LNLinh Viet Nguyen

Linh Viet Nguyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linh Viet Nguyen has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Stable Long-Period Grating in a Multimode Exposed-Core Fiber for High-Sensitivity Dual-Parameter Sensing

    by Dongqi Yan, Xuxia Qiao, Minglu Yan, Xue Zhou, Yana Zhang, Yong Zhao, Stephen C. Warren-Smith, Linh Viet Nguyen, Xuegang Li

  • Dynamic multimode fiber specklegram sensor with automated training data generation for bed-exit prediction

    by Md. Nazmul Islam Sarkar, Linh Viet Nguyen, Adam D. Kilpatrick, David G. Lancaster, Stephen C. Warren-Smith

    Real-time prediction of bed-exit events represents a critical capability for preventing falls and ensuring patient safety in hospital and aged care settings. Existing bed-exit detection systems operate as reactive alarms rather than predictive tools, limiting their effectiveness for fall prevention interventions. In this paper, we present a proof-of-concept system that combines dynamic multimode fiber specklegram sensor technology with deep learning to achieve predictive bed-exit detection while preserving patient privacy. We integrate a multimode optical fiber into a hospital mattress to continuously monitor speckle pattern variations caused by patient movements. An automated labeling system analyzes these patterns using zero-mean normalized cross-correlation to identify bed entry and exit events, generating training data without manual annotation. The system employs principal component analysis for dimensionality reduction and trains a convolutional neural network to recognize temporal patterns that precede bed exits. Our test results demonstrate that the system can predict bed-exit events up to 30 s in advance with ±1 s accuracy. This supervised learning framework enables continuous adaptation of the model to individual patient behaviors and changing environmental conditions, addressing key limitations of existing healthcare monitoring technologies. The demonstrated ability to detect subtle pre-exit patterns imperceptible to conventional sensing approaches represents a significant advancement toward intelligent patient monitoring systems that enhance safety through predictive rather than reactive intervention strategies.

  • Highly Sensitive Fiber Optic Sensor for Simultaneous Refractive Index and Temperature Measurement Using Suspended Core Fiber

    by Xindi Zhang, Xue Zhou, Yanan Zhang, Linh Viet Nguyen, Yong Zhao, Stephen C. Warren-Smith, Xuegang Li

    A novel fiber optic sensor has been developed using suspended core fiber (SCF) to simultaneously measure the refractive index (RI) and temperature of liquids. The innovative design comprises an SCF segment spliced between two tapered single-mode fibers (SMFs). The SCF allows the transmission of multiple modes, thus enabling multimode interference. Importantly, the three internal holes of the SCF function as microfluidic channels, providing direct access to the evanescent field of the micrometer-scaled core. This direct interaction significantly enhances the sensor’s sensitivity by intensifying the light-sample interaction. Each pair of interfering optical modes exhibits distinct sensitivity to both temperature and RI. By performing Fourier analysis, the interference spectrum for each mode pair can be extracted. High sensitivity is achieved, with the values of 1560 and 1217 nm/RIU for RI within the range 1.3309–1.3350 and −0.25 nm/°C and −0.31 nm/°C for temperatures ranging from 20 °C to 40 °C. The resolutions of RI and temperature were $1.3 \times 10^{-5}$ RIU and 0.06 °C, respectively. The transfer matrix method effectively eliminates temperature interference during RI measurement, ensuring reliable and accurate RI readings. The sensor is shown to have a detection limit as low as $6.1 \times 10^{-5}$ RIU and 0.3 °C. Combining its desirable characteristics of good stability, a simple structure, and high sensitivity, this novel sensor holds significant promise for diverse applications in environmental monitoring, medical testing, and biological sensing.


  • Multimode Optical Fiber Specklegram Pressure Sensor Using Deep Learning

    by Mohammad Istiaque Reja, Darcy L. Smith, Linh Viet Nguyen, Heike Ebendorff-Heidepriem, Stephen C. Warren-Smith

    Optical fiber pressure sensing is of significant interest for industrial process monitoring and acoustic sensing. However, the direct detection of pressure changes along an optical fiber with minimal crosstalk is a significant challenge due to the low stress-optic coefficient of glass and interferences from temperature, bending, and strain. Here, we demonstrate that deep learning combined with microstructured optical fiber specklegram sensing is an effective approach to overcoming environmental crosstalk for the challenging application of pressure sensing. Specklegrams created from multimode interference are inherently sensitive to both the measurand of interest and other environmental perturbations. By employing a deep neural network, namely a multilayer perceptron, we show that the environmental crosstalk of the specklegram-based pressure sensor can be mitigated. Furthermore, we demonstrate the practical implementation of the machine learning-based pressure sensor where we need to continuously update the model. We show that the network can learn and reject environmental disturbances and predict pressure values correctly through continuous training updates. This technique approaches the instrument error of our calibration pressure gauge, with an error below 3 kPa over a range of 1 MPa.


