JLJie Li

Jie Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jie Li has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Axon Trafficking Counteracts Aberrant Protein Aggregation in Neurons

    by Yu Feng, Tongshu Luan, Zhenda Zhang, Wei Wang, Yuanyuan Chu, Sijia Wan, Xiaorong Pan, Jie Li, Yifan Liu, Tong Wang

    Directed axon trafficking of mRNA via ribonucleoprotein complexes (RNPs) is essential for the proper function and survival of neurons. However, the mechanisms governing RNP transport in axons remain poorly understood. Here, we identify Annexin A7 (ANXA7) as a critical adaptor facilitating the retrograde transport of T-cell intracellular antigen 1 (TIA1)-containing RNPs by linking them to the cytoplasmic dynein. Persistent axonal Ca²⁺ elevation disrupts ANXA7’s linker role, causing the detachment of TIA1 granules from dynein, consequently impairing transport and triggering pathological TIA1 aggregation within axons. Similarly, ANXA7 knockdown decouples TIA1 granules from dynein, severely obstructing trafficking and causing pathological aggregation of TIA1 in axons, which culminates in axonopathy and neurodegeneration both in vitro and in vivo . Conversely, ANXA7 overexpression enhances trafficking and counteracts aberrant aggregation of TIA1-containing RNPs in axons. Our findings elucidate a novel mechanism underlying RNP axonal transport, highlighting its significance in the biology and pathology of central neurons.


  • Open Access

    Actomyosin-II protects axons from degeneration induced by mild mechanical stress

    by Xiaorong Pan, Yiqing Hu, Gaowei Lei, Yaxuan Wei, Jie Li, Tongshu Luan, Yunfan Zhang, Yuanyuan Chu, Yu Feng, Wenrong Zhan, et al.

    Whether, to what extent, and how the axons in the central nervous system (CNS) can withstand sudden mechanical impacts remain unclear. By using a microfluidic device to apply controlled transverse mechanical stress to axons, we determined the stress levels that most axons can withstand and explored their instant responses at nanoscale resolution. We found mild stress triggers a highly reversible, rapid axon beading response, driven by actomyosin-II–dependent dynamic diameter modulations. This mechanism contributes to hindering the long-range spread of stress-induced Ca2+ elevations into non-stressed neuronal regions. Through pharmacological and molecular manipulations in vitro, we found that actomyosin-II inactivation diminishes the reversible beading process, fostering progressive Ca2+ spreading and thereby increasing acute axonal degeneration in stressed axons. Conversely, upregulating actomyosin-II activity prevents the progression of initial injury, protecting stressed axons from acute degeneration both in vitro and in vivo. Our study unveils the periodic actomyosin-II in axon shafts cortex as a novel protective mechanism, shielding neurons from detrimental effects caused by mechanical stress.


  • Fluorescence-coded logarithmic-dilution digital droplet PCR for ultrawide-dynamic-range nucleic acid quantification

    by Qingyuan Shi, Jie Li, Chunchen Liu, Xuanpei Zhai, Long Chen, Ye Zhang, Dezhi Feng, Rong Zhang, Jian Li, Shengjie Ling, et al.


  • The emerging landscape of microfluidic applications in DNA data storage

    by Yuan Luo, Zhen Cao, Yifan Liu, Rong Zhang, Shijia Yang, Ning Wang, Qingyuan Shi, Jie Li, Shurong Dong, Chunhai Fan, et al.

    Microfluidics offers great potential as an enabling technological platform for the burgeoning field of DNA data storage, making critical contributions to improving the performance in data processing, as well as system integration and automation.


  • Open Access

    Ultra-high-throughput microbial single-cell whole genome sequencing for genome-resolved metagenomics

    by Jie Li, Rong Zhang, Ting Li, Qingyuan Shi, Zhangyue Song, Lichun Jiang, Yunfeng Shi, Conghui Ma, Xue Liang, Jingwei Zhang, et al.

    Microbes exist widely in nature. However, less than 1% of the species of microorganisms have been discovered so far, and more than 99% of microorganisms still remain unknown, which is called microbial dark matter. Unravelling microbial dark matter is not only helpful for exploring the unknown microbial world, but also of great significance for human health research. Ever since a long time ago, due to technical limitations, the microbiome, to a great extent, is still a black box. The traditional population-based metagenomic analysis tools are without single microbial resolution and they are stretched when studying rare and unknown microbial species. Here, we use high-throughput microdroplet technology to achieve the whole genome amplification of microbial single-cell genomes in pico-litter sized microdroplets, and develop subsequent library preparation steps such as indexing of the genome, to achieve the development of ultra-high-throughput microbial single-cell whole genome sequencing for genome-resolved metagenomics, aiming to provide a powerful new weapon for exploring microbial dark matter and other microbiological studies.


  • Open Access

    Hydrogel Microparticles Functionalized with Engineered Escherichia coli as Living Lactam Biosensors

    by Conghui Ma, Jie Li, Boyin Zhang, Chenxi Liu, Jingwei Zhang, Yifan Liu

    Recently there has been an increasing need for synthesizing valued chemicals through biorefineries. Lactams are an essential family of commodity chemicals widely used in the nylon industry with annual production of millions of tons. The bio-production of lactams can substantially benefit from high-throughput lactam sensing strategies for lactam producer screening. We present here a robust and living lactam biosensor that is directly compatible with high-throughput analytical means. The biosensor is a hydrogel microparticle encapsulating living microcolonies of engineered lactam-responsive Escherichia coli. The microparticles feature facile and ultra-high throughput manufacturing of up to 10,000,000 per hour through droplet microfluidics. We show that the biosensors can specifically detect major lactam species in a dose-dependent manner, which can be quantified using flow cytometry. The biosensor could potentially be used for high-throughput metabolic engineering of lactam biosynthesis.