Latest Publications

  • Open Access

    Noise Reduction in Brain CT: A Comparative Study of Deep Learning and Hybrid Iterative Reconstruction Using Multiple Parameters

    by Yusuke Inoue, Hiroyasu Itoh, Hirofumi Hata, Hiroki Miyatake, Kohei Mitsui, Shunichi Uehara, Chisaki Masuda

    Objectives: We evaluated the noise reduction effects of deep learning reconstruction (DLR) and hybrid iterative reconstruction (HIR) in brain computed tomography (CT). Methods: CT images of a 16 cm dosimetry phantom, a head phantom, and the brains of 11 patients were reconstructed using filtered backprojection (FBP) and various levels of DLR and HIR. The slice thickness was 5, 2.5, 1.25, and 0.625 mm. Phantom imaging was also conducted at various tube currents. The noise reduction ratio was calculated using FBP as the reference. For patient imaging, overall image quality was visually compared between DLR and HIR images that exhibited similar noise reduction ratios. Results: The noise reduction ratio increased with increasing levels of DLR and HIR in phantom and patient imaging. For DLR, noise reduction was more pronounced with decreasing slice thickness, while such thickness dependence was less evident for HIR. Although the noise reduction effects of DLR were similar between the head phantom and patients, they differed for the dosimetry phantom. Variations between imaging objects were small for HIR. The noise reduction ratio was low at low tube currents for the dosimetry phantom using DLR; otherwise, the influence of the tube current was small. In terms of visual image quality, DLR outperformed HIR in 1.25 mm thick images but not in thicker images. Conclusions: The degree of noise reduction using DLR depends on the slice thickness, tube current, and imaging object in addition to the level of DLR, which should be considered in the clinical use of DLR. DLR may be particularly beneficial for thin-slice imaging.

  • Open Access

    Age-Dependent Changes in Effective Dose in Pediatric Brain CT: Comparisons of Estimation Methods

    by Yusuke Inoue, Masahiro Mori, Hiroyasu Itoh, Kohei Mitsui, Hiroki Miyatake, Takuro Yamane, Hirofumi Hata

    The effective dose (ED) in computed tomography (CT) may be calculated by multiplying the dose–length product (DLP) by a conversion factor. As children grow, automatic exposure control increases the DLP, while the conversion factor decreases; these two changes affect the ED in opposite ways. The aim of this study was to investigate the methods of ED estimation according to age in pediatric brain CT. We retrospectively analyzed 980 brain CT scans performed for various clinical indications in children. The conversion factor at each age, in integer years, was determined based on the values at 0, 1, 5, and 10 years provided by the International Commission on Radiological Protection (ICRP), using a curve (curve method) or lines (linear method). In the simple method, the ED was estimated using the ICRP conversion factor for the closest age. We also analyzed the ED estimated by a radiation dose management system. Although the median DLP at each age increased with age, the median ED estimated by the curve method was highest at 0 years, decreased with age, and then plateaued at 9 years. The linear method yielded mildly different results, especially at 2 and 3 years. The ED estimated by the simple method or the radiation dose management system showed inconsistent, up-and-down changes with age. In conclusion, the ED in pediatric brain CT decreases with age despite increased DLP. Determination of the conversion factor at each age using a curve is expected to contribute to estimating the ED in pediatric CT according to age.


  • Open Access

    Relationships of Radiation Dose Indices with Body Size Indices in Adult Body Computed Tomography

    by Yusuke Inoue, Hiroyasu Itoh, Kazunori Nagahara, Hirofumi Hata, Kohei Mitsui

    We investigated the relationships between radiation dose indices and body size indices in adult body computed tomography (CT). A total of 3200 CT scans of the thoracic, abdominal, abdominopelvic, or thoraco-abdominopelvic regions performed using one of four CT scanners were analyzed. Volume CT dose index (CTDIvol) and dose length product (DLP) were compared with various body size indices derived from CT images (water-equivalent diameter, WED; effective diameter, ED) and physical measurements (weight, weight/height, body mass index, and body surface area). CTDIvol showed excellent positive linear correlations with WED and ED. CTDIvol also showed high linear correlations with physical measurement-based indices, whereas the correlation coefficients were lower than for WED and ED. Among the physical measurement-based indices, weight/height showed the strongest correlations, followed by weight. Compared to CTDIvol, the correlation coefficients with DLP tended to be lower for WED, ED, and weight/height and higher for weight. The standard CTDIvol values at 60 kg and dose increase ratios with increasing weight, estimated using the regression equations, differed among scanners. Radiation dose indices closely correlated with body size indices such as WED, ED, weight/height, and weight. The relationships between dose and body size differed among scanners, indicating the significance of dose management considering body size.


