Evangelos Syngounas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Evangelos Syngounas has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Maria K. Koukou
Energy and Environmental Research Laboratory, Department of Agricultural Development, Agri-Food and Natural Resources Management, National and Kapodistrian University of Athens, 34400 Psachna, Greece
8 shared publications Stavros Anagnostatos
8 shared publications- Dimitrios Tsimpoukis
Energy and Environmental Research Laboratory, Department of Agricultural Development, Agri-Food and Natural Resources Management, National and Kapodistrian University of Athens, 34400 Psachna, Greece
7 shared publications Michail Gr. Vrachopoulos
7 shared publicationsDimitrios Tsimpoukis
6 shared publications- Evangelos Bellos
Department of Mechanical Engineering, School of Engineering, University of West Attica, 250 Thivon & Petrou Ralli, 12244 Athens, Greece
6 shared publications
Latest Publications
- Open Access
- 20 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (4) , 2065
Performance Assessment of a Novel Transcritical CO2 Pumpless Rankine Cycle for Small-Scale Solar Power Generation in Building Stocks
This study introduces a novel transcritical CO2 pumpless Rankine power generation cycle based on the thermal compression concept, utilizing low-temperature renewable sources. The investigated theoretical system consists of a 5 kWe unit incorporating the aforementioned working cycle coupled with a 50 m2 evacuated tube solar collector arrangement installed on the rooftop of a multifamily house in Athens, Greece. The proposed innovative configuration is parametrically analyzed for different hot water inlet temperature levels ranging from 70 to 120 °C and its efficiency is compared to the typical Organic Rankine Cycle (ORC) topology employing different conventional refrigerants. The energetic assessment is made using validated mathematical models developed in MATLAB integrating the CoolProp library. The derived results show that the investigated topology increases the performance figures compared to the baseline system for all the examined refrigerants, leading up to over 15% thermal efficiency enhancement for operation under low heat source temperatures. Finally, the year-round operation of the proposed system generates up to 5221 kWh/year for the building.
- 20 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (4) , 2065
Open AccessPerformance Assessment of a Novel Transcritical CO2 Pumpless Rankine Cycle for Small-Scale Solar Power Generation in Building Stocks
This study introduces a novel transcritical CO2 pumpless Rankine power generation cycle based on the thermal compression concept, utilizing low-temperature renewable sources. The investigated theoretical system consists of a 5 kWe unit incorporating the aforementioned working cycle coupled with a 50 m2 evacuated tube solar collector arrangement installed on the rooftop of a multifamily house in Athens, Greece. The proposed innovative configuration is parametrically analyzed for different hot water inlet temperature levels ranging from 70 to 120 °C and its efficiency is compared to the typical Organic Rankine Cycle (ORC) topology employing different conventional refrigerants. The energetic assessment is made using validated mathematical models developed in MATLAB integrating the CoolProp library. The derived results show that the investigated topology increases the performance figures compared to the baseline system for all the examined refrigerants, leading up to over 15% thermal efficiency enhancement for operation under low heat source temperatures. Finally, the year-round operation of the proposed system generates up to 5221 kWh/year for the building.
- Open Access
Experimental Energy and Exergy Performance Evaluation of a Novel Pumpless Rankine Cycle (PRC) Unit Employing Low-Temperature Heat Sources
The current study experimentally investigates the performance of a novel pumpless Rankine cycle (PRC) configuration utilizing low-temperature heat sources. Precisely, a 1 kWe PRC configuration using R245fa refrigerant is tested under different heat source and heat sink temperature levels. The energetic and exergetic performance indexes are calculated using validated simulation models developed in MATLAB incorporating the CoolProp library. The derived efficiency results are compared with the corresponding indexes of a conventional ORC system used as the baseline. The findings show that for a hot water heat source temperature of 90 °C and a cold water heat sink temperature of 10 °C as the working conditions, the time-averaged thermal efficiency maximizes at 4.5%, while the corresponding time-averaged exergy efficiency is calculated at 31%. Additionally, the innovative PRC topology shows higher efficiency rates compared to the conventional ORC solution for all the working scenarios tested. For a heat sink of 40 °C and a heat source of 90 °C, the thermal efficiency and the exergy efficiency calculated for the PRC are 7.7% and 7.5% higher, respectively, than the baseline ORC system, showing improved exploitation potential.
