Mustafa Tamim Alam Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mustafa Tamim Alam Khan has a total of 98 co-authors. Here are the top co-authors by number of shared publications:
- Ronit Patnaik
Division of Transplant Surgery Johns Hopkins University School of Medicine Baltimore Maryland USA
10 shared publications - Christina S. Lee
Department of Surgery, Brooke Army Medical Center, San Antonio, USA
3 shared publications - Danielle Fritze
Department of Transplant Surgery, University of Texas Health San Antonio, San Antonio, USA
3 shared publications - Joao Bombardelli
UTHealth Houston, Division of Plastic Surgery, Houston, USA
3 shared publications Lisandro Montorfano
Department of Plastic Surgery Vanderbilt University Nashville Tennessee USA
3 shared publications- Robert B. Laverty
Department of Surgery, Brooke Army Medical Center, San Antonio, USA
3 shared publications
Latest Publications
- Open Access
- 19 November 2026
- Published by Springer Nature in Global Surgical Education - Journal of the Association for Surgical Education
- Vol. 5 (1)
AI through the looking glass: a controlled feasibility study of wearable AI assistance on plastic surgery in-service examination questions
Purpose: Large language models (LLMs) have demonstrated substantial accuracy on specialty in-service examinations. Commercially available smart glasses now make real-time AI assistance wearable, raising concerns about testing integrity. We developed and evaluated a smart glasses application that captures an examination question, submits it to an AI model, and delivers the answer directly to the wearer, to assess the feasibility and limitations of this workflow in a controlled simulation. Methods: In Phase 1, three LLMs (Google Gemini 2.5 Flash, OpenAI GPT-4o, and Anthropic Claude Sonnet 4.6) and a majority-vote ensemble were benchmarked on 743 Plastic Surgery In-Service Training Examination (PSITE) question texts from the 2021–2023 examination cycles. Clinical images were not supplied. In Phase 2, the model with the highest observed accuracy was deployed through Rokid AI Glasses, a companion phone, and a cloud service. One study author tested the system on a 50-question subset selected from Phase 1. Outcomes were accuracy, first-attempt success, eventual completion, and successful-attempt latency. Results: Gemini 2.5 Flash achieved the highest individual accuracy (82.8%), followed by Claude Sonnet 4.6 (80.9%) and GPT-4o (76.9%). The majority-vote ensemble achieved 81.6% accuracy and did not outperform Gemini. In Phase 2, the wearable system answered 76.0% of questions correctly (38/50; 95% CI, 62.6%–85.7%). Answers were returned on the first attempt for 45/50 questions (90.0%); all 50 were completed after 56 attempts. Six attempts failed because of application timeouts requiring restart. Mean successful-attempt latency was 8.9 s (SD 4.2), excluding failed attempts and restart time. Conclusions: Commercially available smart glasses and AI services can be connected into a workflow that answers plastic surgery examination questions in real time, although errors and retries limit reliability. This controlled simulation illustrates a potential route to unauthorized assistance. The findings aim to encourage broader discussion of emerging risks to testing integrity and the future of education and assessment.