  • Dynamic Multimode Fiber Specklegram Sensor Smart Bed Enabled by Deep Learning

    by Mohammad Nazmul Islam Sarkar, Linh Viet Nguyen, Adam D. Kilpatrick, David G. Lancaster, Stephen C. Warren-Smith

    Fiber specklegram sensors eliminate the need for complex optical interrogators by using a camera to capture images or videos of the speckle pattern at the end facet of a multimode optical fiber. A fiber specklegram sensor is highly sensitive to movement anywhere along the length of the fiber, yielding complex information on external perturbations. The ability of the fiber specklegram sensor to be laid over a large surface area and respond to movement at any location can be useful in many real life sensing problems. Until now, only static speckle images have been used to evaluate such perturbations. However, there are applications where intrinsically dynamic measurands are desired, requiring different approaches to the analysis. In this work, we utilized deep learning techniques to analyze dynamic speckle videos for applications in dynamic biomechanical sensing, which we demonstrated for respiration rate monitoring as a proof-of-concept. This application demands both wide area sensing, that is, coverage of a mattress, together with dynamic information. We achieve this by recording videos of speckle from a single multimode fiber that covers a mattress in an S-configuration, and train convolutional neural networks directly on the video data. We show that the fiber specklegram sensor combined with our deep learning model can accurately classify the respiration rate. This approach has wide reaching potential for other biomechanical healthcare applications, such as pressure sore prevention and continuous monitoring to reduce the risk of falls.


  • Ultrasensitive Label-Free Biosensor for Triglyceride Detection Based on Exposed-Core Optical Fiber

    by Xindi Zhang, Xue Zhou, Yanan Zhang, Yong Zhao, Linh Viet Nguyen, Stephen C. Warren-Smith, Xuegang Li

    Accurate detection of triglycerides (TGs) is important for the prevention and monitoring of dyslipidemia and for understanding the mechanisms of metabolic diseases. In this article, an ultrasensitive label-free sensor for measuring TGs based on an exposed-core optical fiber is presented. The sensor head was formed by splicing a single-mode optical fiber, a multimode optical fiber, and an exposed-core fiber in a Mach–Zehnder interferometer configuration. The Mach–Zehnder interference (MZI) occurs between the exposed core of the fiber, which is only micrometer in size, and the external environment. This allows the light path to pass directly through the liquid sample, resulting in an ultrahigh refractive index sensitivity of 13300 nm/RIU in the refractive index range of 1.331–1.332. In addition, lipase is immobilized on the optical fiber sensor to measure the concentration of TGs by detecting the change in the refractive index of the sample solution caused by the hydrolysis of TGs by lipase. The results showed that this sensor can specifically detect the concentration of TGs with a sensitivity of 1.72 nm/nM and a detection limit of 35 pM. It has the potential to revolutionize the diagnosis and monitoring of TGs and thus impact the prevention and treatment of dyslipidemia and other metabolic diseases.


  • Label Free hCG Concentration Biosensor Based on Suspension Core Fiber Microfluidic Technology

    by Xuegang Li, Xindi Zhang, Xue Zhou, Yong Zhao, Linh Viet Nguyen, Yanan Zhang, Stephen C. Warren-Smith

    In this paper, a microfluidic sensor based on suspended core fiber (SCF) for detecting the concentration of human chorionic gonadotropin (hCG) has been presented and experimentally demonstrated. The sensor is made by splicing SCF between two sections of drawn-tapered single-mode fiber (SMF). The SCF is a multimode fiber that supports multi-mode optical transmission and generates mode interference in the fiber core. The air holes in the SCF can also be used as microcirculation channels for the sensor, enhancing the interaction between the detection sample and the light field and improving the refractive index (RI) sensitivity. Due to the closed microchannels, the sensor has good anti-interference and stability, can effectively prevent biological pollution. The sensitivity of RI is 1848 nm/RIU in the RI range of 1.3335-1.3419. The sensor can also detect local RI changes on the fiber surface due to biomolecule binding. The hCG antigen can specifically bind to the hCG-β antibody. The hCG-β antibody is immobilized in the air holes of the SCF to specifically detect the concentration of hCG. Experimental results showed that the sensor can specifically detect hCG concentration with a sensitivity of 1.888nm/(mIU/ml) and a detection limit of 0.049 mIU/ml at a temperature of 25°C. This sensor has good specificity and potential applications in medical diagnostics, drug testing, and tumor screening.


