Li Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Li Yang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Bin Wang
Department of Automation, Tsinghua University, Beijing, China
2 shared publications - Kun Wu
School of Electronic and Information, Southwest Minzu University, Chengdu, China
2 shared publications - Xiaoping Zheng
Tsinghua University
2 shared publications - Zhiyu Lu
School of Electronic and Information, Southwest Minzu University, Chengdu, China
2 shared publications Bin Wang
1 shared publication- Bin Wang
Beijing Institute of Spacecraft Environment Engineering, Beijing 100094, China
1 shared publication
Latest Publications
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Magnetic Multitarget Recognition Based on Magnetic Gradient Tensor
The difficulty in magnetic multi-target recognition is that it is difficult to recognize magnetic targets with different magnetic moments and different depths at the same time. This is because the magnetic moment and depth of a magnetic target affect the strength of the generated magnetic field information, resulting in localization results that favor targets that generate stronger magnetic fields, while targets with weaker magnetic fields cannot be accurately identified. In addition, the traditional Euler equation-based multi-target localization method requires calibration of the sensor array before detection, which requires high calibration accuracy as it relies on the inversion of mathematical equations to solve for magnetic targets. To address this problem, this paper proposes an inverse tangent function imaging processing method based on the magnetic gradient tensor information (MGT) depth direction change rate. The method aims to balance the differences in magnetic field information between different magnetic targets and enhance the recognition of the horizontal position of targets with weaker magnetic fields. Based on this, a depth detection method based on MGT is proposed to acquire the depth information of magnetic targets. A grid-format data acquisition method is also proposed to obtain the MGT. The method does not require calibration of the sensor array or separation of the magnetic anomaly field from the total field. Simulation and experimental results show that the positioning error of this method for each magnetic target in the x, y, and z axes is less than 0.15 m. For a magnetic target with a depth of 1 m, the x-axis error is 0.15 m, the y-axis error is 0.05 m, and the z-axis error is 0.06 m. For a magnetic target with a depth of 0.7 m, the x-axis error is 0.08 m, the y-axis error is 0.12 m, and the z-axis error is 0.13 m.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Magnetic Multitarget Recognition Based on Magnetic Gradient Tensor
The difficulty in magnetic multi-target recognition is that it is difficult to recognize magnetic targets with different magnetic moments and different depths at the same time. This is because the magnetic moment and depth of a magnetic target affect the strength of the generated magnetic field information, resulting in localization results that favor targets that generate stronger magnetic fields, while targets with weaker magnetic fields cannot be accurately identified. In addition, the traditional Euler equation-based multi-target localization method requires calibration of the sensor array before detection, which requires high calibration accuracy as it relies on the inversion of mathematical equations to solve for magnetic targets. To address this problem, this paper proposes an inverse tangent function imaging processing method based on the magnetic gradient tensor information (MGT) depth direction change rate. The method aims to balance the differences in magnetic field information between different magnetic targets and enhance the recognition of the horizontal position of targets with weaker magnetic fields. Based on this, a depth detection method based on MGT is proposed to acquire the depth information of magnetic targets. A grid-format data acquisition method is also proposed to obtain the MGT. The method does not require calibration of the sensor array or separation of the magnetic anomaly field from the total field. Simulation and experimental results show that the positioning error of this method for each magnetic target in the x, y, and z axes is less than 0.15 m. For a magnetic target with a depth of 1 m, the x-axis error is 0.15 m, the y-axis error is 0.05 m, and the z-axis error is 0.06 m. For a magnetic target with a depth of 0.7 m, the x-axis error is 0.08 m, the y-axis error is 0.12 m, and the z-axis error is 0.13 m.
- 14 February 2025
- Published by Elsevier in Measurement
- Vol. 249
An in-field calibration method for magnetic array error
- 14 February 2025
- Published by Elsevier in Measurement
- Vol. 249
An in-field calibration method for magnetic array error
- Top Cited Papers
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 62 (01962892) , 1-11
Predictive Model-Based Correction of Magnetic Sensor Array Sway Errors
Magnetic sensor arrays are typically used to detect magnetic targets. Currently, research on sensor array calibration focuses on solving the problems of inconsistent sensitivity, zero offset, and non-orthogonality in individual sensors, and misalignment errors between sensors. However, in magnetic field detection, sensor arrays are usually mounted on a platform or carried as a handheld device and are prone to random swaying during the detection process, leading to changes in the attitude and position of the magnetic sensors, which in turn generates swaying errors. In this study, the source of swaying error in sensor arrays was first analyzed theoretically, and a swaying error model of a magnetic sensor was established. Second, an swaying error calibration method was proposed in combination with the classical prediction model— Gaussian Process Regression (GPR), Backpropagation Neural Network (BP) and Support Vector Machine (SVM) in the field of artificial intelligence. The experimental results show that the prediction performance based on the BP neural network is the most outstanding. After correction, the relative error percentage of the swaying error in the magnetic field data decreased significantly from 165.50% to 9.35%, which is a significant improvement of the correction effect. In addition, we conducted model comparison experiments in different environments, and the results show that the BP model performs well in various environments, demonstrating its strong generalization ability and robustness. Finally, the distance error of the magnetic dipole position was significantly reduced after calibration, from 1.56 m, 1.12 m, and 2.50 m to 0.17 m, 0.04 m, and 0.04 m, respectively. Thus, the effectiveness of the calibration method was verified.
