GMGustav Magnusson

Gustav Magnusson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gustav Magnusson has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Gunnar Cedersund

    Department of Biomedical Engineering, Linköping University, Linköping, Sweden

    3 shared publications
  • Anders Tisell

    Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden

    2 shared publications
  • Charalampos Georgiopoulos

    Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden

    2 shared publications
  • Lovisa Tobieson

    Department of Neurosurgery in Linköping, and Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden

    2 shared publications
  • Maria Engström

    Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden

    2 shared publications
  • A. Dubey

    Gothenburg University

    1 shared publication

Latest Publications

  • Open Access

    How processing choices effect repeatability in BOLD–CVR imaging

    by Gustav Magnusson, Alex A Bhogal, Charalampos Georgiopoulos, Gunnar Cedersund, Lovisa Tobieson, Maria Engström, Anders Tisell

    Cerebrovascular reactivity (CVR) is increasingly recognized as a valuable clinical biomarker, making accurate, and reliable quantification essential, particularly in the absence of a gold-standard reference. However, both the acquisition and processing of CVR data are influenced by numerous methodological factors, including imaging technique, sequence parameters, vascular paradigm, and data processing strategies. These complexities can be daunting for newcomers and hinder methodological consistency across studies. To support both novice and experienced researchers, we systematically evaluated how different processing strategies affect CVR map repeatability, quantified using spatial intraclass correlation, across multiple vascular paradigms. Twenty-four healthy volunteers underwent BOLD–CVR imaging using CO 2 inhalation, breath-hold, and resting-state paradigms, each repeated in a test–retest setup. We found that optimal processing choices varied across paradigms and interacted in non-trivial ways. For example, the inclusion of motion-confounds and the application of temporal filtering require careful consideration, as they can introduce substantial collinearity in the regression model and reduce repeatability. We summarized these findings into practical insights to guide researchers in making sound methodological choices and promote consistency within the field.

  • Open Access

    High inspired CO2 target accuracy in mechanical ventilation and spontaneous breathing using the Additional CO2 method

    by Gustav Magnusson, Maria Engström, Charalampos Georgiopoulos, Gunnar Cedersund, Lovisa Tobieson, Anders Tisell

    Introduction: Cerebrovascular reactivity imaging (CVR) is a diagnostic method for assessment of alterations in cerebral blood flow in response to a controlled vascular stimulus. The principal utility is the capacity to evaluate the cerebrovascular reserve, thereby elucidating autoregulatory functioning. In CVR, CO2 gas challenge is the most prevalent method, which elicits a vascular response by alterations in inspired CO2 concentrations. While several systems have been proposed in the literature, only a limited number have been devised to operate in tandem with mechanical ventilation, thus constraining the majority CVR investigations to spontaneously breathing individuals.Methods: We have developed a new method, denoted Additional CO2, designed to enable CO2 challenge in ventilators. The central idea is the introduction of an additional flow of highly concentrated CO2 into the respiratory circuit, as opposed to administration of the entire gas mixture from a reservoir. By monitoring the main respiratory gas flow emanating from the ventilator, the CO2 concentration in the inspired gas can be manipulated by adjusting the proportion of additional CO2. We evaluated the efficacy of this approach in (1) a ventilator coupled with a test lung and (2) in spontaneously breathing healthy subjects. The method was evaluated by assessment of the precision in attaining target inspired CO2 levels and examination of its performance within a magnetic resonance imaging environment.Results and discussion: Our investigations revealed that the Additional CO2 method consistently achieved a high degree of accuracy in reaching target inspired CO2 levels in both mechanical ventilation and spontaneous breathing. We anticipate that these findings will lay the groundwork for a broader implementation of CVR assessments in mechanically ventilated patients.


  • Open Access

    High Inspired CO 2 Target Accuracy in Mechanical Ventilation and Spontaneous Breathing Using the Additional CO 2 Method

    by Gustav Magnusson, Charalampos Georgiopoulos, Gunnar Cedersund, Lovisa Tobieson, Maria Engström, Anders Tisell

    Cerebrovascular Reactivity Imaging (CVR) is a diagnostic method for assessment of alterations in cerebral blood flow in response to a controlled vascular stimulus. The principal utility is the capacity to evaluate the cerebrovascular reserve, thereby elucidating autoregulatory functioning. Over the past decade, CVR has accumulated large interest, emerging as an expanding research field and application in a diverse spectrum of patient populations. In CVR, CO 2 gas challenge is the most prevalent method, which elicits a vascular response by alterations in inspired CO 2 concentrations. While several systems have been proposed in the literature, only a limited number have been devised to operate in tandem with mechanical ventilation, thus constraining the majority CVR investigations to spontaneous breathing individuals. We have developed a new method, denoted Additional CO 2 , designed to enable CO 2 challenge in ventilators. The central idea is the introduction of an additional flow of highly concentrated CO 2 into the respiratory circuit, as opposed to administration of the entire gas mixture from a reservoir. By monitoring the main respiratory gas flow emanating from the ventilator, the CO 2 concentration in the inspired gas can be manipulated by adjusting the proportion of additional CO 2 . We evaluated the efficacy of this approach in controlled settings: 1) in a ventilator coupled with a test-lung and 2) in spontaneous breathing healthy volunteers. Additionally, we made a comparative analysis using a conventional method employing a gas reservoir containing a blend of O 2 , N 2 , and CO 2 in varying concentrations. The methods were evaluated by assessment of the precision in attaining target inspired CO 2 levels and examination of their performance within a Magnetic Resonance Imaging (MRI) environment. Our investigations revealed that the Additional CO 2 method consistently achieved a high degree of accuracy in reaching target inspired CO 2 levels in both mechanical ventilation and spontaneous breathing. We anticipate that these findings will lay the groundwork for a broader implementation of CVR assessments in mechanically ventilated patients.

  • Open Access

    Collisions of micron-sized charged water droplets in still air

    by G. Magnusson, A. Dubey, R. Kearney, G. P. Bewley, B. Mehlig

    We show that the relative dynamics of charged water droplets settling in still air contains fixed points determined by the combination of hydrodynamic interactions, particle and fluid inertia, and electrostatic forces. For droplets with large enough opposite charges, the stable manifold of a saddle forms a separatrix that divides colliding trajectories from those that do not collide. We analyzed experimental data of hydrodynamically interacting, micron-sized water droplets in still air with Lagrangian droplet tracking and with a numerical model including gravity, particle inertia, hydrodynamic interactions, fluid inertia, and Coulomb interactions. The predictions of the model are in excellent agreement with the experiments. A consequence of our findings is that, for large charges, collision outcomes are not sensitive to the breakdown of hydrodynamics at small distances.