Ogün Altun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ogün Altun has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ozan Keysan
Middle East Technical University
7 shared publications - Enes Ayaz
Department of Electric Power and Energy Systems, KTH Royal Institute of Technology, Stockholm, Sweden
5 shared publications - Mustafa Umit Oner
Bahcesehir University
2 shared publications - Ozturk Sahin Alemdar
METU PowerLab, Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara, Turkey
2 shared publications Hakan Polat
Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara, Turkey
1 shared publication- Hakan Polat
MOBI-EPOWERS Research Group, Electrical Engineering and Energy Technology Department, Vrije Universiteit Brussel (VUB), Pleinlaan 2, 1050 Brussels, Belgium
1 shared publication
Latest Publications
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (11) , 11250-11260
Capacitor Lifetime Extension in Power Converter Systems Using Neural Networks
Capacitors are one of the main components that limit the overall reliability of a power electronics converter. The major parameter limiting the lifetime of a capacitor is the hotspot temperature, which is directly related to the amount of ripple current flowing through the capacitor. For converters employing paralleled power stages, PWM interleaving has been traditionally applied to minimize capacitor current ripple. In multiinput, single-output power converters, PWM interleaving can also be employed to minimize the common capacitors’ current ripple. In these systems, finding the optimal phase shift is not trivial though. In this article, neural networks yield optimal phase shift values to operate the common capacitor at the minimum ripple state, enabling capacitor lifetime extension. The proposed technique was validated on a three-level Boost converter with 2 and 3 cells. The effectiveness of the proposed technique is shown through experimental results.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (11) , 11250-11260
Capacitor Lifetime Extension in Power Converter Systems Using Neural Networks
Capacitors are one of the main components that limit the overall reliability of a power electronics converter. The major parameter limiting the lifetime of a capacitor is the hotspot temperature, which is directly related to the amount of ripple current flowing through the capacitor. For converters employing paralleled power stages, PWM interleaving has been traditionally applied to minimize capacitor current ripple. In multiinput, single-output power converters, PWM interleaving can also be employed to minimize the common capacitors’ current ripple. In these systems, finding the optimal phase shift is not trivial though. In this article, neural networks yield optimal phase shift values to operate the common capacitor at the minimum ripple state, enabling capacitor lifetime extension. The proposed technique was validated on a three-level Boost converter with 2 and 3 cells. The effectiveness of the proposed technique is shown through experimental results.
- 3 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 135-141
Narrowband and Wideband Dual-Mode Wireless Power Transfer System With a Single Transmitter
This study introduces a dual-mode wireless power transfer system for multistandard wireless charging products. The system allows two receivers to operate concurrently at narrowband and wideband frequencies using the proposed sinusoidal pulse width modulation (SPWM). Conventional SPWM does not provide independent control of switching and sideband harmonics, which are required for dual-mode excitation. We propose a new hybrid carrier and reference phase shift method to provide independent control of the reference, switching, and sideband harmonics. A prototype has been developed to validate power transfer at both narrowband (951 and 1190 kHz) and wideband (100 and 1190 kHz) frequency operations.
- 3 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 135-141
Narrowband and Wideband Dual-Mode Wireless Power Transfer System With a Single Transmitter
This study introduces a dual-mode wireless power transfer system for multistandard wireless charging products. The system allows two receivers to operate concurrently at narrowband and wideband frequencies using the proposed sinusoidal pulse width modulation (SPWM). Conventional SPWM does not provide independent control of switching and sideband harmonics, which are required for dual-mode excitation. We propose a new hybrid carrier and reference phase shift method to provide independent control of the reference, switching, and sideband harmonics. A prototype has been developed to validate power transfer at both narrowband (951 and 1190 kHz) and wideband (100 and 1190 kHz) frequency operations.
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3411-3421
Ripple Minimization in Asymmetric Interleaved DC–DC Converters Using Neural Networks
Interleaving can be employed to reduce ripples in multiphase dc–dc converters although phases are operated under asymmetric conditions, such as different input voltages or loads. To allow ripple minimization under asymmetric conditions, phase shifts between the switch timings of phases have to be appropriately adjusted. This study presents a method based on artificial neural networks (ANNs) that can provide the required phase shifts to minimize ripple under asymmetric conditions. To obtain a machine learning dataset, the set of optimal phase-shift angles minimizing the common output capacitor current ripple is analytically obtained for two asymmetric interleaved boost converters. Then, a small-scale computationally efficient ANN is developed using the dataset to predict the optimal phase shift according to real-time operating conditions. The proposed method is experimentally validated. The proposed method predicts the optimal phase-shift angle in 28.4 $\mu \text{s}$ and the prediction is updated every 100 $\mu \text{s}$ to achieve ripple minimization.
