Ruslan K. Mursalov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ruslan K. Mursalov has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Elena Grigorevna Kulapina
Saratov State University, Saratov, Russia
3 shared publications Saratov State University
3 shared publications- Anastasia I. Voevodina
Saratov State University, 83, Astrakhanskaya str., Saratov, 410012, Russia
1 shared publication - Dmitry V. Silaev1 shared publication
- Elizaveta F. Ketrush1 shared publication
- Natalia A. Burmistrova
Institute of Chemistry, Saratov State University, Saratov 410012, Russia
1 shared publication
Latest Publications
- Open Access
- 21 March 2025
- Published by Saratov State University in Izvestiya of Saratov University. Chemistry. Biology. Ecology
- Vol. 25 (1)
Modified planar sensors for the separate detection of certain cephalosporin antibiotics
Modified screen-printed potentiometric sensors sensitive to cephalosporin antibiotics – cefuroxime (Cefur), cefotaxime (Ceftx), cefazolin (Cef) have been developed. Tetradecylammonium associates with complex compounds silver (I) – cefuroxime (cefotaxime) have been used as electroactive components. The role of magnetic nanoparticles Fe3O4 and cetylpyridinium chloride in improving the electroanalytical properties of sensors in solutions of the studied antibiotics is shown. Optimal ratios of modifiers in carbon-containing inks (Fe3O4 : CPCh = 1 : 2.5) have been found. The main electroanalytical characteristics of the modified sensors are determined. The introduction of a binary mixture of magnetic nanoparticles and cetylpyridinium chloride into carbon-containing inks leads to an improvement in the electroanalytical properties of planar sensors sensitive to cefuroxime, cefotaxime, cefazolin: at the same time, the detection limit of 1 · 10-6 (1 · 10-7 M) decreases, angular coefficients (55 ± 3 mV/pC) and linearity intervals of electrode functions (1 · 10-6 – 1 · 10-2 M), the response time is reduced – 26–30 seconds. The adsorption of surfactants at the interface ensures the stability of the suspension of nanoparticles and allows the concentration of analyte molecules. The possibility of separate determination of cephalosporin antibiotics in two- and three-component mixtures by projection methods of multidimensional data processing PLS-1 and PLS-2 is shown. The standard errors of calibration and prediction are estimated, on the basis of which the optimal number of latent variables for these methods is selected. It is established that all the studied models give high values of correlation coefficients and tangents of the slope of the “measured-predicted” dependencies close to one, which makes it possible to recommend these methods for practical use.
- 21 March 2025
- Published by Saratov State University in Izvestiya of Saratov University. Chemistry. Biology. Ecology
- Vol. 25 (1)
Open AccessModified planar sensors for the separate detection of certain cephalosporin antibiotics
Modified screen-printed potentiometric sensors sensitive to cephalosporin antibiotics – cefuroxime (Cefur), cefotaxime (Ceftx), cefazolin (Cef) have been developed. Tetradecylammonium associates with complex compounds silver (I) – cefuroxime (cefotaxime) have been used as electroactive components. The role of magnetic nanoparticles Fe3O4 and cetylpyridinium chloride in improving the electroanalytical properties of sensors in solutions of the studied antibiotics is shown. Optimal ratios of modifiers in carbon-containing inks (Fe3O4 : CPCh = 1 : 2.5) have been found. The main electroanalytical characteristics of the modified sensors are determined. The introduction of a binary mixture of magnetic nanoparticles and cetylpyridinium chloride into carbon-containing inks leads to an improvement in the electroanalytical properties of planar sensors sensitive to cefuroxime, cefotaxime, cefazolin: at the same time, the detection limit of 1 · 10-6 (1 · 10-7 M) decreases, angular coefficients (55 ± 3 mV/pC) and linearity intervals of electrode functions (1 · 10-6 – 1 · 10-2 M), the response time is reduced – 26–30 seconds. The adsorption of surfactants at the interface ensures the stability of the suspension of nanoparticles and allows the concentration of analyte molecules. The possibility of separate determination of cephalosporin antibiotics in two- and three-component mixtures by projection methods of multidimensional data processing PLS-1 and PLS-2 is shown. The standard errors of calibration and prediction are estimated, on the basis of which the optimal number of latent variables for these methods is selected. It is established that all the studied models give high values of correlation coefficients and tangents of the slope of the “measured-predicted” dependencies close to one, which makes it possible to recommend these methods for practical use.
- Open Access
- 18 December 2023
- Published by Saratov State University in Izvestiya of Saratov University. Chemistry. Biology. Ecology
- Vol. 23 (4)
Spectrophotometric determination of some β-lactam antibiotics in their binary mixtures using the method of partial least squares
The method has been proposed for the spectrophotometric determination of antibiotics of the cephalosporin (cefuroxime, ceftriaxone, cefotaxime, cefazolin) and penicillin (amoxicillin) groups using chemometric data processing (method of partial least squares, PLS). The absorption spectra of 24 binary mixtures of “cephalosporin – cephalosporin” and 16 binary mixtures of “cephalosporin – amoxicillin” with various concentrations in the range of 3–27 and 5–140 μg/ml have been recorded. The optimal number of latent variables for each chemometric method (PLS-1 and PLS-2) has been selected, which ranged from 2 to 7 depending on the type of model and the nature of the antibiotics. The smallest root mean square calibration errors (RMSEC) have been found for the ceftriaxone–cefazolin system, which have been 0.09 and 0.08 for PLS-1 and PLS-2, respectively. The smallest root mean square errors of prediction (RMSEP) for the mixture “cefuroxime – amoxicillin” have been 0.07 for both methods (PLS-1 and PLS-2). It has been established that equations of linear relationships “measured-predicted” are characterized by a regression coefficient and the square of the approximation coefficient close to 1; which indicates the high quality of the models. The relative error of determination in test mixtures has been 0.4–6.2% by the PLS-1 method for “cephalosporin – cephalosporin” mixtures, and 0.07–6.0% by the PLS-2 method. At the same time, there is no significant difference in the error in determining the components of the mixture, in contrast to the “cefuroxime – amoxicillin” system, for which the error is 0.1–1.1% for the first component and 2.6–14.7% for the second component using the PLS-1 method and 0.2–1.2% for the first component and 4.3–13.3% for the second component using the PLS-2 method. Thus, it has been shown that the use of chemometric methods ensures high accuracy of the spectrophotometric determination of the studied antibiotics with overlapping absorption bands in their mixtures.
