Diane Fournier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Diane Fournier has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- William Lemieux
Centre Hospitalier Universitaire (CHU) Sainte‐Justine Research Center Montreal Quebec Canada
2 shared publications Aby J. Mathew
BioLife Solutions, Inc. Bothell Washington USA
1 shared publication- Albert Feghaly
Institute for Research in Immunology and Cancer, Université de Montréal, Montréal, Canada
1 shared publication - Alexander H. Schmidt
DKMS Group, Tübingen, Germany
1 shared publication - Antoine Lewin
Héma‐Québec Montréal Québec Canada
1 shared publication Brenda Alder
Northside Hospital, Blood and Marrow Transplant Program, Cell Therapy Lab Atlanta Georgia USA
1 shared publication
Latest Publications
- Open Access
- 6 September 2022
- Published by Oxford University Press (OUP) in Stem Cells Translational Medicine
- Vol. 11 (Supplement) , S30
Abstract 25 ECTmatch: Optimizing Small-Scale Cord Blood Banking Through HLA Analysis
Cord blood (CB) banks have had to rely on large inventories of CB units to try to serve the largest possible proportion of the population, all the while prioritizing collection of non-Caucasian ethnic groups. However, due to the high linkage disequilibrium of HLA genes and the high frequency of several HLA alleles in the population, CB banks contain hundreds of CB units that could be matched to the same patients, making the inventory somewhat redundant from a clinical standpoint. ExCellThera developed ECTmatch, an algorithm dedicated to optimizing the selection of CB units based on in-depth HLA analysis in order to maximize the efficiency of the bank to suitably match the largest proportion of subjects within a small pool of donors. The performance of ECTmatch was evaluated in a simulation aiming to select 100 CB units from the Héma-Québec CB bank that satisfied an arbitrary minimal cell content criteria of 120 × 107 TNC and 6 × 106 CD34+ cells (n = 2,987). Selection was performed to optimize matching for the Quebec population, with a minimal HLA-match of 5/8 for HLA-A, -B, -C, and -DRB1. ECTmatch provides a suitably matched donor for 71.5% of the Quebec population, compared with only 45.0% (±2.4%) with random selection. Because patients who require a CB transplant tend to have rarer HLAs, the performance of ECTmatch was evaluated for this specific subset of patients (n = 62). Again, ECTmatch outperformed random selection, by providing a donor for 54.8% of patients, compared with only 29.9% with random selection. Finally, while ECTmatch was developed to optimize CB selection specifically for the Quebec population, it still outperformed random selection for subjects from the other Canadian provinces or the USA. By selecting CB units based on HLA profiles, ECTmatch allows the creation of a highly useful inventory with a very low number of CB units. This approach to small-scale CB banking can be adapted to different population subsets and could be used to select a subset of CB units for pre-release for immediate clinical availability or for the creation of a pre-expanded CB inventory with maximal population coverage.
- 6 September 2022
- Published by Oxford University Press (OUP) in Stem Cells Translational Medicine
- Vol. 11 (Supplement) , S30
Open AccessAbstract 25 ECTmatch: Optimizing Small-Scale Cord Blood Banking Through HLA Analysis
Cord blood (CB) banks have had to rely on large inventories of CB units to try to serve the largest possible proportion of the population, all the while prioritizing collection of non-Caucasian ethnic groups. However, due to the high linkage disequilibrium of HLA genes and the high frequency of several HLA alleles in the population, CB banks contain hundreds of CB units that could be matched to the same patients, making the inventory somewhat redundant from a clinical standpoint. ExCellThera developed ECTmatch, an algorithm dedicated to optimizing the selection of CB units based on in-depth HLA analysis in order to maximize the efficiency of the bank to suitably match the largest proportion of subjects within a small pool of donors. The performance of ECTmatch was evaluated in a simulation aiming to select 100 CB units from the Héma-Québec CB bank that satisfied an arbitrary minimal cell content criteria of 120 × 107 TNC and 6 × 106 CD34+ cells (n = 2,987). Selection was performed to optimize matching for the Quebec population, with a minimal HLA-match of 5/8 for HLA-A, -B, -C, and -DRB1. ECTmatch provides a suitably matched donor for 71.5% of the Quebec population, compared with only 45.0% (±2.4%) with random selection. Because patients who require a CB transplant tend to have rarer HLAs, the performance of ECTmatch was evaluated for this specific subset of patients (n = 62). Again, ECTmatch outperformed random selection, by providing a donor for 54.8% of patients, compared with only 29.9% with random selection. Finally, while ECTmatch was developed to optimize CB selection specifically for the Quebec population, it still outperformed random selection for subjects from the other Canadian provinces or the USA. By selecting CB units based on HLA profiles, ECTmatch allows the creation of a highly useful inventory with a very low number of CB units. This approach to small-scale CB banking can be adapted to different population subsets and could be used to select a subset of CB units for pre-release for immediate clinical availability or for the creation of a pre-expanded CB inventory with maximal population coverage.
