2 November 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (11) , 115019
Cage-orientation-dependent biomechanics of endoscopic-compatible bidirectional cortical bone trajectory-modified translaminar facet screw fixation versus bilateral percutaneous pedicle screw fixation in osteoporotic TLIF: a finite element study
- 2 November 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (11) , 115019
Cage-orientation-dependent biomechanics of endoscopic-compatible bidirectional cortical bone trajectory-modified translaminar facet screw fixation versus bilateral percutaneous pedicle screw fixation in osteoporotic TLIF: a finite element study
- Open Access
- 21 September 2026
- Published by SAGE Publications in Global Spine Journal
Response to Letter to the Editor for “Development and Validation of a Computer-Assisted Screw Trajectory Planning Model Based on Iterative Closest Point Registration and Weighted K-Nearest Neighbors Algorithms for Cortical Bone and Pedicle Screw Techniques”
- 21 September 2026
- Published by SAGE Publications in Global Spine Journal
Open AccessResponse to Letter to the Editor for “Development and Validation of a Computer-Assisted Screw Trajectory Planning Model Based on Iterative Closest Point Registration and Weighted K-Nearest Neighbors Algorithms for Cortical Bone and Pedicle Screw Techniques”
- Open Access
- 4 September 2026
- Published by SAGE Publications in Global Spine Journal
Development and Validation of a Computer-Assisted Screw Trajectory Planning Model Based on Iterative Closest Point Registration and Weighted K-Nearest Neighbors Algorithms for Cortical Bone and Pedicle Screw Techniques
Study Design: Retrospective study. Objectives: To develop and validate a computer-assisted model for planning screw trajectories to support modified cortical bone trajectory (MCBT), cortical bone trajectory (CBT), and pedicle screw (PS) techniques, based on iterative closest point (ICP) registration and weighted k-nearest neighbors (kNN) algorithms. Methods: CT data from 110 patients undergoing lumbar surgery were analyzed, comprising an internal set of 50 younger patients with normal bone density and an external set of 60 patients including younger and older individuals with or without bone loss. L4–L5 segments were reconstructed using Mimics 21.0. Two surgeons manually planned MCBT, CBT, and PS trajectories bilaterally in the internal set to serve as reference standards. A personalized computer-assisted screw planning model was developed using ICP registration and weighted kNN, where the template library consisted of manually generated screw plans. Accuracy was evaluated by comparing algorithm-generated screw trajectories against expert manually planned trajectories to calculate deviations in sagittal inclination (α), axial inclination (β), screw head, pedicle entry point, pedicle crossing point, and screw tip. Hounsfield unit (HU) values along screw trajectories were also measured. Results: In the external set (total of 720 screws: 240 PS, 240 CBT, 240 MCBT), deviations for CBT weresagittal inclination (α) 4.117 (2.028, 7.251)°, axial inclination (β) 3.714 (1.901, 6.316)°, screw head 3.382 (2.514, 4.803) mm, pedicle entry point 3.0 (1.999, 4.149) mm, pedicle crossing point 1.511 (1.008, 2.443) mm, screw tip 3.586 (2.465, 4.542) mm. Those for MCBT were 4.865 (2.126, 7.547)°, 3.801 (1.658, 6.147)°, 4.153 (3.14, 5.658) mm, 3.818 (2.43, 6.209) mm, 1.545 (1.061, 2.222) mm, 3.777 (2.768, 5.241) mm, respectively. Computational acceptance rates for PS were 97.06% (HU: 238.4±67.71) in younger normal bone group, 92.71% (173.6±53.83) in older normal bone group, and 97.37% (113.3±58.68) in older bone loss group. For CBT, rates were 100% (477.2±168.6 HU), 100% (338.5±125.8 HU), and 100% (178.1±99.75 HU), respectively. For MCBT, rates were 100% (475.8±131 HU), 98.96% (376.8±104.9 HU), and 97.37% (213.4±106 HU), respectively. MCBT and CBT achieved significantly higher HU values than PS (P < 0.05). Conclusion: The ICP registration and weighted kNN-based planning model demonstrates high computational acceptance rates and excels in planning cortical bone screw trajectories with low breach rates and high HU values.
