E.N. Bolbasov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
E.N. Bolbasov has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- A.D. Koniaeva
Siberian State Medical University, Tomsk, Russia
4 shared publications - E. Yu. Varakuta
Siberian State Medical University, Tomsk, Russia
4 shared publications - A.E. Leiman
Siberian State Medical University, Tomsk, Russia
3 shared publications - Ksenia Sergeevna Stankevich
Montana State University, Bozeman, MT, USA
2 shared publications - U.V. Chernova
National Research Tomsk Polytechnic University, Tomsk, Russia
2 shared publications - A. V. Gerasimov
Siberian State Medical University
1 shared publication
Latest Publications
- 1 January 2026
- Published by FSBSI Research Institute of Human Morphology in CLINICAL AND EXPERIMENTAL MORPHOLOGY
- Vol. 15 (5)
Morphological characteristics of the microcirculatory network in regenerating purulent wounds with piezoelectric polymer smart membranes
Introduction. Purulent oral wounds are associated with marked microcirculatory disturbances that impair tissue regeneration. Therefore, wound coverings that restore the vascular component are of particular interest. This study evaluated morphological changes in the microcirculatory network during regeneration of purulent oral wounds treated with antibacterial piezoelectric polymer smart membranes. Materials and methods. Sixty Wistar rats were divided into four groups (n=15 each): untreated purulent wounds, smart membranes without an antibacterial layer, smart membranes with an antibacterial layer, and intact controls. On days 3, 7, and 14, we assessed the Kernohan index, pericapillary diffusion index, arteriolar-venular ratio, numerical density of altered arterioles and venules, VEGF expression, and endothelial ultrastructure. Results. Early inflammation-associated microcirculatory disturbances occurred in all wound groups. Membrane-treated groups showed partial microcirculatory recovery by day 7. On day 14, VEGF expression in groups 2 and 3 was 2.8- and 5.8-fold higher, respectively than in the untreated group (p=0.0287 and p=0.0001). In group 3, most parameters approached intact-control values. In the untreated group, however, the Kernohan index remained 1.5-fold higher (p=0.0027) and the arteriolar-venular ratio 1.3-fold lower (p=0.0035) than in intact controls, with numerous altered arterioles and venules. Conclusion. Antibacterial piezoelectric polymer smart membranes promoted angiogenic activity and accelerated restoration of the microcirculatory network in purulent oral wounds, with near-normalization of most parameters by day 14. Keywords: purulent wound, smart materials, regeneration, piezoelectrics, microcirculation
- 1 January 2026
- Published by FSBSI Research Institute of Human Morphology in CLINICAL AND EXPERIMENTAL MORPHOLOGY
- Vol. 15 (5)
Morphological characteristics of the microcirculatory network in regenerating purulent wounds with piezoelectric polymer smart membranes
Introduction. Purulent oral wounds are associated with marked microcirculatory disturbances that impair tissue regeneration. Therefore, wound coverings that restore the vascular component are of particular interest. This study evaluated morphological changes in the microcirculatory network during regeneration of purulent oral wounds treated with antibacterial piezoelectric polymer smart membranes. Materials and methods. Sixty Wistar rats were divided into four groups (n=15 each): untreated purulent wounds, smart membranes without an antibacterial layer, smart membranes with an antibacterial layer, and intact controls. On days 3, 7, and 14, we assessed the Kernohan index, pericapillary diffusion index, arteriolar-venular ratio, numerical density of altered arterioles and venules, VEGF expression, and endothelial ultrastructure. Results. Early inflammation-associated microcirculatory disturbances occurred in all wound groups. Membrane-treated groups showed partial microcirculatory recovery by day 7. On day 14, VEGF expression in groups 2 and 3 was 2.8- and 5.8-fold higher, respectively than in the untreated group (p=0.0287 and p=0.0001). In group 3, most parameters approached intact-control values. In the untreated group, however, the Kernohan index remained 1.5-fold higher (p=0.0027) and the arteriolar-venular ratio 1.3-fold lower (p=0.0035) than in intact controls, with numerous altered arterioles and venules. Conclusion. Antibacterial piezoelectric polymer smart membranes promoted angiogenic activity and accelerated restoration of the microcirculatory network in purulent oral wounds, with near-normalization of most parameters by day 14. Keywords: purulent wound, smart materials, regeneration, piezoelectrics, microcirculation
