Yonggan Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yonggan Yan has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Shuxiang Guo
Department of Electronic and Electrical Engineering, Southern University of Science and Technology, Shenzhen, China
9 shared publications - Chuqiao Lyu
School of Life Science, Beijing Institute of Technology, Beijing, China
6 shared publications - Jianmin Liu
Neurovascular Center, Changhai Hospital, Naval Medical University, Shanghai, China
4 shared publications - Pengfei Yang
Neurovascular Center, Changhai Hospital, Naval Medical University, Shanghai, China
4 shared publications - Yongwei Zhang
Neurovascular Center, Changhai Hospital, Naval Medical University, Shanghai, China
4 shared publications - Yongxin Zhang
Neurovascular Center, Changhai Hospital, Naval Medical University, Shanghai, China
4 shared publications
Latest Publications
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (9) , 8770-8777
A Novel Dexterous Steerable Catheter Robot System: Design, Modeling and Evaluation
Vascular interventional surgery (VIS) robots still face limitations in enhancing treatment quality. The primary challenges come from the accurate morphology control and miniaturization of the distal instruments. To address these issues, a novel 4 degrees of freedom steerable catheter robotic system is developed. The catheter is composed of two segments continua connected in series. By actuating the two segments independently, the distal end of the catheter has both position and wide-range orientation control capabilities. To accurately estimate the continuum deformation, an improved tendon tension propagation model considering the path friction is proposed. Then a continuum morphology estimation model is derived cell by cell based on the chain beam assumption. Based on the estimation model, the kinetostatic model is established and a model-based nonlinear numerical solution method is developed to obtain the inverse solution of the actuation space. Experimental results demonstrate that the improved tendon tension propagation model reduces the control errors in position and orientation by 45.6% and 57.6% respectively compared with the simplified model. Additionally, the dexterity and operability of the robotic system are demonstrated by 4 navigation experiments.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (9) , 8770-8777
A Novel Dexterous Steerable Catheter Robot System: Design, Modeling and Evaluation
Vascular interventional surgery (VIS) robots still face limitations in enhancing treatment quality. The primary challenges come from the accurate morphology control and miniaturization of the distal instruments. To address these issues, a novel 4 degrees of freedom steerable catheter robotic system is developed. The catheter is composed of two segments continua connected in series. By actuating the two segments independently, the distal end of the catheter has both position and wide-range orientation control capabilities. To accurately estimate the continuum deformation, an improved tendon tension propagation model considering the path friction is proposed. Then a continuum morphology estimation model is derived cell by cell based on the chain beam assumption. Based on the estimation model, the kinetostatic model is established and a model-based nonlinear numerical solution method is developed to obtain the inverse solution of the actuation space. Experimental results demonstrate that the improved tendon tension propagation model reduces the control errors in position and orientation by 45.6% and 57.6% respectively compared with the simplified model. Additionally, the dexterity and operability of the robotic system are demonstrated by 4 navigation experiments.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 5213-5224
5-DOF Microcoil Positioning System Utilizing Single-Axis Electromagnetic Transmitter
The lack of 3-D localization impedes the advancement of various intracorporeal medical devices. Developing an occlusion-free, small-sized, and high-precision positioning system remains a significant challenge in the practical application of interventional robotics. In this article, a novel 5-degree of freedom (DoF) positioning system utilizing single-axis electromagnetic field excitation coil is designed to locate a microcoil with a size of $\phi$ 1.45 × 5 mm. An XGBoost-based induced electromotive force (EMF) prediction model is proposed to correct the deviation of the magnetic dipole model near the excitation source. Employing the model, a positioning dataset under rotating magnetic field is synthesized. Subsequently, a CNN-LSTM based 5-DoF positioning model is designed and trained, and the transmitting coil speed characteristics of the model were experimentally verified. Evaluation experiments for the two models are performed separately. The results demonstrate the XGBoost-based EMF prediction model improved the prediction accuracy by 34.4% compared to the conventional magnetic dipole model. The static average localization error of the 5-DoF positioning model is 2.53 mm and the orientation error is 2.24$^\circ$ within the $\phi$ 150 × 70 mm volume. The dynamic tracking experimental results indicate that the localization tracking error is 4.25 mm and the orientation error is 3.44$^\circ$, which are 62% and 78% higher than the Levenberg–Marquardt algorithm. The navigation experiment conducted in a coronary artery phantom demonstrated the potential for use in narrow tracts.
