Jiawen Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiawen Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Houda Zhu
College of Water Resources and Architectural Engineering, Northwest A&F University, China
2 shared publications - Zhihua Xiong
College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling, China
2 shared publications - Aijun Zhang
School of Civil Engineering, Xijing University, Xi’an, China
1 shared publication - Chen Liu
College of Water Resources and Architectural Engineering, Northwest A&F University, Xianyang 712100, China
1 shared publication - Xuyao Liu
Northwest A&F University, China
1 shared publication - Zhuoxi Liang
Northwest A&F University, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 19 (3)
Ultimate Bending Strength Evaluation of MVFT Composite Girder by using Finite Element Method and Machine Learning Regressors
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Latin American Journal of Solids and Structures
- Vol. 19 (3)
Open AccessUltimate Bending Strength Evaluation of MVFT Composite Girder by using Finite Element Method and Machine Learning Regressors
- Open Access
Seismic Fragility Evaluation of Simply Supported Aqueduct Accounting for Water Stop’s Leakage Risk
Due to the demands of booming Chinese cities and the increase in urban residents, the safety of aqueduct water transportation structures is noteworthy. A lot of old aqueducts were built in the 1990s and even earlier in the last century and may become vulnerable to potential earthquakes. This paper deals with an evaluation of an aqueduct’s seismic vulnerability accounting for leakage risk. Based on the Hua Shigou aqueduct in Ningxia, a probabilistic investigation was carried out to obtain the seismic fragility using Latin hypercube sampling. In the numerical study, the superstructure and substructure of the aqueduct were modeled as beam elements, and the lumped mass method was adopted to simulate the fluid–structure interaction. The rubber water stop’s mechanical performance was studied, and its damage states were proposed. Parametric numerical models were then subjected to a set of ground motions according to incremental dynamic analysis (IDA), which contained probabilistic parameters such as water, concrete strength, and bearing performance degradation. Both the system and component levels of the old aqueduct’s seismic fragility curves were obtained. It was found that the probability of the water stop’s leakage risk is significantly elevated with the increase in ground motion.
Open AccessSeismic Fragility Evaluation of Simply Supported Aqueduct Accounting for Water Stop’s Leakage Risk
Due to the demands of booming Chinese cities and the increase in urban residents, the safety of aqueduct water transportation structures is noteworthy. A lot of old aqueducts were built in the 1990s and even earlier in the last century and may become vulnerable to potential earthquakes. This paper deals with an evaluation of an aqueduct’s seismic vulnerability accounting for leakage risk. Based on the Hua Shigou aqueduct in Ningxia, a probabilistic investigation was carried out to obtain the seismic fragility using Latin hypercube sampling. In the numerical study, the superstructure and substructure of the aqueduct were modeled as beam elements, and the lumped mass method was adopted to simulate the fluid–structure interaction. The rubber water stop’s mechanical performance was studied, and its damage states were proposed. Parametric numerical models were then subjected to a set of ground motions according to incremental dynamic analysis (IDA), which contained probabilistic parameters such as water, concrete strength, and bearing performance degradation. Both the system and component levels of the old aqueduct’s seismic fragility curves were obtained. It was found that the probability of the water stop’s leakage risk is significantly elevated with the increase in ground motion.