Sophia Nazir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sophia Nazir has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Genhua Pan
Nanomaterials and Devices Laboratory (NMD), School of Engineering, Computing and Mathematics, University of Plymouth, Devon PL4 8AA, UK
2 shared publications - Muhsin Dogan
Nanomaterials and Devices Laboratory (NMD), School of Engineering, Computing and Mathematics, University of Plymouth, Devon PL4 8AA, UK
2 shared publications - Yinghui Wei
Faculty of Health and Life Sciences, University of Exeter, Exeter, UK
2 shared publications - David Jenkins
University of Plymouth, Plymouth, United Kingdom, UK
1 shared publication Genhua Pan
University of Plymouth, Plymouth, Plymouth, United Kingdom
1 shared publication- Oh Seok Kwon
SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University, Suwon, 16419, Republic of Korea; Department of Nano Science and Technology, Sungkyunkwan University, Suwon, 16419, Republic of Korea; Department of Nano Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 24 December 2025
- Published by Wiley in Alzheimer's & Dementia
- Vol. 21 (S2) , e098540
Electrochemical Detection of Alzheimer's Disease Biomarkers using Graphene based Biosensors
Background: Alzheimer's disease (AD) is a leading cause of neurodegenerative dementia, affecting over 50 million people worldwide. Early‐stage detection of AD is critical, as no disease‐modifying treatments or preventive strategies are currently available. However, the lack of sensitive and minimally invasive diagnostic tools for early AD detection remains a significant barrier to effective clinical trials, often contributing to trial failures. Method: In this study, we report on the development of an ultrasensitive electrochemical immunosensor for the detection of AD biomarkers, specifically tau‐441 and tau‐217, in body fluids. The sensor utilizes a graphene‐based electrochemical platform, which was fabricated as part of the EU Horizon Europe MSCA‐ITN‐DN CombiDiag project. The immunosensor operates through a printed graphene biosensor designed for the detection of body fluid biomarkers in the context of early‐stage dementia. Result: The proposed immunosensor demonstrates an impressive detection range from 1 fM to 1 pM with a femtomolar‐level limit of detection (LoD), which is the lowest reported LoD for a graphene‐based biosensor. This enhanced sensitivity is attributed to the use of a 3D graphene foam material, which offers a large surface area, increased reproducibility, and numerous binding sites for antibodies, leading to improved sensor performance. Conclusion: The high sensitivity of the developed biosensor enables the detection of AD biomarkers at low concentrations in various body fluids. This makes it applicable for monitoring biomarkers in different stages of disease progression and could be a valuable tool for early‐stage diagnosis and inclusion in clinical drug trials for AD.
- 24 December 2025
- Published by Wiley in Alzheimer's & Dementia
- Vol. 21 (S2) , e098540
Open AccessElectrochemical Detection of Alzheimer's Disease Biomarkers using Graphene based Biosensors
Background: Alzheimer's disease (AD) is a leading cause of neurodegenerative dementia, affecting over 50 million people worldwide. Early‐stage detection of AD is critical, as no disease‐modifying treatments or preventive strategies are currently available. However, the lack of sensitive and minimally invasive diagnostic tools for early AD detection remains a significant barrier to effective clinical trials, often contributing to trial failures. Method: In this study, we report on the development of an ultrasensitive electrochemical immunosensor for the detection of AD biomarkers, specifically tau‐441 and tau‐217, in body fluids. The sensor utilizes a graphene‐based electrochemical platform, which was fabricated as part of the EU Horizon Europe MSCA‐ITN‐DN CombiDiag project. The immunosensor operates through a printed graphene biosensor designed for the detection of body fluid biomarkers in the context of early‐stage dementia. Result: The proposed immunosensor demonstrates an impressive detection range from 1 fM to 1 pM with a femtomolar‐level limit of detection (LoD), which is the lowest reported LoD for a graphene‐based biosensor. This enhanced sensitivity is attributed to the use of a 3D graphene foam material, which offers a large surface area, increased reproducibility, and numerous binding sites for antibodies, leading to improved sensor performance. Conclusion: The high sensitivity of the developed biosensor enables the detection of AD biomarkers at low concentrations in various body fluids. This makes it applicable for monitoring biomarkers in different stages of disease progression and could be a valuable tool for early‐stage diagnosis and inclusion in clinical drug trials for AD.
