Aysenur Aykul Yagcioglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aysenur Aykul Yagcioglu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Aysegul Esdogan
KTO Karatay University
5 shared publications - Aysun Parlak Kocabay
Department of Audiology, Faculty of Health Sciences, Hacettepe University, Ankara, Turkey
3 shared publications - Betul Cicek Cinar
Hacettepe University
3 shared publications - Muhammed Pınar
Başkent Üniversitesi
3 shared publications - Işılay Öz
Department of Otolaryngology, Medical Faculty of Başkent University
2 shared publications - Aycan Comert
Department of Audiology, Faculty of Health Sciences, Hacettepe University, 06230 Ankara, Turkey
1 shared publication
Latest Publications
- Open Access
- 15 September 2026
- Published by Springer Nature in The Egyptian Journal of Otolaryngology
- Vol. 42 (1) , 239
The effect of sex on middle ear function in young adults
Background: The influence of sex on middle ear function has not been clearly established, and findings in the literature remain inconsistent. Evaluating tympanometric parameters together with middle ear resonance frequency may provide a more comprehensive understanding of middle ear mechanics and enhance the interpretation of clinical measurements. Objective: This study aimed to compare tympanometric parameters and middle ear resonance frequency between male and female young adults with normal hearing and to investigate potential sex-related differences. Methods: A total of 188 ears from normal-hearing young adults aged 18–30 years were included. Middle ear function was assessed using measurements of static compliance, tympanometric peak pressure, equivalent ear canal volume, tympanogram width, and middle ear resonance frequency. Results: No significant differences were found between males and females in terms of static compliance, tympanometric peak pressure, equivalent ear canal volume, or middle ear resonance frequency. Tympanogram width was the only parameter that demonstrated a significant sex-related difference, with higher values observed in males. Conclusion: In this cohort of normal-hearing young adults, sex was not associated with conventional tympanometric parameters or middle ear resonance frequency. Tympanogram width was the only parameter showing a significant difference between sexes. These findings suggest that sex may have a limited impact on middle ear function in young adulthood; however, the clinical relevance of the observed difference in tympanogram width warrants further investigation.
- 15 September 2026
- Published by Springer Nature in The Egyptian Journal of Otolaryngology
- Vol. 42 (1) , 239
Open AccessThe effect of sex on middle ear function in young adults
Background: The influence of sex on middle ear function has not been clearly established, and findings in the literature remain inconsistent. Evaluating tympanometric parameters together with middle ear resonance frequency may provide a more comprehensive understanding of middle ear mechanics and enhance the interpretation of clinical measurements. Objective: This study aimed to compare tympanometric parameters and middle ear resonance frequency between male and female young adults with normal hearing and to investigate potential sex-related differences. Methods: A total of 188 ears from normal-hearing young adults aged 18–30 years were included. Middle ear function was assessed using measurements of static compliance, tympanometric peak pressure, equivalent ear canal volume, tympanogram width, and middle ear resonance frequency. Results: No significant differences were found between males and females in terms of static compliance, tympanometric peak pressure, equivalent ear canal volume, or middle ear resonance frequency. Tympanogram width was the only parameter that demonstrated a significant sex-related difference, with higher values observed in males. Conclusion: In this cohort of normal-hearing young adults, sex was not associated with conventional tympanometric parameters or middle ear resonance frequency. Tympanogram width was the only parameter showing a significant difference between sexes. These findings suggest that sex may have a limited impact on middle ear function in young adulthood; however, the clinical relevance of the observed difference in tympanogram width warrants further investigation.
- 3 September 2026
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 27 (5) , 393-401
Association of AutoART eCAP thresholds with behavioral THR and MCL in pediatric cochlear implant users
A cochlear implant (CI) is an inner-ear prosthesis that electrically stimulates the auditory nerve through a surgically implanted electrode array (Dazert et al., 2020). Successful CI outcomes depen...
- 3 September 2026
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 27 (5) , 393-401
Association of AutoART eCAP thresholds with behavioral THR and MCL in pediatric cochlear implant users
A cochlear implant (CI) is an inner-ear prosthesis that electrically stimulates the auditory nerve through a surgically implanted electrode array (Dazert et al., 2020). Successful CI outcomes depen...
