MNMeo Nguyen

Meo Nguyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Meo Nguyen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of supporting teeth quantity of surgical guide on the accuracy of the immediate implant in the maxillary central incisor: an in vitro study

    by Meo Nguyen, Huynh Kim Khanh Nguyen, Thien Nga Nguyen, Nam Cong-Nhat Huynh

    Introduction: Guided surgery for immediate anterior implants aims to reduce the time required for aesthetic and functional immediate loading. However, the limited surface area of anterior teeth for guide stabilization may affect the accuracy of implant positioning. This in vitro study evaluated the effect of the number of supporting teeth on the accuracy of immediate implants in the maxillary central incisor region. Methods: 28 replica implants were inserted into 28 upper jaw models, simulating immediate post-extraction sockets of tooth 11. Based on the number of supporting teeth, the implants were categorized into G1 (four adjacent teeth) and G2 (six adjacent teeth). The planned and actual implant positions were compared using the evaluation module of the implant planning software. Angular and 3D deviations were measured as the primary outcomes. Statistical analysis was performed using the two-sample t-test, with p-values less than 0.05 defined as statistically significant. Results: Between group G1 and G2, angular deviation was measured at 4.63 ± 0.71° and 3.59 ± 0.97°, respectively, while the implant apex 3D deviation was 2.08 ± 0.21 mm for G1 and 1.40 ± 0.27 mm for G2. These differences were statistically significant (p = 0.003 and p < 0.001, respectively). Other discrepancy variables in G2 demonstrated lower values but were not statistically significant compared to G1. Conclusion: The number of supporting teeth for the surgical guide can influence the accuracy of immediate implant surgery. While both four-teeth and six-teeth supports demonstrated acceptable clinical implant accuracy, a surgical guide supported by six teeth can enhance implant precision.


  • Open Access

    Effects of advanced platelet‐rich fibrin combined with xenogenic bone on human periodontal ligament stem cells

    by Meo Nguyen, Thuy Thu Nguyen, Ha Le Bao Tran, Dang Ngoc Tran, Lan Thi Quynh Ngo, Nam Cong‐Nhat Huynh

    Objectives: In this study, we aimed to investigate the effects of a mixture of advanced platelet‐rich fibrin (A‐PRF) and xenogenic bone substitute material (XBSM) on the proliferation and migration of human periodontal ligament stem cells (hPDLSCs) based on the in vitro release of growth factors.Material and Methods: The concentrations of platelet‐derived growth factor‐AB (PDGF‐AB) and vascular endothelial growth factor (VEGF) released by the A‐PRF‐XBSM mixture were estimated using enzyme‐linked immunoassay for up to 7 d. The A‐PRF‐XBSM mixture exudate was incubated with hPDLSCs. At Days 1, 3, 5, and 7, cell proliferation and migration were investigated by cell counting and wound‐healing assays.Results: PDGD‐AB and VEGF were released from the A‐PRF‐XBSM mixture exudate for up to 7 days. hPDLSCs were cultured in media with various concentrations of the A‐PRF‐XBSM mixture exudate and exhibited their proliferation and migration ability. Furthermore, the factors released from the 100% A‐PRF‐XBSM mixture exudate had a substantial effect on cell migration, whereas those released from 4% and 20% A‐PRF‐XBSM mixture exudates stimulated hPDLSC proliferation.Conclusions: A‐PRF‐XBSM mixture continuously released growth factors over 7 days and enhanced hPDLSC proliferation and migration. Therefore, A‐PRF in combination with XBSM might provide potential advantages for periodontal tissue regeneration.