- Open Access
- 10 December 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (12) , 806
Electrochemical Detection of Aβ42 and Aβ40 at Attomolar Scale via Optimised Antibody Loading on Pyr-NHS-Functionalised 3D Graphene Foam Electrodes
Alzheimer’s Disease (AD) is one of the most commonly seen neurodegenerative disorders, where early detection of its biomarkers is crucial for effective management. Conventional diagnostic methods are often expensive, time-consuming, and highly complex, which highlights an urgent need for point-of-care biosensing technology. In this work, we developed assays on three-dimensional (3D) graphene foam electrodes by functionalising them with a 1-Pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS) to enable effective antibody immobilisation for the detection of amyloid beta peptides (Aβ42 and Aβ40), key biomarkers for AD. Pyr-NHS linkers were used for stable functionalisation, followed by binding with Aβ42 and Aβ40 antibodies, and then bovine serum albumin (BSA) was employed as a blocking agent to minimise non-specific bindings on the electrode surface. Differential Pulse Voltammetry (DPV) measurements showed satisfactory stability over 12 days (RDS upper limit was <10%) and highly sensitive and specific detection of Aβ42 and Aβ40, with insignificant interference of tau217 protein. The biosensor exhibited a low limit of detection (LOD) with 252 aM for Aβ42 and 395 aM for Aβ40, covering 0.125 fM–1 nM and 0.125 fM–100 pM linear ranges, respectively. Further validation was conducted on spiked-diluted human plasma. This excellent analytical performance was attributed to the stable Pyr-NHS functionalisation, the 3D graphene foam enabling superior conductivity and a larger surface area on the working electrode, and the optimisation of antibody concentration for immobilisation. These promising results suggest that 3D graphene foam-based biosensors have considerable potential for early detection of AD biomarkers and developing cost-effective, portable, and reliable point-of-care devices.
- 10 December 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (12) , 806
Open AccessElectrochemical Detection of Aβ42 and Aβ40 at Attomolar Scale via Optimised Antibody Loading on Pyr-NHS-Functionalised 3D Graphene Foam Electrodes
Alzheimer’s Disease (AD) is one of the most commonly seen neurodegenerative disorders, where early detection of its biomarkers is crucial for effective management. Conventional diagnostic methods are often expensive, time-consuming, and highly complex, which highlights an urgent need for point-of-care biosensing technology. In this work, we developed assays on three-dimensional (3D) graphene foam electrodes by functionalising them with a 1-Pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS) to enable effective antibody immobilisation for the detection of amyloid beta peptides (Aβ42 and Aβ40), key biomarkers for AD. Pyr-NHS linkers were used for stable functionalisation, followed by binding with Aβ42 and Aβ40 antibodies, and then bovine serum albumin (BSA) was employed as a blocking agent to minimise non-specific bindings on the electrode surface. Differential Pulse Voltammetry (DPV) measurements showed satisfactory stability over 12 days (RDS upper limit was <10%) and highly sensitive and specific detection of Aβ42 and Aβ40, with insignificant interference of tau217 protein. The biosensor exhibited a low limit of detection (LOD) with 252 aM for Aβ42 and 395 aM for Aβ40, covering 0.125 fM–1 nM and 0.125 fM–100 pM linear ranges, respectively. Further validation was conducted on spiked-diluted human plasma. This excellent analytical performance was attributed to the stable Pyr-NHS functionalisation, the 3D graphene foam enabling superior conductivity and a larger surface area on the working electrode, and the optimisation of antibody concentration for immobilisation. These promising results suggest that 3D graphene foam-based biosensors have considerable potential for early detection of AD biomarkers and developing cost-effective, portable, and reliable point-of-care devices.
