Kefu Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kefu Yu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Chuan Rong
Guangxi Univ, Sch Marine Sci, Guangxi Lab Study Coral Reefs South China Sea, Nanning 530004, Peoples R China
3 shared publicationsYinghui Wang
Guangxi Univ, Sch Marine Sci, Guangxi Lab Study Coral Reefs South China Sea, Nanning 530004, Peoples R China
3 shared publicationsYuanyuan Zhang
School of Marine Sciences, Guangxi Key Laboratory on the Study of Coral Reefs in the South China Sea, Guangxi University, Nanning 530004, China
3 shared publicationsKunling Huang
School of Marine Sciences, Guangxi Key Laboratory on the Study of Coral Reefs in the South China Sea, Guangxi University, Nanning 530004, China
2 shared publicationsMin Wei
School of Marine Sciences, Guangxi Key Laboratory on the Study of Coral Reefs in the South China Sea, Guangxi University, Nanning 530004, China
2 shared publicationsYanan Shao
Guangxi Univ, Sch Marine Sci, Guangxi Lab Study Coral Reefs South China Sea, Nanning 530004, Peoples R China
2 shared publications
Latest Publications
- Open Access
- 25 March 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (16) , 10088-10096
Kinetics and mechanisms of flumequine degradation by sulfate radical based AOP in different water samples containing inorganic anions
Many studies have reported that hydroxyl radical (HO˙) driven advanced oxidation processes (AOPs) could degrade fluoroquinolones (FQs) antibiotics effectively. Compared with HO˙, sulfate radical (SO4˙−) shows a similar oxidation capacity but a longer half-life. SO4˙− could cause chain reactions and resulted in the generation of halogen radicals and carbonate radicals from the main anions in sea water including Cl−, Br− and HCO3 −. However, few studies were focused on the degradation of FQs in marine aquaculture water and seawater, as well as the bioaccumulation of transformation products. As a typical member of FQs, flumequine (FLU) was degraded by UV/peroxodisulfate (PDS) AOPs in synthetic fresh water, marine aquaculture water and seawater. The reaction rate constants in the three water samples were 0.0348 min−1, 0.0179 min−1 and 0.0098 min−1, respectively. The reason was attributed to the inhibition of the anions as they could consume SO4˙− and initiate the quenching reaction of free radicals. When the pH value increased from 5 to 9, the reaction rate decreased from 0.0197 min−1 to 0.0066 min−1. The energy difference between HOMO and LUMO of FLU was calculated to be 8.07 eV indicating that FLU was a stable compound. The atoms on quinolone ring of FLU with high negative charge would be more vulnerable to attack by free radicals through electrophilic reactions. Two possible degradation pathways of FLU were inferred according to the degradation products. Preliminary bioaccumulation analysis of transformation products by the EPI suite software proved that the values of log Kow and log BCF of the final product P100 were less than those of FLU and the intermediates.
- 25 March 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (16) , 10088-10096
Open AccessKinetics and mechanisms of flumequine degradation by sulfate radical based AOP in different water samples containing inorganic anions
Many studies have reported that hydroxyl radical (HO˙) driven advanced oxidation processes (AOPs) could degrade fluoroquinolones (FQs) antibiotics effectively. Compared with HO˙, sulfate radical (SO4˙−) shows a similar oxidation capacity but a longer half-life. SO4˙− could cause chain reactions and resulted in the generation of halogen radicals and carbonate radicals from the main anions in sea water including Cl−, Br− and HCO3 −. However, few studies were focused on the degradation of FQs in marine aquaculture water and seawater, as well as the bioaccumulation of transformation products. As a typical member of FQs, flumequine (FLU) was degraded by UV/peroxodisulfate (PDS) AOPs in synthetic fresh water, marine aquaculture water and seawater. The reaction rate constants in the three water samples were 0.0348 min−1, 0.0179 min−1 and 0.0098 min−1, respectively. The reason was attributed to the inhibition of the anions as they could consume SO4˙− and initiate the quenching reaction of free radicals. When the pH value increased from 5 to 9, the reaction rate decreased from 0.0197 min−1 to 0.0066 min−1. The energy difference between HOMO and LUMO of FLU was calculated to be 8.07 eV indicating that FLU was a stable compound. The atoms on quinolone ring of FLU with high negative charge would be more vulnerable to attack by free radicals through electrophilic reactions. Two possible degradation pathways of FLU were inferred according to the degradation products. Preliminary bioaccumulation analysis of transformation products by the EPI suite software proved that the values of log Kow and log BCF of the final product P100 were less than those of FLU and the intermediates.