- 11 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (6) , 5213-5224
5-DOF Microcoil Positioning System Utilizing Single-Axis Electromagnetic Transmitter
The lack of 3-D localization impedes the advancement of various intracorporeal medical devices. Developing an occlusion-free, small-sized, and high-precision positioning system remains a significant challenge in the practical application of interventional robotics. In this article, a novel 5-degree of freedom (DoF) positioning system utilizing single-axis electromagnetic field excitation coil is designed to locate a microcoil with a size of $\phi$ 1.45 × 5 mm. An XGBoost-based induced electromotive force (EMF) prediction model is proposed to correct the deviation of the magnetic dipole model near the excitation source. Employing the model, a positioning dataset under rotating magnetic field is synthesized. Subsequently, a CNN-LSTM based 5-DoF positioning model is designed and trained, and the transmitting coil speed characteristics of the model were experimentally verified. Evaluation experiments for the two models are performed separately. The results demonstrate the XGBoost-based EMF prediction model improved the prediction accuracy by 34.4% compared to the conventional magnetic dipole model. The static average localization error of the 5-DoF positioning model is 2.53 mm and the orientation error is 2.24$^\circ$ within the $\phi$ 150 × 70 mm volume. The dynamic tracking experimental results indicate that the localization tracking error is 4.25 mm and the orientation error is 3.44$^\circ$, which are 62% and 78% higher than the Levenberg–Marquardt algorithm. The navigation experiment conducted in a coronary artery phantom demonstrated the potential for use in narrow tracts.
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Deep-Learning-Based Force Sensing Method for a Flexible Endovascular Surgery Robot
Endovascular surgical robots (ESRs) are extensively researched because of their potential to minimize surgeons’ radiation exposure. However, during the surgical operation, it is difficult for ESR to achieve the same flexibility in manipulating the soft catheter and the slender guidewire as human fingers. The flexibility of ESR can be enhanced by incorporating a soft gripper, but the nonlinear deformation of soft material presents challenges in sensing and controlling the force. To address these issues, this study proposes a deep learning-based force sensing method that enables the flexible ESR to measure the surgical force and torque. The proposed deep learning model consists of multiple-layer Long Short-Term Memory (LSTM) modules and is trained using the robot’s motion and soft gripper deformation datasets. The well-trained LSTM model can predict the operationing force and torque in real time. The contrast experiments with other models demonstrate that our robot exhibits higher force measurement accuracy. Furthermore, a force control strategy is proposed for the application of LSTMbased ESR. In the force control strategy, the robot is encouraged to mimic the dexterity of surgeon’s fingers and to maintain the force within a safe range. Finally, the proposed strategy is compared with other strategies in vascular phantom experiments and is proven to effectively enhance the safety and efficiency of surgical operations.
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Deep-Learning-Based Force Sensing Method for a Flexible Endovascular Surgery Robot
Endovascular surgical robots (ESRs) are extensively researched because of their potential to minimize surgeons’ radiation exposure. However, during the surgical operation, it is difficult for ESR to achieve the same flexibility in manipulating the soft catheter and the slender guidewire as human fingers. The flexibility of ESR can be enhanced by incorporating a soft gripper, but the nonlinear deformation of soft material presents challenges in sensing and controlling the force. To address these issues, this study proposes a deep learning-based force sensing method that enables the flexible ESR to measure the surgical force and torque. The proposed deep learning model consists of multiple-layer Long Short-Term Memory (LSTM) modules and is trained using the robot’s motion and soft gripper deformation datasets. The well-trained LSTM model can predict the operationing force and torque in real time. The contrast experiments with other models demonstrate that our robot exhibits higher force measurement accuracy. Furthermore, a force control strategy is proposed for the application of LSTMbased ESR. In the force control strategy, the robot is encouraged to mimic the dexterity of surgeon’s fingers and to maintain the force within a safe range. Finally, the proposed strategy is compared with other strategies in vascular phantom experiments and is proven to effectively enhance the safety and efficiency of surgical operations.
