Xiaonan Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xiaonan Fan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chi Zhang
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences
1 shared publication - Ciyuan Xiong
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, China
1 shared publication - Guilin Yang
Chinese Academy of Sciences
1 shared publication - Jingbo Luo
Chinese Academy of Sciences
1 shared publication - Silu Chen
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China
1 shared publication - Tianjiang Zheng
Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo, China
1 shared publication
Latest Publications
- 4 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
Kinematic Calibration of a 4PPa-2PaR Parallel Mechanism With Subchains on Limbs
The newly developed 4PPa-2PaR parallel mechanism has subchains on its limbs, and the imperfect assembly process causes the kinematic error. The conventional matrix-based method is difficult to set up its kinematic error model, as the kinematic constraints cannot be represented by the homogenous transformation matrix intuitively. In this work, the actual kinematic model is established using a vector-based method, considering the nonideal lengths of links and misalignment of active joints’ home sensors. Thereby, the kinematic constraints of the mechanism are intuitively incorporated into the model, and the deviations of kinematic parameters are identified by the Levenberg–Marquardt algorithm. To achieve error compensation using the inverse of the actual kinematic model, a flange with three collinear reflector holders is designed and mounted on the moving platform, and a three-point measurement method is utilized to capture its pose without using a tracker-machine control sensor (T-MAC). Another flange for reflector holders is designed and mounted on the active joint for setting up the base frame so that all measurement data are transformed from the laser tracker’s frame to the base frame to complete the calibration process. Experiments are conducted on the testbed to validate the effectiveness of the proposed calibration method.
- 4 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
Kinematic Calibration of a 4PPa-2PaR Parallel Mechanism With Subchains on Limbs
The newly developed 4PPa-2PaR parallel mechanism has subchains on its limbs, and the imperfect assembly process causes the kinematic error. The conventional matrix-based method is difficult to set up its kinematic error model, as the kinematic constraints cannot be represented by the homogenous transformation matrix intuitively. In this work, the actual kinematic model is established using a vector-based method, considering the nonideal lengths of links and misalignment of active joints’ home sensors. Thereby, the kinematic constraints of the mechanism are intuitively incorporated into the model, and the deviations of kinematic parameters are identified by the Levenberg–Marquardt algorithm. To achieve error compensation using the inverse of the actual kinematic model, a flange with three collinear reflector holders is designed and mounted on the moving platform, and a three-point measurement method is utilized to capture its pose without using a tracker-machine control sensor (T-MAC). Another flange for reflector holders is designed and mounted on the active joint for setting up the base frame so that all measurement data are transformed from the laser tracker’s frame to the base frame to complete the calibration process. Experiments are conducted on the testbed to validate the effectiveness of the proposed calibration method.