YYYasaman Yazdandoust

Yasaman Yazdandoust

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yasaman Yazdandoust has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Adele L. C. Mackowiak

    Translation Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland

    1 shared publication
  • Ali Forouzanfar

    Dental Research Center School of Dentistry Mashhad University of Medical Sciences Mashhad Iran mums.ac.ir

    1 shared publication
  • Alireza Boruziniat

    Dental Research Center, Department of Restorative and Cosmetic Dentistry, School of Dentistry, Mashhad University of Medical Science, Mashhad, Iran

    1 shared publication
  • Arsalan Shahri

    Dental Materials Research Center, Mashhad Dental School Mashhad University of Medical Sciences Mashhad Iran

    1 shared publication
  • Atoosa Talebi

    Department of Restorative and Cosmetic Dentistry, School of Dentistry, Mashhad University of Medical Science, Mashhad, Iran

    1 shared publication
  • Bernd Jung

    Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Switzerland

    1 shared publication

Latest Publications

  • Open Access

    EFFECT OF VENEERING PORCELAIN THICKNESS AND BACKGROUND SUBSTRATE ON THE COLOR MATCHING OF ZIRCONIA-BASED RESTORATIONS: AN IN-VITRO STUDY

    by Yasaman Yazdandoust, Delaram Ghaemi, Mohamad Reza Nakhaee, Arsalan Shahri, Saeed Akhlaghi, Sobhan Ghaemi

    Objetivo: Las restauraciones a base de zirconia se utilizan cada vez más en la odontología estética debido a su resistencia mecánica y sus favorables propiedades ópticas. Sin embargo, persisten desafíos para lograr una adecuada coincidencia de color, particularmente debido a la influencia del espesor de la porcelana de recubrimiento y el tono del sustrato. El objetivo de este estudio fue evaluar el efecto de estas dos variables sobre el color final de las restauraciones de zirconia. Materiales y métodos: Este estudio in vitro evaluó 33 discos de zirconia (tono A2, 0,5 mm de espesor), recubiertos con porcelana hasta alcanzar espesores finales de 0,8 mm, 1,0 mm o 1,2 mm (n = 11 por grupo). Cada espécimen fue medido sobre tres materiales de fondo: resina compuesta, titanio y níquel-cromo. Las coordenadas CIELAB se registraron mediante un colorímetro y las diferencias de color (ΔE₀₀) respecto del tono de referencia VITA se calcularon utilizando la fórmula CIEDE2000. Los datos se analizaron mediante ANOVA de medidas repetidas de dos factores, seguido de la prueba post hoc de Tukey. Resultados: Tanto el espesor de la porcelana como el tono del sustrato influyeron significativamente en los valores L*, a* y ΔE₀₀ (p < 0,01). El espesor no mostró un efecto significativo sobre los valores b*, mientras que el tono del sustrato sí lo hizo. El grupo con porcelana de 1,0 mm presentó los valores más favorables de ΔE₀₀ en todos los sustratos, siendo el titanio el que mostró consistentemente la peor coincidencia de color. Conclusión: El espesor de la porcelana y el tono del sustrato influyen significativamente en el color final de las restauraciones de zirconia. Un espesor de recubrimiento de 1,0 mm proporcionó la coincidencia de color más aceptable, especialmente sobre sustratos de resina compuesta y Ni-Cr. Estos hallazgos resaltan la importancia de optimizar tanto la estratificación del material como el manejo del sustrato en la práctica clínica.

  • Open Access

    Evaluating rapid water excitation techniques for 5D whole-heart fat-suppressed free-running cardiac MRI at 1.5T scanner

    by Yasaman Safarkhanlo, Jérôme Yerly, Mariana B. L. Falcão, Adele L. C. Mackowiak, Davide Piccini, Matthias Stuber, Bernd Jung, Christoph Graeni, Jessica A. M. Bastiaansen

    Background: Balanced steady-state free precession (bSSFP) sequences offer high SNR and excellent tissue contrast for whole-heart MRI. However, inadequate fat suppression can introduce artifacts, particularly with non-Cartesian readouts. This study aimed to compare novel rapid water-excitation (WE) pulses for 3D radial whole-heart free-running MRI at 1.5T, specifically Binomial Off-Resonant Rectangular (BORR), Lipid Insensitive Binomial Off-Resonant RF Excitation (LIBRE), and Lipid Insensitive Binomial Off-Resonant (LIBOR) pulses, alongside a Fast Interrupted Steady-State (FISS) and non-fat suppressed free-running bSSFP sequence. Methods: Three free-running MRI protocols (BORR, LIBRE, LIBOR) were optimized for fat suppression at 1.5T using a phantom. These protocols, along with FISS and non-fat suppressed bSSFP, were tested in phantom and five volunteers, with each acquisition lasting 3min and 41sec. SNR and CNR Water-Fat were measured in phantom data, while SNR and CNR Blood-Myocardium were assessed in volunteers using static gridded reconstructions. Motion-resolved reconstructions were used for qualitative assessments. SAR values were measured for each sequence, and statistical differences were analyzed using one-way ANOVA (p < 0.05). The pulse with the best combination of high SNR and low SAR was identified for further applications. Results: In phantom studies, LIBOR had the highest CNR Water-Fat (276.8 ± 2.5), followed by LIBRE (268.1 ± 2.6), BORR (249.9 ± 2.2), and FISS (212.7 ± 2.7), though these differences were not statistically significant (p > 0.05). FISS showed the highest SAR (1.41 W.kg -1 ), while LIBOR had the lowest (0.23 W.kg -1 ). In volunteers, BORR had the highest SNR in the ventricular blood pool (17.0 ± 1.5), and LIBRE had the highest CNR Blood-Fat (29.4 ± 9.3). FISS had the highest CNR Blood-Myocardium (29.0 ± 8.9), but the differences were not significant (p > 0.05). LIBOR consistently had the lowest SAR (0.26 W.kg -1 ). Conclusion: This study compared various fat-signal-suppression approaches in 3D contrast-free whole-heart free-running bSSFP MRI at 1.5T. Although the sequences performed similarly in SNR and CNR, LIBOR offered the lowest SAR, making it a promising candidate for future whole-heart MRI applications, particularly where RF energy deposition is a concern.