  • Open Access

    Mitigating stimulated Brillouin scattering in multimode fibers with focused output via wavefront shaping

    by Chun-Wei Chen, Linh V. Nguyen, Kabish Wisal, Shuen Wei, Stephen C. Warren-Smith, Ori Henderson-Sapir, Erik P. Schartner, Peyman Ahmadi, Heike Ebendorff-Heidepriem, A. Douglas Stone, et al.

    The key challenge for high-power delivery through optical fibers is overcoming nonlinear optical effects. To keep a smooth output beam, most techniques for mitigating optical nonlinearities are restricted to single-mode fibers. Moving out of the single-mode paradigm, we show experimentally that wavefront-shaping of coherent input light to a highly multimode fiber can increase the power threshold for stimulated Brillouin scattering (SBS) by an order of magnitude, whilst simultaneously controlling the output beam profile. The SBS suppression results from an effective broadening of the Brillouin spectrum under multimode excitation, without broadening of transmitted light. Strongest suppression is achieved with selective mode excitation that gives the broadest Brillouin spectrum. Our method is efficient, robust, and applicable to continuous waves and pulses. This work points toward a promising route for mitigating detrimental nonlinear effects in optical fibers, enabling further power scaling of high-power fiber systems for applications to directed energy, remote sensing, and gravitational-wave detection.


  • Whispering Gallery Mode Microresonator Sensor Integrated in Exposed Core Fiber for Label-Free DNA Hybridization Detection

    by Xue Zhou, Shankun Wang, Xuegang Li, Yong Zhao, Yanan Zhang, Linh Viet Nguyen, Stephen C. Warren-Smith

    A novel optical fiber sensor using exposed-core fiber (ECF) to excite whispering gallery modes (WGMs) within a high refractive index barium titanate glass microsphere is proposed for achieving label-free real-time specific DNA detection. The microsphere is encapsulated into the exposed channel of the ECF allowing for physical stability while excited WGMs via the evanescent field. The structure enables the sensing area to be exposed to a large amount of aqueous solution and better contact with the sample to be analyzed. Using a transmission measurement, a high Q-factor in the order of 10 4 is obtained in an aqueous environment. To the best of our knowledge, this is the best Q-factor level obtained by the in fiber WGM sensor in an aqueous environment. Specific sequences of probe DNA are then bound to the surface of the microsphere so that specific detection of complementary DNA can be realized by tracking the wavelength shift the WGM resonance. Experimental results show a red shift of 5.6 pm for complementary DNA hybridization detection and less than 1 pm fluctuation for non-complementary DNA detection. The portable integrated sensor with miniature size has great potential for aqueous environmental sensing applications in the fields of diseases diagnostics, chemical analysis, and environmental protection.


  • Optical Fiber DNA Biosensor With Temperature Monitoring Based on Double Microcavities Fabry–Perot Interference and Vernier Combined Effect

    by Xuegang Li, Fei Li, Xue Zhou, Yanan Zhang, Linh Viet Nguyen, Stephen C. Warren-Smith, Yong Zhao

    This paper introduces a label-free DNA sensor based on the based on double microcavities Fabry-Perot interference and Vernier effect. The sensor can simultaneously monitor temperature to avoid interference with the process of measuring DNA. The biosensor is composed of two open microcavities made of C-type optical fiber. One of the microcavities will is functionalized by the probe DNA (pDNA) to hybridize with complementary DNA (cDNA). And the other microcavity is fille with PDMS to realize temperature sensitivity. At the same time, the two cavities will form a Vernier effect, which is sensitive to both temperature and DNA. It is proved by experiments that the temperature sensitivity and refractive index (RI) sensitivity of the sensor are -2.79 nm/°C and -7122.63 nm/RIU, respectively. The proposed sensor has good specificity. cDNA sequence can bind well to given targets, but hardly bind to non-complementary DNA (non-cDNA) sequences. Moreover, the sensor offers some other has the benefits of high sensitivity, dual-parameter detection, real-time response, and simple fabrication. This is of great significance to solve the problem of temperature sensitivity of biosensors.