- 19 November 2026
- Published by Springer Nature in Global Surgical Education - Journal of the Association for Surgical Education
- Vol. 5 (1)
Open AccessAI through the looking glass: a controlled feasibility study of wearable AI assistance on plastic surgery in-service examination questions
Purpose: Large language models (LLMs) have demonstrated substantial accuracy on specialty in-service examinations. Commercially available smart glasses now make real-time AI assistance wearable, raising concerns about testing integrity. We developed and evaluated a smart glasses application that captures an examination question, submits it to an AI model, and delivers the answer directly to the wearer, to assess the feasibility and limitations of this workflow in a controlled simulation. Methods: In Phase 1, three LLMs (Google Gemini 2.5 Flash, OpenAI GPT-4o, and Anthropic Claude Sonnet 4.6) and a majority-vote ensemble were benchmarked on 743 Plastic Surgery In-Service Training Examination (PSITE) question texts from the 2021–2023 examination cycles. Clinical images were not supplied. In Phase 2, the model with the highest observed accuracy was deployed through Rokid AI Glasses, a companion phone, and a cloud service. One study author tested the system on a 50-question subset selected from Phase 1. Outcomes were accuracy, first-attempt success, eventual completion, and successful-attempt latency. Results: Gemini 2.5 Flash achieved the highest individual accuracy (82.8%), followed by Claude Sonnet 4.6 (80.9%) and GPT-4o (76.9%). The majority-vote ensemble achieved 81.6% accuracy and did not outperform Gemini. In Phase 2, the wearable system answered 76.0% of questions correctly (38/50; 95% CI, 62.6%–85.7%). Answers were returned on the first attempt for 45/50 questions (90.0%); all 50 were completed after 56 attempts. Six attempts failed because of application timeouts requiring restart. Mean successful-attempt latency was 8.9 s (SD 4.2), excluding failed attempts and restart time. Conclusions: Commercially available smart glasses and AI services can be connected into a workflow that answers plastic surgery examination questions in real time, although errors and retries limit reliability. This controlled simulation illustrates a potential route to unauthorized assistance. The findings aim to encourage broader discussion of emerging risks to testing integrity and the future of education and assessment.
- Open Access
- 17 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1)
Surgical Intelligence Labs: a technical feasibility study of smartphone-based egocentric data capture and computational retargeting for robotic surgery
- 17 November 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1)
Open AccessSurgical Intelligence Labs: a technical feasibility study of smartphone-based egocentric data capture and computational retargeting for robotic surgery
- 27 August 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 894
Embodied AI in the operating room: a voice-interactive robotic scrub nurse for surgical instrument handoffs
Embodied artificial intelligence may extend surgical robotics beyond teleoperation by enabling robots to interpret natural-language commands, perceive dynamic environments, and generate adaptive physical actions. Surgical instrument exchange provides a clinically recognizable test case requiring communication, visual localization, dexterity, and bidirectional interaction. We developed a voice-interactive robotic scrub nurse through task-specific adaptation of the pretrained π0.5 vision-language-action model capable of voice-conditioned surgical instrument handoff, take-back, and spoken acknowledgment. A bimanual robotic platform was trained by fine-tuning the pretrained π0.5 model on 350 human-teleoperated demonstrations. The system integrated real-time multicamera observations, Whisper large-v2 speech recognition, language-conditioned robotic action generation, and text-to-speech acknowledgment. Performance was evaluated in 100 autonomous trials across five tasks: needle-driver handoff, forceps handoff, needle-and-suture handoff, needle-driver take-back, and forceps take-back. Each task included 10 trials using spatial configurations represented during training and 10 trials using held-out spatial configurations within the same environment. Outcomes included command interpretation, stage-wise completion, end-to-end success, completion time, and failure mode. Recovery after interference was examined qualitatively in separate representative demonstrations. The system completed 81% of trials successfully. Success was 95% for both take-back tasks, 85% for forceps handoff, 80% for needle-driver handoff, and 50% for needle-and-suture handoff. Performance decreased from 92% in seen layouts to 70% in held-out layouts. Speech-command interpretation succeeded in 99% of trials. Once a secure grasp was achieved, downstream manipulation succeeded in 81 of 82 trials. Missed grasp was the predominant failure mode. A unified learned policy enabled voice-conditioned bidirectional surgical instrument exchange and demonstrated meaningful generalization to held-out layouts within the same environment. Improved grasp acquisition, expanded instrument diversity, quantitative recovery testing, and evaluation in realistic operating-room workflows are required before clinical translation or integration with complete back-table workflows.
