Jooik Jeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jooik Jeon has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Jung Keun Hyun
College of Medicine Ajou University Suwon South Korea
6 shared publications - Kyung-Sub Kim
Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea
4 shared publications - Seung-Kyun Kang
Seoul National University
4 shared publications - Jae-Hwan Lee
Department of Materials Science and Engineering Seoul National University Seoul Republic of Korea
3 shared publications - Jeonghyun Kim
Department of Electronic Convergence Engineering, Kwangwoon University, Seoul 01897, Republic of Korea
3 shared publications - Minseong Chae
Department of Materials Science and Engineering Seoul National University Seoul Republic of Korea
3 shared publications
Latest Publications
- Open Access
- 15 September 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (86) , e78432
Materials and Design Strategies of Fully 3D Printed Biodegradable Wireless Devices for Biomedical Applications
3D printing of bioelectronics offers a versatile platform for fabricating personalized and structurally integrated electronic systems within biological scaffolds. Biodegradable electronics, which naturally dissolve after their functional lifetime, minimize the long‐term burden on both patients and healthcare providers by eliminating the need for surgical retrieval. In this study, we developed a library of 3D‐printable, biodegradable electronic inks encompassing conductors, semiconductors, and dielectrics, thereby enabling the direct printing of fully functional, multi‐material, customizable electronic systems in a single integrated process. Especially, conjugated molecules were introduced to improve charge mobility and energy level alignment in semiconducting inks. This ink platform supports the fabrication of passive and active components and physical and chemical sensors, making it suitable for complex biomedical applications. Versatility of this system was demonstrated through two representative applications: (i) wireless pressure sensor embedded within biodegradable scaffolds, (ii) wireless electrical stimulators that retain programmable electrical functionality in vivo and degrade post‐implantation. This work establishes a foundation of modules for autonomous, biodegradable bioelectronic systems fabricated entirely via 3D printing, with implications for personalized diagnostics, therapeutic interfaces, and transient medical devices.
- 15 September 2026
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (86) , e78432
Open AccessMaterials and Design Strategies of Fully 3D Printed Biodegradable Wireless Devices for Biomedical Applications
3D printing of bioelectronics offers a versatile platform for fabricating personalized and structurally integrated electronic systems within biological scaffolds. Biodegradable electronics, which naturally dissolve after their functional lifetime, minimize the long‐term burden on both patients and healthcare providers by eliminating the need for surgical retrieval. In this study, we developed a library of 3D‐printable, biodegradable electronic inks encompassing conductors, semiconductors, and dielectrics, thereby enabling the direct printing of fully functional, multi‐material, customizable electronic systems in a single integrated process. Especially, conjugated molecules were introduced to improve charge mobility and energy level alignment in semiconducting inks. This ink platform supports the fabrication of passive and active components and physical and chemical sensors, making it suitable for complex biomedical applications. Versatility of this system was demonstrated through two representative applications: (i) wireless pressure sensor embedded within biodegradable scaffolds, (ii) wireless electrical stimulators that retain programmable electrical functionality in vivo and degrade post‐implantation. This work establishes a foundation of modules for autonomous, biodegradable bioelectronic systems fabricated entirely via 3D printing, with implications for personalized diagnostics, therapeutic interfaces, and transient medical devices.
- 5 March 2026
- Published by Springer Nature in Nature Sustainability
- Vol. 9 (5) , 692-705
Biodegradable yet hyperdurable robotic fingers for zero-waste soft electronics
- 5 March 2026
- Published by Springer Nature in Nature Sustainability
- Vol. 9 (5) , 692-705
Biodegradable yet hyperdurable robotic fingers for zero-waste soft electronics
- Top Cited PapersOpen Access
- 20 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (51) , eads9258
Hypersensitive meta-crack strain sensor for real-time biomedical monitoring
Real-time monitoring of infinitesimal deformations on complex morphologies is essential for precision biomechanical engineering. While flexible strain sensors facilitate real-time monitoring with shape-adaptive properties, their sensitivity is generally lower than spectroscopic imaging methods. Crack-based strain sensors achieve enhanced sensitivity with gauge factors (GFs) exceeding 30,000; however, such GFs are only attainable at large strains exceeding several percent and decline below 10 for strains under 10 −3 , rendering them inadequate for minute deformations. Here, we introduce hypersensitive and flexible “meta-crack” sensors detecting infinitesimal strains through previously undiscovered crack-opening mechanisms. These sensors achieve remarkable GFs surpassing 1000 at strains of 10 −4 on substrates with a Poisson’s ratio of −0.9. The crack orientation–independent gap-widening behavior elucidates the origin of hypersensitivity, corroborated by simplified models and finite element analysis. Additionally, parallel mechanical circuits of meta-cracks effectively address the trade-off between resolution and maximum sensing threshold. In vivo real-time monitoring of cerebrovascular dynamics with a strain resolution of 10 −5 underscores the hypersensitivity and conformal adaptability of sensors.