- 15 May 2026
- Published by KTO Karatay University in KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi
- Vol. 7 (1)
A Descriptive Analysis of Postgraduate Theses on Cochlear Implants in Türkiye
Aim: This study descriptively analyzed the distribution, methodological characteristics, and thematic tendencies of postgraduate theses on cochlear implants in Türkiye using an archive-based design. Material and Method: The search was conducted in the title field of the Council of Higher Education National Thesis Center database using the keywords “Koklear İmplant” and “Cochlear Implant.” The database search was performed in January 2025. All postgraduate theses published between 2001 and 2024 that contained these terms in their titles were included. Data were analyzed using descriptive statistics and presented as frequency (n) and percentage (%). Results: A total of 260 postgraduate theses were examined. Most theses were conducted at the master’s level (69.2%) and primarily within the departments of Ear, Nose, and Throat (ENT) and Audiology. The first thesis was published in 2001, and 2022 was the year with the highest number of completed theses. Hacettepe University contributed the largest number of theses. Most studies were conducted within the Institutes of Health Sciences. Frequently used assessment tools included language and speech evaluation tests, questionnaires, and audiological measurements. Early diagnosis and implantation were commonly associated with improved auditory and language outcomes. Conclusion: Postgraduate research on cochlear implants in Türkiye has increased over time and predominantly focuses on clinical and rehabilitative aspects. The findings provide an overview of academic trends in the field and guide future postgraduate research.
- 15 May 2026
- Published by KTO Karatay University in KTO Karatay Üniversitesi Sağlık Bilimleri Dergisi
- Vol. 7 (1)
A Descriptive Analysis of Postgraduate Theses on Cochlear Implants in Türkiye
Aim: This study descriptively analyzed the distribution, methodological characteristics, and thematic tendencies of postgraduate theses on cochlear implants in Türkiye using an archive-based design. Material and Method: The search was conducted in the title field of the Council of Higher Education National Thesis Center database using the keywords “Koklear İmplant” and “Cochlear Implant.” The database search was performed in January 2025. All postgraduate theses published between 2001 and 2024 that contained these terms in their titles were included. Data were analyzed using descriptive statistics and presented as frequency (n) and percentage (%). Results: A total of 260 postgraduate theses were examined. Most theses were conducted at the master’s level (69.2%) and primarily within the departments of Ear, Nose, and Throat (ENT) and Audiology. The first thesis was published in 2001, and 2022 was the year with the highest number of completed theses. Hacettepe University contributed the largest number of theses. Most studies were conducted within the Institutes of Health Sciences. Frequently used assessment tools included language and speech evaluation tests, questionnaires, and audiological measurements. Early diagnosis and implantation were commonly associated with improved auditory and language outcomes. Conclusion: Postgraduate research on cochlear implants in Türkiye has increased over time and predominantly focuses on clinical and rehabilitative aspects. The findings provide an overview of academic trends in the field and guide future postgraduate research.
- 15 October 2025
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 283 (2) , 803-809
Does listening behavior shape middle-ear function? A wideband tympanometry study in headphone users
Objective To investigate the impact of long-term in-ear headphone use on middle-ear transmission properties in young adults using wideband tympanometry (WBT), and to assess cochlear and reflex-level function through transient evoked otoacoustic emissions (TEOAEs) and acoustic reflex thresholds (ARTs). Methods Sixty-four ears from 32 female participants (aged 18–30 mean: 23 ± 2.83) were classified into a high exposure group (HEG; ≥3 h/day, ≥ 5 days/week, for ≥ 2 years) and a low exposure group (LEG; ≤1 h/day or no use). Wideband acoustic absorbance was recorded at both ambient and peak pressure conditions across 226–8000 Hz. Additional assessments included resonance frequency, equivalent ear canal volume, TEOAE amplitudes, and ipsilateral ARTs. Non-parametric comparisons were performed using Mann–Whitney U tests. Results Under ambient pressure, the HEG group demonstrated significantly lower absorbance than the LEG group between 500 and 1259 Hz and at 2 kHz (p < .05), while showing significantly higher absorbance at 5039 Hz (p < .05). Under peak pressure, significantly lower absorbance in HEG was observed at 793 Hz and 1 kHz, with higher absorbance again found at 5039 Hz (p < .05). No significant group differences were found in resonance frequency, ear canal volume, TEOAEs, or ARTs. Conclusion Prolonged in-ear headphone use appears to induce subtle, subclinical alterations in middle-ear sound transmission mechanics, without measurable cochlear dysfunction. Wideband tympanometry may serve as a sensitive tool for detecting early auditory changes associated with prolonged recreational sound exposure, underscoring the importance of considering middle-ear biomechanics in the broader context of auditory health monitoring suggesting that subclinical changes in middle-ear mechanics warrant longitudinal monitoring in young users of personal listening devices.