- 27 August 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 894
Embodied AI in the operating room: a voice-interactive robotic scrub nurse for surgical instrument handoffs
Embodied artificial intelligence may extend surgical robotics beyond teleoperation by enabling robots to interpret natural-language commands, perceive dynamic environments, and generate adaptive physical actions. Surgical instrument exchange provides a clinically recognizable test case requiring communication, visual localization, dexterity, and bidirectional interaction. We developed a voice-interactive robotic scrub nurse through task-specific adaptation of the pretrained π0.5 vision-language-action model capable of voice-conditioned surgical instrument handoff, take-back, and spoken acknowledgment. A bimanual robotic platform was trained by fine-tuning the pretrained π0.5 model on 350 human-teleoperated demonstrations. The system integrated real-time multicamera observations, Whisper large-v2 speech recognition, language-conditioned robotic action generation, and text-to-speech acknowledgment. Performance was evaluated in 100 autonomous trials across five tasks: needle-driver handoff, forceps handoff, needle-and-suture handoff, needle-driver take-back, and forceps take-back. Each task included 10 trials using spatial configurations represented during training and 10 trials using held-out spatial configurations within the same environment. Outcomes included command interpretation, stage-wise completion, end-to-end success, completion time, and failure mode. Recovery after interference was examined qualitatively in separate representative demonstrations. The system completed 81% of trials successfully. Success was 95% for both take-back tasks, 85% for forceps handoff, 80% for needle-driver handoff, and 50% for needle-and-suture handoff. Performance decreased from 92% in seen layouts to 70% in held-out layouts. Speech-command interpretation succeeded in 99% of trials. Once a secure grasp was achieved, downstream manipulation succeeded in 81 of 82 trials. Missed grasp was the predominant failure mode. A unified learned policy enabled voice-conditioned bidirectional surgical instrument exchange and demonstrated meaningful generalization to held-out layouts within the same environment. Improved grasp acquisition, expanded instrument diversity, quantitative recovery testing, and evaluation in realistic operating-room workflows are required before clinical translation or integration with complete back-table workflows.
- Open Access
- 10 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (41) , eadx9917
Ligand-receptor interactions induce and mediate regulatory functions of BATF3 + B cells
B cells express many protein ligands, yet their regulatory functions are incompletely understood. We profiled ligand expression across murine B sublineage cells, including those activated by defined receptor signals, and assessed their regulatory capacities and specificities through in silico analysis of ligand-receptor interactions. Consequently, we identified a B cell subset that expressed cytokine interleukin-27 (IL-27) and chemokine CXCL10. Through the IL-27–IL-27 receptor interaction, these IL-27/CXCL10-producing B cells targeted CD40-activated B cells in vitro and, upon induction by immunization and viral infection, optimized antibody responses and antiviral immunity in vivo. Also present in breast cancer tumors and retained there through CXCL10-CXCR3 interaction–mediated self-targeting, these cells promoted B cell PD-L1 expression and immune evasion. Mechanistically, Il27 and Cxcl10 transcription was induced by synergizing Toll-like receptor (TLR) and CD40 signals and driven by coinduced transcription factor BATF3, which directly targeted these genes. By applying a discovery framework focusing on regulatory cells, our findings expand the recognized scope of B cell regulatory functions.
- 10 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (41) , eadx9917
Open AccessLigand-receptor interactions induce and mediate regulatory functions of BATF3 + B cells
B cells express many protein ligands, yet their regulatory functions are incompletely understood. We profiled ligand expression across murine B sublineage cells, including those activated by defined receptor signals, and assessed their regulatory capacities and specificities through in silico analysis of ligand-receptor interactions. Consequently, we identified a B cell subset that expressed cytokine interleukin-27 (IL-27) and chemokine CXCL10. Through the IL-27–IL-27 receptor interaction, these IL-27/CXCL10-producing B cells targeted CD40-activated B cells in vitro and, upon induction by immunization and viral infection, optimized antibody responses and antiviral immunity in vivo. Also present in breast cancer tumors and retained there through CXCL10-CXCR3 interaction–mediated self-targeting, these cells promoted B cell PD-L1 expression and immune evasion. Mechanistically, Il27 and Cxcl10 transcription was induced by synergizing Toll-like receptor (TLR) and CD40 signals and driven by coinduced transcription factor BATF3, which directly targeted these genes. By applying a discovery framework focusing on regulatory cells, our findings expand the recognized scope of B cell regulatory functions.