Open AccessExperimental Energy and Exergy Performance Evaluation of a Novel Pumpless Rankine Cycle (PRC) Unit Employing Low-Temperature Heat Sources
The current study experimentally investigates the performance of a novel pumpless Rankine cycle (PRC) configuration utilizing low-temperature heat sources. Precisely, a 1 kWe PRC configuration using R245fa refrigerant is tested under different heat source and heat sink temperature levels. The energetic and exergetic performance indexes are calculated using validated simulation models developed in MATLAB incorporating the CoolProp library. The derived efficiency results are compared with the corresponding indexes of a conventional ORC system used as the baseline. The findings show that for a hot water heat source temperature of 90 °C and a cold water heat sink temperature of 10 °C as the working conditions, the time-averaged thermal efficiency maximizes at 4.5%, while the corresponding time-averaged exergy efficiency is calculated at 31%. Additionally, the innovative PRC topology shows higher efficiency rates compared to the conventional ORC solution for all the working scenarios tested. For a heat sink of 40 °C and a heat source of 90 °C, the thermal efficiency and the exergy efficiency calculated for the PRC are 7.7% and 7.5% higher, respectively, than the baseline ORC system, showing improved exploitation potential.
- Open Access
- 21 February 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 269
Energy and exergy performance investigation of a transcritical CO2 vapor ejector-based refrigeration system for marine provision plants
- 21 February 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 269
Open AccessEnergy and exergy performance investigation of a transcritical CO2 vapor ejector-based refrigeration system for marine provision plants
- Open Access
- 1 May 2024
- Published by Elsevier in SSRN Electronic Journal
Data-Driven Energy Efficiency Comparison between Operating R744 and R448a Supermarket Refrigeration Systems Based on Hybrid Experimental-Simulation Analysis
A comprehensive study is presented concerning the energy performance comparison between two distinct operating supermarket refrigeration arrangements located in separate stores in Athens, Greece. The first supermarket under investigation is supported by a transcritical R744 booster unit featuring parallel compression, liquid ejectors and internal heat exchangers, while the second supermarket is supported by one medium-temperature and one low-temperature R448A direct expansion arrangement. Detailed measurements of pressure, temperature and energy consumption of the compressor racks were collected and analyzed for the refrigeration setups of both supermarkets. By employing the obtained measurements, a calculation model is developed and verified for the R448A systems, which uses as inputs the ambient temperature and the refrigeration loads of the store and provides as output the corresponding compressors’ energy consumption. The calculated refrigeration loads of the R744 store are used as inputs in the developed R448A model, and the extracted energy consumption results are compared to the measured energy figures of the R744A unit. The parametric analysis revealed that for the compared systems and their respective settings, the R448A units outperform the R744A arrangement approximately above the ambient temperature of 24°C. Regarding the performance of the systems for operation under the conditions of the same supermarket, the analysis proved that the R744 unit consumes 0.90% less annual energy compared to the R448A systems, displaying 21.35% less energy consumption during January, but also 16.99% more energy consumption during July.