- 15 October 2025
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 283 (2) , 803-809
Does listening behavior shape middle-ear function? A wideband tympanometry study in headphone users
Objective To investigate the impact of long-term in-ear headphone use on middle-ear transmission properties in young adults using wideband tympanometry (WBT), and to assess cochlear and reflex-level function through transient evoked otoacoustic emissions (TEOAEs) and acoustic reflex thresholds (ARTs). Methods Sixty-four ears from 32 female participants (aged 18–30 mean: 23 ± 2.83) were classified into a high exposure group (HEG; ≥3 h/day, ≥ 5 days/week, for ≥ 2 years) and a low exposure group (LEG; ≤1 h/day or no use). Wideband acoustic absorbance was recorded at both ambient and peak pressure conditions across 226–8000 Hz. Additional assessments included resonance frequency, equivalent ear canal volume, TEOAE amplitudes, and ipsilateral ARTs. Non-parametric comparisons were performed using Mann–Whitney U tests. Results Under ambient pressure, the HEG group demonstrated significantly lower absorbance than the LEG group between 500 and 1259 Hz and at 2 kHz (p < .05), while showing significantly higher absorbance at 5039 Hz (p < .05). Under peak pressure, significantly lower absorbance in HEG was observed at 793 Hz and 1 kHz, with higher absorbance again found at 5039 Hz (p < .05). No significant group differences were found in resonance frequency, ear canal volume, TEOAEs, or ARTs. Conclusion Prolonged in-ear headphone use appears to induce subtle, subclinical alterations in middle-ear sound transmission mechanics, without measurable cochlear dysfunction. Wideband tympanometry may serve as a sensitive tool for detecting early auditory changes associated with prolonged recreational sound exposure, underscoring the importance of considering middle-ear biomechanics in the broader context of auditory health monitoring suggesting that subclinical changes in middle-ear mechanics warrant longitudinal monitoring in young users of personal listening devices.
- 23 September 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 145 (10) , 949-956
Validity and reliability of the Turkish version of the “cochlear implant use questionnaire”
Daily and regular use of cochlear implant (CI) processors is crucial for adapting to them and achieving optimal benefits. However, some obstacles to using CI processors exist, and it is important to identify these barriers and find solutions. This research evaluated the validity and reliability of the Turkish version of the Cochlear Implant Use Questionnaire (CIUQ) related to the barriers to cochlear implant use. This is a cross-cultural adaptation of the CIUQ questionnaire. One hundred thirty-four adult CI users aged 18-60 participated in the study. This study evaluated the construct validity of the CIUQ using confirmatory factor analysis and the internal consistency reliability using Cronbach's alpha coefficient. In the current study, the Kaiser-Meyer-Olkin coefficient was 0.75. The fit values obtained from the CFA applied to the CIUQ were satisfactory and within acceptable limits. Cronbach's α internal consistency coefficient for subscales ranged from 0.70 to 0.78, and the value was 0.8 for the overall scale. The Turkish adaptation of the CIUQ, which was developed to measure CI usage habits and barriers to daily CI usage, was determined to be a reliable and valid measurement tool for adults using CI.
- 23 September 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 145 (10) , 949-956
Validity and reliability of the Turkish version of the “cochlear implant use questionnaire”
Daily and regular use of cochlear implant (CI) processors is crucial for adapting to them and achieving optimal benefits. However, some obstacles to using CI processors exist, and it is important to identify these barriers and find solutions. This research evaluated the validity and reliability of the Turkish version of the Cochlear Implant Use Questionnaire (CIUQ) related to the barriers to cochlear implant use. This is a cross-cultural adaptation of the CIUQ questionnaire. One hundred thirty-four adult CI users aged 18-60 participated in the study. This study evaluated the construct validity of the CIUQ using confirmatory factor analysis and the internal consistency reliability using Cronbach's alpha coefficient. In the current study, the Kaiser-Meyer-Olkin coefficient was 0.75. The fit values obtained from the CFA applied to the CIUQ were satisfactory and within acceptable limits. Cronbach's α internal consistency coefficient for subscales ranged from 0.70 to 0.78, and the value was 0.8 for the overall scale. The Turkish adaptation of the CIUQ, which was developed to measure CI usage habits and barriers to daily CI usage, was determined to be a reliable and valid measurement tool for adults using CI.
