Tsugumi Takayama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tsugumi Takayama has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Akira Shionoya
Information and Management Systems Engineering, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka 940-2188, Niigata, Japan
1 shared publication - Hirofumi Nonaka
Nagaoka University of Technology Nagaoka Japan
1 shared publication - Hisashi Uchiyama
Information and Management Systems Engineering, Nagaoka University of Technology, 1603-1 Kamitomioka, Nagaoka 940-2188, Niigata, Japan
1 shared publication - Kouji Hayami
Data Dock Ltd., Nagaoka-shi 940-1140, Japan
1 shared publication - Mai Kobayashi
Department of Physical Threrapy, Seiryou, Junior College of Rehabilitation, Nagaoka-shi 940-2138, Japan
1 shared publication - Masahito Nagamori
Integrated Bioscience and Technology Major, Graduate Schools of Engineering, Nagaoka University of Technology, Nagaoka-shi 940-2188, Japan
1 shared publication
Latest Publications
- Open Access
Exploration of an Inflection Point of Ventilation Parameters with Anaerobic Threshold Using Strucchange
(1) Background: When measuring anaerobic work threshold (AT), the conventional V-slope method includes the subjectivity of the examiner, which cannot be eliminated completely. Therefore, we implemented an engineering method using strucchange to objectively search for the inflection point of AT. (2) Methods: Seventeen subjects (15 men and 2 women) were included in the study. The subjects rode an ergometer and performed a ramp load test for 18 min and 30 s. (3) Results: In VE (Ventilation), 11 out of 12 subjects had the same results with 95% confidence intervals for the AT by the strucchange and respiratory metabolic apparatus. In VCO2 (Carbon dioxide emissions), 9 out of 12 subjects had the same results with 95% confidence intervals for the AT with the strucchange and respiratory metabolic apparatus. In VE, 3 out of 12 subjects showed the same results for respiratory metabolic analysis and the AT by the V-slope method. In VCO2, 3 out of 12 subjects showed the same results for the respiratory metabolic analysis and AT by the V-slope method in VCO2. (4) Conclusions: Strucchange was more objective and significant in identifying the AT than the V-slope method.
Open AccessExploration of an Inflection Point of Ventilation Parameters with Anaerobic Threshold Using Strucchange
(1) Background: When measuring anaerobic work threshold (AT), the conventional V-slope method includes the subjectivity of the examiner, which cannot be eliminated completely. Therefore, we implemented an engineering method using strucchange to objectively search for the inflection point of AT. (2) Methods: Seventeen subjects (15 men and 2 women) were included in the study. The subjects rode an ergometer and performed a ramp load test for 18 min and 30 s. (3) Results: In VE (Ventilation), 11 out of 12 subjects had the same results with 95% confidence intervals for the AT by the strucchange and respiratory metabolic apparatus. In VCO2 (Carbon dioxide emissions), 9 out of 12 subjects had the same results with 95% confidence intervals for the AT with the strucchange and respiratory metabolic apparatus. In VE, 3 out of 12 subjects showed the same results for respiratory metabolic analysis and the AT by the V-slope method. In VCO2, 3 out of 12 subjects showed the same results for the respiratory metabolic analysis and AT by the V-slope method in VCO2. (4) Conclusions: Strucchange was more objective and significant in identifying the AT than the V-slope method.