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3411-3421
Ripple Minimization in Asymmetric Interleaved DC–DC Converters Using Neural Networks
Interleaving can be employed to reduce ripples in multiphase dc–dc converters although phases are operated under asymmetric conditions, such as different input voltages or loads. To allow ripple minimization under asymmetric conditions, phase shifts between the switch timings of phases have to be appropriately adjusted. This study presents a method based on artificial neural networks (ANNs) that can provide the required phase shifts to minimize ripple under asymmetric conditions. To obtain a machine learning dataset, the set of optimal phase-shift angles minimizing the common output capacitor current ripple is analytically obtained for two asymmetric interleaved boost converters. Then, a small-scale computationally efficient ANN is developed using the dataset to predict the optimal phase shift according to real-time operating conditions. The proposed method is experimentally validated. The proposed method predicts the optimal phase-shift angle in 28.4 $\mu \text{s}$ and the prediction is updated every 100 $\mu \text{s}$ to achieve ripple minimization.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (10) , 13243-13253
Variable Carrier Phase-Shift Method for Integrated Contactless Field Excitation System of Electrically Excited Synchronous Motors
This article presents a novel contactless field excitation (CFE) system based on wireless power transfer (WPT), which utilizes the existing voltage source inverter (VSI) of the motor drive for electrically excited synchronous motors (EESMs). In conventional CFE systems, an extra high-frequency converter is required to excite the field winding. In this article, it is proposed to utilize existing voltage switching harmonics of the VSI for exciting the field winding while the low-frequency modulated component is used to drive the motor. In the proposed system, a novel variable carrier phase-shift method is developed to achieve constant input excitation voltage for the WPT part independently from the motor operation. In addition, a hybrid frequency detuning control method is introduced to adjust the field current. For experimental validation, a small-scale prototype with a 100-V dc-link and a 60-kHz switching frequency is established. It is observed that the field current could be kept almost constant at 5 A under different motor driving conditions operations regarding modulation index and fundamental frequency. Also, it is shown that the field current could be reduced by detuning the switching frequency. In brief, without an additional active converter and only with a software update, a cost-effective CFE system for EESMs can be easily implemented.
- 1 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (10) , 13243-13253
Variable Carrier Phase-Shift Method for Integrated Contactless Field Excitation System of Electrically Excited Synchronous Motors
This article presents a novel contactless field excitation (CFE) system based on wireless power transfer (WPT), which utilizes the existing voltage source inverter (VSI) of the motor drive for electrically excited synchronous motors (EESMs). In conventional CFE systems, an extra high-frequency converter is required to excite the field winding. In this article, it is proposed to utilize existing voltage switching harmonics of the VSI for exciting the field winding while the low-frequency modulated component is used to drive the motor. In the proposed system, a novel variable carrier phase-shift method is developed to achieve constant input excitation voltage for the WPT part independently from the motor operation. In addition, a hybrid frequency detuning control method is introduced to adjust the field current. For experimental validation, a small-scale prototype with a 100-V dc-link and a 60-kHz switching frequency is established. It is observed that the field current could be kept almost constant at 5 A under different motor driving conditions operations regarding modulation index and fundamental frequency. Also, it is shown that the field current could be reduced by detuning the switching frequency. In brief, without an additional active converter and only with a software update, a cost-effective CFE system for EESMs can be easily implemented.
- 18 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (9) , 8645-8654
Carrier Phase Shift Method of SPWM for Concurrent Wired and Wireless Power Transfer Systems
This paper presents an approach for concurrent power transfer to wired and wireless systems using just a single inverter. The approach utilizes a novel carrier phase-shift (CPS) method that independently controls the inverter output voltages at the fundamental and switching frequencies. This proposed method can be a cost-effective solution to wireless power transfer (WPT) systems used in contactless slip rings (CSR), which transfer power to auxiliary loads such as sensors, radars, and IoT devices. There are two separate converters in conventional CSR systems: one is for the motor drive, and the other is for the WPT system. It is proposed that the switching harmonics of the motor drive can also be utilized to excite the WPT system while the low-frequency component can still be used to drive the motor. In order to control these independently, the CPS method is introduced. The proposed method is investigated analytically for sinusoidal-PWM (SPWM). Then, an experimental setup consisting of a 3-phase 3-wire GaN-based inverter and a 3-phase motor is built. Experimental results show that the WPT and motor systems are operated concurrently, and their powers are controlled independently by the proposed method.
