Julia Chung
Research Subjects
Julia Chung has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Lior Sepunaru
University of California, Santa Barbara
4 shared publications - Kevin William Plaxco
University of California, Santa Barbara
2 shared publications Adelina Matevosyan
1 shared publicationAdriana Billante
Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, USA
1 shared publication- Alexander Eden
Department of Mechanical Engineering, University of California Santa Barbara, Santa Barbara, CA 93106, United States of America
1 shared publication - Beyon Miloyan
Federation University
1 shared publication
Latest Publications
- 22 February 2025
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 1 (4) , 552-559
Investigation of Noise at a Microelectrode during a Faradaic Reaction
Measurement of small currents is often impeded by a suboptimal signal-to-noise ratio, largely due to background noise. This background noise significantly constrains the range of catalysts accessible for interrogation via micro- and nanoscale electrochemistry. In response, this work reveals how background noise scales in the presence of induced Faradaic reactions. We measured noise under a series of electrochemical conditions and discovered that the induced noise from a Faradaic reaction scales directly with current. Complementary electrochemical impedance spectroscopy measurements demonstrated that diffusional resistance dictates the noise of Faradaic reactions, independent of the electrochemical mechanism. The noise source is thermal in origin and propagates in a predictable trend, which is inversely proportional to the equivalent diffusional resistance of the analyte. The universality of the observed phenomenon allows for better deconvolution of measured charge from background noise, thus assisting in achieving higher resolution and measurement precision, which is a key in micro- and nanoscale electrochemical measurements.
- 22 February 2025
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 1 (4) , 552-559
Investigation of Noise at a Microelectrode during a Faradaic Reaction
Measurement of small currents is often impeded by a suboptimal signal-to-noise ratio, largely due to background noise. This background noise significantly constrains the range of catalysts accessible for interrogation via micro- and nanoscale electrochemistry. In response, this work reveals how background noise scales in the presence of induced Faradaic reactions. We measured noise under a series of electrochemical conditions and discovered that the induced noise from a Faradaic reaction scales directly with current. Complementary electrochemical impedance spectroscopy measurements demonstrated that diffusional resistance dictates the noise of Faradaic reactions, independent of the electrochemical mechanism. The noise source is thermal in origin and propagates in a predictable trend, which is inversely proportional to the equivalent diffusional resistance of the analyte. The universality of the observed phenomenon allows for better deconvolution of measured charge from background noise, thus assisting in achieving higher resolution and measurement precision, which is a key in micro- and nanoscale electrochemical measurements.
- Open Access
- 14 May 2024
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 3 (6) , 1044-1050
Effects of storage conditions on the performance of an electrochemical aptamer-based sensor
The electrochemical aptamer-based (EAB) sensor platform is the only molecular monitoring approach yet reported that is (1) real time and effectively continuous, (2) selective enough to deploy in situ in the living body, and (3) independent of the chemical or enzymatic reactivity of its target, rendering it adaptable to a wide range of analytes. These attributes suggest the EAB platform will prove to be an important tool in both biomedical research and clinical practice. To advance this possibility, here we have explored the stability of EAB sensors upon storage, using retention of the target recognizing aptamer, the sensor's signal gain, and the affinity of the aptamer as our performance metrics. Doing so we find that low-temperature (−20 °C) storage is sufficient to preserve sensor functionality for at least six months without the need for exogenous preservatives.
- 14 May 2024
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 3 (6) , 1044-1050
Open AccessEffects of storage conditions on the performance of an electrochemical aptamer-based sensor
The electrochemical aptamer-based (EAB) sensor platform is the only molecular monitoring approach yet reported that is (1) real time and effectively continuous, (2) selective enough to deploy in situ in the living body, and (3) independent of the chemical or enzymatic reactivity of its target, rendering it adaptable to a wide range of analytes. These attributes suggest the EAB platform will prove to be an important tool in both biomedical research and clinical practice. To advance this possibility, here we have explored the stability of EAB sensors upon storage, using retention of the target recognizing aptamer, the sensor's signal gain, and the affinity of the aptamer as our performance metrics. Doing so we find that low-temperature (−20 °C) storage is sufficient to preserve sensor functionality for at least six months without the need for exogenous preservatives.
- 26 October 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 472
The role of applied potential on particle sizing precision in single-entity blocking electrochemistry
- 26 October 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 472
The role of applied potential on particle sizing precision in single-entity blocking electrochemistry
- Open Access
- 13 April 2022
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 1 (1) , 011604
On the Disinfection of Electrochemical Aptamer-Based Sensors
Electrochemical aptamer-based (EAB) sensors encompass the only biosensor approach yet reported that is simultaneously: (1) independent of the chemical or enzymatic reactivity of its target, rendering it general; (2) continuous and real-time; and (3) selective enough to deploy in situ in the living body. Consistent with this, in vivo EAB sensors supporting the seconds-resolved, real-time measurement of multiple drugs and metabolites have been reported, suggesting the approach may prove of value in biomedical research and the diagnosis, treatment, and monitoring of disease. However, to apply these devices in long-duration animal models, much less in human patients, requires that they be free of any significant pathogen load. Thus motivated, here we have characterized the compatibility of EAB sensors with standard sterilization and high-level disinfection techniques. Doing so, we find that, while many lead to significant sensor degradation, treatment with CIDEX OPA (0.55% ortho-phthalaldehyde) leads to effective disinfection without causing any detectable loss in sensor performance.
- 13 April 2022
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 1 (1) , 011604
Open AccessOn the Disinfection of Electrochemical Aptamer-Based Sensors
Electrochemical aptamer-based (EAB) sensors encompass the only biosensor approach yet reported that is simultaneously: (1) independent of the chemical or enzymatic reactivity of its target, rendering it general; (2) continuous and real-time; and (3) selective enough to deploy in situ in the living body. Consistent with this, in vivo EAB sensors supporting the seconds-resolved, real-time measurement of multiple drugs and metabolites have been reported, suggesting the approach may prove of value in biomedical research and the diagnosis, treatment, and monitoring of disease. However, to apply these devices in long-duration animal models, much less in human patients, requires that they be free of any significant pathogen load. Thus motivated, here we have characterized the compatibility of EAB sensors with standard sterilization and high-level disinfection techniques. Doing so, we find that, while many lead to significant sensor degradation, treatment with CIDEX OPA (0.55% ortho-phthalaldehyde) leads to effective disinfection without causing any detectable loss in sensor performance.
- 1 January 2010
- Published by American Psychological Association (APA)
Digit-Span Test Predicts Daily Functional Ability in Dementia
- 1 January 2010
- Published by American Psychological Association (APA)
Digit-Span Test Predicts Daily Functional Ability in Dementia