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Geoscience and Remote Sensing
- Vol. 62 (01962892) , 1-11
Top Cited PapersPredictive Model-Based Correction of Magnetic Sensor Array Sway Errors
Magnetic sensor arrays are typically used to detect magnetic targets. Currently, research on sensor array calibration focuses on solving the problems of inconsistent sensitivity, zero offset, and non-orthogonality in individual sensors, and misalignment errors between sensors. However, in magnetic field detection, sensor arrays are usually mounted on a platform or carried as a handheld device and are prone to random swaying during the detection process, leading to changes in the attitude and position of the magnetic sensors, which in turn generates swaying errors. In this study, the source of swaying error in sensor arrays was first analyzed theoretically, and a swaying error model of a magnetic sensor was established. Second, an swaying error calibration method was proposed in combination with the classical prediction model— Gaussian Process Regression (GPR), Backpropagation Neural Network (BP) and Support Vector Machine (SVM) in the field of artificial intelligence. The experimental results show that the prediction performance based on the BP neural network is the most outstanding. After correction, the relative error percentage of the swaying error in the magnetic field data decreased significantly from 165.50% to 9.35%, which is a significant improvement of the correction effect. In addition, we conducted model comparison experiments in different environments, and the results show that the BP model performs well in various environments, demonstrating its strong generalization ability and robustness. Finally, the distance error of the magnetic dipole position was significantly reduced after calibration, from 1.56 m, 1.12 m, and 2.50 m to 0.17 m, 0.04 m, and 0.04 m, respectively. Thus, the effectiveness of the calibration method was verified.
- 12 February 2024
- Published by IOP Publishing in Modelling and Simulation in Materials Science and Engineering
- Vol. 32 (3) , 035006
Accurate and rapid predictions with explainable graph neural networks for small high-fidelity bandgap datasets
Accurate and rapid bandgap prediction is a fundamental task in materials science. We propose graph neural networks with transfer learning to overcome the scarcity of training data for high-fidelity bandgap predictions. We also add a perturbation-based component to our framework to improve explainability. The experimental results show that a framework consisting of graph-level pre-training and standard fine-tuning achieves superior performance on all high-fidelity bandgap prediction tasks and training-set sizes. Furthermore, the framework provides a reliable explanation that considers node features together with the graph structure. We also used the framework to screen 105 potential photovoltaic absorber materials.
- 12 February 2024
- Published by IOP Publishing in Modelling and Simulation in Materials Science and Engineering
- Vol. 32 (3) , 035006
Accurate and rapid predictions with explainable graph neural networks for small high-fidelity bandgap datasets
Accurate and rapid bandgap prediction is a fundamental task in materials science. We propose graph neural networks with transfer learning to overcome the scarcity of training data for high-fidelity bandgap predictions. We also add a perturbation-based component to our framework to improve explainability. The experimental results show that a framework consisting of graph-level pre-training and standard fine-tuning achieves superior performance on all high-fidelity bandgap prediction tasks and training-set sizes. Furthermore, the framework provides a reliable explanation that considers node features together with the graph structure. We also used the framework to screen 105 potential photovoltaic absorber materials.
- Open Access
- 6 April 2022
- Published by Wiley in Journal of Sensors
- Vol. 2022, 1-13
Correction of Three Sensors in a Magnetic Field Gradiometer
A magnetic sensor array is usually used for weak magnetic target detection. This paper presents a vector second-order gradiometer that is arranged in a vertical structure. The measurement accuracy of the gradiometer is affected by the error of each three-axis magnetometer (TAM) and the misalignment error between TAMs. By analyzing the error mechanism of the magnetic gradiometer test system, the corresponding error model for the correction of the gradient of the component is established. The error parameters of the gradiometer were estimated by the proposed method, and the gradient error of the magnetic field and the component gradient error of the magnetic field were corrected. After correction, the gradiometer is used to localize the magnetic target. Simulation results illustrate that the localization error of magnetic targets is reduced by two orders. Thus, this proposed correction method can effectively improve the locating performance of gradiometer.
- 6 April 2022
- Published by Wiley in Journal of Sensors
- Vol. 2022, 1-13
Open AccessCorrection of Three Sensors in a Magnetic Field Gradiometer
A magnetic sensor array is usually used for weak magnetic target detection. This paper presents a vector second-order gradiometer that is arranged in a vertical structure. The measurement accuracy of the gradiometer is affected by the error of each three-axis magnetometer (TAM) and the misalignment error between TAMs. By analyzing the error mechanism of the magnetic gradiometer test system, the corresponding error model for the correction of the gradient of the component is established. The error parameters of the gradiometer were estimated by the proposed method, and the gradient error of the magnetic field and the component gradient error of the magnetic field were corrected. After correction, the gradiometer is used to localize the magnetic target. Simulation results illustrate that the localization error of magnetic targets is reduced by two orders. Thus, this proposed correction method can effectively improve the locating performance of gradiometer.