- 1 May 2024
- Published by Elsevier in SSRN Electronic Journal
Open AccessData-Driven Energy Efficiency Comparison between Operating R744 and R448a Supermarket Refrigeration Systems Based on Hybrid Experimental-Simulation Analysis
A comprehensive study is presented concerning the energy performance comparison between two distinct operating supermarket refrigeration arrangements located in separate stores in Athens, Greece. The first supermarket under investigation is supported by a transcritical R744 booster unit featuring parallel compression, liquid ejectors and internal heat exchangers, while the second supermarket is supported by one medium-temperature and one low-temperature R448A direct expansion arrangement. Detailed measurements of pressure, temperature and energy consumption of the compressor racks were collected and analyzed for the refrigeration setups of both supermarkets. By employing the obtained measurements, a calculation model is developed and verified for the R448A systems, which uses as inputs the ambient temperature and the refrigeration loads of the store and provides as output the corresponding compressors’ energy consumption. The calculated refrigeration loads of the R744 store are used as inputs in the developed R448A model, and the extracted energy consumption results are compared to the measured energy figures of the R744A unit. The parametric analysis revealed that for the compared systems and their respective settings, the R448A units outperform the R744A arrangement approximately above the ambient temperature of 24°C. Regarding the performance of the systems for operation under the conditions of the same supermarket, the analysis proved that the R744 unit consumes 0.90% less annual energy compared to the R448A systems, displaying 21.35% less energy consumption during January, but also 16.99% more energy consumption during July.
- Open Access
- 5 March 2024
- Published by Elsevier in SSRN Electronic Journal
Data-Driven Energy Efficiency Comparison between Operating R744 and R448a Supermarket Refrigeration Systems Based on Hybrid Experimental-Simulation Analysis
A comprehensive study is presented concerning the energy performance comparison between two distinct operating supermarket refrigeration arrangements located in separate stores in Athens, Greece. The first supermarket under investigation is supported by a transcritical R744 booster unit featuring parallel compression, liquid ejectors and internal heat exchangers, while the second supermarket is supported by one medium-temperature and one low-temperature R448A direct expansion arrangement. Detailed measurements of pressure, temperature and energy consumption of the compressor racks were collected and analyzed for the refrigeration setups of both supermarkets. By employing the obtained measurements, a calculation model is developed and verified for the R448A systems, which uses as inputs the ambient temperature and the refrigeration loads of the store and provides as output the corresponding compressors’ energy consumption. The calculated refrigeration loads of the R744 store are used as inputs in the developed R448A model, and the extracted energy consumption results are compared to the measured energy figures of the R744A unit. The parametric analysis revealed that for the compared systems and their respective settings, the R448A units outperform the R744A arrangement approximately above the ambient temperature of 24°C. Regarding the performance of the systems for operation under the conditions of the same supermarket, the analysis proved that the R744 unit consumes 0.90% less annual energy compared to the R448A systems, displaying 21.35% less energy consumption during January, but also 16.99% more energy consumption during July.
- 5 March 2024
- Published by Elsevier in SSRN Electronic Journal
Open AccessData-Driven Energy Efficiency Comparison between Operating R744 and R448a Supermarket Refrigeration Systems Based on Hybrid Experimental-Simulation Analysis
A comprehensive study is presented concerning the energy performance comparison between two distinct operating supermarket refrigeration arrangements located in separate stores in Athens, Greece. The first supermarket under investigation is supported by a transcritical R744 booster unit featuring parallel compression, liquid ejectors and internal heat exchangers, while the second supermarket is supported by one medium-temperature and one low-temperature R448A direct expansion arrangement. Detailed measurements of pressure, temperature and energy consumption of the compressor racks were collected and analyzed for the refrigeration setups of both supermarkets. By employing the obtained measurements, a calculation model is developed and verified for the R448A systems, which uses as inputs the ambient temperature and the refrigeration loads of the store and provides as output the corresponding compressors’ energy consumption. The calculated refrigeration loads of the R744 store are used as inputs in the developed R448A model, and the extracted energy consumption results are compared to the measured energy figures of the R744A unit. The parametric analysis revealed that for the compared systems and their respective settings, the R448A units outperform the R744A arrangement approximately above the ambient temperature of 24°C. Regarding the performance of the systems for operation under the conditions of the same supermarket, the analysis proved that the R744 unit consumes 0.90% less annual energy compared to the R448A systems, displaying 21.35% less energy consumption during January, but also 16.99% more energy consumption during July.