  • Open Access

    Effect of Extent of White Spot Lesions on the Esthetic Outcome After Treatment by the Resin Infiltration Technique: A Clinical Trial

    by Sima Gholami, Alireza Boruziniat, Atoosa Talebi, Yasaman Yazdandoust

    Objectives: This study aimed to assess the effect of extent of white spot lesions (WSLs) on the esthetic outcome (masking effect and durability) for 6 months after treatment by the resin infiltration technique. Materials and Methods: In this clinical trial, 79 teeth with WSLs in 18 patients were selected. The lesions were assigned to localized and generalized groups, and were all treated by resin infiltration. The color of WSLs was assessed at baseline, immediately after treatment, and 1, 3, and 6 months after treatment by using Easy Shade spectrophotometer and taking standard digital photographs. The surface area of WSLs was calculated on the photographs using MIP4Student software. Repeated Measures ANOVA was used to compare color change (∆E), and the Pearson’s correlation test was applied to analyze the association between the extent of lesions and ∆E (alpha=0.05). Results: A significant difference was found between the two groups in ∆E at different time points (P<0.05). Also, in both localized and generalized lesions, the pretreatment ∆E was significantly different from the ∆E values at different time points after treatment (P0.05). The Pearson test showed an inverse correlation between the extent of lesions and ∆E (P<0.05). Conclusion: The resin infiltration technique is successful in masking the WSLs, with a durability of at least 6 months. Color correction by this technique is more favorable in localized lesions.


  • Open Access

    Evaluating the Effect of Active Charcoal-Containing Toothpaste on Color Change, Microhardness, and Surface Roughness of Tooth Enamel and Resin Composite Restorative Materials

    by Ali Forouzanfar, Pouria Hasanpour, Yasaman Yazdandoust, Hosein Bagheri, Hamideh Sadat Mohammadipour

    Background and Objectives. Charcoal-containing toothpastes have become popular among many patients; however, there is inadequate scientific evidence on oral health. This study aimed to evaluate the color change, surface microhardness, and roughness of bovine enamel and composite resin submitted to simulated toothbrushing with a whitening toothpaste containing activated charcoal. Methods. Thirty-six bovine incisors and resin composite samples were prepared, stained with black tea, and then randomly divided into two groups. The samples were brushed with a charcoal-containing toothpaste (Colgate® MAX WHITE) and daily toothpaste (Colgate® Max Fresh) for 10,000 cycles. Before and after brushing cycles, color variables (ΔL, Δa, Δb), total color change (ΔE), plus Vickers microhardness were evaluated. Two samples of each group were prepared for surface roughness assessment via atomic force microscope. Data were analyzed by Shapiro–Wilk, Independent sample t-test and Mann–Whitney U tests. Results. According to the obtained results, ΔE and ΔL were significantly higher whereas Δa and Δb were noticeably lower in charcoal-containing toothpaste group in comparison with daily toothpaste in both composite and enamel samples. The microhardness of samples brushed with Colgate® MAX WHITE was significantly higher than that of Colgate® Max Fresh in enamel ( ), whereas no significant difference was found in composite resin samples ( ). Colgate® MAX WHITE enhanced the roughness of both enamel and composite surfaces. Conclusion. The charcoal-containing toothpaste could improve the color of both enamel and resin composite with no negative effect on microhardness. Nevertheless, its adverse roughening effect should be considered occasionally on composite restorations.


  • Open Access

    Diode Laser Excision of Focal Epithelial Hyperplasia (Heck’s Disease): A Case Report

    by Javad Sarabadani, Nasim Chiniforush, Yasaman Yazdandoust

    Introduction: Focal epithelial hyperplasia (FEH), also known as Heck’s disease, is a human papilloma virus induced proliferation of epithelial cells, which causes asymptomatic lesions in the oral mucosa. Heck’s disease is more prevalent among children or in a family. Despite the self-limitation of lesions, they may progress or cause esthetical and functional discomforts. Hence, early diagnosis is necessary. Case Presentation: A middle-aged man with a peripheral multiple soft, elevated, sessile, smooth, lobulated surface and nodular lesions in his right buccal mucosa was referred. The dimensions of the lesions varied from 5 to 25 mm. Through clinical and histopathological examinations, Heck’s disease was diagnosed. The diode laser (wavelengths of 980 nm), 1-W power using continuous waves) was applied serially (in 2 sessions with a 1-week interval) for surgically removing the lesions. The patient was followed up for 6 months with no lesion recurrence, and gradual healing was observed. Conclusion: The laser is an effective treatment with no scar remaining after the procedure and brings satisfaction to patients.