- Open Access
- 19 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (7) , 465
Electrochemical Immunosensor Using COOH-Functionalized 3D Graphene Electrodes for Sensitive Detection of Tau-441 Protein
Early diagnosis of Alzheimer’s disease (AD) is essential for effective treatment; however current diagnostic methods are often complex, costly, and unsuitable for point-of-care testing. Graphene-based biosensors offer an alternative due to their affordability, versatility, and high conductivity. However, graphene’s conductivity can be compromised when its carbon lattice is oxidized to introduce functional groups for biomolecule immobilization. This study addresses this challenge by developing an electrochemical immunosensor using carboxyl-modified commercial graphene foam (COOH-GF) electrodes. The conductivity of graphene is preserved by enabling efficient COOH modification through π–π non-covalent interactions, while antibody immobilization is optimized via EDC-NHS carbodiimide chemistry. The immunosensor detects tau-441, an AD biomarker, using differential pulse voltammetry (DPV), achieving a detection range of 1 fM–1 nM, with a limit of detection (LOD) of 0.14 fM both in PBS and human serum. It demonstrates high selectivity against other AD-related proteins, including tau-217, tau-181, amyloid beta (Aβ1-40 and Aβ1-42), and 1% BSA. These findings underscore its potential as a highly sensitive, cost-effective tool for early AD diagnosis.
- 19 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (7) , 465
Open AccessElectrochemical Immunosensor Using COOH-Functionalized 3D Graphene Electrodes for Sensitive Detection of Tau-441 Protein
Early diagnosis of Alzheimer’s disease (AD) is essential for effective treatment; however current diagnostic methods are often complex, costly, and unsuitable for point-of-care testing. Graphene-based biosensors offer an alternative due to their affordability, versatility, and high conductivity. However, graphene’s conductivity can be compromised when its carbon lattice is oxidized to introduce functional groups for biomolecule immobilization. This study addresses this challenge by developing an electrochemical immunosensor using carboxyl-modified commercial graphene foam (COOH-GF) electrodes. The conductivity of graphene is preserved by enabling efficient COOH modification through π–π non-covalent interactions, while antibody immobilization is optimized via EDC-NHS carbodiimide chemistry. The immunosensor detects tau-441, an AD biomarker, using differential pulse voltammetry (DPV), achieving a detection range of 1 fM–1 nM, with a limit of detection (LOD) of 0.14 fM both in PBS and human serum. It demonstrates high selectivity against other AD-related proteins, including tau-217, tau-181, amyloid beta (Aβ1-40 and Aβ1-42), and 1% BSA. These findings underscore its potential as a highly sensitive, cost-effective tool for early AD diagnosis.
- 12 April 2025
- Published by Springer Nature in Neurological Sciences
- Vol. 46 (8) , 3377-3390
The future of Alzheimer’s disease risk prediction: a systematic review
Background Alzheimer's disease is the most prevalent kind of age-associated dementia among older adults globally. Traditional diagnostic models for predicting Alzheimer's disease risks primarily rely on demographic and clinical data to develop policies and assess probabilities. However, recent advancements in machine learning (ML) and other artificial intelligence (AI) have shown promise in developing personalized risk models. These models use specific patient data from medical imaging and related reports. In this systematic review, different studies comprehensively examined the use of ML in magnetic resonance imaging (MRI), genetics, radiomics, and medical data for Alzheimer's disease risk assessment. I highlighted the results of our rigorous analysis of this research and emphasized the exciting potential of ML methods for Alzheimer's disease risk prediction. We also looked at current research projects and possible uses of AI-driven methods to enhance Alzheimer's disease risk prediction and enable more efficient investigating and individualized risk mitigation strategies. Aim and methods This review integrates both conventional and AI-based models to thoroughly analyze neuroimaging and non-neuroimaging features used in Alzheimer's disease prediction. This study examined factors related to imaging, radiomics, genetics, and clinical aspects. In addition, this study comprehensively presented machine learning for predicting the risk of Alzheimer's disease detection to benefit both beginner and expert researchers. Results A total of 700 publications from 2000 and 2024, were initially retrieved, out of which 120 studies met the inclusion criteria and were elected for review. The diagnosis of neurological disorders, along with the application of deep learning (DL) and machine learning (ML) were central themes in studies on the subject. When analyzing the medical implementation or design of innovative models, various machine learning models applied to neuroimaging and non-neuroimaging data may help researchers and clinicians become more informed. This review provides an extensive guide to the state of Alzheimer's disease risk assessment with artificial AI. Conclusion By integrating diverse neuroimaging and non-neuroimaging data sources, this study provides researchers with an alternative viewpoint on the application of AI in Alzheimer’s disease risk prediction emphasizing its potential to improve early diagnosis and personalized intervention strategies.