- Open Access
Researching a Moving Target Detection Method Based on Magnetic Flux Induction Technology
The ocean is a very important arena in modern warfare where all marine powers deploy their military forces. Due to the complex environment of the ocean, underwater equipment has become a very threatening means of surprise attack in modern warfare. Therefore, the timely and effective detection of underwater moving targets is the key to obtaining warfare advantages and has important strategic significance for national security. In this paper, magnetic flux induction technology was studied with regard to the difficulty of detecting underwater concealed moving targets. Firstly, the characteristics of a magnetic target were analyzed and an equivalent magnetic dipole model was established. Secondly, the structure of the rectangular induction coil was designed according to the model, and the relationship between the target’s magnetism and the detection signal was deduced. The variation curves of the magnetic flux and the electromotive force induced in the coil were calculated by using the numerical simulation method, and the effects of the different motion parameters of the magnetic dipole and the size parameters of the coil on the induced electromotive force were analyzed. Finally, combined with the wavelet threshold filter, a series of field tests were carried out using ships of different materials in shallow water in order to verify the moving target detection method based on magnetic flux induction technology. The results showed that this method has an obvious response to moving targets and can effectively capture target signals, which verifies the feasibility of the magnetic flux induction detection technology.
Open AccessResearching a Moving Target Detection Method Based on Magnetic Flux Induction Technology
The ocean is a very important arena in modern warfare where all marine powers deploy their military forces. Due to the complex environment of the ocean, underwater equipment has become a very threatening means of surprise attack in modern warfare. Therefore, the timely and effective detection of underwater moving targets is the key to obtaining warfare advantages and has important strategic significance for national security. In this paper, magnetic flux induction technology was studied with regard to the difficulty of detecting underwater concealed moving targets. Firstly, the characteristics of a magnetic target were analyzed and an equivalent magnetic dipole model was established. Secondly, the structure of the rectangular induction coil was designed according to the model, and the relationship between the target’s magnetism and the detection signal was deduced. The variation curves of the magnetic flux and the electromotive force induced in the coil were calculated by using the numerical simulation method, and the effects of the different motion parameters of the magnetic dipole and the size parameters of the coil on the induced electromotive force were analyzed. Finally, combined with the wavelet threshold filter, a series of field tests were carried out using ships of different materials in shallow water in order to verify the moving target detection method based on magnetic flux induction technology. The results showed that this method has an obvious response to moving targets and can effectively capture target signals, which verifies the feasibility of the magnetic flux induction detection technology.
- Open Access
- 28 November 2014
- Published by Asian Pacific Organization for Cancer Prevention in Asian Pacific Journal of Cancer Prevention
- Vol. 15 (21) , 9375-9378
A Piezoelectric Immunosensor for Early Cervical Cancer Detection
A Piezoelectric Immunosensor for Early Cervical Cancer Detection Quartz crystal microbalance;immunosensor;early cervical cancer;detection; Background: A piezoelectric immunosensor for early cervical cancer detection was developed involving short analyis time and less invasive technique for $p16^{INK4a}$, a protein that has been linked to cervical cancer. Materials and Methods: $5{\mu}L$ of 5.0 mg/mL $p16^{INK4a}$ antibody and then supernatant from different clinical samples from West China Second University Hospital (Sichuan, China) were dripped on the center of the AT-cut crystal through a micro-injector. Absorption of the $p16^{INK4a}$ by antibody caused a shift in the resonant frequency of the immunosensor, and the resonant frequency was correlated to the amount of the $p16^{INK4a}$ in the supernatant. Results: The greater severity of lesion grading, the greater the expression level of $p16^{INK4a}$. Conclusion: Degree of cervical cancer lesion development could be determined by detected amount of $p16^{INK4a}$ in different clinical samples.- 28 November 2014
- Published by Asian Pacific Organization for Cancer Prevention in Asian Pacific Journal of Cancer Prevention
- Vol. 15 (21) , 9375-9378
Open AccessA Piezoelectric Immunosensor for Early Cervical Cancer Detection
A Piezoelectric Immunosensor for Early Cervical Cancer Detection Quartz crystal microbalance;immunosensor;early cervical cancer;detection; Background: A piezoelectric immunosensor for early cervical cancer detection was developed involving short analyis time and less invasive technique for $p16^{INK4a}$, a protein that has been linked to cervical cancer. Materials and Methods: $5{\mu}L$ of 5.0 mg/mL $p16^{INK4a}$ antibody and then supernatant from different clinical samples from West China Second University Hospital (Sichuan, China) were dripped on the center of the AT-cut crystal through a micro-injector. Absorption of the $p16^{INK4a}$ by antibody caused a shift in the resonant frequency of the immunosensor, and the resonant frequency was correlated to the amount of the $p16^{INK4a}$ in the supernatant. Results: The greater severity of lesion grading, the greater the expression level of $p16^{INK4a}$. Conclusion: Degree of cervical cancer lesion development could be determined by detected amount of $p16^{INK4a}$ in different clinical samples.