- 18 July 2023
- Published by Wiley in Microsurgery
- Vol. 43 (7) , 657-664
Evaluation of modified frailty index for predicting post‐operative outcomes after lower‐extremity free‐flap reconstruction
Background: Risk stratification for complex procedures such as microsurgical reconstruction of the lower extremities is an important part of preoperative planning and counseling. The aim of this study was to determine the effectiveness of the modified five‐item frailty index (5‐mFI) score, a validated tool for assessing risk in surgical patients, in predicting postoperative complications after lower extremity (LE) free flap reconstruction.Methods: A retrospective review of the American College of Surgeons National Surgical Quality Improvement Program (ACS‐NSQIP) database was conducted from 2010 to 2020 on patients who underwent LE free‐flap reconstruction. 5‐mFI scores were calculated and patients were categorized as 5‐mFI ≥2 or p = .043) and hematologic complications (p = .033). In this population, there were also higher rates of reoperation (p = .003) and discharge to care facility (p < .001). Multivariable regression models further substantiated that 5‐mFI ≥2 was independently associated with increased overall complications [2.46, CI: 1.10–5.59, p = .031], hematologic complications [2.55, 1.02–6.35, p = .046], reoperation [4.55, 1.54–13.3, p = .006], and discharge to facility [2.86, 1.27–6.45, p = .011].Conclusions: There is a strong association of 5‐mFI ≥2 with adverse post‐operative outcomes in male patients undergoing LE free‐flap reconstruction. This can be a valuable adjunct in the counsel of patients for whom lower extremity salvage is feasible.
- 18 July 2023
- Published by Wiley in Microsurgery
- Vol. 43 (7) , 657-664
Evaluation of modified frailty index for predicting post‐operative outcomes after lower‐extremity free‐flap reconstruction
Background: Risk stratification for complex procedures such as microsurgical reconstruction of the lower extremities is an important part of preoperative planning and counseling. The aim of this study was to determine the effectiveness of the modified five‐item frailty index (5‐mFI) score, a validated tool for assessing risk in surgical patients, in predicting postoperative complications after lower extremity (LE) free flap reconstruction.Methods: A retrospective review of the American College of Surgeons National Surgical Quality Improvement Program (ACS‐NSQIP) database was conducted from 2010 to 2020 on patients who underwent LE free‐flap reconstruction. 5‐mFI scores were calculated and patients were categorized as 5‐mFI ≥2 or p = .043) and hematologic complications (p = .033). In this population, there were also higher rates of reoperation (p = .003) and discharge to care facility (p < .001). Multivariable regression models further substantiated that 5‐mFI ≥2 was independently associated with increased overall complications [2.46, CI: 1.10–5.59, p = .031], hematologic complications [2.55, 1.02–6.35, p = .046], reoperation [4.55, 1.54–13.3, p = .006], and discharge to facility [2.86, 1.27–6.45, p = .011].Conclusions: There is a strong association of 5‐mFI ≥2 with adverse post‐operative outcomes in male patients undergoing LE free‐flap reconstruction. This can be a valuable adjunct in the counsel of patients for whom lower extremity salvage is feasible.