- 4 September 2026
- Published by SAGE Publications in Global Spine Journal
Open AccessDevelopment and Validation of a Computer-Assisted Screw Trajectory Planning Model Based on Iterative Closest Point Registration and Weighted K-Nearest Neighbors Algorithms for Cortical Bone and Pedicle Screw Techniques
Study Design: Retrospective study. Objectives: To develop and validate a computer-assisted model for planning screw trajectories to support modified cortical bone trajectory (MCBT), cortical bone trajectory (CBT), and pedicle screw (PS) techniques, based on iterative closest point (ICP) registration and weighted k-nearest neighbors (kNN) algorithms. Methods: CT data from 110 patients undergoing lumbar surgery were analyzed, comprising an internal set of 50 younger patients with normal bone density and an external set of 60 patients including younger and older individuals with or without bone loss. L4–L5 segments were reconstructed using Mimics 21.0. Two surgeons manually planned MCBT, CBT, and PS trajectories bilaterally in the internal set to serve as reference standards. A personalized computer-assisted screw planning model was developed using ICP registration and weighted kNN, where the template library consisted of manually generated screw plans. Accuracy was evaluated by comparing algorithm-generated screw trajectories against expert manually planned trajectories to calculate deviations in sagittal inclination (α), axial inclination (β), screw head, pedicle entry point, pedicle crossing point, and screw tip. Hounsfield unit (HU) values along screw trajectories were also measured. Results: In the external set (total of 720 screws: 240 PS, 240 CBT, 240 MCBT), deviations for CBT weresagittal inclination (α) 4.117 (2.028, 7.251)°, axial inclination (β) 3.714 (1.901, 6.316)°, screw head 3.382 (2.514, 4.803) mm, pedicle entry point 3.0 (1.999, 4.149) mm, pedicle crossing point 1.511 (1.008, 2.443) mm, screw tip 3.586 (2.465, 4.542) mm. Those for MCBT were 4.865 (2.126, 7.547)°, 3.801 (1.658, 6.147)°, 4.153 (3.14, 5.658) mm, 3.818 (2.43, 6.209) mm, 1.545 (1.061, 2.222) mm, 3.777 (2.768, 5.241) mm, respectively. Computational acceptance rates for PS were 97.06% (HU: 238.4±67.71) in younger normal bone group, 92.71% (173.6±53.83) in older normal bone group, and 97.37% (113.3±58.68) in older bone loss group. For CBT, rates were 100% (477.2±168.6 HU), 100% (338.5±125.8 HU), and 100% (178.1±99.75 HU), respectively. For MCBT, rates were 100% (475.8±131 HU), 98.96% (376.8±104.9 HU), and 97.37% (213.4±106 HU), respectively. MCBT and CBT achieved significantly higher HU values than PS (P < 0.05). Conclusion: The ICP registration and weighted kNN-based planning model demonstrates high computational acceptance rates and excels in planning cortical bone screw trajectories with low breach rates and high HU values.
- Open Access
- 31 August 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
Biomechanical evaluation of various cage implantation angles and screw constructs in L4-5 PLIF surgery: a finite element study
Background: This study investigates the biomechanical impact of different pedicle screw constructs and cage implantation angles on the L4-L5 segment. The aim is to optimize spinal stability and mobility in Posterior Lumbar Interbody Fusion (PLIF) surgery. Methods: Three cadaveric specimens with osteoporotic bone density were used to construct finite element models of the L1-S1 segment. The L4-L5 segment underwent posterior lumbar interbody fusion (PLIF) surgery with three screw constructs: traditional pedicle screws (TT-TT), cortical bone trajectory screws (CBT-CBT), and modified cortical bone trajectory screws (MCBT-MCBT), with cage implantation angles of 30°, 45°, 60°, and 90°. Biomechanical analysis was performed under various loading conditions using ANSYS Workbench 19.1. Parameters such as range of motion, intervertebral disc stress, and pedicle screw stress were calculated to assess the effects of different fixation techniques and angles. Results: The finite element analysis validated the impact of different screw types and cage angles on L4-L5 biomechanics. At 45°, all screw types showed the highest range of motion (ROM) in most directions. CBT screws resulted in higher intervertebral disc stress, particularly at 45° and 60°. Pedicle screw stress remained stable across angles, with MCBT exhibiting higher stress in lateral bending. Rod stress increased markedly at 60° and 90° for CBT, while MCBT showed higher stress during rotation. The results highlight the biomechanical effects of screw constructs and implantation angles on spinal stability. Conclusion: CBT screws achieved the highest ROM at 45° but with elevated disc stress. MCBT screws showed lower disc stress and moderate ROM. No single construct or angle was uniformly favorable across all parameters in this finite element model.