- 23 September 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 145 (10) , 929-934
Comparison of bucket test and mobile application in pediatric utricular function assessment: a cross-sectional study
The Visual Vertical, an iOS mobile application, enables a more practical implementation of the subjective visual vertical (SVV) test compared to the bucket method. To determine the effectiveness of the iOS mobile application on SVV in children. A bucket test specifically designed for SVV assessment was administered to 44 children aged 11 to 14 years. The bucket was rotated 45° from the neutral (0°) head position in both clockwise and counter-clockwise rotations. Participants were instructed to indicate the moment they perceived the line inside the bucket as vertically aligned after 10 s. Angular deviations were recorded using both a protractor and an iOS application. Each participant underwent five trials in each rotational direction, and the mean was calculated to determine the SVV deviation angle. SVV deviation angle was determined as 0.92° in clockwise rotation and 0.96° in counter-clockwise rotation in the bucket test; and as 0.97° and 1.03° in the iOS application, respectively. No statistically significant difference was observed between SVV deviation angles in both applications (p > 0.05). Visual Vertical, an iOS mobile application, offers a practical and accessible alternative to the bucket method for assessing utricular function in children.
- 23 September 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 145 (10) , 929-934
Comparison of bucket test and mobile application in pediatric utricular function assessment: a cross-sectional study
The Visual Vertical, an iOS mobile application, enables a more practical implementation of the subjective visual vertical (SVV) test compared to the bucket method. To determine the effectiveness of the iOS mobile application on SVV in children. A bucket test specifically designed for SVV assessment was administered to 44 children aged 11 to 14 years. The bucket was rotated 45° from the neutral (0°) head position in both clockwise and counter-clockwise rotations. Participants were instructed to indicate the moment they perceived the line inside the bucket as vertically aligned after 10 s. Angular deviations were recorded using both a protractor and an iOS application. Each participant underwent five trials in each rotational direction, and the mean was calculated to determine the SVV deviation angle. SVV deviation angle was determined as 0.92° in clockwise rotation and 0.96° in counter-clockwise rotation in the bucket test; and as 0.97° and 1.03° in the iOS application, respectively. No statistically significant difference was observed between SVV deviation angles in both applications (p > 0.05). Visual Vertical, an iOS mobile application, offers a practical and accessible alternative to the bucket method for assessing utricular function in children.
- Open Access
- 17 September 2025
- Published by Springer Nature in The Egyptian Journal of Otolaryngology
- Vol. 41 (1) , 1-9
Examination of the relationship between the Groffman Visual Tracing test and Smooth Pursuit test: a cross-sectional analysis
Purpose: Smooth Pursuit and Groffman Visual Tracing (GVT) tests are tracking tests used to evaluate oculomotor processes. This study aims to investigate the relationship between GVT and the Smooth Pursuit test, which assesses various aspects of oculomotor function. Methods: The study was conducted with 41 participants aged between 18–30 years with normal hearing thresholds. The Smooth Pursuit test and the two-card GVT test were administered to participants. Results: A statistically significant moderate correlation (r = 0.497; p = 0.001) was observed between the horizontal and vertical Smooth Pursuit test asymmetry of the individuals participating in the study and the mean execution time of the GVT test card A and the left horizontal (LH), and a statistically significant moderate correlation (r = 0.443; p = 0.004) was observed between the mean execution time of the card B and the LH. Conclusion: The study suggests that the GVT is not a substitute for the Smooth Pursuit test in healthy adults; however, correlation may not have been obtained for the right eye due to limited sample size. Future research is recommended to examine the relationship between these two tests in a large sample size.
- 17 September 2025
- Published by Springer Nature in The Egyptian Journal of Otolaryngology
- Vol. 41 (1) , 1-9
Open AccessExamination of the relationship between the Groffman Visual Tracing test and Smooth Pursuit test: a cross-sectional analysis
Purpose: Smooth Pursuit and Groffman Visual Tracing (GVT) tests are tracking tests used to evaluate oculomotor processes. This study aims to investigate the relationship between GVT and the Smooth Pursuit test, which assesses various aspects of oculomotor function. Methods: The study was conducted with 41 participants aged between 18–30 years with normal hearing thresholds. The Smooth Pursuit test and the two-card GVT test were administered to participants. Results: A statistically significant moderate correlation (r = 0.497; p = 0.001) was observed between the horizontal and vertical Smooth Pursuit test asymmetry of the individuals participating in the study and the mean execution time of the GVT test card A and the left horizontal (LH), and a statistically significant moderate correlation (r = 0.443; p = 0.004) was observed between the mean execution time of the card B and the LH. Conclusion: The study suggests that the GVT is not a substitute for the Smooth Pursuit test in healthy adults; however, correlation may not have been obtained for the right eye due to limited sample size. Future research is recommended to examine the relationship between these two tests in a large sample size.