- 1 January 2025
- Published by FSBSI Research Institute of Human Morphology in CLINICAL AND EXPERIMENTAL MORPHOLOGY
- Vol. 14 (4)
Biointegration of barrier membranes with different microstructures in hernia repair: preliminary assessment of morphological aspects
Introduction.It is key to create barrier meshes to prevent adhesive disease and strengthen the anterior abdominal wall during hernioplasty. A promising material for it may be a polymer based on vinylidene fluoride and tetrafluoroethylene (VDF-TeFE). We aimed to do a preliminary assessment of morphological aspects of biointegrating VDF-TeFE meshes with various microstructures during hernioplasty, with the most effective one to be later improved for a full preclinical study. Materials and methods. The research was performed on 40 Chinchilla rabbits divided into 4 equal groups: group 1 underwent laparotomy without mesh implantation, the animals from groups 2–4 received a VDF-TeFE mesh barrier having different microstructures. Results. The 1.9-mm pore size (group 2) promoted the formation of dense connective tissue and the growth of adhesions between the organs, the mesh, and the anterior abdominal wall. Pores with a 0.9-mm diameter (group 3) prevented the formation of adhesions, but did not contribute to the strengthening of the anterior abdominal wall. The hybrid mesh structure (group 4) was the most effective because it prevented recurrence of anterior abdominal wall hernia and contributed to a decrease in the formation of adhesions between intestinal loops and the endoprosthesis. Conclusion.The barrier meshes of a hybrid structure made from VDF-TeFE are promising in hernioplasty to prevent adhesions and hernia recurrence. Further work needs to improve the endoprosthesis by modifying it with drugs that prevent the formation of adhesions. However, this issue requires a more in-depth study. Keywords: biointegration, biopolymers, chronic inflammation, adhesive disease, hernia repair, copolymer of tetrafluoroethylene with vinylidene fluoride (VDF-TeFE)
- 1 January 2025
- Published by FSBSI Research Institute of Human Morphology in CLINICAL AND EXPERIMENTAL MORPHOLOGY
- Vol. 14 (4)
Biointegration of barrier membranes with different microstructures in hernia repair: preliminary assessment of morphological aspects
Introduction.It is key to create barrier meshes to prevent adhesive disease and strengthen the anterior abdominal wall during hernioplasty. A promising material for it may be a polymer based on vinylidene fluoride and tetrafluoroethylene (VDF-TeFE). We aimed to do a preliminary assessment of morphological aspects of biointegrating VDF-TeFE meshes with various microstructures during hernioplasty, with the most effective one to be later improved for a full preclinical study. Materials and methods. The research was performed on 40 Chinchilla rabbits divided into 4 equal groups: group 1 underwent laparotomy without mesh implantation, the animals from groups 2–4 received a VDF-TeFE mesh barrier having different microstructures. Results. The 1.9-mm pore size (group 2) promoted the formation of dense connective tissue and the growth of adhesions between the organs, the mesh, and the anterior abdominal wall. Pores with a 0.9-mm diameter (group 3) prevented the formation of adhesions, but did not contribute to the strengthening of the anterior abdominal wall. The hybrid mesh structure (group 4) was the most effective because it prevented recurrence of anterior abdominal wall hernia and contributed to a decrease in the formation of adhesions between intestinal loops and the endoprosthesis. Conclusion.The barrier meshes of a hybrid structure made from VDF-TeFE are promising in hernioplasty to prevent adhesions and hernia recurrence. Further work needs to improve the endoprosthesis by modifying it with drugs that prevent the formation of adhesions. However, this issue requires a more in-depth study. Keywords: biointegration, biopolymers, chronic inflammation, adhesive disease, hernia repair, copolymer of tetrafluoroethylene with vinylidene fluoride (VDF-TeFE)
- 1 January 2022
- Published by FSBSI Research Institute of Human Morphology in CLINICAL AND EXPERIMENTAL MORPHOLOGY
- Vol. 11 (3)
Restoration of the microvasculature and hemodynamics in the oral mucosa wound defects area with and without a piezoelectric polymer membrane