- 11 February 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (30) , 45421-45434
Inactivation of E. coli and Streptococcus agalactiae by UV/persulfate during marine aquaculture disinfection
Sulfate radical (•SO4−)–based advanced oxidation processes have attracted a great deal of attention for use in water disinfection because of their strong oxidation ability toward electron-rich moieties on microorganism molecules. However, a few studies have focused on the effects of •SO4− on pathogenic microorganism inactivation in marine aquaculture water containing various inorganic anions. We employed the gram-negative bacteria E. coli and gram-positive bacteria S. agalactiae as representatives to evaluate the application of UV/persulfate (S2O82−, PDS), to the disinfection of marine aquaculture water in a comprehensive manner. Total inactivation of 4.13ˍlog of E. coli cells and 4.74ˍlog of S. agalactiae cells was reached within 120 s in the UV/PDS system. The inactivation of pathogenic bacteria in marine aquaculture water increased with the increasing PDS concentration and UV intensity. An acidic pH was beneficial for UV/PDS inactivation. Halogen-free radicals showed a strong influence on the inactivation. Anions in seawater, including Cl−, Br−, and HCO3− inhibited the disinfection. The inactivation rates of pathogenic bacteria followed the order seawater < marine aquaculture water < freshwater. Pathogenic bacteria could also be effectively inactivated in actual marine aquaculture water and reservoir water. The analysis of the inactivation mechanisms showed that S2O82− was activated by UV to produce •SO4−, which damaged the cell membranes. In addition, antioxidant enzymes, including SOD and CAT, were induced. The genomic DNA was also damaged. Inorganic disinfection byproducts such as chlorate and bromate were not formed during the disinfection of marine aquaculture water, which indicated that UV/PDS was a safe and efficient disinfection method. Graphical abstract
- 11 February 2022
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 29 (30) , 45421-45434
Inactivation of E. coli and Streptococcus agalactiae by UV/persulfate during marine aquaculture disinfection
Sulfate radical (•SO4−)–based advanced oxidation processes have attracted a great deal of attention for use in water disinfection because of their strong oxidation ability toward electron-rich moieties on microorganism molecules. However, a few studies have focused on the effects of •SO4− on pathogenic microorganism inactivation in marine aquaculture water containing various inorganic anions. We employed the gram-negative bacteria E. coli and gram-positive bacteria S. agalactiae as representatives to evaluate the application of UV/persulfate (S2O82−, PDS), to the disinfection of marine aquaculture water in a comprehensive manner. Total inactivation of 4.13ˍlog of E. coli cells and 4.74ˍlog of S. agalactiae cells was reached within 120 s in the UV/PDS system. The inactivation of pathogenic bacteria in marine aquaculture water increased with the increasing PDS concentration and UV intensity. An acidic pH was beneficial for UV/PDS inactivation. Halogen-free radicals showed a strong influence on the inactivation. Anions in seawater, including Cl−, Br−, and HCO3− inhibited the disinfection. The inactivation rates of pathogenic bacteria followed the order seawater < marine aquaculture water < freshwater. Pathogenic bacteria could also be effectively inactivated in actual marine aquaculture water and reservoir water. The analysis of the inactivation mechanisms showed that S2O82− was activated by UV to produce •SO4−, which damaged the cell membranes. In addition, antioxidant enzymes, including SOD and CAT, were induced. The genomic DNA was also damaged. Inorganic disinfection byproducts such as chlorate and bromate were not formed during the disinfection of marine aquaculture water, which indicated that UV/PDS was a safe and efficient disinfection method. Graphical abstract
- 1 April 2019
- Published by Elsevier in Separation and Purification Technology
- Vol. 212, 528-535
Transformation of antibacterial agent roxithromycin in sodium hypochlorite disinfection process of different water matrices
- 1 April 2019
- Published by Elsevier in Separation and Purification Technology
- Vol. 212, 528-535
Transformation of antibacterial agent roxithromycin in sodium hypochlorite disinfection process of different water matrices
- 25 September 2018
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 25 (33) , 33196-33206
Formation of disinfection byproducts from sulfamethoxazole during sodium hypochlorite disinfection of marine culture water
The fates of the antibiotic sulfamethoxazole (SMX) in the chlorination of fresh water, simulated brackish marine culture water, and marine water were investigated. SMX was oxidized by sodium hypochlorite (NaClO) at different reaction rates in the different samples. The oxidation of SMX followed pseudo-first-order kinetics, and the rate constant was the largest in marine water (3.44 min−1), as Br− ions promote the oxidation reaction. Moreover, the kinds of disinfection byproducts (DBPs) were also affected by Br− ions. Br-DBPs were found in the simulated brackish marine culture water and marine water disinfection systems. The structures of the DBPs indicated that S-C cleavage, polymerization, S-N hydrolysis, chlorine/bromine substitution, and desulfonation reactions occurred on SMX during the disinfection process. EPI (Estimation Programs Interface) Suite™ and absorbable organic halogen (AOX) analysis were used to evaluate the toxicity of the DBPs. The results suggested that DBPs in the simulated brackish marine culture water and marine water systems were more toxic than those in the fresh water system.
- 25 September 2018
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 25 (33) , 33196-33206
Formation of disinfection byproducts from sulfamethoxazole during sodium hypochlorite disinfection of marine culture water
The fates of the antibiotic sulfamethoxazole (SMX) in the chlorination of fresh water, simulated brackish marine culture water, and marine water were investigated. SMX was oxidized by sodium hypochlorite (NaClO) at different reaction rates in the different samples. The oxidation of SMX followed pseudo-first-order kinetics, and the rate constant was the largest in marine water (3.44 min−1), as Br− ions promote the oxidation reaction. Moreover, the kinds of disinfection byproducts (DBPs) were also affected by Br− ions. Br-DBPs were found in the simulated brackish marine culture water and marine water disinfection systems. The structures of the DBPs indicated that S-C cleavage, polymerization, S-N hydrolysis, chlorine/bromine substitution, and desulfonation reactions occurred on SMX during the disinfection process. EPI (Estimation Programs Interface) Suite™ and absorbable organic halogen (AOX) analysis were used to evaluate the toxicity of the DBPs. The results suggested that DBPs in the simulated brackish marine culture water and marine water systems were more toxic than those in the fresh water system.
- 1 September 2017
- Published by Elsevier in Chemosphere
- Vol. 182, 245-254
Oxidation of the antibacterial agent norfloxacin during sodium hypochlorite disinfection of marine culture water
- 1 September 2017
- Published by Elsevier in Chemosphere
- Vol. 182, 245-254
Oxidation of the antibacterial agent norfloxacin during sodium hypochlorite disinfection of marine culture water