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Grasping-Force-Based Passive Safety Method for a Vascular Interventional Surgery Robot System
Robot-assisted vascular interventional surgery changes the surgeons’ original operation, which affects their judgment and surgical safety. Therefore, the reliable safety method for robot-assisted surgery is practically valuable. However, the existing active safety methods have two challenges: the difficulty in setting inserting force thresholds suitable for the current vascular environment and the response delay caused by program processing. The paper improved a SEA(series elastic actuator)-based guidewire manipulator with an adjustable grasping force function. A multifunctional finger pulp was designed to measure the guidewire inserting force and perceive the manipulating state between fingers simultaneously. Then, an orthogonal force coupling model based on the mechanical-molecular friction theory was established to demonstrate the friction mechanism of cylindrical surgical instruments grasped by elastic grasping surfaces. Based on the model, a passive safety method was proposed to adjust the grasping force autonomously, which can satisfy the inserting force requirements of the phase delivery task and control the safety threshold suitable for the current environment. The evaluation experimental results demonstrated that the designed robot system could manipulate the guidewire accurately. Then the friction experiments verified the designed orthogonal force coupling model. Finally, the in vitro experiments were performed to demonstrated that the designed passive safety method can automatically adjust the grasping force based on the inserting states of the guidewire, reduce the contact force with the vessels, and ensure surgical safety in real-time.
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Grasping-Force-Based Passive Safety Method for a Vascular Interventional Surgery Robot System
Robot-assisted vascular interventional surgery changes the surgeons’ original operation, which affects their judgment and surgical safety. Therefore, the reliable safety method for robot-assisted surgery is practically valuable. However, the existing active safety methods have two challenges: the difficulty in setting inserting force thresholds suitable for the current vascular environment and the response delay caused by program processing. The paper improved a SEA(series elastic actuator)-based guidewire manipulator with an adjustable grasping force function. A multifunctional finger pulp was designed to measure the guidewire inserting force and perceive the manipulating state between fingers simultaneously. Then, an orthogonal force coupling model based on the mechanical-molecular friction theory was established to demonstrate the friction mechanism of cylindrical surgical instruments grasped by elastic grasping surfaces. Based on the model, a passive safety method was proposed to adjust the grasping force autonomously, which can satisfy the inserting force requirements of the phase delivery task and control the safety threshold suitable for the current environment. The evaluation experimental results demonstrated that the designed robot system could manipulate the guidewire accurately. Then the friction experiments verified the designed orthogonal force coupling model. Finally, the in vitro experiments were performed to demonstrated that the designed passive safety method can automatically adjust the grasping force based on the inserting states of the guidewire, reduce the contact force with the vessels, and ensure surgical safety in real-time.
- 11 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (10) , 6171-6178
Flexible Tactile-Sensing Gripper Design and Excessive Force Protection Function for Endovascular Surgery Robots
Research on endovascular surgery robots (ESR) is continuously developing, because ESR can protect surgeons from radiation exposure. For designing an ESR manipulator, the main challenge is controlling the soft surgical tools and measuring the endovascular stress simultaneously. In this paper, a flexible tactile-sensing gripper (FTG) is designed to realize the stable grasping of the surgical catheter and the tactile sensing of catheter force. Firstly, a catheter grasping model was constructed, and the factors affecting the force measurement were quantita-tively analyzed. Secondly, the simulation experiments based on FTG models with three different sizes were implemented. When the catheter force was too large, shrinking the grasping distance of FTG can avoid the surgical risk. This method protected the surgeon's behavior and controlled the catheter force at the same time, which was called excessive force protection function (EFPF). Thirdly, based on simulation results, we made a FTG prototype which meet the surgical requirements and integrated it into an ESR manipulator. This manipulator could measure the catheter forces by detecting the coordinate change of marking points on FTG surface. The calibrated FTG prototype got average and maximum errors of force sensing approximately 37 mN and 223 mN, respectively. Finally, the proposed EFPF is evaluated. In the experiment of carotid artery catheterization, EFPF controlled the catheter force within 393 mN, which was far less than the control group's 1351 mN.