Introduction. Restoration of blood supply to tissues is crucial for the regeneration of wound defects. The purpose of this research was to study the effect of piezoelectric polymers on the restoration of microcirculation and hemodynamics in the area of oral mucosa wound defects. Materials and methods. The study was carried out on 60 Wistar rats divided into four groups (15 rats each): control (intact) and 3 experimental groups. In group 1, the animals had an open wound defect. In groups 3 and 2, the rats had a wound defect covered with a membrane with and without copper modification, respectively. The specimens for subsequent light and electron microscopy were collected on days 3, 7, and 12. We studied qualitative and quantitative indicators of microcirculation and hemodynamics restoration. Results. Day 3: in all experimental groups, the arteriolo-venular relationship and the pericapillary diffusion index significantly decreased, while the Kernogan index increased. We also observed a significant increase in VEGF expression. Day 7: in experimental group 3, the values of the Kernogan index and the arteriolo-venular relationship were restored, and the pericapillary diffusion index remained significantly higher than in the control group. In the groups 1 and 2, none of the indicators reached the control values. VEGF expression decreased in all groups. On day 12 in group 1, the arteriolo-venular relationship, the Kernogan index and the index of pericapillary diffusion differed from the control group, in contrast to groups 2 and 3, where all the studied parameters were restored. Expression of VEGF in group 1 was significantly less than the control values, and in groups 2 and 3 it was significantly higher. Conclusion. We revealed that closing of oral mucosa wound defects by a piezoelectric polymer membrane led to the restoration of hemodynamic parameters and promoted active vascular formation. Keywords: wound defect, oral cavity, inflammation, regeneration, microcirculation, neoangiogenesis
- 1 January 2022
- Published by FSBSI Research Institute of Human Morphology in CLINICAL AND EXPERIMENTAL MORPHOLOGY
- Vol. 11 (3)
Restoration of the microvasculature and hemodynamics in the oral mucosa wound defects area with and without a piezoelectric polymer membrane
Introduction. Restoration of blood supply to tissues is crucial for the regeneration of wound defects. The purpose of this research was to study the effect of piezoelectric polymers on the restoration of microcirculation and hemodynamics in the area of oral mucosa wound defects. Materials and methods. The study was carried out on 60 Wistar rats divided into four groups (15 rats each): control (intact) and 3 experimental groups. In group 1, the animals had an open wound defect. In groups 3 and 2, the rats had a wound defect covered with a membrane with and without copper modification, respectively. The specimens for subsequent light and electron microscopy were collected on days 3, 7, and 12. We studied qualitative and quantitative indicators of microcirculation and hemodynamics restoration. Results. Day 3: in all experimental groups, the arteriolo-venular relationship and the pericapillary diffusion index significantly decreased, while the Kernogan index increased. We also observed a significant increase in VEGF expression. Day 7: in experimental group 3, the values of the Kernogan index and the arteriolo-venular relationship were restored, and the pericapillary diffusion index remained significantly higher than in the control group. In the groups 1 and 2, none of the indicators reached the control values. VEGF expression decreased in all groups. On day 12 in group 1, the arteriolo-venular relationship, the Kernogan index and the index of pericapillary diffusion differed from the control group, in contrast to groups 2 and 3, where all the studied parameters were restored. Expression of VEGF in group 1 was significantly less than the control values, and in groups 2 and 3 it was significantly higher. Conclusion. We revealed that closing of oral mucosa wound defects by a piezoelectric polymer membrane led to the restoration of hemodynamic parameters and promoted active vascular formation. Keywords: wound defect, oral cavity, inflammation, regeneration, microcirculation, neoangiogenesis
- 1 January 2022
- Published by FSBSI Research Institute of Human Morphology in CLINICAL AND EXPERIMENTAL MORPHOLOGY
- Vol. 11 (1)
Changes in the cellular composition of the inflammatory infiltrate and connective tissue of the oral mucosa in rats during wound healing using a protective piezoelectric coating