- Open Access
- 4 August 2025
- Published by Wiley in Brain and Behavior
- Vol. 15 (8) , e70725
Neural Correlates of Masking Level Differences: Evidence From Auditory Brainstem Responses
Objective: This study aimed to investigate the neural correlates of masking level differences (MLD) by examining their relationship with auditory brainstem responses (ABR) in normal‐hearing adults, to better elucidate the underlying brainstem mechanisms involved in MLD.Methods: A total of 37 normal‐hearing adults aged 18–30 years participated. Auditory evaluations included pure‐tone audiometry, tympanometry, MLD testing at 500 Hz under S₀N₀ and SπN₀ conditions, and click‐evoked ABR recordings. Correlations between ABR wave latencies (Waves I, III, and V) and interpeak intervals (I–III, III–V, and I–V) with MLD scores were analyzed using Spearman's correlation. Multiple linear regression analyses were conducted in two separate models to evaluate the predictive contribution of ABR components to MLD performance.Results: The mean MLD was 13.24 ± 2.18 dB, exceeding the clinical threshold for normal performance. No significant gender differences were observed in ABR or MLD measures. A moderate positive correlation was found between ABR Wave V latency and MLD scores (r = 0.58, p < 0.001). In regression analyses, Wave V latency was the only significant predictor of MLD scores (p = 0.003), explaining 28% of the variance. Other ABR components were not significant contributors.Conclusions: The results demonstrate that MLD performance is associated with ABR Wave V latency, suggesting that midbrain structures such as the inferior colliculus play a crucial role in binaural auditory processing. These findings support the utility of MLD as a behavioral index of brainstem integrity and its potential role in the evaluation of auditory dysfunction. While further research is needed to confirm these associations in clinical populations, MLD testing may offer valuable diagnostic insights into auditory brainstem dysfunction.
- 4 August 2025
- Published by Wiley in Brain and Behavior
- Vol. 15 (8) , e70725
Open AccessNeural Correlates of Masking Level Differences: Evidence From Auditory Brainstem Responses
Objective: This study aimed to investigate the neural correlates of masking level differences (MLD) by examining their relationship with auditory brainstem responses (ABR) in normal‐hearing adults, to better elucidate the underlying brainstem mechanisms involved in MLD.Methods: A total of 37 normal‐hearing adults aged 18–30 years participated. Auditory evaluations included pure‐tone audiometry, tympanometry, MLD testing at 500 Hz under S₀N₀ and SπN₀ conditions, and click‐evoked ABR recordings. Correlations between ABR wave latencies (Waves I, III, and V) and interpeak intervals (I–III, III–V, and I–V) with MLD scores were analyzed using Spearman's correlation. Multiple linear regression analyses were conducted in two separate models to evaluate the predictive contribution of ABR components to MLD performance.Results: The mean MLD was 13.24 ± 2.18 dB, exceeding the clinical threshold for normal performance. No significant gender differences were observed in ABR or MLD measures. A moderate positive correlation was found between ABR Wave V latency and MLD scores (r = 0.58, p < 0.001). In regression analyses, Wave V latency was the only significant predictor of MLD scores (p = 0.003), explaining 28% of the variance. Other ABR components were not significant contributors.Conclusions: The results demonstrate that MLD performance is associated with ABR Wave V latency, suggesting that midbrain structures such as the inferior colliculus play a crucial role in binaural auditory processing. These findings support the utility of MLD as a behavioral index of brainstem integrity and its potential role in the evaluation of auditory dysfunction. While further research is needed to confirm these associations in clinical populations, MLD testing may offer valuable diagnostic insights into auditory brainstem dysfunction.