- 12 April 2025
- Published by Springer Nature in Neurological Sciences
- Vol. 46 (8) , 3377-3390
The future of Alzheimer’s disease risk prediction: a systematic review
Background Alzheimer's disease is the most prevalent kind of age-associated dementia among older adults globally. Traditional diagnostic models for predicting Alzheimer's disease risks primarily rely on demographic and clinical data to develop policies and assess probabilities. However, recent advancements in machine learning (ML) and other artificial intelligence (AI) have shown promise in developing personalized risk models. These models use specific patient data from medical imaging and related reports. In this systematic review, different studies comprehensively examined the use of ML in magnetic resonance imaging (MRI), genetics, radiomics, and medical data for Alzheimer's disease risk assessment. I highlighted the results of our rigorous analysis of this research and emphasized the exciting potential of ML methods for Alzheimer's disease risk prediction. We also looked at current research projects and possible uses of AI-driven methods to enhance Alzheimer's disease risk prediction and enable more efficient investigating and individualized risk mitigation strategies. Aim and methods This review integrates both conventional and AI-based models to thoroughly analyze neuroimaging and non-neuroimaging features used in Alzheimer's disease prediction. This study examined factors related to imaging, radiomics, genetics, and clinical aspects. In addition, this study comprehensively presented machine learning for predicting the risk of Alzheimer's disease detection to benefit both beginner and expert researchers. Results A total of 700 publications from 2000 and 2024, were initially retrieved, out of which 120 studies met the inclusion criteria and were elected for review. The diagnosis of neurological disorders, along with the application of deep learning (DL) and machine learning (ML) were central themes in studies on the subject. When analyzing the medical implementation or design of innovative models, various machine learning models applied to neuroimaging and non-neuroimaging data may help researchers and clinicians become more informed. This review provides an extensive guide to the state of Alzheimer's disease risk assessment with artificial AI. Conclusion By integrating diverse neuroimaging and non-neuroimaging data sources, this study provides researchers with an alternative viewpoint on the application of AI in Alzheimer’s disease risk prediction emphasizing its potential to improve early diagnosis and personalized intervention strategies.
- 6 May 2024
- Published by Springer Nature in Biomedical Materials & Devices
- Vol. 3 (1) , 216-236
Recent Advances and Applications of Graphene-Based Biosensors for Blood-Based Biomarkers in Neurodegenerative Diseases
- 6 May 2024
- Published by Springer Nature in Biomedical Materials & Devices
- Vol. 3 (1) , 216-236
Recent Advances and Applications of Graphene-Based Biosensors for Blood-Based Biomarkers in Neurodegenerative Diseases
- 2 May 2024
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 196 (10) , 7476-7502
Recent Progress in the Application of Tau Protein Biosensors for Diagnosis of Neurodegenerative Diseases
The microtubule-associated Tau protein is found in the central nervous system (CNS) in six major isoforms. Neurodegenerative diseases have been linked to post-translational changes of Tau, most notably phosphorylation. Tau protein’s molecular diversity is highly helpful in the identification of neurodegenerative illnesses. Nonetheless, one major obstacle to the early detection of brain illness is the nanoscale identification of tau proteins. The standard methods for identifying tau protein include western blotting, polymerase chain reaction (PCR), and real-time PCR. Enzyme-linked immunosorbent assay (ELISA) is another approach used. The limited sensitivity and specificity of these detections, together with the need for sophisticated equipment, are some of their drawbacks. The development of innovative and complex methods for tau protein screening is necessary to address the aforementioned issues. Biosensors are a cutting-edge instrument that may help identify various neurodegenerative biomarkers as early as feasible. This paper provides an overview of the most recent developments in the detection of neurodegenerative diseases employing biosensors built on nanotechnology and methods for imaging, electrochemical, and optical detection of the Tau protein. Furthermore, we outline the present difficulties and suggest a possible course for biosensor-based detection and intervention in the future. Graphical Abstract
- 2 May 2024
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 196 (10) , 7476-7502
Recent Progress in the Application of Tau Protein Biosensors for Diagnosis of Neurodegenerative Diseases