- 18 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 70 (9) , 8645-8654
Carrier Phase Shift Method of SPWM for Concurrent Wired and Wireless Power Transfer Systems
This paper presents an approach for concurrent power transfer to wired and wireless systems using just a single inverter. The approach utilizes a novel carrier phase-shift (CPS) method that independently controls the inverter output voltages at the fundamental and switching frequencies. This proposed method can be a cost-effective solution to wireless power transfer (WPT) systems used in contactless slip rings (CSR), which transfer power to auxiliary loads such as sensors, radars, and IoT devices. There are two separate converters in conventional CSR systems: one is for the motor drive, and the other is for the WPT system. It is proposed that the switching harmonics of the motor drive can also be utilized to excite the WPT system while the low-frequency component can still be used to drive the motor. In order to control these independently, the CPS method is introduced. The proposed method is investigated analytically for sinusoidal-PWM (SPWM). Then, an experimental setup consisting of a 3-phase 3-wire GaN-based inverter and a 3-phase motor is built. Experimental results show that the WPT and motor systems are operated concurrently, and their powers are controlled independently by the proposed method.
- 21 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (1) , 1272-1284
Fault Tolerant Multi-Tx/Multi-Rx Inductive Power Transfer System With a Resonator Coil
This paper presents a novel multi-transmitter (Tx) / multi-receiver (Rx) inductive power transfer system. Compared to conventional single-Tx/single-Rx systems, multi-Tx/multi-Rx topologies increase reliability and fault tolerance. However, unequal power distribution is challenging in these systems due to coupling differences, which prevents them from operating at rated power or requires over-designed modules. This study proposes the addition of a middle-stage resonator (MSR) that balances power distribution by separating direct couplings between Tx and Rx coils. Thus, it increases reliability and fault tolerance. Direct couplings between Tx and Rx coils are avoided via the proposed coil structure, which also provides rotational symmetry. Moreover, an analytical method is proposed to avoid bifurcation, which reduces switching losses. Then, the fault tolerance analysis on multi-Tx/multi-Rx systems and optimum selection of module numbers are investigated. Finally, a 1kW 2Tx/1MSR/4Rx prototype is established to continue operation under single-Tx, single-Rx, and double-Rx open circuit faults.
- 21 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (1) , 1272-1284
Fault Tolerant Multi-Tx/Multi-Rx Inductive Power Transfer System With a Resonator Coil
This paper presents a novel multi-transmitter (Tx) / multi-receiver (Rx) inductive power transfer system. Compared to conventional single-Tx/single-Rx systems, multi-Tx/multi-Rx topologies increase reliability and fault tolerance. However, unequal power distribution is challenging in these systems due to coupling differences, which prevents them from operating at rated power or requires over-designed modules. This study proposes the addition of a middle-stage resonator (MSR) that balances power distribution by separating direct couplings between Tx and Rx coils. Thus, it increases reliability and fault tolerance. Direct couplings between Tx and Rx coils are avoided via the proposed coil structure, which also provides rotational symmetry. Moreover, an analytical method is proposed to avoid bifurcation, which reduces switching losses. Then, the fault tolerance analysis on multi-Tx/multi-Rx systems and optimum selection of module numbers are investigated. Finally, a 1kW 2Tx/1MSR/4Rx prototype is established to continue operation under single-Tx, single-Rx, and double-Rx open circuit faults.
- 22 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (2) , 1587-1596
Balancing of Common DC-Bus Parallel-Connected Modular Inductive Power Transfer Systems
The aim of this paper is to design a modular, fault tolerant multi-transmitter(Tx)/multi-receiver(Rx) parallel connected common DC bus inductive power transfer(IPT) system to replace slip rings in wind turbines or brushless exciters. In parallel connected common DC bus systems, current unbalance is a major issue that results in thermal stresses and over current or voltages. In this paper, two different new current balancing methods are proposed: Cross-coupled Rx modules and intentional de-tuning of Rx side resonant frequency. These methods are investigated both analytically and experimentally for a single Tx and two Rx system for a 500 W prototype. The proposed methods are tested independently, and then the combined current balancing method is also investigated. For the same misalignment case, cross-coupled/de-tuned has a 55.8% current balancing improvement compared to de-coupled/fully-tuned topology.
- 22 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (2) , 1587-1596
Balancing of Common DC-Bus Parallel-Connected Modular Inductive Power Transfer Systems
The aim of this paper is to design a modular, fault tolerant multi-transmitter(Tx)/multi-receiver(Rx) parallel connected common DC bus inductive power transfer(IPT) system to replace slip rings in wind turbines or brushless exciters. In parallel connected common DC bus systems, current unbalance is a major issue that results in thermal stresses and over current or voltages. In this paper, two different new current balancing methods are proposed: Cross-coupled Rx modules and intentional de-tuning of Rx side resonant frequency. These methods are investigated both analytically and experimentally for a single Tx and two Rx system for a 500 W prototype. The proposed methods are tested independently, and then the combined current balancing method is also investigated. For the same misalignment case, cross-coupled/de-tuned has a 55.8% current balancing improvement compared to de-coupled/fully-tuned topology.