- 11 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (10) , 6171-6178
Flexible Tactile-Sensing Gripper Design and Excessive Force Protection Function for Endovascular Surgery Robots
Research on endovascular surgery robots (ESR) is continuously developing, because ESR can protect surgeons from radiation exposure. For designing an ESR manipulator, the main challenge is controlling the soft surgical tools and measuring the endovascular stress simultaneously. In this paper, a flexible tactile-sensing gripper (FTG) is designed to realize the stable grasping of the surgical catheter and the tactile sensing of catheter force. Firstly, a catheter grasping model was constructed, and the factors affecting the force measurement were quantita-tively analyzed. Secondly, the simulation experiments based on FTG models with three different sizes were implemented. When the catheter force was too large, shrinking the grasping distance of FTG can avoid the surgical risk. This method protected the surgeon's behavior and controlled the catheter force at the same time, which was called excessive force protection function (EFPF). Thirdly, based on simulation results, we made a FTG prototype which meet the surgical requirements and integrated it into an ESR manipulator. This manipulator could measure the catheter forces by detecting the coordinate change of marking points on FTG surface. The calibrated FTG prototype got average and maximum errors of force sensing approximately 37 mN and 223 mN, respectively. Finally, the proposed EFPF is evaluated. In the experiment of carotid artery catheterization, EFPF controlled the catheter force within 393 mN, which was far less than the control group's 1351 mN.
- Open Access
- 16 December 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2237
A Deep-Learning-Based Guidewire Compliant Control Method for the Endovascular Surgery Robot
Endovascular surgery is a high-risk operation with limited vision and intractable guidewires. At present, endovascular surgery robot (ESR) systems based on force feedback liberates surgeons’ operation skills, but it lacks the ability to combine force perception with vision. In this study, a deep learning-based guidewire-compliant control method (GCCM) is proposed, which guides the robot to avoid surgical risks and improve the efficiency of guidewire operation. First, a deep learning-based model called GCCM-net is built to identify whether the guidewire tip collides with the vascular wall in real time. The experimental results in a vascular phantom show that the best accuracy of GCCM-net is 94.86 ± 0.31%. Second, a real-time operational risk classification method named GCCM-strategy is proposed. When the surgical risks occur, the GCCM-strategy uses the result of GCCM-net as damping and decreases the robot’s running speed through virtual resistance. Compared with force sensors, the robot with GCCM-strategy can alleviate the problem of force position asynchrony caused by the long and soft guidewires in real-time. Experiments run by five guidewire operators show that the GCCM-strategy can reduce the average operating force by 44.0% and shorten the average operating time by 24.6%; therefore the combination of vision and force based on deep learning plays a positive role in improving the operation efficiency in ESR.
- 16 December 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2237
Open AccessA Deep-Learning-Based Guidewire Compliant Control Method for the Endovascular Surgery Robot
Endovascular surgery is a high-risk operation with limited vision and intractable guidewires. At present, endovascular surgery robot (ESR) systems based on force feedback liberates surgeons’ operation skills, but it lacks the ability to combine force perception with vision. In this study, a deep learning-based guidewire-compliant control method (GCCM) is proposed, which guides the robot to avoid surgical risks and improve the efficiency of guidewire operation. First, a deep learning-based model called GCCM-net is built to identify whether the guidewire tip collides with the vascular wall in real time. The experimental results in a vascular phantom show that the best accuracy of GCCM-net is 94.86 ± 0.31%. Second, a real-time operational risk classification method named GCCM-strategy is proposed. When the surgical risks occur, the GCCM-strategy uses the result of GCCM-net as damping and decreases the robot’s running speed through virtual resistance. Compared with force sensors, the robot with GCCM-strategy can alleviate the problem of force position asynchrony caused by the long and soft guidewires in real-time. Experiments run by five guidewire operators show that the GCCM-strategy can reduce the average operating force by 44.0% and shorten the average operating time by 24.6%; therefore the combination of vision and force based on deep learning plays a positive role in improving the operation efficiency in ESR.
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
SEA-Based Humanoid Finger-Functional Parallel Gripper With Two Actuators: PG2 Gripper
The flexible grasping, force sensing, and in-hand manipulating abilities of the gripper are theoretically significant and practically valuable to solve. However, it is still difficult for most existing grippers to realize these three functions simultaneously. This paper proposed a novel humanoid finger-functional parallel gripper with two actuators based on overlapping parallelogram mechanisms and the series elastic actuator (SEA). Based on the in-hand manipulation principle for the ordinary contour object, an in-hand manipulation algorithm for grasping force and position decoupling was designed. Then, to adjust the posture and position of objects within parallel fingers, the rolling and sliding conditions of objects based on the molecular-mechanical friction theory were analyzed. Combined with the proposed in-hand manipulating conditions and algorithm, the PG2 gripper can control the grasping force and manipulate the ordinary contour object in-hand controllably. Evaluation experimental results showed that the force-position control of the PG2 gripper was decoupled stably and the gripper had high accuracy in controlling force and position. Finally, the physical features perception experiments and the in-hand manipulating experiment were carried out to demonstrate the utility of the proposed manipulating methods and algorithm, and in-hand manipulating and grasping force sensing abilities of the gripper. The possible applications of this gripper include tasks that need accurate force-position control or manipulating and sensing in-hand remotely.
