Zheng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zheng Zhang has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Linda Yang
College of Mechanical and Aerospace Engineering, Jilin University, Changchun 130022, China
1 shared publication - Xin Wang
Jilin University
1 shared publication
Latest Publications
- Open Access
- 30 March 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (4) , 552
A Microfluidic PET-Based Electrochemical Glucose Sensor
Paper-based microfluidic sensors have gained increased attention in the field of analytical assays in recent years due to their self-driven nature, ease of preparation, high integration, low reagent consumption, and low cost. However, paper-based microfluidic sensors still have many deficiencies when it comes to the detection of some specific detectors such as blood glucose. For example, the processing procedure for microfluidic channels is tedious, the sensor electrodes are easily damaged by bending, and they can only be used as disposable products. To solve the above problems, a PET-based microfluidic sensor was proposed in this paper, the performance of which was tested with glucose as the target detector. The experimental results showed that the analytical performance of this sensor is comparable to that of existing commercial glucose meters. This work provides implications for the substrate selection of microfluidic chips for some biochemical analyses.
- 30 March 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (4) , 552
Open AccessA Microfluidic PET-Based Electrochemical Glucose Sensor
Paper-based microfluidic sensors have gained increased attention in the field of analytical assays in recent years due to their self-driven nature, ease of preparation, high integration, low reagent consumption, and low cost. However, paper-based microfluidic sensors still have many deficiencies when it comes to the detection of some specific detectors such as blood glucose. For example, the processing procedure for microfluidic channels is tedious, the sensor electrodes are easily damaged by bending, and they can only be used as disposable products. To solve the above problems, a PET-based microfluidic sensor was proposed in this paper, the performance of which was tested with glucose as the target detector. The experimental results showed that the analytical performance of this sensor is comparable to that of existing commercial glucose meters. This work provides implications for the substrate selection of microfluidic chips for some biochemical analyses.