- Open Access
- 6 September 2022
- Published by Oxford University Press (OUP) in Stem Cells Translational Medicine
- Vol. 11 (Supplement) , S33
Abstract 28 Comparative Analysis of the Cord Blood Bank in Quebec
Introduction: In the context of the regional diversity observed in the population of Quebec, the Héma-Québec Cord Blood Bank (HQ CBB) representation differs from that of the Héma-Québec Stem Cell Registry (HQ Registry). The Bank encourages registrants of non-European descent to promote diversity, and only collects from health centers around Montreal and Quebec cities because of proximity concerns. Objective: In this study, we aimed to analyze allele frequencies in the HQ CBB to assess similarities and differences in reference to the HQ Registry. Methods: The HQ Registry was previously typed using high-resolution genotyping. For the HQ CBB, ambiguous two-field HLA-A, -B, -C, and -DRB1 typing data were obtained from cord blood units. Statistical analyses were performed using the GENE[RATE] population analysis tools to estimate allele and haplotype frequencies by administrative region determined by registered postal codes. Hardy-Weinberg equilibrium was verified by the nested likelihood procedure. Finally, genetic distance was compared between the HQ Registry and the HQ CBB by region using Non-metric Multi-dimensional Scaling (NMDS). Results: Because of the small sample size in certain regions, HLA frequency was analyzed for 7 of the 17 regions within the HQ CBB with typings from 11,472 cord blood units. The HLA allele frequencies were previously assessed for the Registry, with 3,806 donors originating from 14 administrative regions. The Hardy-Weinberg equilibrium was rejected at least in relation to one locus in 3 regions (Capitale-Nationale, Montreal, and Laval), which differs from the results obtained from the Registry, in which the equilibrium was rejected only for Montreal. As in the Registry, allele frequencies in the HQ CBB varied by region but had limited overlap with the HQ Registry. Two regions (Chaudière-Appalaches and Laval) demonstrated significant differences in allele frequencies as represented in the HQ Registry versus the HQ CBB. Discussion: We observed differences in the Quebec population representation between the HQ CBB and the HQ Registry. This probably represents selection bias related to recruitment strategies and inclusion criteria. Importantly, the complementarity of these two stem cell sources could allow for a more diverse donor pool, and this understanding could also guide the recruitment strategies.