- 31 August 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
Open AccessBiomechanical evaluation of various cage implantation angles and screw constructs in L4-5 PLIF surgery: a finite element study
Background: This study investigates the biomechanical impact of different pedicle screw constructs and cage implantation angles on the L4-L5 segment. The aim is to optimize spinal stability and mobility in Posterior Lumbar Interbody Fusion (PLIF) surgery. Methods: Three cadaveric specimens with osteoporotic bone density were used to construct finite element models of the L1-S1 segment. The L4-L5 segment underwent posterior lumbar interbody fusion (PLIF) surgery with three screw constructs: traditional pedicle screws (TT-TT), cortical bone trajectory screws (CBT-CBT), and modified cortical bone trajectory screws (MCBT-MCBT), with cage implantation angles of 30°, 45°, 60°, and 90°. Biomechanical analysis was performed under various loading conditions using ANSYS Workbench 19.1. Parameters such as range of motion, intervertebral disc stress, and pedicle screw stress were calculated to assess the effects of different fixation techniques and angles. Results: The finite element analysis validated the impact of different screw types and cage angles on L4-L5 biomechanics. At 45°, all screw types showed the highest range of motion (ROM) in most directions. CBT screws resulted in higher intervertebral disc stress, particularly at 45° and 60°. Pedicle screw stress remained stable across angles, with MCBT exhibiting higher stress in lateral bending. Rod stress increased markedly at 60° and 90° for CBT, while MCBT showed higher stress during rotation. The results highlight the biomechanical effects of screw constructs and implantation angles on spinal stability. Conclusion: CBT screws achieved the highest ROM at 45° but with elevated disc stress. MCBT screws showed lower disc stress and moderate ROM. No single construct or angle was uniformly favorable across all parameters in this finite element model.
- Open Access
- 26 August 2026
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 13, 1910920
A machine learning model for automated anesthesia risk classification in lumbar spinal stenosis patients: development and multicenter validation
Background: Patients with lumbar spinal stenosis are typically elderly with multiple comorbidities, necessitating accurate preoperative anesthetic risk assessment. The American Society of Anesthesiologists (ASA) classification quantifies functional reserve and disease burden, serving as a widely used tool for risk stratification. However, ASA classification is often influenced by subjective factors including physician experience and varies among clinicians with different seniority, while the assessment process remains time-consuming. This study aimed to develop an automated model for anesthetic risk stratification and evaluate its performance, with the goal of providing decision support for surgical and anesthetic management in this patient population. Method: Clinical data of 600 patients with lumbar spinal stenosis were collected and randomly divided into training ( n = 480) and internal validation ( n = 120) sets. An additional 100 patients from another tertiary hospital formed an external validation set. The model was validated and hyperparameter-tuned using k-fold cross-validation. Model performance, including overall classification and high-risk identification, was evaluated using accuracy, macro-average precision, macro-average recall, macro-average F1 score, weighted Kappa, linear weighted accuracy, positive predictive value, and negative predictive value. Results: In the internal validation set, the accuracy, macro-average precision, macro-average recall, macro-average F1 score, weighted Kappa coefficient and linear weighted accuracy of the model are 0.97, 0.96, 0.95, 0.96, 0.93 and 0.98 respectively, while in the external validation set, they are 0.97, 0.97, 0.94, 0.96, 0.93 and 0.99 respectively. The confusion matrix heatmap shows that the error is mainly concentrated between adjacent classes, and there is no cross-class misjudgment. In the internal validation set, the model's accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and Kappa coefficient for identifying high-risk patients were 0.98, 0.95, 0.98, 0.91, 0.99, and 0.92, respectively. In the external validation set, these values were 0.98, 0.93, 0.99, 0.93, 0.99, and 0.92, respectively. Conclusion: The machine learning model developed in this study demonstrates strong capability in stratifying anesthetic risk for patients with lumbar spinal stenosis, providing valuable reference for selecting surgical and anesthetic approaches.