- Open Access
- 18 May 2025
- Published by Wiley in Brain and Behavior
- Vol. 15 (5) , e70574
Visual Modulation of Acoustic Reflex Measurements: Insights Into Sensory Integration
Objective: The aim was to investigate the impact of visual tasks on acoustic reflex thresholds (ARTs) and AR latencies (ARLs) during AR measurements.Methods: A total of 31 participants (17 female, 14 male; mean age: 20.3 ± 1.8 years) with normal hearing and Type A tympanograms were included. ARTs and latencies were measured using a 226 Hz probe tone under five distinct conditions: (1) resting with no visual task, (2) eyes comfortably closed, (3) fixed gaze on a stationary object, (4) saccadic eye movements, and (5) optokinetic eye movements. Data were analyzed using repeated measures ANOVA with Bonferroni correction applied for post hoc comparisons.Results: ARTs were significantly lower in the condition of eyes closed compared to fixed gaze, at both 1 and 2 kHz (p < 0.05). ARLs at 500 Hz were significantly shorter in the condition of fixed gaze compared to saccadic eye movements (p < 0.05). A significant interaction between frequency and condition was observed for ARTs, indicating frequency‐specific modulation by visual tasks, whereas no significant frequency and condition interaction was found for ARLs.Conclusion: Visual tasks have a measurable effect on ARTs and latencies, likely due to cross‐modal interactions between the auditory and visual systems. These results highlight the importance of standardizing visual and attentional conditions during clinical AR testing. Further research is warranted to elucidate the underlying neural mechanisms and their clinical implications.
- 18 May 2025
- Published by Wiley in Brain and Behavior
- Vol. 15 (5) , e70574
Open AccessVisual Modulation of Acoustic Reflex Measurements: Insights Into Sensory Integration
Objective: The aim was to investigate the impact of visual tasks on acoustic reflex thresholds (ARTs) and AR latencies (ARLs) during AR measurements.Methods: A total of 31 participants (17 female, 14 male; mean age: 20.3 ± 1.8 years) with normal hearing and Type A tympanograms were included. ARTs and latencies were measured using a 226 Hz probe tone under five distinct conditions: (1) resting with no visual task, (2) eyes comfortably closed, (3) fixed gaze on a stationary object, (4) saccadic eye movements, and (5) optokinetic eye movements. Data were analyzed using repeated measures ANOVA with Bonferroni correction applied for post hoc comparisons.Results: ARTs were significantly lower in the condition of eyes closed compared to fixed gaze, at both 1 and 2 kHz (p < 0.05). ARLs at 500 Hz were significantly shorter in the condition of fixed gaze compared to saccadic eye movements (p < 0.05). A significant interaction between frequency and condition was observed for ARTs, indicating frequency‐specific modulation by visual tasks, whereas no significant frequency and condition interaction was found for ARLs.Conclusion: Visual tasks have a measurable effect on ARTs and latencies, likely due to cross‐modal interactions between the auditory and visual systems. These results highlight the importance of standardizing visual and attentional conditions during clinical AR testing. Further research is warranted to elucidate the underlying neural mechanisms and their clinical implications.
- 4 May 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 145 (7) , 627-632
Effect of environmental lighting on oculomotor tests results: a cross-sectional study
Oculomotor tests (saccade, smooth pursuit and optokinetic test) are routinely used in clinical evaluations of the central vestibular system. There is no clear information about the lighting (light or dark) of the environment in which oculomotor tests are performed. To determine optimum environment lighting by comparing oculomotor test results in bright and dark environments in healthy adults. The study included 31 healthy adults aged between 18 and 30 without hearing or balance complaints. The participants were administered the Oculomotor tests in light and dark environments. Velocity, accuracy, and latency were compared in the saccade test, gain and asymmetry in the smooth pursuit test, and gain values in the optokinetic test. The study found no statistically significant differences between light and dark environments in saccade, smooth pursuit, and optokinetic test (p> 0.05). However, the latency value determined, especially in the saccade test, was prolonged in the dark environment. The minimal differences between the two environments obtained as a result of the study may lead to false negative results in patients with suspected central vestibular system pathology, making differential diagnosis difficult.
- 4 May 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 145 (7) , 627-632
Effect of environmental lighting on oculomotor tests results: a cross-sectional study
Oculomotor tests (saccade, smooth pursuit and optokinetic test) are routinely used in clinical evaluations of the central vestibular system. There is no clear information about the lighting (light or dark) of the environment in which oculomotor tests are performed. To determine optimum environment lighting by comparing oculomotor test results in bright and dark environments in healthy adults. The study included 31 healthy adults aged between 18 and 30 without hearing or balance complaints. The participants were administered the Oculomotor tests in light and dark environments. Velocity, accuracy, and latency were compared in the saccade test, gain and asymmetry in the smooth pursuit test, and gain values in the optokinetic test. The study found no statistically significant differences between light and dark environments in saccade, smooth pursuit, and optokinetic test (p> 0.05). However, the latency value determined, especially in the saccade test, was prolonged in the dark environment. The minimal differences between the two environments obtained as a result of the study may lead to false negative results in patients with suspected central vestibular system pathology, making differential diagnosis difficult.