- 6 September 2022
- Published by Oxford University Press (OUP) in Stem Cells Translational Medicine
- Vol. 11 (Supplement) , S33
Open AccessAbstract 28 Comparative Analysis of the Cord Blood Bank in Quebec
Introduction: In the context of the regional diversity observed in the population of Quebec, the Héma-Québec Cord Blood Bank (HQ CBB) representation differs from that of the Héma-Québec Stem Cell Registry (HQ Registry). The Bank encourages registrants of non-European descent to promote diversity, and only collects from health centers around Montreal and Quebec cities because of proximity concerns. Objective: In this study, we aimed to analyze allele frequencies in the HQ CBB to assess similarities and differences in reference to the HQ Registry. Methods: The HQ Registry was previously typed using high-resolution genotyping. For the HQ CBB, ambiguous two-field HLA-A, -B, -C, and -DRB1 typing data were obtained from cord blood units. Statistical analyses were performed using the GENE[RATE] population analysis tools to estimate allele and haplotype frequencies by administrative region determined by registered postal codes. Hardy-Weinberg equilibrium was verified by the nested likelihood procedure. Finally, genetic distance was compared between the HQ Registry and the HQ CBB by region using Non-metric Multi-dimensional Scaling (NMDS). Results: Because of the small sample size in certain regions, HLA frequency was analyzed for 7 of the 17 regions within the HQ CBB with typings from 11,472 cord blood units. The HLA allele frequencies were previously assessed for the Registry, with 3,806 donors originating from 14 administrative regions. The Hardy-Weinberg equilibrium was rejected at least in relation to one locus in 3 regions (Capitale-Nationale, Montreal, and Laval), which differs from the results obtained from the Registry, in which the equilibrium was rejected only for Montreal. As in the Registry, allele frequencies in the HQ CBB varied by region but had limited overlap with the HQ Registry. Two regions (Chaudière-Appalaches and Laval) demonstrated significant differences in allele frequencies as represented in the HQ Registry versus the HQ CBB. Discussion: We observed differences in the Quebec population representation between the HQ CBB and the HQ Registry. This probably represents selection bias related to recruitment strategies and inclusion criteria. Importantly, the complementarity of these two stem cell sources could allow for a more diverse donor pool, and this understanding could also guide the recruitment strategies.
- 9 April 2022
- Published by Springer Nature in Bone Marrow Transplantation
- Vol. 57 (6) , 1021-1024
Impact of COVID-19 pandemic on global unrelated stem cell donations in 2020—Report from World Marrow Donor Association
- 9 April 2022
- Published by Springer Nature in Bone Marrow Transplantation
- Vol. 57 (6) , 1021-1024
Impact of COVID-19 pandemic on global unrelated stem cell donations in 2020—Report from World Marrow Donor Association
- 20 March 2022
- Published by Wiley in Transfusion
- Vol. 62 (3) , 651-662
Cryopreserved hematopoietic stem/progenitor cells stability program‐development, current status and recommendations: A brief report from the AABB‐ISCT joint working group cellular therapy product stability project team
The AABB-ISCT Joint Working Group Stability Project Team (SPT) was assigned to roadmap a path toward standardization of cryopreserved hematopoietic stem/progenitor cell (HSPC) stability programs. HSPC stability encompasses a broad scope of conditions including non-frozen ("fresh") and cryopreserved cell products, and varying methods for storage, thaw, and administration. This report assessed current practices and focused solely on cryopreserved HSPC cell therapy products to establish preliminary recommendations for a stability program roadmap. A survey was prepared by the SPT and distributed to ISCT and AABB members. Survey results were summarized and recommendations were outlined based on the responses from the survey. This report highlights current practices for cryopreserved HSPC stability programs, including additional considerations and recommendations. Eighty-two (82) centers worldwide participated in the survey. Survey results indicate variability across programs. HSPC stability depends on multiple factors within the processing facility (e.g., cryopreservation techniques, reagents used, and storage temperature) and independent variables (e.g., donor-related factors and starting material variability). While retention of hematopoietic engraftment potential is the primary goal for cryopreserved HSPC stability, engraftment results should not be used as the sole metric for stability programs. Based on the survey results, the SPT provides recommendations for consideration. The SPT recommendations for best practices are not intended to replace existing standards. The survey results emphasize the need for the community to optimize best practices and consider initiating collaborative projects to improve the standardization of cryopreserved HSPC stability programs for cell therapy products.