- 26 August 2026
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 13, 1910920
Open AccessA machine learning model for automated anesthesia risk classification in lumbar spinal stenosis patients: development and multicenter validation
Background: Patients with lumbar spinal stenosis are typically elderly with multiple comorbidities, necessitating accurate preoperative anesthetic risk assessment. The American Society of Anesthesiologists (ASA) classification quantifies functional reserve and disease burden, serving as a widely used tool for risk stratification. However, ASA classification is often influenced by subjective factors including physician experience and varies among clinicians with different seniority, while the assessment process remains time-consuming. This study aimed to develop an automated model for anesthetic risk stratification and evaluate its performance, with the goal of providing decision support for surgical and anesthetic management in this patient population. Method: Clinical data of 600 patients with lumbar spinal stenosis were collected and randomly divided into training ( n = 480) and internal validation ( n = 120) sets. An additional 100 patients from another tertiary hospital formed an external validation set. The model was validated and hyperparameter-tuned using k-fold cross-validation. Model performance, including overall classification and high-risk identification, was evaluated using accuracy, macro-average precision, macro-average recall, macro-average F1 score, weighted Kappa, linear weighted accuracy, positive predictive value, and negative predictive value. Results: In the internal validation set, the accuracy, macro-average precision, macro-average recall, macro-average F1 score, weighted Kappa coefficient and linear weighted accuracy of the model are 0.97, 0.96, 0.95, 0.96, 0.93 and 0.98 respectively, while in the external validation set, they are 0.97, 0.97, 0.94, 0.96, 0.93 and 0.99 respectively. The confusion matrix heatmap shows that the error is mainly concentrated between adjacent classes, and there is no cross-class misjudgment. In the internal validation set, the model's accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and Kappa coefficient for identifying high-risk patients were 0.98, 0.95, 0.98, 0.91, 0.99, and 0.92, respectively. In the external validation set, these values were 0.98, 0.93, 0.99, 0.93, 0.99, and 0.92, respectively. Conclusion: The machine learning model developed in this study demonstrates strong capability in stratifying anesthetic risk for patients with lumbar spinal stenosis, providing valuable reference for selecting surgical and anesthetic approaches.
- 28 June 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 240 (7) , 663-675
Biomechanical evaluation of a fully cortical-threaded screw for modified cortical bone trajectory fixation: Combined experimental and finite element study
Although fully cortical-threaded screws are introduced as a design adaptation tailored to the cortical-dominant load path of modified cortical bone trajectory (MCBT) fixation, the biomechanical consequences of this design across the screw–bone interface and fusion construct remain insufficiently defined. Therefore, this study compared fully cortical-threaded MCBT screws with clinically used dual-threaded screws through an integrated experimental and finite element (FE) framework, spanning in vitro ovine vertebral biomechanical test and specimen-specific L4 vertebra and L1–S1 fusion models. At the screw level, compared with the control group, fully cortical-threaded MCBT screws increased maximum pull-out strength by 111.2% and multidirectional stiffness by 75%–89% in L4 vertebral FE analysis, with biomechanical testing showing corresponding increases of 39.1% in insertion torque and 41.9% in maximum pull-out strength. At the fusion-construct level, fully cortical-threaded MCBT fixation limited fused-segment motion and decreased stress across the cage, instrumentation, and vertebral bone, indicating a more coordinated load-transfer pattern rather than a simple increase in interface-level strength. These effects were consistent across fusion strategies, but procedure-specific mechanics remained evident, with PLIF producing more symmetric load sharing and TLIF retaining intrinsic asymmetry owing to unilateral facet joint resection. Overall, the fully cortical-threaded screw design for MCBT promoted continuous and stable bone–screw load transfer, translating interface-level gains into coordinated load distribution, greater fusion-construct stability, and lower deformation-driven stress concentration. These findings indicate that aligning screw architecture with the cortical-dominant load path is a mechanically rational design strategy within MCBT fixation, particularly in biomechanically demanding settings.
- 28 June 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 240 (7) , 663-675
Biomechanical evaluation of a fully cortical-threaded screw for modified cortical bone trajectory fixation: Combined experimental and finite element study
Although fully cortical-threaded screws are introduced as a design adaptation tailored to the cortical-dominant load path of modified cortical bone trajectory (MCBT) fixation, the biomechanical consequences of this design across the screw–bone interface and fusion construct remain insufficiently defined. Therefore, this study compared fully cortical-threaded MCBT screws with clinically used dual-threaded screws through an integrated experimental and finite element (FE) framework, spanning in vitro ovine vertebral biomechanical test and specimen-specific L4 vertebra and L1–S1 fusion models. At the screw level, compared with the control group, fully cortical-threaded MCBT screws increased maximum pull-out strength by 111.2% and multidirectional stiffness by 75%–89% in L4 vertebral FE analysis, with biomechanical testing showing corresponding increases of 39.1% in insertion torque and 41.9% in maximum pull-out strength. At the fusion-construct level, fully cortical-threaded MCBT fixation limited fused-segment motion and decreased stress across the cage, instrumentation, and vertebral bone, indicating a more coordinated load-transfer pattern rather than a simple increase in interface-level strength. These effects were consistent across fusion strategies, but procedure-specific mechanics remained evident, with PLIF producing more symmetric load sharing and TLIF retaining intrinsic asymmetry owing to unilateral facet joint resection. Overall, the fully cortical-threaded screw design for MCBT promoted continuous and stable bone–screw load transfer, translating interface-level gains into coordinated load distribution, greater fusion-construct stability, and lower deformation-driven stress concentration. These findings indicate that aligning screw architecture with the cortical-dominant load path is a mechanically rational design strategy within MCBT fixation, particularly in biomechanically demanding settings.