- Open Access
- 20 January 2023
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 18
Thermodynamic and economic analysis of a supermarket transcritical CO2 refrigeration system coupled with solar-fed supercritical CO2 Brayton and organic Rankine cycles
- 20 January 2023
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 18
Open AccessThermodynamic and economic analysis of a supermarket transcritical CO2 refrigeration system coupled with solar-fed supercritical CO2 Brayton and organic Rankine cycles
- 29 March 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
- Vol. 236 (6) , 1192-1209
Energetic, exergetic and financial evaluation of a solar-powered absorption chiller integration into a CO2 commercial refrigeration system
This study investigates the integration of a solar absorption chiller by means of subcooling to a CO2 booster system that serves the refrigeration needs of a supermarket refrigeration plant with an installed capacity of 80 kW and 20 kW for medium and low-temperature regimes, respectively. The proposed energy saving configuration is analyzed in an energetic, exergetic, and financial manner, using the climatic data for the city of Athens, Greece. The current approach constitutes the theoretical reference for the actual implementation of this novelty either in new plants or as a retrofit in existing ones. The proposed solution includes the employment of a single-stage absorption chiller operating with LiBr–H20 working pair, which is driven by heat produced in evacuated tube collectors installed in the store’s rooftop. The energy analysis is conducted with validated numerical models that are developed in MATLAB using the CoolProp library. The collecting area and the corresponding chiller capacity of the proposed configuration are selected through financial evaluation. More specifically, the collecting area is analyzed parametrically from 25 m2 to 200 m2. Finally, 100 m2 of collecting area with 60 kW of chiller capacity are proved to be the optimum solution financially with 8.4 years payback period and 44.57 k€ net present value. This optimum solution results in an annual power consumption decrease of 8.12% which leads to energy savings of 27.45 MWh/year.
- 29 March 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
- Vol. 236 (6) , 1192-1209
Energetic, exergetic and financial evaluation of a solar-powered absorption chiller integration into a CO2 commercial refrigeration system
This study investigates the integration of a solar absorption chiller by means of subcooling to a CO2 booster system that serves the refrigeration needs of a supermarket refrigeration plant with an installed capacity of 80 kW and 20 kW for medium and low-temperature regimes, respectively. The proposed energy saving configuration is analyzed in an energetic, exergetic, and financial manner, using the climatic data for the city of Athens, Greece. The current approach constitutes the theoretical reference for the actual implementation of this novelty either in new plants or as a retrofit in existing ones. The proposed solution includes the employment of a single-stage absorption chiller operating with LiBr–H20 working pair, which is driven by heat produced in evacuated tube collectors installed in the store’s rooftop. The energy analysis is conducted with validated numerical models that are developed in MATLAB using the CoolProp library. The collecting area and the corresponding chiller capacity of the proposed configuration are selected through financial evaluation. More specifically, the collecting area is analyzed parametrically from 25 m2 to 200 m2. Finally, 100 m2 of collecting area with 60 kW of chiller capacity are proved to be the optimum solution financially with 8.4 years payback period and 44.57 k€ net present value. This optimum solution results in an annual power consumption decrease of 8.12% which leads to energy savings of 27.45 MWh/year.
- Open Access
- 20 February 2022
- Published by Pivot Science Publications Corporation
- Vol. 2 (1) , 1-24
Integration of a solar-powered absorption chiller for performance enhancement of a supermarket CO2 refrigeration plant
Integration of a solar-powered absorption chiller for performance enhancement of a supermarket CO2 refrigeration plant
- 20 February 2022
- Published by Pivot Science Publications Corporation
- Vol. 2 (1) , 1-24
Open AccessIntegration of a solar-powered absorption chiller for performance enhancement of a supermarket CO2 refrigeration plant
Integration of a solar-powered absorption chiller for performance enhancement of a supermarket CO2 refrigeration plant