- 20 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (51) , eads9258
Top Cited PapersOpen AccessHypersensitive meta-crack strain sensor for real-time biomedical monitoring
Real-time monitoring of infinitesimal deformations on complex morphologies is essential for precision biomechanical engineering. While flexible strain sensors facilitate real-time monitoring with shape-adaptive properties, their sensitivity is generally lower than spectroscopic imaging methods. Crack-based strain sensors achieve enhanced sensitivity with gauge factors (GFs) exceeding 30,000; however, such GFs are only attainable at large strains exceeding several percent and decline below 10 for strains under 10 −3 , rendering them inadequate for minute deformations. Here, we introduce hypersensitive and flexible “meta-crack” sensors detecting infinitesimal strains through previously undiscovered crack-opening mechanisms. These sensors achieve remarkable GFs surpassing 1000 at strains of 10 −4 on substrates with a Poisson’s ratio of −0.9. The crack orientation–independent gap-widening behavior elucidates the origin of hypersensitivity, corroborated by simplified models and finite element analysis. Additionally, parallel mechanical circuits of meta-cracks effectively address the trade-off between resolution and maximum sensing threshold. In vivo real-time monitoring of cerebrovascular dynamics with a strain resolution of 10 −5 underscores the hypersensitivity and conformal adaptability of sensors.
- Top Cited Papers
- 5 August 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (9) , 815-828
A biodegradable and self-deployable electronic tent electrode for brain cortex interfacing
- 5 August 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (9) , 815-828
Top Cited PapersA biodegradable and self-deployable electronic tent electrode for brain cortex interfacing
- Open Access
- 12 June 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 183, 50-60
Association between neural stem/progenitor cells and biomaterials in spinal cord injury therapies: A systematic review and network meta-analysis
- 12 June 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 183, 50-60
Open AccessAssociation between neural stem/progenitor cells and biomaterials in spinal cord injury therapies: A systematic review and network meta-analysis
- Open Access
- 1 January 2022
- Published by SAGE Publications in Journal of Tissue Engineering
- Vol. 13
Self-assembling peptide gels promote angiogenesis and functional recovery after spinal cord injury in rats
Spinal cord injury (SCI) leads to disruption of the blood–spinal cord barrier, hemorrhage, and tissue edema, which impair blood circulation and induce ischemia. Angiogenesis after SCI is an important step in the repair of damaged tissues, and the extent of angiogenesis strongly correlates with the neural regeneration. Various biomaterials have been developed to promote angiogenesis signaling pathways, and angiogenic self-assembling peptides are useful for producing diverse supramolecular structures with tunable functionality. RADA16 (Ac-RARADADARARADADA-NH2), which forms nanofiber networks under physiological conditions, is a self-assembling peptide that can provide mechanical support for tissue regeneration and reportedly has diverse roles in wound healing. In this study, we applied an injectable form of RADA16 with or without the neuropeptide substance P to the contused spinal cords of rats and examined angiogenesis within the damaged spinal cord and subsequent functional improvement. Histological and immunohistochemical analyses revealed that the inflammatory cell population in the lesion cavity was decreased, the vessel number and density around the damaged spinal cord were increased, and the levels of neurofilaments within the lesion cavity were increased in SCI rats that received RADA16 and RADA16 with substance P (rats in the RADA16/SP group). Moreover, real-time PCR analysis of damaged spinal cord tissues showed that IL-10 expression was increased and that locomotor function (as assessed by the Basso, Beattie, and Bresnahan (BBB) scale and the horizontal ladder test) was significantly improved in the RADA16/SP group compared to the control group. Our findings indicate that RADA16 modified with substance P effectively stimulates angiogenesis within the damaged spinal cord and is a candidate agent for promoting functional recovery post-SCI.
- 1 January 2022
- Published by SAGE Publications in Journal of Tissue Engineering
- Vol. 13
Open AccessSelf-assembling peptide gels promote angiogenesis and functional recovery after spinal cord injury in rats
Spinal cord injury (SCI) leads to disruption of the blood–spinal cord barrier, hemorrhage, and tissue edema, which impair blood circulation and induce ischemia. Angiogenesis after SCI is an important step in the repair of damaged tissues, and the extent of angiogenesis strongly correlates with the neural regeneration. Various biomaterials have been developed to promote angiogenesis signaling pathways, and angiogenic self-assembling peptides are useful for producing diverse supramolecular structures with tunable functionality. RADA16 (Ac-RARADADARARADADA-NH2), which forms nanofiber networks under physiological conditions, is a self-assembling peptide that can provide mechanical support for tissue regeneration and reportedly has diverse roles in wound healing. In this study, we applied an injectable form of RADA16 with or without the neuropeptide substance P to the contused spinal cords of rats and examined angiogenesis within the damaged spinal cord and subsequent functional improvement. Histological and immunohistochemical analyses revealed that the inflammatory cell population in the lesion cavity was decreased, the vessel number and density around the damaged spinal cord were increased, and the levels of neurofilaments within the lesion cavity were increased in SCI rats that received RADA16 and RADA16 with substance P (rats in the RADA16/SP group). Moreover, real-time PCR analysis of damaged spinal cord tissues showed that IL-10 expression was increased and that locomotor function (as assessed by the Basso, Beattie, and Bresnahan (BBB) scale and the horizontal ladder test) was significantly improved in the RADA16/SP group compared to the control group. Our findings indicate that RADA16 modified with substance P effectively stimulates angiogenesis within the damaged spinal cord and is a candidate agent for promoting functional recovery post-SCI.