- 15 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
SEA-Based Humanoid Finger-Functional Parallel Gripper With Two Actuators: PG2 Gripper
The flexible grasping, force sensing, and in-hand manipulating abilities of the gripper are theoretically significant and practically valuable to solve. However, it is still difficult for most existing grippers to realize these three functions simultaneously. This paper proposed a novel humanoid finger-functional parallel gripper with two actuators based on overlapping parallelogram mechanisms and the series elastic actuator (SEA). Based on the in-hand manipulation principle for the ordinary contour object, an in-hand manipulation algorithm for grasping force and position decoupling was designed. Then, to adjust the posture and position of objects within parallel fingers, the rolling and sliding conditions of objects based on the molecular-mechanical friction theory were analyzed. Combined with the proposed in-hand manipulating conditions and algorithm, the PG2 gripper can control the grasping force and manipulate the ordinary contour object in-hand controllably. Evaluation experimental results showed that the force-position control of the PG2 gripper was decoupled stably and the gripper had high accuracy in controlling force and position. Finally, the physical features perception experiments and the in-hand manipulating experiment were carried out to demonstrate the utility of the proposed manipulating methods and algorithm, and in-hand manipulating and grasping force sensing abilities of the gripper. The possible applications of this gripper include tasks that need accurate force-position control or manipulating and sensing in-hand remotely.
- 25 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 7106-7118
Machine Learning-Based Surgical State Perception and Collaborative Control for a Vascular Interventional Robot
In robot-assisted vascular interventional surg- ery (VIS), surgeons often need to operate outside the operating room to avoid exposure to X-ray. However, it greatly changes the operating ways of surgeons, which affects judgment and operation safety. In this paper, a novel VIS robot system was developed to predict guidewire insertion states and operate collaboratively. To assist the surgeons in perceiving the insertion state, an insertion multi-states prediction model based on softmax logistic regression was proposed. Combined with the prediction model, a human-machine collaborative control strategy was designed, which allows surgeons to perceive the insertion states based on not only the force feedback constructed by the master side but also the prediction results from the slave side. Moreover, a human-machine trust evaluation model and a master-slave collaborative mapping model were proposed for improving safety and efficiency of surgery. To verify the effectiveness of these models, the evaluation experiments in the blood vessel model were carried out. It was indicated by the experiment results that the guidewire insertion states can be predicted by the prediction model in different environments, and the overall accuracy is 93%. The master-slave mapping ratio can be adjusted by the collaborative control strategy automatically to adapt to different surgical conditions. The experimental results showed the usability of the robot-assisted VIS system with the novel force-based perception method.
- 25 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 7106-7118
Machine Learning-Based Surgical State Perception and Collaborative Control for a Vascular Interventional Robot
In robot-assisted vascular interventional surg- ery (VIS), surgeons often need to operate outside the operating room to avoid exposure to X-ray. However, it greatly changes the operating ways of surgeons, which affects judgment and operation safety. In this paper, a novel VIS robot system was developed to predict guidewire insertion states and operate collaboratively. To assist the surgeons in perceiving the insertion state, an insertion multi-states prediction model based on softmax logistic regression was proposed. Combined with the prediction model, a human-machine collaborative control strategy was designed, which allows surgeons to perceive the insertion states based on not only the force feedback constructed by the master side but also the prediction results from the slave side. Moreover, a human-machine trust evaluation model and a master-slave collaborative mapping model were proposed for improving safety and efficiency of surgery. To verify the effectiveness of these models, the evaluation experiments in the blood vessel model were carried out. It was indicated by the experiment results that the guidewire insertion states can be predicted by the prediction model in different environments, and the overall accuracy is 93%. The master-slave mapping ratio can be adjusted by the collaborative control strategy automatically to adapt to different surgical conditions. The experimental results showed the usability of the robot-assisted VIS system with the novel force-based perception method.