Jinyu Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jinyu Zhao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Minwu Chen
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication- Minwu Chen
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication Xin Gong
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publicationYu Cao
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
1 shared publication- Zhe Cheng
National Rail Transportation Electrification and Automation Engineering Technology Research Centre, Chengdu, China
1 shared publication - Zhongbei Tian
University of Birmingham
1 shared publication
Latest Publications
- Open Access
- 11 April 2023
- Published by Springer Nature in Railway Engineering Science
- Vol. 31 (4) , 396-410
Electromagnetic interference assessment of a train–network–pipeline coupling system based on a harmonic transmission model
The harmonics and resonance of traction power supply systems (TPSSs) aggravate the electromagnetic interference (EMI) to adjacent metallic pipelines (MPs), which has aroused widespread concern. In this paper, an evaluation method on pipeline interference voltage under harmonic induction is presented. The results show that the Carson integral formula is more accurate in calculating the mutual impedance at higher frequencies. Then, an integrated train–network–pipeline model is established to estimate the influences of harmonic distortion and resonance on an MP. It is revealed that the higher the harmonic current distortion rate of the traction load, the larger the interference voltage on an MP. Particularly, the interference voltage is amplified up to 7 times when the TPSS resonates, which is worthy of attention. In addition, the parameters that affect the variation and sensitivity of the interference voltage are studied, namely, the pipeline coating material, locomotive position, and soil resistivity, indicating that soil resistivity and 3PE (3-layer polyethylene) anticorrosive coating are more sensitive to harmonic induction. Field test results show that the harmonic distortion can make the interference voltage more serious, and the protective measures are optimized.
- 11 April 2023
- Published by Springer Nature in Railway Engineering Science
- Vol. 31 (4) , 396-410
Open AccessElectromagnetic interference assessment of a train–network–pipeline coupling system based on a harmonic transmission model
The harmonics and resonance of traction power supply systems (TPSSs) aggravate the electromagnetic interference (EMI) to adjacent metallic pipelines (MPs), which has aroused widespread concern. In this paper, an evaluation method on pipeline interference voltage under harmonic induction is presented. The results show that the Carson integral formula is more accurate in calculating the mutual impedance at higher frequencies. Then, an integrated train–network–pipeline model is established to estimate the influences of harmonic distortion and resonance on an MP. It is revealed that the higher the harmonic current distortion rate of the traction load, the larger the interference voltage on an MP. Particularly, the interference voltage is amplified up to 7 times when the TPSS resonates, which is worthy of attention. In addition, the parameters that affect the variation and sensitivity of the interference voltage are studied, namely, the pipeline coating material, locomotive position, and soil resistivity, indicating that soil resistivity and 3PE (3-layer polyethylene) anticorrosive coating are more sensitive to harmonic induction. Field test results show that the harmonic distortion can make the interference voltage more serious, and the protective measures are optimized.
- 29 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (1) , 936-947
Optimal Scheduling of FTPSS With PV and HESS Considering the Online Degradation of Battery Capacity
To improve the power quality (PQ) and eliminate the neutral zone (NZ), a flexible traction power supply system (FTPSS) was proposed to provide flexible interfaces for hybrid energy storage system (HESS) and photovoltaic (PV). However, in order to realize the optimal scheduling of FTPSS, it is necessary to further study the high cost of HESS and battery available capacity. In this study, a two-layer model with the lowest comprehensive cost as the goal is proposed, which includes the cost of investment, replacement, operation and maintenance (O&M), and electricity. In the upper layer, the HESS sizing and replacement strategy are performed to achieve the lowest daily comprehensive cost within the project period. In the lower layer, based on the piecewise linear method, the battery capacity degradation is formulated as a linear mathematical model concerning the depth of discharge (DOD). Then, with the aim to achieve the lowest electricity charge, a mixed-integer linear programming (MILP) model is formulated by associating PV, regenerative braking energy (RBE), and HESS. Sparrow search algorithm (SSA) with CPLEX solver embedded is utilized to solve this two-layer nonlinear model. Finally, the simulation results show that the proposed model can achieve a 13.55% cost reduction.
- 29 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (1) , 936-947
Optimal Scheduling of FTPSS With PV and HESS Considering the Online Degradation of Battery Capacity
To improve the power quality (PQ) and eliminate the neutral zone (NZ), a flexible traction power supply system (FTPSS) was proposed to provide flexible interfaces for hybrid energy storage system (HESS) and photovoltaic (PV). However, in order to realize the optimal scheduling of FTPSS, it is necessary to further study the high cost of HESS and battery available capacity. In this study, a two-layer model with the lowest comprehensive cost as the goal is proposed, which includes the cost of investment, replacement, operation and maintenance (O&M), and electricity. In the upper layer, the HESS sizing and replacement strategy are performed to achieve the lowest daily comprehensive cost within the project period. In the lower layer, based on the piecewise linear method, the battery capacity degradation is formulated as a linear mathematical model concerning the depth of discharge (DOD). Then, with the aim to achieve the lowest electricity charge, a mixed-integer linear programming (MILP) model is formulated by associating PV, regenerative braking energy (RBE), and HESS. Sparrow search algorithm (SSA) with CPLEX solver embedded is utilized to solve this two-layer nonlinear model. Finally, the simulation results show that the proposed model can achieve a 13.55% cost reduction.