- 20 March 2022
- Published by Wiley in Transfusion
- Vol. 62 (3) , 651-662
Cryopreserved hematopoietic stem/progenitor cells stability program‐development, current status and recommendations: A brief report from the AABB‐ISCT joint working group cellular therapy product stability project team
The AABB-ISCT Joint Working Group Stability Project Team (SPT) was assigned to roadmap a path toward standardization of cryopreserved hematopoietic stem/progenitor cell (HSPC) stability programs. HSPC stability encompasses a broad scope of conditions including non-frozen ("fresh") and cryopreserved cell products, and varying methods for storage, thaw, and administration. This report assessed current practices and focused solely on cryopreserved HSPC cell therapy products to establish preliminary recommendations for a stability program roadmap. A survey was prepared by the SPT and distributed to ISCT and AABB members. Survey results were summarized and recommendations were outlined based on the responses from the survey. This report highlights current practices for cryopreserved HSPC stability programs, including additional considerations and recommendations. Eighty-two (82) centers worldwide participated in the survey. Survey results indicate variability across programs. HSPC stability depends on multiple factors within the processing facility (e.g., cryopreservation techniques, reagents used, and storage temperature) and independent variables (e.g., donor-related factors and starting material variability). While retention of hematopoietic engraftment potential is the primary goal for cryopreserved HSPC stability, engraftment results should not be used as the sole metric for stability programs. Based on the survey results, the SPT provides recommendations for consideration. The SPT recommendations for best practices are not intended to replace existing standards. The survey results emphasize the need for the community to optimize best practices and consider initiating collaborative projects to improve the standardization of cryopreserved HSPC stability programs for cell therapy products.
- 22 December 2009
- Published by Wiley in QSAR & Combinatorial Science
- Vol. 28 (11-12) , 1284-1299
Quantitative Structure‐Activity Relationship (QSAR) Study with a Series of 17α‐Derivatives of Estradiol: Model for the Development of Reversible Steroid Sulfatase Inhibitors
Steroid sulfatase (STS) is the steroidogenic enzyme responsible for the hydrolysis of different sulfated steroids into their corresponding hydroxylated forms. This enzyme attracts our attention for its potential role in the growth of hormone‐dependent breast and prostate tumors by the transformation of inactive sulfated precursors (which are very abundant in the blood) into active sex steroids. In order to identify the parameters responsible for good affinity with the active enzyme site and thus producing a good reversible STS inhibitor, we have built a quantitative structure‐activity relationship (QSAR) model by using MDL‐QSAR software which analyzes the molecules through more than 400 molecular descriptors. A total of 65 derivatives in position 17α of estradiol with their corresponding IC50 values were used to create our QSAR model. The linear regression converged through an optimization process to a relatively simple equation described by 4 molecular descriptors (Log P, nelem, κ0 and κα3). Virtual screening of approximately 200 molecules then enabled us to direct the synthesis of new reversible STS inhibitors.
- 22 December 2009
- Published by Wiley in QSAR & Combinatorial Science
- Vol. 28 (11-12) , 1284-1299
Quantitative Structure‐Activity Relationship (QSAR) Study with a Series of 17α‐Derivatives of Estradiol: Model for the Development of Reversible Steroid Sulfatase Inhibitors
Steroid sulfatase (STS) is the steroidogenic enzyme responsible for the hydrolysis of different sulfated steroids into their corresponding hydroxylated forms. This enzyme attracts our attention for its potential role in the growth of hormone‐dependent breast and prostate tumors by the transformation of inactive sulfated precursors (which are very abundant in the blood) into active sex steroids. In order to identify the parameters responsible for good affinity with the active enzyme site and thus producing a good reversible STS inhibitor, we have built a quantitative structure‐activity relationship (QSAR) model by using MDL‐QSAR software which analyzes the molecules through more than 400 molecular descriptors. A total of 65 derivatives in position 17α of estradiol with their corresponding IC50 values were used to create our QSAR model. The linear regression converged through an optimization process to a relatively simple equation described by 4 molecular descriptors (Log P, nelem, κ0 and κα3). Virtual screening of approximately 200 molecules then enabled us to direct the synthesis of new reversible STS inhibitors.