  • Open Access

    Automatic Exposure Control Attains Radiation Dose Modulation Matched with the Head Size in Pediatric Brain CT

    by Yusuke Inoue, Hiroyasu Itoh, Hiroki Miyatake, Hirofumi Hata, Ryosuke Sasa, Nao Shiibashi, Kohei Mitsui

    We investigated the relationship between the head size and radiation dose in pediatric brain computed tomography (CT) to evaluate the validity of automatic exposure control (AEC). Phantom experiments were performed to assess image noise with and without AEC, and indicated that AEC decreased differences in noise between slices of different section sizes. Retrospective analysis was conducted on 980 pediatric brain CT scans where the tube current was determined using AEC. The water equivalent diameter (WED) was employed as an index of the head size, and mean WED for each image set (WEDmean) and WED for each slice (WEDslice) were used for analysis. For the image-set-based analysis, volume CT dose index (CTDIvol) was compared to WEDmean. For the slice-based analysis, the tube current was compared to WEDslice using 20 of the 980 sets. Additionally, CTDIvol and WEDmean were compared between male and female patients matched for age, weight, or WEDmean. CTDIvol increased with increasing WEDmean, and an exponential curve was closely fitted to the relationship. Tube current changed similarly to the change in WEDslice for each image set, and an exponential curve was well-fitted to the plots of tube current against WEDslice when data from the 20 sets were pooled together. Although CTDIvol and WEDmean were slightly but significantly larger for male than female patients after matching for age or weight, a sex-dependent difference in CTDIvol was not found after matching for WEDmean. This study indicated successful dose modulation using AEC according to the head size for each patient and each slice location. The application of AEC to pediatric brain CT is recommended for radiation dose optimization.


  • Open Access

    Sample Size and Estimation of Standard Radiation Doses for Pediatric Brain CT

    by Yusuke Inoue, Hiroyasu Itoh, Nao Shiibashi, Ryosuke Sasa, Kohei Mitsui

    Estimation of the standard radiation dose at each imaging facility is required for radiation dose management, including establishment and utilization of the diagnostic reference levels. We investigated methods to estimate the standard dose for pediatric brain computed tomography (CT) using a small number of data. From 980 pediatric brain CT examinations, 25, 50, and 100 examinations were randomly extracted to create small, medium, and large datasets, respectively. The standard dose was estimated by applying grouping and curve-fitting methods for 20 datasets of each sample size. For the grouping method, data were divided into groups according to age or body weight, and the standard dose was defined as a median value in each group. For the curve-fitting methods, logarithmic, power, and bilinear functions were fitted to plots of radiation dose against age or weight, and the standard dose was calculated at the designated age or weight using the derived equation. When the sample size was smaller, the random variations of the estimated standard dose were larger. Better estimation of the standard dose was achieved with the curve-fitting methods than with the grouping method. Power fitting appeared to be more effective than logarithmic and bilinear fittings for suppressing random variation. Determination of the standard dose for pediatric brain CT by the curve-fitting method is recommended to improve radiation dose optimization at facilities performing the imaging procedure infrequently.


  • Open Access

    Radiation Dose Management in Pediatric Brain CT According to Age and Weight as Continuous Variables

    by Yusuke Inoue, Hiroyasu Itoh, Anri Waga, Ryosuke Sasa, Kohei Mitsui

    The diagnostic reference levels (DRLs) for pediatric brain computed tomography (CT) are provided for groups divided according to age. We investigated the relationships of radiation dose indices (volume CT dose index and dose length product) with age and weight, as continuous variables, in pediatric brain CT. In a retrospective analysis, 980 pediatric brain CT examinations were analyzed. Curve fitting was performed for plots of the CT dose indices versus age and weight, and equations to estimate age- and weight-dependent standard dose indices were derived. Standard dose indices were estimated using the equations, and the errors were calculated. The results showed a biphasic increase in dose indices with increasing age and weight, characterized by a rapid initial and subsequent slow increase. Logarithmic, power, and bilinear functions were well fitted to the plots, allowing estimation of standard dose indices at an arbitrary age or weight. Error analysis suggested that weight was mildly better than age and that the best results were obtained with the bilinear function. Curve fitting of the relationship between CT dose indices and age or weight facilitates the determination of standard dose indices in pediatric brain CT at each facility and is expected to aid the establishment and application of the DRLs.


  • Lung Perfusion Scintigraphy in Eisenmenger Syndrome Due to Patent Ductus Arteriosus

    by Kohei Mitsui, Reiko Woodhams, Ryutarou Ukisu, Yusuke Inoue

    Eisenmenger syndrome refers to the elevation of pulmonary arterial pressure to the systemic level caused by an increased pulmonary vascular resistance with right-to-left shunt through an intracardiac or aortopulmonary communication. A 36-year-old woman with Eisenmenger syndrome due to patent ductus arteriosus underwent Tc-99m-MAA lung perfusion scintigraphy to evaluate right-to-left shunt. Whole-body imaging visualized extrapulmonary activity in both kidneys, spleen, and intestinal tract, confirming the presence of right-to-left shunt. Accumulation in the brain was visible but much weaker compared with that in the body trunk and was limited to the left cerebral hemisphere, which reflected the location of the shunt pathway.