- 18 December 2023
- Published by Saratov State University in Izvestiya of Saratov University. Chemistry. Biology. Ecology
- Vol. 23 (4)
Open AccessSpectrophotometric determination of some β-lactam antibiotics in their binary mixtures using the method of partial least squares
The method has been proposed for the spectrophotometric determination of antibiotics of the cephalosporin (cefuroxime, ceftriaxone, cefotaxime, cefazolin) and penicillin (amoxicillin) groups using chemometric data processing (method of partial least squares, PLS). The absorption spectra of 24 binary mixtures of “cephalosporin – cephalosporin” and 16 binary mixtures of “cephalosporin – amoxicillin” with various concentrations in the range of 3–27 and 5–140 μg/ml have been recorded. The optimal number of latent variables for each chemometric method (PLS-1 and PLS-2) has been selected, which ranged from 2 to 7 depending on the type of model and the nature of the antibiotics. The smallest root mean square calibration errors (RMSEC) have been found for the ceftriaxone–cefazolin system, which have been 0.09 and 0.08 for PLS-1 and PLS-2, respectively. The smallest root mean square errors of prediction (RMSEP) for the mixture “cefuroxime – amoxicillin” have been 0.07 for both methods (PLS-1 and PLS-2). It has been established that equations of linear relationships “measured-predicted” are characterized by a regression coefficient and the square of the approximation coefficient close to 1; which indicates the high quality of the models. The relative error of determination in test mixtures has been 0.4–6.2% by the PLS-1 method for “cephalosporin – cephalosporin” mixtures, and 0.07–6.0% by the PLS-2 method. At the same time, there is no significant difference in the error in determining the components of the mixture, in contrast to the “cefuroxime – amoxicillin” system, for which the error is 0.1–1.1% for the first component and 2.6–14.7% for the second component using the PLS-1 method and 0.2–1.2% for the first component and 4.3–13.3% for the second component using the PLS-2 method. Thus, it has been shown that the use of chemometric methods ensures high accuracy of the spectrophotometric determination of the studied antibiotics with overlapping absorption bands in their mixtures.
- Open Access
- 21 June 2022
- Published by Saratov State University in Izvestiya of Saratov University. Chemistry. Biology. Ecology
- Vol. 22 (2) , 133-141
Transport properties of unmodified and modified polyaniline nanotubes of amoxicillin-selective membranes
The transport processes occurring in polymer matrix characterize their physico-chemical properties, determine the directions of practical application. The literature data on ion transport in plasticized polymer membranes and theoretical aspects of membrane transport are critically reviewed. The effect of the modifier on the transport properties of membranes is shown. The article shows the possibility of implementing a new amoxicillin-selective plasticized membrane ([Ag(Amox)2]DMDSA), which includes a molecular imprinted polymer (MIP) – polyaniline nanotubes (PANI NT), which are of particular interest as modifiers of sensory and membrane compositions. The transport properties of unmodified and modified polyaniline nanotubes of plasticized polyvinyl chloride membranes have been studied. The effect of the concentration of near-membrane aqueous solutions of antibiotics, modifier on transport properties has been established. Quantitative characteristics of membrane transport are estimated: permeability coefficient and ion flux.
- 21 June 2022
- Published by Saratov State University in Izvestiya of Saratov University. Chemistry. Biology. Ecology
- Vol. 22 (2) , 133-141
Open AccessTransport properties of unmodified and modified polyaniline nanotubes of amoxicillin-selective membranes
The transport processes occurring in polymer matrix characterize their physico-chemical properties, determine the directions of practical application. The literature data on ion transport in plasticized polymer membranes and theoretical aspects of membrane transport are critically reviewed. The effect of the modifier on the transport properties of membranes is shown. The article shows the possibility of implementing a new amoxicillin-selective plasticized membrane ([Ag(Amox)2]DMDSA), which includes a molecular imprinted polymer (MIP) – polyaniline nanotubes (PANI NT), which are of particular interest as modifiers of sensory and membrane compositions. The transport properties of unmodified and modified polyaniline nanotubes of plasticized polyvinyl chloride membranes have been studied. The effect of the concentration of near-membrane aqueous solutions of antibiotics, modifier on transport properties has been established. Quantitative characteristics of membrane transport are estimated: permeability coefficient and ion flux.
- Open Access
- 22 March 2022
- Published by Saratov State University in Izvestiya of Saratov University. Chemistry. Biology. Ecology
- Vol. 22 (1)
Electroanalytical properties of planar sensors in aqueous environments of amoxicillin
- 22 March 2022
- Published by Saratov State University in Izvestiya of Saratov University. Chemistry. Biology. Ecology
- Vol. 22 (1)
Open AccessElectroanalytical properties of planar sensors in aqueous environments of amoxicillin