Introduction. Wound healing is a process based on a complex mechanism of intercellular interaction. The aim was to study changes in the oral mucosa cellular composition during wound healing with and without a protective piezoelectric coating. Materials and methods. The study was carried out on 50 Wistar rats divided into four groups: one control group of intact rats and experimental groups 1, 2, and 3. The rats of the experimental groups were subjected to excision of a lip mucous membrane flap with wound formation. In the animals of experimental group 1, the defect was open. In group 2, we used a polymer membrane with copper modification, and in group 3, the membrane was without copper modification. The animals were sacrificed on days 3, 7, and 12 of the study. We used light and electron microscopy to study the qualitative and quantitative changes in the composition of cell populations at the site of the defect. Results. On day 3, there prevailed neutrophilic infiltration in all groups. In groups 2 and 3, we observed a large number of macrophages and fibroblasts that indicated the transition to the next phase of wound healing. On day 7, in group 1, there persisted extensive neutrophilic and macrophage infiltration, whereas, in groups 2 and 3, the signs of inflammation decreased, and wound healing was active. On day 12, in group 1, all values were significantly higher than in the control group and there was damage to the ultrastructure; in groups 2 and 3, all the studied parameters reached the control values. Conclusion. We revealed the patterns of changes in the cellular composition of a wound during its healing. The use of the coating contributed to accelerated wound healing, which was found during the analysis of changes in the composition of cell populations. The closure of the oral mucosa wounds with polymer piezoelectric membranes was proven to have a good effect on tissue repair and was supposed to reduce the risk of postoperative complications. Keywords: wound defect, mucous membrane, oral cavity, piezoelectrics, inflammation, regeneration, scaffolds, dentistry
- 1 January 2022
- Published by FSBSI Research Institute of Human Morphology in CLINICAL AND EXPERIMENTAL MORPHOLOGY
- Vol. 11 (1)
Changes in the cellular composition of the inflammatory infiltrate and connective tissue of the oral mucosa in rats during wound healing using a protective piezoelectric coating
Introduction. Wound healing is a process based on a complex mechanism of intercellular interaction. The aim was to study changes in the oral mucosa cellular composition during wound healing with and without a protective piezoelectric coating. Materials and methods. The study was carried out on 50 Wistar rats divided into four groups: one control group of intact rats and experimental groups 1, 2, and 3. The rats of the experimental groups were subjected to excision of a lip mucous membrane flap with wound formation. In the animals of experimental group 1, the defect was open. In group 2, we used a polymer membrane with copper modification, and in group 3, the membrane was without copper modification. The animals were sacrificed on days 3, 7, and 12 of the study. We used light and electron microscopy to study the qualitative and quantitative changes in the composition of cell populations at the site of the defect. Results. On day 3, there prevailed neutrophilic infiltration in all groups. In groups 2 and 3, we observed a large number of macrophages and fibroblasts that indicated the transition to the next phase of wound healing. On day 7, in group 1, there persisted extensive neutrophilic and macrophage infiltration, whereas, in groups 2 and 3, the signs of inflammation decreased, and wound healing was active. On day 12, in group 1, all values were significantly higher than in the control group and there was damage to the ultrastructure; in groups 2 and 3, all the studied parameters reached the control values. Conclusion. We revealed the patterns of changes in the cellular composition of a wound during its healing. The use of the coating contributed to accelerated wound healing, which was found during the analysis of changes in the composition of cell populations. The closure of the oral mucosa wounds with polymer piezoelectric membranes was proven to have a good effect on tissue repair and was supposed to reduce the risk of postoperative complications. Keywords: wound defect, mucous membrane, oral cavity, piezoelectrics, inflammation, regeneration, scaffolds, dentistry