- 23 May 2023
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 17 (5) , 2109-2115
Intentional enterotomies: validation of a novel robotic surgery training exercise
While laparoscopic simulation-based training is a well-established component of general surgery training, no such requirement or standardized curriculum exists for robotic surgery. Furthermore, there is a lack of high-fidelity electrocautery simulation training exercises in the literature. Using Messick’s validity framework, we sought to determine the content, response process, internal content and construct validity of a novel inanimate tissue model that utilizes electrocautery for potential incorporation in such curricula. A multi-institutional, prospective study involving medical students (MS) and general surgery residents (PGY1-3) was conducted. Participants performed an exercise using a biotissue bowel model on the da Vinci Xi robotic console during which they created an enterotomy using electrocautery, followed by approximation with interrupted sutures. Participant performance was recorded and then scored by crowd-sourced assessors of technical skill, along with three of the authors. Construct validity was determined via difference in Global Evaluative Assessment of Robotic Skills (GEARS) score, time to completion, and total number of errors between the two cohorts. Upon completion of the exercise, participants were surveyed on their perception of the exercise and its impact on their robotic training to determine content validity. 31 participants were enrolled and separated into two cohorts: MS + PGY1 vs. PGY2-3. Time spent on the robotic trainer (0.8 vs. 8.13 h, p = 0.002), number of bedside robotic assists (5.7 vs. 14.8, p < 0.001), and number of robotic cases as primary surgeon (0.3 vs. 13.1, p < 0.001) were statistically significant between the two groups. Differences in GEARS scores (18.5 vs. 19.9, p = 0.001), time to completion (26.1 vs. 14.4 min, p < 0.001), and total errors (21.5 vs. 11.9, p = 0.018) between the groups were statistically significant as well. Of the 23 participants that completed the post-exercise survey, 87% and 91.3% reported improvement in robotic surgical ability and confidence, respectively. On a 10-point Likert scale, respondents rated the realism of the exercise 7.5, educational benefit 9.1, and effectiveness in teaching robotic skills 8.7. Controlling for the upfront investment of certain training materials, each exercise iteration cost ~ $30. This study confirmed the content, response process, internal structure and construct validity of a novel, high-fidelity and cost-effective inanimate tissue exercise which successfully incorporates electrocautery. Consideration should be given to its addition to robotic surgery training programs.
- 23 May 2023
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 17 (5) , 2109-2115
Intentional enterotomies: validation of a novel robotic surgery training exercise
While laparoscopic simulation-based training is a well-established component of general surgery training, no such requirement or standardized curriculum exists for robotic surgery. Furthermore, there is a lack of high-fidelity electrocautery simulation training exercises in the literature. Using Messick’s validity framework, we sought to determine the content, response process, internal content and construct validity of a novel inanimate tissue model that utilizes electrocautery for potential incorporation in such curricula. A multi-institutional, prospective study involving medical students (MS) and general surgery residents (PGY1-3) was conducted. Participants performed an exercise using a biotissue bowel model on the da Vinci Xi robotic console during which they created an enterotomy using electrocautery, followed by approximation with interrupted sutures. Participant performance was recorded and then scored by crowd-sourced assessors of technical skill, along with three of the authors. Construct validity was determined via difference in Global Evaluative Assessment of Robotic Skills (GEARS) score, time to completion, and total number of errors between the two cohorts. Upon completion of the exercise, participants were surveyed on their perception of the exercise and its impact on their robotic training to determine content validity. 31 participants were enrolled and separated into two cohorts: MS + PGY1 vs. PGY2-3. Time spent on the robotic trainer (0.8 vs. 8.13 h, p = 0.002), number of bedside robotic assists (5.7 vs. 14.8, p < 0.001), and number of robotic cases as primary surgeon (0.3 vs. 13.1, p < 0.001) were statistically significant between the two groups. Differences in GEARS scores (18.5 vs. 19.9, p = 0.001), time to completion (26.1 vs. 14.4 min, p < 0.001), and total errors (21.5 vs. 11.9, p = 0.018) between the groups were statistically significant as well. Of the 23 participants that completed the post-exercise survey, 87% and 91.3% reported improvement in robotic surgical ability and confidence, respectively. On a 10-point Likert scale, respondents rated the realism of the exercise 7.5, educational benefit 9.1, and effectiveness in teaching robotic skills 8.7. Controlling for the upfront investment of certain training materials, each exercise iteration cost ~ $30. This study confirmed the content, response process, internal structure and construct validity of a novel, high-fidelity and cost-effective inanimate tissue exercise which successfully incorporates electrocautery. Consideration should be given to its addition to robotic surgery training programs.
- 20 May 2023
- Published by Elsevier in Journal of Surgical Education
- Vol. 80 (11) , 1602-1607
The “Intern” Label: Introducing Unnecessary Confusion and Bias?
- 20 May 2023
- Published by Elsevier in Journal of Surgical Education
- Vol. 80 (11) , 1602-1607
The “Intern” Label: Introducing Unnecessary Confusion and Bias?