The microtubule-associated Tau protein is found in the central nervous system (CNS) in six major isoforms. Neurodegenerative diseases have been linked to post-translational changes of Tau, most notably phosphorylation. Tau protein’s molecular diversity is highly helpful in the identification of neurodegenerative illnesses. Nonetheless, one major obstacle to the early detection of brain illness is the nanoscale identification of tau proteins. The standard methods for identifying tau protein include western blotting, polymerase chain reaction (PCR), and real-time PCR. Enzyme-linked immunosorbent assay (ELISA) is another approach used. The limited sensitivity and specificity of these detections, together with the need for sophisticated equipment, are some of their drawbacks. The development of innovative and complex methods for tau protein screening is necessary to address the aforementioned issues. Biosensors are a cutting-edge instrument that may help identify various neurodegenerative biomarkers as early as feasible. This paper provides an overview of the most recent developments in the detection of neurodegenerative diseases employing biosensors built on nanotechnology and methods for imaging, electrochemical, and optical detection of the Tau protein. Furthermore, we outline the present difficulties and suggest a possible course for biosensor-based detection and intervention in the future. Graphical Abstract
- Open Access
- 20 February 2024
- Published by Wiley in Aging Medicine
- Vol. 7 (2) , 202-213
Salivary biomarkers: The early diagnosis of Alzheimer's disease
The precise identification of Alzheimer's disease and other prevalent neurodegenerative diseases remains a difficult issue that requires the development of early detection of the disease and inexpensive biomarkers that can replace the present cerebrospinal fluid and imaging biomarkers. Blood biomarkers, such as amyloid and neurofilament light, have been emphasized as an important and practical tool in a testing or examination procedure thanks to advancements in ultra‐sensitive detection techniques. Although saliva is not currently being researched for neurodegenerative diseases, it is an important source of biomarkers that can be used for the identification of diseases and has some advantages over other biofluids. While this may be true for most people, getting saliva from elderly people presents some significant challenges. In this overview, we will first discuss how saliva is created and how aging‐related illnesses may affect the amount and kind of saliva produced. The findings support the use of salivary amyloid protein, tau species, and novel biomarkers in the diagnosis of Alzheimer's disease.
- 20 February 2024
- Published by Wiley in Aging Medicine
- Vol. 7 (2) , 202-213
Open AccessSalivary biomarkers: The early diagnosis of Alzheimer's disease
The precise identification of Alzheimer's disease and other prevalent neurodegenerative diseases remains a difficult issue that requires the development of early detection of the disease and inexpensive biomarkers that can replace the present cerebrospinal fluid and imaging biomarkers. Blood biomarkers, such as amyloid and neurofilament light, have been emphasized as an important and practical tool in a testing or examination procedure thanks to advancements in ultra‐sensitive detection techniques. Although saliva is not currently being researched for neurodegenerative diseases, it is an important source of biomarkers that can be used for the identification of diseases and has some advantages over other biofluids. While this may be true for most people, getting saliva from elderly people presents some significant challenges. In this overview, we will first discuss how saliva is created and how aging‐related illnesses may affect the amount and kind of saliva produced. The findings support the use of salivary amyloid protein, tau species, and novel biomarkers in the diagnosis of Alzheimer's disease.
- Open Access
- 25 April 2023
- Published by Elsevier in Talanta Open
- Vol. 7
Recent progress of molecular diagnosis via CRISPR Cas-based biosensors and bioassays
- 25 April 2023
- Published by Elsevier in Talanta Open
- Vol. 7
Open AccessRecent progress of molecular diagnosis via CRISPR Cas-based biosensors and bioassays
- Open Access
- 31 March 2022
- Published by The Korean Vacuum Society in Applied Science and Convergence Technology
- Vol. 31 (2) , 40-45
Micro-Electromechanical Systems-based Sensors and Their Applications
Sophia Nazir and Oh Seok Kwon. Applied Science and Convergence Technology 2022;31:40-5. https://doi.org/10.5757/ASCT.2022.31.2.40
- 31 March 2022
- Published by The Korean Vacuum Society in Applied Science and Convergence Technology
- Vol. 31 (2) , 40-45
Open AccessMicro-Electromechanical Systems-based Sensors and Their Applications
Sophia Nazir and Oh Seok Kwon. Applied Science and Convergence Technology 2022;31:40-5. https://doi.org/10.5757/ASCT.2022.31.2.40