- 23 March 2026
- Published by Springer Nature in Journal of Bone and Mineral Metabolism
- Vol. 44 (4) , 1-13
Identification of potential diagnostic and therapeutic apoptosis-related casual targets for osteoporosis: an integrated multi-omics analysis
Introduction Apoptosis plays a significant role in osteoporosis (OP), yet a causal relationship between apoptosis gene expressions and OP remains unexplored. This study applies an integrated multi-omics analysis to establish causality between them, offering clinical treatment and prediction insights. Materials and methods Apoptosis-related genes are sourced from GeneCards, and 6 transcriptomic datasets from the cells in the circulation are obtained from GEO. Meta-analysis integrated differentially expressed apoptosis-related genes (DEGs) from the above 6 datasets. Causality between gene expressions, epigenetic changes, and OP is examined using OP genome-wide association study (GWAS), plasma expression quantitative trait loci (eQTL), and methylation quantitative trait loci (mQTL) data, while analysis of skeletal muscle eQTL and OP GWAS data is conducted. External validation is performed with the UK Biobank datasets. Results Meta-analysis of 6 GEO datasets identified 384 DEGs, including 78 apoptosis-related genes. The three-step analysis indicates 8 candidate causal genes in blood, including MAP3K3, DPP8, RPL3, PPP2CA, CD86, LRRFIP1, TRAP1, and DUSP6, with LRRFIP1 influenced by four methylation sites. Analysis of skeletal muscle data reveals 4 causal genes, including SIPA1L3, PDLIM7, CTNNB1, and DPP8. Among apoptosis-related genes causally linked to OP in both circulation and skeletal muscle, LRRFIP1 was validated based on methylation-associated regulation and demonstrated consistent, reproducible expression patterns. Conclusions This study uses a multi-omics strategy to clarify the roles of apoptosis-related gene expressions and their corresponding methylation in OP, providing targets and a basis for early diagnosis, personalized treatment, and monitoring of OP.
- 23 March 2026
- Published by Springer Nature in Journal of Bone and Mineral Metabolism
- Vol. 44 (4) , 1-13
Identification of potential diagnostic and therapeutic apoptosis-related casual targets for osteoporosis: an integrated multi-omics analysis
Introduction Apoptosis plays a significant role in osteoporosis (OP), yet a causal relationship between apoptosis gene expressions and OP remains unexplored. This study applies an integrated multi-omics analysis to establish causality between them, offering clinical treatment and prediction insights. Materials and methods Apoptosis-related genes are sourced from GeneCards, and 6 transcriptomic datasets from the cells in the circulation are obtained from GEO. Meta-analysis integrated differentially expressed apoptosis-related genes (DEGs) from the above 6 datasets. Causality between gene expressions, epigenetic changes, and OP is examined using OP genome-wide association study (GWAS), plasma expression quantitative trait loci (eQTL), and methylation quantitative trait loci (mQTL) data, while analysis of skeletal muscle eQTL and OP GWAS data is conducted. External validation is performed with the UK Biobank datasets. Results Meta-analysis of 6 GEO datasets identified 384 DEGs, including 78 apoptosis-related genes. The three-step analysis indicates 8 candidate causal genes in blood, including MAP3K3, DPP8, RPL3, PPP2CA, CD86, LRRFIP1, TRAP1, and DUSP6, with LRRFIP1 influenced by four methylation sites. Analysis of skeletal muscle data reveals 4 causal genes, including SIPA1L3, PDLIM7, CTNNB1, and DPP8. Among apoptosis-related genes causally linked to OP in both circulation and skeletal muscle, LRRFIP1 was validated based on methylation-associated regulation and demonstrated consistent, reproducible expression patterns. Conclusions This study uses a multi-omics strategy to clarify the roles of apoptosis-related gene expressions and their corresponding methylation in OP, providing targets and a basis for early diagnosis, personalized treatment, and monitoring of OP.