- 20 March 2023
- Published by Elsevier in Journal of Surgical Research
- Vol. 288, 43-50
Gender Discrepancies in Middle Author Publications in US Academic General Surgery
- 20 March 2023
- Published by Elsevier in Journal of Surgical Research
- Vol. 288, 43-50
Gender Discrepancies in Middle Author Publications in US Academic General Surgery
- Open Access
- 7 March 2023
- Published by Springer Nature in Research Square
Intentional Enterotomies: Validation of a Novel Robotic Surgery Training Exercise
Purpose: While laparoscopic simulation-based training is a well-established component of general surgery training, no such requirement or standardized curriculum exists for robotic surgery. Furthermore, there is a lack of high-fidelity electrocautery simulation training exercises in the literature. Using Messick’s validity framework, we sought to determine the content, response process, internal content and construct validity of a novel inanimate tissue model that utilizes electrocautery for potential incorporation in such curricula. Methods: Multi-institutional, prospective study involving medical students (MS) and general surgery residents (PGY1-3). Participants performed an exercise using a biotissue bowel model on the da Vinci Xi robotic console during which they created an enterotomy using electrocautery followed by approximation with interrupted sutures. Participant performance was recorded and then scored by crowd-sourced assessors of technical skill along with three of the authors. Construct validity was determined via difference in Global Evaluative Assessment of Robotic Skills (GEARS) score, time to completion and total number of errors between the two cohorts. Upon completion of the exercise, participants were surveyed on their perception of the exercise and its impact on their robotic training to determine content validity. Results: 31 participants were enrolled and separated into two cohorts: MS + PGY1 vs PGY2-3. Time spent on the robotic trainer (0.8 vs 8.13 hours, p=0.002), number of bedside robotic assists (5.7 vs 14.8, pConclusions: This study confirmed the content, response process, internal structure and construct validity of a novel, high-fidelity and cost-effective inanimate tissue exercise which successfully incorporates electrocautery. Consideration should be given to its addition to robotic surgery training programs.
- 7 March 2023
- Published by Springer Nature in Research Square
Open AccessIntentional Enterotomies: Validation of a Novel Robotic Surgery Training Exercise
Purpose: While laparoscopic simulation-based training is a well-established component of general surgery training, no such requirement or standardized curriculum exists for robotic surgery. Furthermore, there is a lack of high-fidelity electrocautery simulation training exercises in the literature. Using Messick’s validity framework, we sought to determine the content, response process, internal content and construct validity of a novel inanimate tissue model that utilizes electrocautery for potential incorporation in such curricula. Methods: Multi-institutional, prospective study involving medical students (MS) and general surgery residents (PGY1-3). Participants performed an exercise using a biotissue bowel model on the da Vinci Xi robotic console during which they created an enterotomy using electrocautery followed by approximation with interrupted sutures. Participant performance was recorded and then scored by crowd-sourced assessors of technical skill along with three of the authors. Construct validity was determined via difference in Global Evaluative Assessment of Robotic Skills (GEARS) score, time to completion and total number of errors between the two cohorts. Upon completion of the exercise, participants were surveyed on their perception of the exercise and its impact on their robotic training to determine content validity. Results: 31 participants were enrolled and separated into two cohorts: MS + PGY1 vs PGY2-3. Time spent on the robotic trainer (0.8 vs 8.13 hours, p=0.002), number of bedside robotic assists (5.7 vs 14.8, pConclusions: This study confirmed the content, response process, internal structure and construct validity of a novel, high-fidelity and cost-effective inanimate tissue exercise which successfully incorporates electrocautery. Consideration should be given to its addition to robotic surgery training programs.
