TCTing-Yu Chen

Ting-Yu Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ting-Yu Chen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating the Impact of Vertical Green Systems on Building Temperature Regulation: Effects of Shading Density and Proximity

    by Ting-Yu Chen, Wen-Pei Sung, Che-Lun Lee

    Urban heat islands and increasing energy consumption in subtropical regions such as Taiwan present substantial challenges, particularly in densely populated areas where traditional green spaces are limited. To address these issues, vertical green systems (VGSs) have emerged as a sustainable solution to improve building energy efficiency and mitigate urban heat. This study investigates the impact of VGSs on building temperature regulation, specifically focusing on the effects of shading density and the distance from the building facade. Two experimental setups were assessed, with VGSs positioned at distances of 50 cm and 100 cm, and shading densities of 70% and 95%. Experiments conducted between May and September 2022, under full sunlight (average temperature of 33 °C), revealed that a VGS with a 95% shading density significantly reduced solar radiation to below 50 W/m2. Additionally, it lowered interior temperatures by 0.5–2.1 °C and decreased surface temperatures by 5–12 °C when positioned 100 cm from the building. The VGS also enhanced temperature stability, maintaining interior temperature fluctuations within 1 °C compared to 4 °C in the control group. These results demonstrate that higher shading densities and increased distances from the building facade optimize temperature control and energy efficiency. The findings offer valuable insights for sustainable urban building design, suggesting that VGSs with greater shading densities and appropriate distances provide significant benefits in reducing solar radiation, surface temperatures, and interior temperature fluctuations.


  • Open Access

    A Study on the Causal Relationships Between Blood Protein Ratios and Hepatobiliary Cancers Based on Mendelian Randomization Models

    by Zikang Jiang, Jinghui Sung, Yixin Zhuang, Wenzheng Fang, Ting-Yu Chen, Yuanpeng Huang

  • Open Access

    Developing an Analytical Model to Assess the Impact of PM2.5 Levels in Parks on Peripheral Artery Disease and Respiratory Conditions

    by Jinghui Sung, Yuanpeng Huang, Ting-Yu Chen

    This study aims to investigate the impact of changes in PM2.5 concentrations on peripheral artery disease (PAD) and respiratory diseases, considering the severe threats to health posed by urbanization and air pollution since the Industrial Revolution. Utilizing a mathematical model, the research analyzes health data collected from the northeastern United States and experimental data collected from metropolitan parks in southern China. The study gathers data on air quality changes and verifies the accuracy of the model through statistical methods to explore the impact on health risks. The results indicate that for every 10 µg/m³ increase in PM2.5 concentration, the number of hospital admissions for PAD patients increases by 0.26%, and emergency visits for respiratory diseases increase by 0.23%, primarily due to acute exacerbations of COPD. These findings not only highlight the negative impact of air pollution on health but also provide a critical basis for relevant departments to formulate response measures to protect public health, particularly for cardiovascular disease patients.

  • Open Access

    Using the Groundwater Cooling System and Phenolic Aldehyde Isolation Layer on Building Walls to Evaluation of Heat Effect

    by Ting-Yu Chen, Wen-Pei Sung

    This study examines the thermal performance of building walls under full sunlight conditions using various insulation strategies. Specifically, it evaluates: (1) the effects of heat on building walls and indoor spaces; (2) the impact of groundwater cooling systems on thermal environments; (3) the influence of phenolic aldehyde insulation layers on heat transfer; and (4) the combined effects of groundwater cooling and phenolic aldehyde thermal insulation. Fluent–CFD (Computational Fluid Dynamics) was used in the study to simulate temperature transmission between the sun, the groundwater cooling system, and both indoor and outdoor spaces. Experimental analysis and simulations reveal that both the phenolic aldehyde insulation layer and the groundwater cooling system effectively reduce heat transfer, with the groundwater cooling system demonstrating the most significant impact. The phenolic aldehyde layer decreases the temperature difference between inner and outer walls by approximately 8 °C. The groundwater cooling system further reduces both inner and outer wall temperatures, helping to maintain cooler indoor environments. Simulation results indicate that, while the phenolic aldehyde layer effectively prevents external heat from penetrating into the room, it does not eliminate heat accumulation. In contrast, the groundwater cooling system efficiently dissipates heat, mitigating this issue. Groundwater analysis shows that maximum temperature differences occur at specific times of the day, with water flow effectively cooling the space. The combined use of the phenolic aldehyde insulation layer and the groundwater cooling system offers superior thermal performance. The phenolic layer provides effective heat blocking, while the groundwater system facilitates heat dissipation, optimizing indoor temperature and reducing air conditioning loads. This combination enhances overall comfort and energy efficiency, with the groundwater cooling system benefiting from reduced flow velocity and lower energy consumption.

  • Open Access

    Influence of landscape elements in the park on thermal environment – using a metropolitan park in Taichung city as an example

    by Wen-Pei Sung, Ming-Hsiang Shih, Ting-Yu Chen, Chun-Hao Liu

    Population growth and rapid urban development have led to urbanization, caused environmental problems such as: heat islands and air pollution. The installation of park green space system is widely regarded as effective in alleviating the thermal environment and improving the surrounding air quality. Therefore, this study focuses on parks in highly developed cities, The measurements of terrain and topography were conducted using unmanned aerial vehicles (UAVs) to establish a terrain model. This model was combined with environmental factors such as wind speed, direction, solar radiation, temperature, and soil infiltration were measured to assess the correlation between different landscape elements and the environment in various parks. In addition, an air particulate monitor (Arduino Uno) was developed to measure the contribution of green space systems to urban air pollution. Furthermore, by integrating measurements of multiple factors and employing the Pearson's correlation method and three-dimensional scatter plots, this study explored the relationships between many variables of park. Test results show that 1. The materials of the landscape elements should have moderate thermal conductivity; 2. The moisture content of the soil of grassland should be monitored; 3. To improve the air quality, the correlation between wind speed and wind direction should be considered in the placement of landscape elements.


  • Open Access

    Strategy for Improving the Indoor Environment of Office Spaces in Subtropical Cities

    by Wen-Pei Sung, Ting-Yu Chen, Chun-Hao Liu

    Taiwan is located in a subtropical region with high temperatures and humidity. Office spaces are located in air-enclosed rooms in buildings, where doors and windows remain closed and only a central air-conditioning system provides temperature adjustment and ventilation. Most offices in this area have office seating areas, document storage areas on both sides of the office, and multi-function devices, which can cause sick office syndrome in the employees. This study applied environmental monitoring technology to analyze the architectural form and indoor and outdoor air quality to propose improvement strategies addressing indoor temperature, relative humidity and air quality. Quality indices were used created to evaluate the improvement efficiency. The analysis results showed that the indoor temperature and relative humidity in staff seating areas can be effectively improved. The statistical analysis results of improved efficiency for PM2.5, PM10 concentrations and total suspended particulates showed that the average indicator values have been raised from 0.05 to 1.5, 2.45 to 4.02 and 0.91 to 3.54, respectively, for staff seating area and −0.01 to 2.82, 0.15 to 3.91 and 1.25 to 7.25, respectively, for photocopier areas. The ambient air quality of this office space has been significantly improved. This study can serve as an example of air quality improvement in traditional common office spaces.