- Open Access
- 1 February 2026
- Published by SAGE Publications in Digital Health
- Vol. 12
Clinical-radiographic machine learning for predicting surgical technique and approaches for lumbar spinal stenosis: Model development and multicenter validation
Objective: This study aims to develop a machine learning model for predicting surgical techniques and approaches for lumbar spinal stenosis (LSS) based on clinical and radiological data. Methods: 600 LSS patients from our hospital were randomly split 8:2 into training and internal validation sets, and 100 patients from another tertiary hospital during the same period were included as the external validation set. The model incorporated clinical and radiological parameters, including coronal/sagittal balance, lumbar stability, and others. Model performance was evaluated using accuracy, precision, recall, specificity, Kappa, and macro-average F1 score. Confusion matrices, ROC, PR, DCA, and calibration curves were generated to assess model performance. Results: The model achieved accuracies of 0.93/0.91 (Kappa: 0.86/0.85) for overall prediction, 0.98 (Kappa: 0.92/0.95) for fusion versus decompression, 0.86 (Kappa: 0.71; macro-F1: 0.86) for fusion approach, and 0.97/0.95 (Kappa: 0.90/0.86; macro-F1: 0.95/0.93) for decompression approach. In the validation sets, the model achieved area under curve values ranging from 0.993 to 0.997 in the internal validation set and 0.985 to 0.991 in the external validation set. DCA showed positive net benefit across a range of threshold probabilities in both validation sets. PR curves yielded average precision values of 0.99, 0.94, and 0.97 in the internal set and 0.98, 0.91, and 0.94 in the external set, respectively. Calibration analysis for the fusion versus decompression task showed Brier scores of 0.07 in the internal and external validation sets. Conclusions: The clinical and radiological machine learning model developed in this study demonstrates promising predictive performance for surgical decision prediction in LSS, with consistent results across internal and external validation sets. However, its clinical utility requires prospective validation, and the model should currently be regarded as an exploratory reference tool rather than a standalone clinical decision-maker.
- 1 February 2026
- Published by SAGE Publications in Digital Health
- Vol. 12
Open AccessClinical-radiographic machine learning for predicting surgical technique and approaches for lumbar spinal stenosis: Model development and multicenter validation
Objective: This study aims to develop a machine learning model for predicting surgical techniques and approaches for lumbar spinal stenosis (LSS) based on clinical and radiological data. Methods: 600 LSS patients from our hospital were randomly split 8:2 into training and internal validation sets, and 100 patients from another tertiary hospital during the same period were included as the external validation set. The model incorporated clinical and radiological parameters, including coronal/sagittal balance, lumbar stability, and others. Model performance was evaluated using accuracy, precision, recall, specificity, Kappa, and macro-average F1 score. Confusion matrices, ROC, PR, DCA, and calibration curves were generated to assess model performance. Results: The model achieved accuracies of 0.93/0.91 (Kappa: 0.86/0.85) for overall prediction, 0.98 (Kappa: 0.92/0.95) for fusion versus decompression, 0.86 (Kappa: 0.71; macro-F1: 0.86) for fusion approach, and 0.97/0.95 (Kappa: 0.90/0.86; macro-F1: 0.95/0.93) for decompression approach. In the validation sets, the model achieved area under curve values ranging from 0.993 to 0.997 in the internal validation set and 0.985 to 0.991 in the external validation set. DCA showed positive net benefit across a range of threshold probabilities in both validation sets. PR curves yielded average precision values of 0.99, 0.94, and 0.97 in the internal set and 0.98, 0.91, and 0.94 in the external set, respectively. Calibration analysis for the fusion versus decompression task showed Brier scores of 0.07 in the internal and external validation sets. Conclusions: The clinical and radiological machine learning model developed in this study demonstrates promising predictive performance for surgical decision prediction in LSS, with consistent results across internal and external validation sets. However, its clinical utility requires prospective validation, and the model should currently be regarded as an exploratory reference tool rather than a standalone clinical decision-maker.
- Open Access
- 22 December 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 1101
Study on anatomical parameters of modified cortical bone trajectories in the lower lumbar vertebrae
Modified Cortical Bone Trajectory (MCBT) technology offers advantages over Cortical Bone Trajectory (CBT) technology in anatomy, biomechanics, and therapeu
- 22 December 2025
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 26 (1) , 1101
Open AccessStudy on anatomical parameters of modified cortical bone trajectories in the lower lumbar vertebrae
Modified Cortical Bone Trajectory (MCBT) technology offers advantages over Cortical Bone Trajectory (CBT) technology in anatomy, biomechanics, and therapeu