Qihong Ning
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qihong Ning has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Daxiang Cui
Medical and Engineering Cross Research Institute, The First Affiliated Hospital of Henan University, Kaifeng, China
2 shared publications - Kan Wang
School of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Wei Zheng
School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Yuemeng Cheng
School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Armando Zhu
Department of Electrical and Computer Engineering, Carnegie Mellon University, Pittsburgh, PA 15213, USA
1 shared publication - Chujun Zheng
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai Engineering Research Center for Intelligent Diagnosis and treatment instrument, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai 200240, China
1 shared publication
Latest Publications
- 30 March 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (13) , 3959-3970
Rapid segmentation and sensitive analysis of CRP with paper-based microfluidic device using machine learning
Microfluidic paper-based analytical devices (μPADs) have been widely used in point-of-care testing owing to their simple operation, low volume of the sample required, and the lack of the need for an external force. To obtain accurate semi-quantitative or quantitative results, μPADs need to respond to the challenges posed by differences in reaction conditions. In this paper, multi-layer μPADs are fabricated by the imprinting method for the colorimetric detection of C-reactive protein (CRP). Different lighting conditions and shooting angles of scenes are simulated in image acquisition, and the detection-related performance of μPADs is improved by using a machine learning algorithm. The You Only Look Once (YOLO) model is used to identify the areas of reaction in μPADs. This model can observe an image only once to predict the objects present in it and their locations. The YOLO model trained in this study was able to identify all the reaction areas quickly without incurring any error. These reaction areas were categorized by classification algorithms to determine the risk level of CRP concentration. Multi-layer perceptron, convolutional neural network, and residual network algorithms were used for the classification tasks, where the latter yielded the highest accuracy of 96%. It has a promising application prospect in fast recognition and analysis of μPADs. Graphical abstract
- 30 March 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (13) , 3959-3970
Rapid segmentation and sensitive analysis of CRP with paper-based microfluidic device using machine learning
Microfluidic paper-based analytical devices (μPADs) have been widely used in point-of-care testing owing to their simple operation, low volume of the sample required, and the lack of the need for an external force. To obtain accurate semi-quantitative or quantitative results, μPADs need to respond to the challenges posed by differences in reaction conditions. In this paper, multi-layer μPADs are fabricated by the imprinting method for the colorimetric detection of C-reactive protein (CRP). Different lighting conditions and shooting angles of scenes are simulated in image acquisition, and the detection-related performance of μPADs is improved by using a machine learning algorithm. The You Only Look Once (YOLO) model is used to identify the areas of reaction in μPADs. This model can observe an image only once to predict the objects present in it and their locations. The YOLO model trained in this study was able to identify all the reaction areas quickly without incurring any error. These reaction areas were categorized by classification algorithms to determine the risk level of CRP concentration. Multi-layer perceptron, convolutional neural network, and residual network algorithms were used for the classification tasks, where the latter yielded the highest accuracy of 96%. It has a promising application prospect in fast recognition and analysis of μPADs. Graphical abstract
- 16 March 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (8) , 1678-1687
Nanozyme enhanced magnetic immunoassay for dual-mode detection of gastrin-17
In this study, we developed a novel magnetic lateral flow assay based on iron oxide decorated with platinum probes (Fe3O4@Pt) for dual-mode detection of gastrin-17 (G-17), which is one of the main biomarkers for early gastric cancer diagnosis. The probe material exhibits both magnetic properties and peroxidase activity. The peroxidase activity enhances the intensity of the brownish coloring of the Fe3O4@Pt probes on the test strip, with a limit of detection of 10 pg mL−1 using the naked eye, which is remarkable for colorimetric lateral flow assays. The magnetic property allows the simple separation and enrichment of the sample, and the signal can be read using a magnetic assay reader for quantitative detection. The linear range for G-17 using the magnetic signal was determined as 10 pg mL−1 to 2200 pg mL−1, and the calculated limit of detection was as low as 3.365 pg mL−1, thereby covering the reference range for G-17. Serum samples were used to validate the test strip, which exhibited high sensitivity, high specificity, and consistency with the results obtained by the enzyme-linked immunosorbent assay method. The entire inspection process using this method can produce results within 35 min and it is simple to operate without requiring strict experimental conditions. This dual-mode lateral flow test strip provides a simple, rapid, and quantitative strategy for detecting G-17, and it may also be valuable in other portable diagnostic applications.
- 16 March 2022
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 147 (8) , 1678-1687
Nanozyme enhanced magnetic immunoassay for dual-mode detection of gastrin-17
In this study, we developed a novel magnetic lateral flow assay based on iron oxide decorated with platinum probes (Fe3O4@Pt) for dual-mode detection of gastrin-17 (G-17), which is one of the main biomarkers for early gastric cancer diagnosis. The probe material exhibits both magnetic properties and peroxidase activity. The peroxidase activity enhances the intensity of the brownish coloring of the Fe3O4@Pt probes on the test strip, with a limit of detection of 10 pg mL−1 using the naked eye, which is remarkable for colorimetric lateral flow assays. The magnetic property allows the simple separation and enrichment of the sample, and the signal can be read using a magnetic assay reader for quantitative detection. The linear range for G-17 using the magnetic signal was determined as 10 pg mL−1 to 2200 pg mL−1, and the calculated limit of detection was as low as 3.365 pg mL−1, thereby covering the reference range for G-17. Serum samples were used to validate the test strip, which exhibited high sensitivity, high specificity, and consistency with the results obtained by the enzyme-linked immunosorbent assay method. The entire inspection process using this method can produce results within 35 min and it is simple to operate without requiring strict experimental conditions. This dual-mode lateral flow test strip provides a simple, rapid, and quantitative strategy for detecting G-17, and it may also be valuable in other portable diagnostic applications.