- Open Access
- 22 December 2022
- Published by Wiley in Colorectal Disease
- Vol. 25 (4) , 717-727
Leukopenia is an independent risk factor for early postoperative complications following incision and drainage of anorectal abscess
Aim: Few data are available regarding the management of anorectal abscess in patients with leukopenia. The aim of this study was to investigate the impact of leukopenia among patients undergoing incision and drainage for anorectal abscess.Method: A retrospective review of the American College of Surgeons National Surgical Quality Improvement Program (ACS‐NSQIP) database identified patients from 2015 to 2020. Perianal fistulas and supralevator abscesses were excluded. Patients were grouped based on white blood cell (WBC) count: WBC < 4.5 cells/μl, WBC = 4.5–11.0 cells/μl and WBC > 11.0 cells/μl. The 30‐day overall complications and outcomes were compared using regression models, accounting for demographics and comorbidities.Results: Ten thousand two hundred and forty (70.3% male) patients were identified. Univariate analysis showed that, compared with patients with leukocytosis (WBC > 11.0 cells/μl) and normal WBC count (WBC = 4.5–11.0 cells/μl), patients with leukopenia (WBC p < 0.001), pulmonary (p < 0.001) and haematological complications (p < 0.001). They also had higher rates of readmission (p < 0.001), reoperation (p = 0.005), discharge to a care facility (p = 0.003), increased length of hospital stay (p = 0.004) and death (p < 0.001). Multivariable analysis identified leukopenia as an independent risk factor for overall complications [odds ratio (OR) 2.31, 95% CI 1.65–3.24; p < 0.001], pulmonary complications (OR 5.65, 95% CI 1.88–16.97; p = 0.002), haematological complications (OR 4.30, 95% CI 2.94–6.28; p < 0.001), unplanned readmission (OR 2.20, 95% CI 1.43–3.40; p < 0.001), reoperation (OR 1.80, 95% CI 1.10–2.93; p = 0.019) and death (OR 2.77, 95% CI 1.02–7.52; p = 0.046). Discharge to a care facility and length of stay were not significant on multivariable analysis.Conclusion: Leukopenia is associated with increased risk for pulmonary and haematological complications, readmissions, reoperations, discharge to a care facility and death after incision and drainage for anorectal abscess.
- 22 December 2022
- Published by Wiley in Colorectal Disease
- Vol. 25 (4) , 717-727
Open AccessLeukopenia is an independent risk factor for early postoperative complications following incision and drainage of anorectal abscess
Aim: Few data are available regarding the management of anorectal abscess in patients with leukopenia. The aim of this study was to investigate the impact of leukopenia among patients undergoing incision and drainage for anorectal abscess.Method: A retrospective review of the American College of Surgeons National Surgical Quality Improvement Program (ACS‐NSQIP) database identified patients from 2015 to 2020. Perianal fistulas and supralevator abscesses were excluded. Patients were grouped based on white blood cell (WBC) count: WBC < 4.5 cells/μl, WBC = 4.5–11.0 cells/μl and WBC > 11.0 cells/μl. The 30‐day overall complications and outcomes were compared using regression models, accounting for demographics and comorbidities.Results: Ten thousand two hundred and forty (70.3% male) patients were identified. Univariate analysis showed that, compared with patients with leukocytosis (WBC > 11.0 cells/μl) and normal WBC count (WBC = 4.5–11.0 cells/μl), patients with leukopenia (WBC p < 0.001), pulmonary (p < 0.001) and haematological complications (p < 0.001). They also had higher rates of readmission (p < 0.001), reoperation (p = 0.005), discharge to a care facility (p = 0.003), increased length of hospital stay (p = 0.004) and death (p < 0.001). Multivariable analysis identified leukopenia as an independent risk factor for overall complications [odds ratio (OR) 2.31, 95% CI 1.65–3.24; p < 0.001], pulmonary complications (OR 5.65, 95% CI 1.88–16.97; p = 0.002), haematological complications (OR 4.30, 95% CI 2.94–6.28; p < 0.001), unplanned readmission (OR 2.20, 95% CI 1.43–3.40; p < 0.001), reoperation (OR 1.80, 95% CI 1.10–2.93; p = 0.019) and death (OR 2.77, 95% CI 1.02–7.52; p = 0.046). Discharge to a care facility and length of stay were not significant on multivariable analysis.Conclusion: Leukopenia is associated with increased risk for pulmonary and haematological complications, readmissions, reoperations, discharge to a care facility and death after incision and drainage for anorectal abscess.